• 제목/요약/키워드: X-ray Imaging

검색결과 1,056건 처리시간 0.037초

Mercuric iodide 기반의 디지털 X-선 검출기의 특성 연구 (Characterization studies of digital x-ray detector based on mercuric iodide)

  • 조성호;박지군;최장용;석대우;차병열;남상회;이범종
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 추계학술대회 논문집 Vol.16
    • /
    • pp.392-395
    • /
    • 2003
  • For the purpose of digital x-ray imaging, many materials such as $PbI_2$, $HgI_2$, TlBr, CdTe and CdZnTe have been under development for servaral years as direct converter layer. $Hgl_2$ film detector have recently been shown as one of the most promising semiconductor materials to be used as direct converters in x-ray digital radiography. This paper, the $HgI_2$ films are deposited on conductive-coated glass by screen printing, in which $HgI_2$ powder is embedded in a binder and solvent, and the slurry is used to coat the conductive-coated glass. We investigated electrical characteristic of the fabricated $HgI_2$ films. The x-ray response to radiological x-ray generator of 70Kvp using the current integration mode will be reported for screen printing films. These results indicate that $HgI_2$ detectors have high potential as new digital x-ray imaging devices for radiography.

  • PDF

Imaging Technologies for Nondestructive Measurement of Internal Properties of Agricultural Products: A Review

  • Ahmed, Mohammed Raju;Yasmin, Jannat;Lee, Wang-Hee;Mo, Changyeun;Cho, Byoung-Kwan
    • Journal of Biosystems Engineering
    • /
    • 제42권3호
    • /
    • pp.199-216
    • /
    • 2017
  • Purpose: This study reviewed the major nondestructive measurement techniques used to assess internal properties of agricultural materials that significantly influence the quality, safety, and value of the products in markets. Methods: Imaging technologies are powerful nondestructive analytical tools that possess specific advantages in revealing the internal properties of products. Results: This review was exploring the application of various imaging techniques, specifically, hyperspectral imaging (HSI), magnetic resonance imaging (MRI), soft X-ray, X-ray computed tomography (XRI-CT), thermal imaging (TI), and ultrasound imaging (UI), to investigate the internal properties of agricultural commodities. Conclusions: The basic instruments used in these techniques are discussed in the initial part of the review. In the context of an investigation of the internal properties of agricultural products, including crops, fruits, vegetables, poultry, meat, fish, and seeds, various extant studies are examined to understand the potential of these imaging technologies. Future trends for these imaging techniques are also presented.

생물의료용 연 X-선 현미경 시스템 개발 (Development of a soft X-ray microscopy system for Biological Application)

  • 김경우;권영만;김규겸;민종환;박정권;임종혁;남기용;윤권하;민진영
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2005년도 제16회 정기총회 및 동계학술발표회
    • /
    • pp.264-265
    • /
    • 2005
  • In this paper the conceptual design and development of a compact vertical type soft x-ray microscope is described. This x-ray microscope operates in the water window wavelength region(2.3 ${\sim}$ 4.4nm), where natural contrast between carbon(protein) and oxygen(water) allows imaging of unstained biological material their natural, hydrated environment. Until now, operational x-ray microscopes are based on synchrotron radiation sources, which limit their accessibility. Many biologists would benefit from having the x-ray microscope as a tool among other tools in their own laboratory, For this purpose we introduced the compact vertical type soft X-ray microscope with 50 nm resolution for biomedical application. The compact vertical type soft x-ray microscope is based on a laser plasma x-ray source, doubled ellipsoidal condenser reflective optics, diffractive zone plate optics and MCP coupled with CCD to record an x-ray image.

