• Title/Summary/Keyword: X-ray 시스템

Search Result 500, Processing Time 0.028 seconds

Design of Head Blood Pressure(HBP) Measurement System and Correlativity Extraction of Blood Pressure(BP) and HBP (두부혈압 측정 시스템의 설계 및 두부혈압과 상완혈압과의 상관성 추출)

  • 이용흠;정석준;장근중;정동영
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.5
    • /
    • pp.381-389
    • /
    • 2003
  • Various adult diseases (cerebral apoplexy, athymiait, etc.) result from hypertension, blood circulation disturbance and increment of HBP. In early diagnosis of these diseases, MRI, X-ray and PET have been used rather aim for treatment than for a prevention of disease. Since. cerebral apoplexy and athymiait could appear to the regular/irregular persons, it is very important to measure HBP which has connection with cerebral blood flow state. HBP has more diagnosis elements than that of BP. So, we can diagnose accurate hypertension by measuring of HBP. But, existing sphygmomanometers and automatic BP monitors can not measure HBP, and can not execute complex function(measuring of BP/HBP, blood flow improvement). Purpose of this paper is to develop a system and algorithm which can measure BP/HBP for accurate diagnosis. Also, we extracted diagnosis factors by correlativity analysis of BP/HBP. Maximum pressure of HBP corresponds to 62% that of BP, Minimum pressure of HBP corresponds to 46% that of BP. Therefore, we developed the multi-function automatic blood pressure monitor which can measure BP/HBP and improve cerebral blood flow state.

Simulation of Energy Resolution of Time of Flight System for Measuring Positron-annihilation induced Auger Electrons (양전자 소멸 Auger 전자 에너지 측정을 위한 Time of Flight의 분해도 향상에 관한 이론적 연구)

  • Kim, J.H.;Yang, T.K.;Lee, C.Y.;Lee, B.C.
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.4
    • /
    • pp.311-316
    • /
    • 2008
  • Since the presence of the chemical impurities and defect at surfaces and interfaces greatly influence the properties of various semiconductor devices, an unambiguous chemical characterization of the metal and semiconductor surfaces become more important in the view of the miniaturization of the devices toward nano scale. Among the various conventional surface characterization tools, Electron-induced Auger Electron Spectroscopy (EAES), X-ray Photoelectron Spectroscopy (XPS) and Secondary Electron Ion Mass Spectroscopy (SIMS) are being used for the identification of the surface chemical impurities. Recently, a novel surface characterizaion technique, Positron-annihilation induced Auger Electron Spectroscopy (PAES) is introduced to provide a unique method for the analysis of the elemental composition of the top-most atomic layer. In PAES, monoenergetic positron of a few eV are implanted to the surface under study and these positrons become thermalized near the surface. A fraction of the thermalized positron trapped at the surface state annihilate with the neighboring core-level electrons, creating core-hole excitations, which initiate the Auger process with the emission of Auger electrons almost simultaneously with the emission of annihilating gamma-rays. The energy of electrons is generally determined by employing ExB energy selector, which shows a poor resolution of $6{\sim}10eV$. In this paper, time-of-flight system is employed to measure the electrons energy with an enhanced energy resolution. The experimental result is compared with simulation results in the case of both linear (with retarding tube) and reflected TOF systems.

A Distributed Intelligent System for Multidisciplinary Design Optimization (다분야통합최적설계를 위한 지능형 분산 시스템)

