• Title/Summary/Keyword: X-ray Examination

Search Result 653, Processing Time 0.03 seconds

Feasibility study of insertable miniature x-ray source for dental imaging (치과 영상용 삽입형 초소형 X선 튜브의 가능성 연구)

  • Cho, Sung-Ho;Kim, So-Yeong;An, So-Hyun;Lim, Soo-Mee;Lee, Re-Na
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.1
    • /
    • pp.39-45
    • /
    • 2012
  • Conventional periphery radiography system has a various problem such as patient dose and the pain of X-ray examination. In this paper, to solve these problems, we suggested insertional miniature x-ray system and we verified the feasibility of this system. First, we performed the Geant4 x-ray simulation to design x-ray collimator and filter to use miniature x-ray tube and we decided optimized thickness of filter and collimator. Also, we measured x-ray spectrum using CdTe detector and PX4 module to verify simulation results. Also, we acquired teeth image of fabricated phantom using conventional dental x-ray and prosed miniature x-ray system. As a results, our system has good image quality as compared to those of conventional systems. Our evaluation of the proposed system indicates that it can be potentially very useful for dental imaging.

Diagnostic X-ray Spectra Detection by Monte Carlo Simulation (진단용 X-선 스펙트럼의 몬테칼로 전산모사 측정)

  • Baek, Cheol-Ha;Lee, Seung-Jae;Kim, Daehong
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.3
    • /
    • pp.289-295
    • /
    • 2018
  • Most diagnostic devices in the medical field use X-ray sources, which emit energy spectra. In radiological diagnosis, the quantitative and qualitative analyses of X-rays are essential for maintaining the image quality and minimizing the radiation dose to patients. This work aims to obtain the X-ray energy spectra used in diagnostic imaging by Monte Carlo simulation. Various X-ray spectra are simulated using a Monte Carlo simulation tool. These spectra are then compared to the reference data obtained with a tungsten anode spectral model using the interpolating polynomial (TASMIP) code. The X-ray tube voltages used are 50, 60, 80, 100, and 110 kV, respectively. CdTe and a-Se detector are used as the detectors for obtaining the X-ray spectra. Simulation results demonstrate that the various X-ray spectra are well matched with the reference data. Based on the simulation results, an appropriate X-ray spectrum, in accordance with the tube voltage, can be selected when generating an image for diagnostic imaging. The dose to be delivered to the patient can be predicted prior to examination in the diagnostic field.

Development of X-Ray Array Detector Signal Processing System (X-Ray 어레이 검출 모듈 신호처리 시스템 개발)

  • Lim, Ik-Chan;Park, Jong-Won;Kim, Young-Kil;Sung, So-Young
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.10
    • /
    • pp.1298-1304
    • /
    • 2019
  • Since the 9·11 terror attack in 2001, the Maritime Logistics Security System has been strengthened and required X-ray image for every imported cargos from manufacturing countries to United States. For scanning cargos, the container inspection systems use high energy X-rays for examination of contents of a container to check the nuclear, explosive, dangerous and illegal materials. Nowadays, the X-ray cargo scanners are established and used by global technologies for inspection of suspected cargos in the customs agency but these technologies have not been localized and developed sufficiently. In this paper, we propose the X-ray array detector system which is a core component of the container scanning system. For implementation of X-ray array detector, the analog and digital signal processing units are fabricated with integrated hardware, FPGA logics and GUI software for real-time X-ray images. The implemented system is superior in terms of resolution and power consumption compared to the existing products currently used in ports.

