• Title/Summary/Keyword: X-ray 분석

Search Result 3,513, Processing Time 0.036 seconds

Pigment Analysis for Wall Paintings According to Verification of Penetration Depth for X-ray: Ssanggyesa Daeungjeon (Main Hall of Ssanggyesa Temple) in Nonsan (X-선 투과깊이 검증에 따른 벽화 안료의 정밀분석: 논산 쌍계사 대웅전)

  • Chun, Yu-Gun;Lee, Chan-Hee
    • Journal of Conservation Science
    • /
    • v.27 no.3
    • /
    • pp.269-276
    • /
    • 2011
  • We have suggested effective P-XRF analysis method for pigment painting layer by calculating penetration depth of X-ray. This experiment calculated that X-ray generated from P-XRF was possible penetration until 1.17mm deep in the pigment painting. Based on the experimental results, analysis for eight color pigments on wall paintings in Ssanggyesa Main Hall, most pigments were painted traditional pigments. However pigments on recently restorated wall painting were used synthetic modern pigments.

Modern Sphinx: X-ray Inspection Technology for Customs (현대판 스핑크스: 국경의 관문을 지키는 X-ray 판독 기술)

  • Lee, J.W.;Moon, T.J.
    • Electronics and Telecommunications Trends
    • /
    • v.35 no.6
    • /
    • pp.37-47
    • /
    • 2020
  • Today, the volume of international trade by airplanes and ships is rapidly increasing, and the volume of trade over land is expected to increase as inter-Korean relations change. In customs processes, humans inspect using the naked eye; therefore, computer vision technology can be used to assist customs inspectors responsible for X-ray security screening. In particular, because of recent advances in deep learning technology, algorithms for image understanding and object detection performance are improving, and studies on their application to X-ray screening have been published. This manuscript describes trends in artificial intelligence X-ray image-reading technology to detect prohibited items. X-ray inspection AI technology is similar to the Sphinx, which was the guardian of the pyramids in ancient Egyptian mythology.

최근의 X-ray 리소그래피 기술개발 현황

  • Yu, Hyeong-Jun;Hwang, Ho-Jun;Lee, Byeng-Chul;Yun, Chang-Joo
    • Electronics and Telecommunications Trends
    • /
    • v.5 no.3
    • /
    • pp.14-31
    • /
    • 1990
  • 반도체기술의 발전에 따라 보다 정교한 리소그래피 기술이 요구되고 있으며, x-ray 리소그래피 기술이 다음 세대 리소그래피 기술로 활발히 연구되고 있다. 특히 최근 리소그래피 전용 compact synchrotron 등 관련분야 기술발전에 힘입어 x-ray 리소그래피는 막대한 초기투자에도 불구하고, 전체적으로는 경쟁력을 확보하는 수준에 이르렀으며, 실용화 가능성이 한층 높아졌다. 그러나 아직도 마스크 및 resist 등 해결하여야 할 문제가 많이 남아 있다. 본 고에서는 주로 '80년대 후반에 이루어진 x-ray 리소그래피 기술의 연구개발 현황을 정리하였다. 특히 미국, 일본, 유럽에서의 개괄적인 연구개발 현황과, 고출력 x-ray 광원으로서 실용화에 성큼 다가선 compact synchrotron의 개발현황, x-ray 리소그래피 기술의 핵심중의 하나인 x-ray 마스크 기술개발 현황 등을 중심으로 기술하였다.

Determination of Thin Film Thickness by EDS Analysis and its Modeling (EDS 분석과 모델링에 의한 박막두께 측정 방법에 관한 연구)

  • Yun, Jae-Jin;Lee, Won-Jong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.8
    • /
    • pp.647-653
    • /
    • 2011
  • In this study, a method to measure the thickness of thin film by EDS (energy dispersive spectroscopy) is suggested. We have developed a model which calculates the thickness of thin film from the characteristic x-ray intensity ratio of the elements in thin film and substrate by considering incident electron beam energy, x-ray generation curve, backscattering and absorption of x-ray, take-off angle of x-ray and tilt angle of the sample. We obtained the relation curve between the film thickness measured experimentally and the x-ray intensity ratio of elements. The film thicknesses calculated from the model agrees quite well with those measured experimentally. Therefore, the thin film thickness can be measured rapidly and accurately by using the model developed in this study and the x-ray intensity ratio obtained in EDS analysis.