  • 이재호;홍은지
    • Proceedings of the Korea Inteligent Information System Society Conference
    • /
    • 2000.11a
    • /
    • pp.257-266
    • /
    • 2000
  • 산업 및 가정용 기기들이 점차 복잡해짐에 따라 다양한 공학 분야의 해석 기술을 동시에 고려하면서 이들 원리를 적용한 최적의 설계를 결정하는 방법론의 필요성이 대두되고 있다. 다분야통합최적설계 또는 MDO(Multidisciplinary Design Optimization)라 일컫는 새로운 기술은 이러한 필요에 대응하는 기술로서 국내외적으로 활발한 연구가 진행되고 있다. 이러한 MDO 기술을 구현하는 소프트웨어와 하드웨어 복합 체계를 MDO 프레임웍(framework)이라 한다. 일반적으로 프레임웍이란 실제 응용프로그램의 용도에 맞는 주문제작(customization)이 가능한 일종의 전단계 프로그램이라 할 수 있다 MDO 프레임웍은 설계 및 해석 도구들간의 인터페이스를 제공하고, 이들 도구들이 사용하는 설계 데이터를 효율적으로 공유할 수 있도록 지원하여, 설계 작업을 정의, 실행, 관리하는 역할을 한다. 이러한 MDO 프레임웍은 설계 작업을 통합적으로 관리하고 자동화하여 설계 도구간의 데이터 전달과 변환에 소묘되는 설계자의 부담을 경감시키며 다분야 전문가가 참여하는 공통 작업 환경을 제공함으로써 설계 효율성을 증진시킨다. 본 논문에서는 이러한 효용을 달성하기 위한 MDO 프레임웍(framework)을 제시하고 프레임웍 설계의 논리적 근저와 타당성을 밝힌다. 본 논문에서 제안하는 다분야 통합 최적화를 위한 분산형 지능 시스템인 DisMDO는 사용자가 GUI를 동해서 편리하게 다분야통합최적화 문제를 해결할 수 있도록 지원하며, 제공되는 스크립트 언어를 동해서도 이를 정의할 수 있도록 지원하여 일괄처리도 가능하도록 한다. 또한, 집중화된 데이터베이스를 관리하여 다분야 전문가들이 공통의 데이터를 안전하게 공유할 수 있도록 지원하며, 외부에서 제공되는 해석 도구나 최적화 모듈을 손쉽게 프레임웍에 통합시킬 수 있도록 하는 인터페이스 제작기(factory) 기능을 제공한다.ackscattering spectroscopy, X-ray diffraction, secondary electron microscopy, atomic force microscoy, $\alpha$-step, Raman scattering spectroscopu, Fourier transform infrared spectroscopy 및 micro hardness tester를 이용하여 기판 bias 전압이 DLC 박막의 특성에 미치는 영향을 조사하였다. 분석결과 본 연구에서 제작된 DLC 박막은 탄소와 수소만으로 구성되어 있으며, 비정질 상태임을 알 수 있었다. 기판 bias 전압의 증가에 따라 박막의 두께가 감소됨을 알 수 있었고, -150V에서는 박막이 거의 만들어지지 않았으며, -200V에서는 기판 표면이 식각되었다. 이것은 기판 bias 전압과 ECR 플라즈마에 의한 이온충돌 효과 때문으로 판단되며, 150V 이하에서는 증착되는 양보다 re-sputtering 되는 양이 더 많을 것으로 생각된다. 기판 bias 전압을 증가시킬수록 플라즈마에 의한 이온충돌 현상이 두드러져 탄소와 결합하고 있던 수소원자들이 떨어져 나가는 탈수소화 (dehydrogenation) 현상을 확인할 수 있었으며, 이것은 C-H 결합에너지가 C-C 결합이나 C=C 결합보다 약하여 수소 원자가 비교적 해리가 잘되므로 이러한 현상이 일어난다고 판단된다. 결합이 끊어진 탄소 원자들은 다른 탄소원자들과 결합하여 3차원적 cross-link를 형성시켜 나가면서 내부 압축응력을 증가시키는 것으로 알려져 있으며, hardness 시험 결과로 이것을 확인할 수 있었다. 그리고 표면거칠기는 기판 bias 전압을 증가시킬수록 더 smooth 해짐을 확인하였다.인하였다.을 알 수 있었다. 즉 계면에서의 반응에 의해 편석되는 Ga에 의해 박막의 strain이 이완되면, pinhole 등의 박막결함

  • PDF

Properties of CIGS thin film developed with evaporation system (진공증발원 시스템을 이용한 CIGS 박막의 특성평가에 관한 연구)

  • Kim, Eundo;Jeong, Ye-Sul;Jung, Da Woon;Eom, Gi Seog;Hwang, Do Weon;Cho, Seong Jin
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.85.1-85.1
    • /
    • 2010
  • $Cu(In,Ga)Se_2$ (CIGS) thin film solar cell is currently 19.5% higher efficiency and developing a large area technology. The structure of CIGS solar cell that make five unit layers as back contact, light absorption, buffer, front transparent conducting electrode and antireflection to make them sequentially forming. Materials and various compositions of thin film unit which also manufacture a variety method used by the physical and chemical method for CIGS solar cell. The construction and performance test of evaporator for CIGS thin film solar cell has been done. The vapor pressures were changed by using vapor flux meter. The vapor pressure were copper (Cu) $2.1{\times}10^{-7}{\sim}3.0{\times}10^{-7}$ Torr, indium (In) $8.0{\times}10^{-7}{\sim}9.0{\times}10^{-7}$ Torr, gallium (Ga) $1.4{\times}10^{-7}{\sim}2.8{\times}10^{-7}$ Torr, and selenium (Se) $2.1{\times}10^{-6}{\sim}3.2{\times}10^{-6}$ Torr, respectively. The characteristics of the CIGS thin film was investigated by using X-ray diffraction (XRD), scanning electron microscopy/energy dispersive spectroscopy (SEM/EDS) and photoluminescence (PL) spectroscopy using a He-Ne laser. In PL spectrum, temperature dependencies of PL spectra were measured at 1137 nm wavelength.