The analytical application for cement using X-Ray diffraction and X-Ray fluorescence spectrometer (X-Ray Diffraction과 X-Ray Fluorescence를 이용한 시멘트 비교 분석)

  • Jung, Ji Eun;Jang, Yu Rim;Kim, Ki-Wook;Heo, Sangcheol;Min, Ji-Sook
    • Analytical Science and Technology
    • /
    • v.26 no.5
    • /
    • pp.340-351
    • /
    • 2013
  • The chemical element and structural characterization of different types of cements and its brick stones are been investigated under forensic aspects using X-ray florescence (XRF) and X-ray diffraction (XRD) spectrometer. The XRF provides rapid compositional data for controlling almost all stages of raw materials, clinker and cement. The decisive advantage of XRD methods is based on the unique character of the diffraction patterns of crystalline substances, the ability to distinguish between elements and their oxides, and the possibility to identify chemical compounds, polymeric forms, and mixed crystals by non-destructive examination. Therefore, combination of these examinations is useful and able to apply for the forensic analysis in comparison of cements and brick stones. There are more study remained to determine the viability of method for forensic analysis of brick stones and the limits of the discrimination that can be achieved.

Quality Control of Diagnostic X-ray Equipment in Medical Field (의료분야 진단용방사선발생장치의 품질관리)

  • Cho, Pyong-Kon
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.2
    • /
    • pp.159-164
    • /
    • 2021
  • The examination using diagnostic x-ray equipment is one of the most useful diagnostic equipment for identifying information in the human body in diagnostic radiology. For this reason, the number of examinations has recently increased a lot. Increasing the number of examinations will accelerate the aging of the device. In addition, this makes them aware of the importance of quality control for the diagnostic x-ray device. Particularly, in a diagnostic x-ray device, quality control refers to an act of always maintaining a certain level of image quality by identifying and correcting all problems that may lead to reduction of the diagnosis area in advance. Therefore, this study summarizes and reports general information about quality control in examinations using diagnostic x-ray equipment.

Management Methods of Bone Mineral Density Examination Using Dual Energy X-ray Absorptiometry (이중에너지 엑스선 흡광분석법을 이용한 골밀도검사의 관리법)

  • Kim, Ho-Sung;Kim, Tae-Hyung;Kim, Sang-Hyun
    • Journal of radiological science and technology
    • /
    • v.41 no.4
    • /
    • pp.351-360
    • /
    • 2018
  • In recent years, demand for examination of bone mineral density (BMD) is increasing in Korea according aging society. Therefore, it is required to develop an efficient management program that can increase the safety and reliability of Dual Energy X-ray Absorptiometry (DXA) that can be applied to the criteria of the World Health Organization. It is necessary to develop a management program that can design a program to improve the accuracy and precision of the results of the analysis and to improve the accuracy of diagnosis of osteoporosis by development a high quality DXA report. It is recommended to prepare the examination manuals and to establish procedures of standard operating including the program to prevent the pitfalls during the examination, the compatibility evaluation of the examination data, and the contents of the radiation safety. In addition, relevant regulations on the production of high-quality DXA reports are required and government and related agencies should introduce individual and facility recognition programs through DXA measurement and education programs and training. It is considered that efforts should be made to prepare high quality DXA report by guidelines on all aspects of BMD for preparation about aging society.

Clinical and Roentgen Pelvimetry;A Correlation and Efficacy (X선골반계측;임상적 가치와 유효성여부에 관하여)

  • Lee, S.H.;Park, T.K.;Kwak, H.M.
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.8 no.2
    • /
    • pp.35-43
    • /
    • 1981
  • In order to evaluate the clinical utilization and efficacy of X-ray pelvimeter, a study of selective information from 292 cases, who had clinical and X-ray pelvimetry, among 7346 single term deliveries in the years 1975 and 1978 was undertaken in Yonsei University Medical Center. The results revealed that there were no significant statistical difference between X-ray and clinical pelvimetry groups in terms of the outcome of labor and in regard to determining the pelvic size (p > 0.05). Most X-ray examination which caused significant fetal exposure were pelvimetries.