ZVS Phase-Shift Full-Bridge Inverter for 100kV High Voltage Output of X-ray driving Circuit (X-ray 구동회로의 100kV 고전압 출력을 위한 ZVS Phase-shift Full-Bridge 인버터)

  • Kang, Kyung-soo;Kim, Se-min;Kim, Sang-Yeon;Lee, Jeong-jun;Roh, Chung-Wook
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.355-356
    • /
    • 2016
  • 기존 X-ray용 인버터의 경우, 일반적인 Full-bridge 인버터를 사용하여 낮은 효율이 발생하기 때문에 1.6kW이상의 고전압 출력을 요구하는 X-ray를 사용할 수 없는 문제점이 있다. 본 논문은 X-ray 구동용 인버터의 높은 출력이 가능한 고전압 출력용 ZVS Phase-Shift Full Bridge 인버터를 제안한다. 기존의 X-ray 구동용 인버터를 사용할 경우에는 낮은 효율 및 높은 출력 전압을 발생 시킬 수 없기 때문에 X-ray 발생이 어려우며, 높은 출력을 발생시키기 위해서는 회로의 전체적인 부피가 커지고 제작단가가 증가하는 단점이 있다. 반면 제안된 회로는 X-ray 구동용 ZVS Phase-Shift Full Bridge 인버터로써, 영전압 스위칭을 통해 높은 효율로 인버터 구동이 가능하고, 높은 출력 전압을 발생 시킬 수 있기 때문에 회로의 소형화 및 고출력 X-ray 발생이 가능한 장점을 갖는다. 본 논문에서는 제안된 회로의 이론적인 특성을 분석하고 모의실험을 통해 확인하였으며, 1.6kW급 X-ray 구동 인버터 회로에 적용하여 실험을 통해 우수성을 검증하였다.

  • PDF

The Measurement and Analysis by Free Space Scatter Dose Distribution of Diagnostic Radiology Mobile Examination Area (영상의학과 이동검사 영역의 공간선량 분포에 대한 측정 및 분석)

  • Kim, Sung-Kyu;Son, Sang-Hyuk
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.11 no.1
    • /
    • pp.5-13
    • /
    • 2009
  • There are several reasons to take X-ray in case of inpatients. Some of them who cannot ambulate or have any risk if move are taken portable X-ray at their wards. Usually, in this case, many other people-patients unneeded X-ray test, family, hospital workers etc-are indirectly exposed to X-ray by scatter ray. For that reason I try to be aware of free space scatter dose accurately and make the point at issue of portable X-ray better in this study. kVp dose meter is used for efficiency management of portable X-ray equipment. Mobile X-ray equipment, ionization chamber, electrometer, solid water phantom are used for measuring of free space scatter dose. First of all the same surroundings condition is made as taken real portable X-ray, inquired amount of X-ray both chest AP and abdomen AP most frequently examined and measured scatter ray distribution of two tests individually changing distance. In the result of measuring horizontal distribution with condition of chest AP it is found that the mAs is decreased as law of distance reverse square but no showed mAs change according to direction. Vertical distribution showed the mAs slightly higher than horizontal distribution but it isnt found out statistical characteristic. In abdomen AP, compare with chest AP, free space scatter dose is as higher as five-hundred times and horizontal, vertical distribution are quite similar to chest AP in result. In portable X-ray test, in order to reduce the secondary exposure by free space scatter dose first, cut down unnecessary portable order the second, set up the specific area at individual ward for the test the third, when moving to a ward for the X-ray test prepare a portable shielding screen. The last, expose about 2m apart from patients if unable to do above three ways.

  • PDF

Fabrication and Characterization of Array Type of Single Photon Counting Digital X-ray Detector (Array Type의 Single Photon Counting Digital X-ray Detector의 제작 및 특성 평가)

  • Seo, Jung-Ho;Lim, Hyun-Woo;Park, Jin-Goo;Huh, Young;Jeon, Sung-Chea;Kim, Bong-Hui
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.32-32
    • /
    • 2008
  • X-ray detector는 의료용, 산업용 등 다양한 분야에서 사용되어지고 있으며 기존의 Analog X-ray 방식의 환경오염, 저장공간 부족, 실시간 분석의 어려움 등의 문제점들을 해결하기 위하여 Digital X-ray로의 전환과 연구가 활발하며 이에 따른 관심도 높아지고 있는 살점이다. Digital X-ray detector는 p-영역과 n-영역 사이에 아무런 불순물을 도핑하지 않은 진성반도체(intrinsic semiconductor) 층을 접합시킨 이종접합 PIN 구조의 photodiode 이다. 이 소자는 역바이어스를 가해주면 p영역과 n영역 사이에서 캐리어 (carrier)가 존재하지 않는 공핍 영역이 발생하게 된다. 이런 공핍 영역에서 광흡수가 일어나면, 전자-정공 쌍이 발생한다. 그리고, 발생한 전자-정공 쌍에 전압이 역방향으로 인가되는 경우, 전자는 양의 전극으로 이동하고, 정공은 음의 전극으로 이동한다. 이와 같이, 발생한 캐리어들을 검출하여 전기적인 신호로 변환 시킨다. 고해상도의 Digital X-ray detector를 만들기 위해서는 누설전류에 의한 noise 감소와 소자의 높은 안정성과 내구성을 위한 높은 breakdown voltage를 가져야 한다. 본 연구에서는 Digital X-ray detector의 leakage current 감소와 breakdown voltage를 높이기 위하여 guradring과 gettering technology를 사용하여 전기적 특성을 분석하였다. 기판으로는 $10k\Omega{\cdot}cm$ resistivity를 갖으며, n-type <111>인 1mm 두께의 4인치 Si wafer를 사용하였다. 그리고 pixel pitch는 $100{\mu}m$이며 active area는 $80{\mu}m{\times}80{\mu}m$$32\times32$ array를 형성하여 X-ray를 조사하여 소자의 특성을 평가 하였다.