  • PDF

Quality assurance algorithm using fuzzy reasoning for resistance spot weldings (퍼지추론을 이용한 저항 점용접부위의 품질평가 알고리듬)

  • Kim, Joo-Seok;Lee, Jae-Ik;Lee, Sang-ryong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.22 no.3
    • /
    • pp.644-653
    • /
    • 1998
  • In resistance spot weld, the assurance of weld quality has been a long-standing problem. Since the weld nuggets if resustance spot welding form between the workpieces, visual detection of defects in usually impossible. Welding quality of resistance spot welding can be verified by non destructive and destructive inspections such as X-Ray inspection and testing of weld strength. But these tests, in addition to being time-consuming and costly, can entail risks due to sampling basis. The purpose of this study is the development of the monitoring system based on fuzzy inference, aimed at diagonosis of quality in resistance spot welding. The fuzzy inference system consists of fuzzy input variables, fuzzy membership functions and fuzzy rules. For inferring the welding quality(strength), the experimental data of the spot welding were acquired in various welding conditions with the monitoring system designed. Some fuzzy input variables-maximum, slop and difference values of electrode movement signals-were extracted from the experimental data. It was confirmed that the fuzzy inference values of strength have a .${\pm}$5% error in comparison with actual values for the selected welding conditions(9-10.5KA, 10-14 cycle, 250-300 $kg_f$). This monitoring system can be useful in improving the quality assurance and reliability of the resistance spot welding process.

Production and Application of the Dose Calculation Program which used MS EXCEL and Bit System (MS EXCEL 및 Bit system을 이용한 피부선량 계산 프로그램의 제작 및 응용)

  • Kim, Sung-Chul;Kim, Chong-Yeal
    • Journal of radiological science and technology
    • /
    • v.32 no.1
    • /
    • pp.39-43
    • /
    • 2009
  • The medical diagnostic examination using ionizing radiation has improved the patients' life and brought revolution in medical examination along with the mechanical development. However, the development of medical imaging systems has also been the reason to increase the patients' exposure for ionizing radiation. ICRP recommends that each country adopts diagnostic reference levels depending on regional and national situations. The Korea Food & Drug Administration suggested the dosimetry measurement guideline for patients in 2007. Nonetheless, in reality, it is hard to know the skin dose of the patients when applying a x-ray since there is no radiation dosimeter in most of clinical situation. Therefore, this study sets a program based on the bit system to figure out easily the skin dose of a patients using MS Excel program in the PC setting. The results showed 10% better outcome.

  • PDF

Fabrication and Characterization of Porous Silicon-based Urea Sensor Syst (다공질 실리콘을 이용한 요소검출용 바이오 센서 제작)

  • Jin, Joon-Hyung;Kang, Chul-Goo;Kang, Moon-Sik;Song, Min-Jung;Min, Nam-Ki;Hong, Seok-In
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.2003-2005
    • /
    • 2002
  • 바이오 마이크로 시스템 및 바이오 MEMS 분야, 특히 실리콘을 기질로 하는 바이오 센서 제작에서 반도체 공정 기술은 센서의 대량 생산과 초소형화를 위해서 반드시 필요한 기술이다. 그러나, 감지전극의 마이크로화에 따른 센서의 감도 및 안정성 저하 문제는 해결해야 할 과제이다. 최근, 다공질 실리콘이 갖는 대면적이 실리콘 기질과 생체 고분자 (예: 단백질, 핵산 등) 간의 결합력을 향상시킬 수 있음이 알려지면서, 바이오 센서 분야에서, 새로운 형태의 드랜스듀서 재료로서의 다공질 실리콘에 대한 논의가 활발히 전개되고 있으며 또한, ISFET (Ion-Selective Field-Effect Transistors) 와는 달리 다공질 실리콘 층은 저항이 크기 때문에 센서 제작 과정에서의 부가적인 절연막을 필요로 하지 않는다. 본 연구에서는, 백금을 증착한 다공질 실리콘 표면에 전도성 고분자로서 Polypyrrole (PPy) 필름과 생체 고분자 물질로서 Urease를 각각 전기화학적으로 흡착하였다. 다공질 실리콘 층의 형성을 위해 테플론 소재의 전기화학 전지에 불산 (49%), 에탄올 (95%), $H_2O$ 혼합 용액을 넣고 실리콘 웨이퍼에 일정시간 수 mA의 산화 전류를 흘려주었으며, 약 $200{\AA}$의 티타늄 박막과 $200{\AA}$의 백금 박막을 RF 스퍼터링하여 작업 전극을 제작하였고, 백금 박막 및 Ag를 기화 증착하여 제작한 Ag/AgCl 박막을 각각 상대 전극과 기준전극으로 하였다. 박막 전극의 표면 분석을 위해 SEM (Scanning Electron Microscopy), EDX (Energy Dispersive X-ray spectroscopy) 등을 이용하였다. 제작된 요소 센서로부터 요소 농도 범위 0.01 mmol/L ${\sim}$ 100 mmol/L에서 약 0.2 mA/decade의 감도를 얻었다.