  • PDF

Improvement Way for Mobile X-ray Examinations by Rule Revision about Safety Management of Diagnosis Radiation Occurrence System (진단용방사선발생장치의 안전관리에 관한 규칙 개정에 따른 이동형 방사선검사의 개선방안)

  • Choi, Jun-Gu;Kim, Gyeong-Su;Kim, Byeong-Gi;Ahn, Nam-Jun;Kim, Hyeong-Sun;Kim, Sang-Geon;Lim, Si-Eun
    • Journal of radiological science and technology
    • /
    • v.30 no.1
    • /
    • pp.53-59
    • /
    • 2007
  • A safety management rule of the diagnosis radiation system which opened a court 2006 February 10th was promulgated for safety of the radiation worker, patients and patients' family members. The purpose of this study is to minimize injury by radiation that can happen to patients and people around a sick ward when managing mobile X-ray system. This study analyzed sickroom environment of mobile X-ray examination and the statistical data of the Konkuk medical Information System(KIS) and the Picture Archiving Communication System(PACS). This study also investigated patient conditions, infection, relation information and related data, when the sickroom mobile X-ray examination is used. Through data analysis, many problems were expected such as restriction of space side, manpower and expense of business side, satisfaction degree decline of patient and protector of operation side. Therefore, we tried to restrict examination of multi bed sickroom, and to use treatment room in each ward to solve problem mentioned. As a result, the whole sickroom mobile X-ray examination rate decreased to near 50%, and mobile X-ray examination rate for inpatients decreased to more than 85%. This study shows that several attempts we did should be helpful for manpower, patients satisfaction and expenses. Also, they should protect patients in sickroom from unnecessary radiation exposure and could minimize inconvenience of patients and their family members from x-ray examination.

  • PDF

The Utility of Routine Chest X-Ray on Korean Medicine Hospital Admission (한방병원 입원 시 관례적 흉부 X선 검사의 유용성)

  • Choi, In-woo;Yoo, Ho-ryong
    • The Journal of Internal Korean Medicine
    • /
    • v.42 no.4
    • /
    • pp.622-627
    • /
    • 2021
  • Objective: This study was designed to analyze the utility of routine chest X-ray on Korean medicine hospital admission. Methods: The chest X-ray reports and medical records of 618 patients who were admitted to Daejeon Korean Medicine Hospital from May 1, 2021 to June 30, 2021 were retrospectively reviewed. Results: Of the 618 patients newly hospitalized from May 1, 2021 to June 30, 2021, 560 patients (excluding readmission) were analyzed. The mean age of 560 patients was 53.26±17.20 years. There were 52 patients with abnormal findings, and their mean age was 69.62±15.59 years. Many of these patients had chest symptoms and a history of chest disease. There was no case that showed a significant diagnostic result by chest X-ray examination. Conclusion: The diagnostic usefulness of routine chest X-rays in Korean medicine hospital admission is low. But this does not mean that there is no need to perform routine chest X-rays upon admission.

Correlation Analysis Between Narrowing Disc Space of Lumbar X-ray and HIVD of L-spine CT in Lumbosacral Strain Patients (좌섬요통환자에서 X-ray상 narrowing과 CT상 HIVD와의 연관성 분석)

  • Kim, Eun-young;Kim, Young-wook;Lee, Kyung-min;Kim, Ju-youn;Kim, Hyo-eun;Kang, Young-hwa;Seo, Jung-chul;Lim, Sung-chul;Han, Sang-won
    • Journal of Acupuncture Research
    • /
    • v.19 no.6
    • /
    • pp.125-133
    • /
    • 2002
  • Objective : This study was designed to analyze the of correlation between narrowing disc space of lumbar X-ray and HIVD of L-spine CT in lumbosacral strain patients. Methods : 63 cases of lumbosacral strain patients who visited Bul-kyooh Oriental Hospital from June 13, 2000 to August 9, 2001 were selected. We performed the radiography by lumbar X-ray and L-spine CT for all cases. Results : 28 of 63 cases revealed narrowing disc space in Lumbar X-ray and these 28 cases were diagnosed as HIVD in L-spine CT at all. 35 of 63 cases revealed normal in Lumbar X-ray and 13 of these 35 cases were diagnosed as HIVD in L-spine CT. Conclusions : We found that narrowing disc space in lumbar X-ray has significant relevance to HIVD in L-spine CT(P-value = 0.001). For accurate diagnosis and treatment of lumbosacral strain patients. combination of clinical symptoms, physical examination and radiography of X-ray and HIVD is needed.

  • PDF