  • PDF

The Effect of Applying the X-ray Screening Ability Rating for Security Screening Persons in Incheon International Airport (인천국제공항 보안검색요원 X-ray 판독등급제 적용 효과)

  • Yung-Kil Lee;Jeong-Sun Baek;Dong-Min Kim
    • Journal of Advanced Navigation Technology
    • /
    • v.27 no.6
    • /
    • pp.733-739
    • /
    • 2023
  • The purpose of this study verify to the effect of applying the X-ray screening ability rating for security screening persons in Incheon International Airport. Data collected through a evaluation score of 1,034 security screening persons in Incheon International Airport. Data analysis performed using paired sample t-test. The research results found that it was a statistically significant difference pre-test and post-test applying the X-ray screening ability rating. In this article, we asserts that the X-ray screening ability rating is effective in improving the X-ray screening ability of security screening persons. This paper contribute to the academic expansion of motivation theory and self-determination theory. This study is valuable as a preemptive empirical research that provides practical implications about the application of X-ray screening ability rating for security screening persons.

A Study of Mineral Quantification on Clay-Rich Rocks (점토질 암석의 광물정량 분석법 연구)

  • Byeong-Kook, Son;Gi-O, An
    • Korean Journal of Mineralogy and Petrology
    • /
    • v.35 no.4
    • /
    • pp.431-445
    • /
    • 2022
  • A quantitative phase analysis method of X-ray powder diffraction was studied to determine the mineral content of clay-rich rocks practically as well as effectively. For quantitative X-ray powder diffraction analysis of the clay-rich rocks, it is necessary to prepare whole-rock powder samples with a random orientation by side mounting method. In addition, for the identification of the clay minerals in the rock, it is required to prepare an oriented mount specimen with a clay particle size of 2 ㎛ or less, ethylene glycol treatment, and heat treatment. RIR (reference intensity ratio) and Rietveld method were used for the quantitative analysis of the clay-rich rocks. It was possible to obtain the total clay and the non-clay minerals contents from the whole-rock X-ray diffraction profiles using the RIR values. In addition, it was possible to calculate the relative content of each clay mineral from the oriented X-ray diffraction profiles of the clay particle size and assign it to the total clay. In the Rietveld method of whole-rock X-ray diffraction, effective quantitative values were obtained from the Rietveld diffraction patterns excluded the region of less than 10 degrees (2θ). Similar quantitative values were shown in not only the RIR but the Rietveld methods. Therefore, the analysis results indicate a possibility of a routine quantitative analysis of clay-rich rocks in the laboratory. However, quantitative analysis of clay minerals is still a challenge because there are numerous varieties of clay minerals with different chemical and structural characteristics.

Measurement of Spinal Curvature by Using Enhanced Hough Transform on X-ray Imaging (X-ray 영상에서 개선된 허프 변환을 이용한 척추만곡도 측정)

  • Jeong, Hyang su;Kim, Kwang Beak
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.05a
    • /
    • pp.360-362
    • /
    • 2018
  • 본 논문에서는 X-ray 영상에서 척추 영역을 추출 및 분석하여 척추만곡도를 자동으로 측정하는 방법을 제안한다. 제안된 방법은 X-ray 영상에서 어깨뼈와 골반뼈 등과 같이 필요 없는 영역을 제거한 ROI(Region of Interest) 영역을 추출하고, 추출된 ROI 영역에서 척추 에지를 검출하기 위해 가우시안-라플라시안(Laplacian of Gaussian) 필터를 적용하여 척추 에지를 검출한다. 추출된 척추 영역을 척추의 Apex를 기준으로 Above Apex와 Below Apex 영역으로 구분하고 허프 변환(Hough Transform) 기법을 적용하여 두 영역에 대한 ($r,{\theta}$) 허프 공간을 구한다. ($r,{\theta}$) 허프 공간에서 척추만곡도 측정에 필요한 수평 직선만을 검출하기 위하여 수직 직선을 나타내는 교점들의 영역을 제거하여 척추만곡도 측정에 필요한 영역을 추출한다. 제안된 척추 추출 방법을 다양한 X-ray 영상을 대상으로 실험한 결과, 전문의가 척추만곡도를 효과적으로 측정하고 분석할 수 있는 척추 영역이 추출된 것을 확인할 수 있었다.

  • PDF