  • PDF

Smart Glasses Cannula Guide System Development for Interventional Cardiology Procedures (중재적 심장 질환 시술을 위한 스마트 글래스 삽입관 가이드 시스템 개발)

  • Jang, Ik Gyu;Heo, Yeong Jun;Jeon, Geum Sang;Choi, Jaesoon
    • Journal of Biomedical Engineering Research
    • /
    • v.41 no.5
    • /
    • pp.173-178
    • /
    • 2020
  • Remote control intervention surgery robotic system improves treatment effect on cardiovascular patients and reduces X-ray exposure. However, at the time of the first procedure, CT (computerized tomography) and other ultrasound diagnostic equipment should be used because the operator must insert the cannula directly into the patient's leg. Improvements to this have been un-met-needs of hospitals. In this paper, we developed a system that can insert the cannula intuitively and quickly by displaying blood vessels at a glance through the system using smart wearable glasses. The core development method is as follows. In order to project augmented reality onto the surgical image, CT scan angiography image is extracted and processed. In the process, three CT-Markers are used to create a coordinate system of blood vessel images. Additionally, a reference marker is photographed on a single camera to obtain a camera coordinate system. Since the CT marker and the reference marker are in the same position, 3D registration is performed. In the text, a detailed explanation will be given.

Study on Radiation Dose in the Medical Image Data Display Method - Focused on the DICOM Standard (의료영상 데이터에서의 피폭선량 표시 방법에 관한 고찰: DICOM 표준을 중심으로)

  • Kim, Jung-Su
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.483-489
    • /
    • 2015
  • DICOM (Digital Imaging and Communications in Medicine) standards are generally introduced as de facto and de jure standards in modern medical imaging devices to store and to transmit medical image information. DICOM Dose Structured Report (DICOM dose SR) is implemented to report radiation exposure information in image acquiring process. and DIOCM Modality Performed Procedure Step (DICOM MPPS) is also partly used to report this exposure with the information in its DICOM tag. This article is focused on three type of radiation exposure information of DICOM standards, 1) DICOM dose SR, 2) DICOM MPPS and 3) Radiation Exposure Monitoring(REM) profile by Integrating the Healthcare Enterprise(IHE), to study on radiation exposure reporting. Healthcare facility and its staff of medical imaging related to radiation exposure should have a deep understanding of radiation exposure, and it required a standards to enhance the quality control of medical imaging and the safety of patients and staffs. Staff member have to pay attention on radiation exposures and controling processes from the purchasing stage of X-ray devices.

Theoretical Studies on the Biochemical Roles of Zn (Zn 의 생화학적 역할에 관한 이론적 연구)

  • Kim, Ho Sun;Kim, Gwang Su
    • Journal of the Korean Chemical Society
    • /
    • v.34 no.3
    • /
    • pp.232-238
    • /
    • 1990
  • To study the biological roles of Zn, we investigated simple model systems of $Zn^{++}, coordinated with OH_2 or NH_3,$ or with O=C- in peptide. The geometrical structures and net atomic charges were calculated by the ab initio HF-SCF theory using double zeta basis sets. The ligands of O-H, N-H, and O=C- are very polar due to $Zn^{++}$. Therefore, the carbon atom in peptide becomes so electrophilic that it can be easily attacked by other nucleophiles. In addition, to understand how $Zn^{++}$ is coordinated with ligands in enzyme, a molecular mechanics method is applied to the system of the enzyme of carboxypeptidase A (CPA) with the substrate of glycyltyrosine. From our results, it appears that the Zn ion is coordinated not only by four ligands in enzyme and substrate but also by one water molecule.

  • PDF