• Title/Summary/Keyword: X-factor

Search Result 2,447, Processing Time 0.025 seconds

Effect of Cobalt Substitution on the Magnetic Properties of NiZnCu Ferrite for Multilayer Chip Inductors (Cobalt 치환된 칩인덕터용 NiZnCu Ferrite의 자기적 특성 연구)

  • An, Sung-Yong;Kim, Ic-Seob;Son, Soo-Hwan;Song, So-Yeon;Hahn, Jin-Woo;Choi, Kang-Ryong
    • Journal of the Korean Magnetics Society
    • /
    • v.20 no.5
    • /
    • pp.182-186
    • /
    • 2010
  • Effect of cobalt substitution on the sintering behavior and magnetic properties of a NiZnCu ferrite was studied. $Ni_{0.36-x}Co_xZn_{0.44}Cu_{0.22}Fe_{1.98}O_4(0{\leq}x{\leq}0.04)$ ferrite was fabricated by a solid stat reaction method. It was proposed and experimentally verified that $Co^{2+}$ substituted NiZnCu ferrite was effective on improving the quality factor and magnetic properties of NiZnCu ferrites for multilayer chip inductors. The ferrite was sintered without sintering aids, at $880{\sim}920^{\circ}C$, for 2 h and the initial permeability, quality factor, density, shrinkage, saturation magnetization, and coercivity were also measured. The quality factor (Q) was increased linearly up to x = 0.01 and decreased rapidly over x = 0.01. As the cobalt content increased, the initial permeability and density of the ferrites decreases. The initial permeability of toroidal sample for $Ni_{0.35}Co_{0.01}Zn_{0.44}Cu_{0.22}Fe_{1.98}O_4$ ferrites sintered at $900^{\circ}C$ was 130 at 1 MHz and quality factor was 230.

The Effect of Wear ing Spandex Wear with Compression Band on Biomechanical Parameters during a Golf Drive Swing (골프 드라이브 스윙 시 압축 밴드를 적용한 기능성 의류가 신체의 운동역학적 변인에 미치는 영향)

  • Chae, Woen-Sik;Kang, Nyeon-Ju
    • Korean Journal of Applied Biomechanics
    • /
    • v.21 no.3
    • /
    • pp.345-352
    • /
    • 2011
  • The purpose of this study was to determine how spandex wear with compressive band affects biomechanical parameters during a golf swing. Nine male golf players, each with at least 6 years golf experienc(handy 4.5${\pm}$5.4), were recruited as the participants. Eight pairs of surface electrodes were attached to the left and right side of the body to monitor the pectoralis major(PM), external abdominal oblique(AO), erector spinae(ES), and vastus lateralis(VL). This study showed that the angular velocity of the club in EG were increased during the down swing phase but X-Factor and X-factor Stretch were reduced. Average and maximum nEMG (normalized EMG) values of the left AO(external abdominal oblique) were less in EG(experimental group) compared with CG(control group) during the back swing, whereas those of left PM(pectoralis major) in EG were greater than CG. It is more likely that EG performed effectively golf swing without excess muscle activity. Thus, the spandex wear with compressive band played an important role in improving swing performance with injury prevention. This has led to suggestions of the need for further kinetic and kinematic analyses to evaluate its function.

Effects of Kurtosis on the Flow Factors Using Average Flow Model (Average Flow Model을 이용한 Kurtosis에 따른 Flow Factors에 관한 연구)

  • 강민호;김태완;구영필;조용주
    • Tribology and Lubricants
    • /
    • v.17 no.3
    • /
    • pp.236-243
    • /
    • 2001
  • In this study, flow factors are evaluated in terms of kurtosis using random rough surface generated numerically. As h/$\sigma$become large ø$\sub$x/, ø$\sub$y/, ø$\sub$fp/, approach to 1 and ø$\sub$s/, ø$\sub$fs/ to 0 asymptotically regardless of kurtosis. ø$\sub$x/, ø$\sub$y/, ø$\sub$fp/ increase with increasing kurtosis in the mixed lubrication regime. ø$\sub$s/, ø$\sub$fs/ is associated with an additional flow transport due to the combined effect of sliding and roughness. As h/$\sigma$ decreases ø$\sub$s/, ø$\sub$fs/ increase up to a certain point, and then decrease toward zero. This behavior can be attributed to the increasing number of contacts in the mixed lubrication regime. ø$\sub$x/ in the presence of elastic deformation on the surface is larger than ø$\sub$x/ in the absence of it because local film thickness(h$\sub$T/) increases by elastic deformation.