  • PDF

3D Inspection by Registration of CT and Dual X-ray Images

  • Kim, Youngjun;Kim, Wontae;Lee, Deukhee
    • Journal of International Society for Simulation Surgery
    • /
    • 제3권1호
    • /
    • pp.16-21
    • /
    • 2016
  • Computed tomography (CT) can completely digitize the interior and the exterior of nearly any object without any destruction. Generally, the resolution for industrial CT is below a few microns. The industrial CT scanning, however, has a limitation because it requires long measuring and processing time. Whereas, 2D X-ray imaging is fast. In this paper, we propose a novel concept of 3D non-destructive inspection technique using the advantages of both micro-CT and dual X-ray images. After registering the master object’s CT data and the sample objects’ dual X-ray images, 3D non-destructive inspection is possible by analyzing the matching results. Calculation for the registration is accelerated by parallel computing using graphics processing unit (GPU).

고효율 X선 검출기 적용을 위한 PbO 필름 제작 및 특성 연구 (Fabrication and Characterization of Lead Oxide (PbO) Film for High Efficiency X-ray Detector)

  • 조성호;강상식;최치원;권철;남상희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 하계학술대회 논문집 Vol.8
    • /
    • pp.329-329
    • /
    • 2007
  • Photoconductive poly crystalline lead oxide coated on amorphous thin film transistor (TFT) arrays is the best candidate for direct digital x-ray detector for medical imaging. Thicker films with lessening density often show lower x-ray induced charge generation and collection becomes less efficient. In this work, we present a new methodology used for the high density deposition of PbO. We investigate the structural properties of the films using X-ray diffraction and electron microscopy experiments. The film coatings of approximately $200\;{\mu}m$ thickness were deposited on $2"{\times}2"$ conductive-coated glass substrates for measurements of dark current and x-ray sensitivity. The lead oxide (PbO) films of $200\;{\mu}m$ thickness were deposited on glass substrates using a wet coating process in room temperature. The influence of post-deposition annealing on the characteristics of the lead oxide films was investigated in detail. X-ray diffraction and scanning electron microscopy, and atomic force microscopy have been employed to obtain information on the morphology and crystallization of the films. Also we measured dark current, x-ray sensitivity and linearity for investigation of the electrical characteristics of films. It was found that the annealing conditions strongly affect the electrical properties of the films. The x-ray induced output charges of films annealed in oxygen gas increases dramatically with increasing annealing temperatures up to $500^{\circ}C$ but then drops for higher temperature anneals. Consequently, the more we increase the annealing temperatures, the better density and film quality of the lead oxide. Analysis of this data suggests that incorporation and decomposition reactions of oxygen can be controlled to change the detection properties of the lead oxide film significantly. Post-deposition thermal annealing is also used for densely film. The PbO films that are grown by new methodology exhibit good morphology of high density structure and provide less than $10\;pA/mm^2$ dark currents as they show saturation in gain (at approximate fields of $4\;V/{\mu}m$). The ability to operate at low voltage gives adequate dark currents for most applications and allows voltage electronics designs.

  • PDF

초음파 영상진단장치 (A Diagnostic Ultrasound Imaging System)

  • 이승우
    • 비파괴검사학회지
    • /
    • 제19권3호
    • /
    • pp.217-232
    • /
    • 1999
  • The ability to see the internal organs of the human body in a noninvasive way is a powerful diagnostic tool of modern medicine. Among these imaging modalities such as X-ray, MRI, and ultrasound. MRI and ultrasound are presenting much less risk of undesirable damage of both patient and examiner. In fact, no deleterious effects have been reported as a result of clinical examination by using MRI and ultrasound diagnostic equipment. As a result. their market volume has been rapidly increased. MRI has a good resolution. but there are a few disadvantages such as high price. non-real-time imaging capability. and expensive diagnostic cost. On the other hand, the ultrasound imaging system has inherently poor resolution as compared with X-ray and MRI. In spite of its poor resolution, the ultrasound diagnostic equipment is lower in price and has an ability of real-time imaging as compared with the others. As a result. the ultrasound imaging system has become general and essential modality for imaging the internal organs of human body. In this review various researches and developments to enhance the resolution of the ultrasound images are explained and future trends of the ultrasound imaging technology are described.