A Study on Overexposure Rate according to Overdensity in Chest X-ray Radiography(II) (흉부촬영에서 overdensity에 따른 overexposure rate를 아는 방법(II))

  • Kim, Jung-Min;Huo, Joon;Hayashi, Taro
    • Journal of radiological science and technology
    • /
    • v.23 no.1
    • /
    • pp.13-19
    • /
    • 2000
  • We have presented with the "A study on overexposure rate according to over-density in chest X-ray radiography(I)" last year. In this report, We could calculate the entrance skin dose from chest X-ray film density the formula $I_0=Ix/e^{-{\mu}x}{\times}mG$, (mG is Bucky factor) was used to deliver the skin dose. At that time, There was two problems that the Bucky factor from maker was not equal to field experience and the field size influenced on the Attenuation Rate. The experiment of Bucky factor was done from film method and retried the Attenuation Rate of Acryle phantom according to Good & Poor geometry. As the results, The Bucky factor from maker higher than in this experiments $30{\sim}40%$. The Attenuation Rate in good geometric condition brings about a little alteration compare with poor geometric condition. In the field experiment, we could get the chest image with very low entrance skin radiation dose $29.3{\mu}Sv$, especially with air gap methode, the entrance skin dose was detected $10{\mu}Sv$.

  • PDF

A Hardware Implementation and Performance Analysis of STS Diversity System for CDMA2000 1x Environment (CDMA2000 1x 환경을 위한 STS(Space Time Spreading) 다이버시티 시스템의 하드웨어 구현 및 성능 분석)

  • 박재현;최승원;남상원
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.11
    • /
    • pp.1134-1142
    • /
    • 2003
  • This paper presents a hardware implementation of the STS diversity system, utilizing FPGAs and introduces the function and the design method of each of the modules of the system. In order to improve the performance of the implemented STS system which is an open loop transmit diversity system under fading environment, the exact estimation of the communication channel is essential. Therefore, we propose the optimal forgetting factor to estimate pilot channel in this paper, It is shown in this paper that the pilot channel is estimated using the forgetting factor of 0.7 without increasing the integration range of the pilot channel even when the power of pilot channel is not sufficiently large in CDMA 2000 1x signal environment.

Effect of Rehabilitation Exercise for Golfers on the X-factor and Ground Reaction Force according to Phase of the Golf Swing

  • yoon, Junggyu;Cho, Byungyun
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.10 no.1
    • /
    • pp.1706-1710
    • /
    • 2019
  • Background: Despite frequent shoulder injuries of rotator cuff muscle of golfers by the result of overuse and poor swing mechanics, there is little research on shoulder specific rehabilitation exercises for injured rotator cuff muscle and golf swing Objective: To examined the effect of rehabilitation exercise for golfers on the X factor and ground reaction force (GRF) according to phase of the golf swing. Design: Crossover study Methods: The participants were 13 amateur golfers selected for a 4 week rehabilitation exercise for golfers. A rehabilitation exercise for golfers consisting of 5 steps and 4 items (sleeper stretch, full side plank, push up to plank, high plank knee unders) were applied to all participants. A three dimensional motion analyzer and force platform (SMART-E, BTS, Italy) were used to measure the X factor (angle between shoulder and pelvis at top of back swing) and GRF according to phase of the golf swing. All dependent variables were measured before and after exercise. The collected data was analyzed using the paired t test and SPSS 21.0. Results: The GRF had a statistically significant increase in the impact phase and ratio impact/weight after rehabilitation exercise for golfers (p<.05). The X-factor, GRF in top of back swing and finish were no significant differences between before and after exercise (p>.05). Conclusions: These results suggested that rehabilitation exercise for golfers was effective for increasing GRF in the impact phase and ratio impact/weight for amateur golfer.