  • PDF

레이저 플라즈마 기반의 생물의료용 연 X-선 현미경 설계 (Conceptual Design of Laser Plasma-based Soft X-ray Microscope system for Biomedical Application)

  • 김경우;윤권하
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.690-693
    • /
    • 2003
  • Soft x-ray microscopy provides a unique set of capabilities in-between those of visible light and electron microscopy. It has long been recognized that nature provides a 'water window' spectral region between the K shell x-ray absorption edges of carbon (~290eV) and oxygen (~540eV), where organic materials show strong absorption and phase contrast, while water is relatively non-absorbing. This enables imaging of hydrated biological specimens that are several microns thick with high intrinsic contrast using x-rays with a wavelength of 2.3~4.4nm. Soft X-ray microscopy is therefore well suited to the study of specimens like single biological cells. The most direct advantage of X-ray microscope is their high spatial resolution when compared with visible light microscopes, combined with an ability to image hydrated specimens that are several microns with a minimum of preparation. Our study describes the conceptual design of soft x-ray microscope system based on a laser-based source for biomedical application with high resolution ($\leq$50nm) and short exposure time ($\leq$30sec).

  • PDF

어린이 성장판 영상화를 위한 초음파와 X-선 방식의 비교 평가 (Comparison Between Ultrasonic and X-ray Methods for Imaging the Children′s Growth Plate)

  • 김상후;김형준;한은옥;한승무
    • 대한의용생체공학회:의공학회지
    • /
    • 제25권6호
    • /
    • pp.551-556
    • /
    • 2004
  • 본 연구에서는 진단 방법의 정확성이 아직까지 구체적으로 규명되지 않고 있는 어린이의 성장 발육을 체계적이고 과학적으로 측정할 수 있는 방법을 제시하고자 시도하였다. 현재 많이 이용되고 있는 성장 진단 방법은 X-ray 영상을 이용한 각 관절 부위의 성장판의 개폐 분석이다. 그러나 X-ray 방식은 성장 진단에서 요구되는 주기적이고 반복적인 측정을 하지 못함과 동시에 방사선 노출이라는 단점을 가지고 있다. 따라서 인체에 무해한 초음파 영상을 이용한 성장판 개폐 분석 대체 가능성을 평가하기 위해 종골의 초음파 광역 감쇄 영상을 이용한 프로파일 분석 및 성장판 영상 분석 알고리즘을 제시하였다. 본 연구에서는 7세~16세의 어린이 269명에 대해서 X-ray를 이용하여 무릎, 손가락, 종골에서의 성장판 영상을 얻었다. 또한 초음파 방식을 이용하여 종골의 성장판 영상을 얻었다. 각 관절에서의 성장판 개폐 유무 시기는 각 개인별로 측정 방법에 따라 조금의 차이는 있으나 전반적으로 일치하였다. 또한. X-ray방식과 초음파 방식에 의한 성장판 영상을 비교한 결과 상호 높은 연관성을 나타내었다. 이와 같이 성장판을 정확하게 측정하기 위해 도입된 초음파 프로파일 분석 알고리즘은 기존의 X-ray 영상 방식에 의한 성장판의 측정을 대체할 수 있을 것으로 사료된다.

X-ray 영상을 이용한 척추측만증 영상처리 알고리즘 개발 (Algorithm Development of Scoliosis Image Processing using X-ray Imaging)

  • 박은정;정주영;배철수;이상식
    • 한국정보전자통신기술학회논문지
    • /
    • 제4권2호
    • /
    • pp.88-95
    • /
    • 2011
  • 본 연구에서는 코브 각도 측정법을 이용하여 척추 X-ray 영상을 측정할 때에 적용이 용이하도록 추간원판을 뚜렷하게 만드는 영상처리 알고리즘과 코브 각도 측정법을 일일이 적용하지 않고도 척추 전장을 포함하는 X-ray 필름의 기립 후전방 척추 영상을 하나의 척추선 함수 그래프로 변환하여 척추측만 정도 측정에 적용 또는 응용이 용이하게 하는 영상처리 알고리즘을 제시하였다. 척추 X-ray영상의 코브 각도 $1^{\circ}$당 L값의 평균을 산출한 결과는 0.568로 나타났고, 이를 기준으로 척추측만 정도 검출이 가능하였다.