Confirmatory Factor Analysis of the Environmental Health Engagement Profile (환경적 건강 관여 측정도구의 확인적 요인 분석)

  • Kim, Hyun-Kyoung
    • Korean Parent-Child Health Journal
    • /
    • v.17 no.1
    • /
    • pp.37-45
    • /
    • 2014
  • Purpose: This study aimed to review measurements of environmental health behavior and assess the construct validity of Environmental Health Engagement Profile (EHEP) through confirmatory factor analysis. Methods: The literature review was performed for selection of measurements. Confirmatory factor analysis with AMOS 19.0 was used for validation of EHEP. Results: The model fitness was not appropriate in the one-factor model; $x^2=91.11$ (df=5, p<.001), Comparative Fit Index (CFI)=8.19, Non Normed Fit Index (NNFI)=6.39, and Root Mean Square Error of Approximation (RMSEA)=0.20. The model fitness was appropriate in the two-factor model; $x^2=3.19$ (df=1, p=.074), CFI=9.95, NNFI= 9.71, RMSEA=0.07. A modification of scale was found to be the most suitable for use in the investigation of environmental health behavior. Conclusion: This study confirms that a two-factor model underlies the concept of environmental health behavior. The review of measurements can help nurses and researchers to assess the environmental health behaviors.

  • PDF

The Analysis of BMD in Forearm and Hip Joint with DEXA (DEXA에 의한 아래팔과 엉덩관절의 골밀도 분석)

  • Lee, Kwang-Sung;Park, Ui-Su;Jeon, Min-Cheol
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.3
    • /
    • pp.168-173
    • /
    • 2015
  • Use of forearm and hip joint bone density scan and find the clinical usefulness of the results that can be inferred as a result of any other region sites injured by a correction factor which if One part up. Groups of 60 patients, 10 patients by age 20-70 were composed of patients measured with the forearm and lumbar spine bone mineral density T-score and Z-score of the survey for each of the three factors that it was Find the correction factor to obtain the relationship. Bone mineral density of the correlation coefficient R = 0.8 correction factor is Y = 1.341X + 0.146. T-score of correlation coefficient R = 0.804 and the correction factor Y = 0.565X - 0.327 is Z-score of the correlation coefficient R = 0.637 correction factor Y = 0.539X - 0.225. It is regarded that there will be a clinical availability which can analogize the result of a part by using the result of the other part. It will be able to determine an auxiliary role in the clinical diagnosis. Correction factor to the equation Y = 1.341X + 0.146 is recommended.

Computation of Ionic Conductivity at NASICON Solid Electrolytes (II) Effects of mid-Na Sites on Na1-Na2 Conduction Paths (NASICON 고체 전해질의 이온 전도도 계산 (II) Na1-Na2 전도 경로에 미치는 mid-Na의 영향)

  • 최진삼;서양곤;강은태
    • Journal of the Korean Ceramic Society
    • /
    • v.32 no.11
    • /
    • pp.1292-1300
    • /
    • 1995
  • The ionic conductivity of NASICON solid electrolytes was simulated by using Monte Carlo Method (MCM). There were included two conduction paths: (1) Na1-Na2 and (2) Na1-Na2 including Na2-Na2. We assumed that mid-Na ions provde an additional driving force for Na mobile ions due to the interionic repulsion between Na1 and Na2 ions. The inflection point of vacancy availability factor, V has been shown at nearby x=2, the maximum mid-Na ions. The inflection point of vacancy availability factor, V has been shown at nearby x=2, the maximum mid-Na sites are occupied. The effective jump frequency factor, V has been shown at nearby x=2, the maximum mid-Na sites are occupied. The effective jump frequency factor, W increased rapidly with the composition at low temperature, but decreased at high temperature region. On Na1-Na2 conduction path, the minimum of charge correlation factor, fc and the maximum of $\sigma$T were appeared at x=2.0. this indicated that mid-Na ions affect on the high ionic conductivity behavior. At the whole range of NASICON composition, 1n $\sigma$T vs. 1/T* plots have been shown Arrhenius behavior but 1n (VWFc) vs. 1/T* have been shown the Arrhenius type tendency at x=2, which mid-Na is being the maximum. The results of MCM agreed with the experimental one when the chosen saddle point value was 6$\varepsilon$ : 3$\varepsilon$. Here the calculated characteristic parameter of materials, K and the phase transition temperature were -4.001$\times$103 and 178$^{\circ}C$ (1/T*=1.92, 1000/T=2.22), respectively.

  • PDF

A Study on Mante1-Haenszel Test of Conditional Independence ($2\times2$ 분할표를 이용한 조건부 독립성 검정)

  • 김지현;임현선
    • The Korean Journal of Applied Statistics
    • /
    • v.11 no.2
    • /
    • pp.257-268
    • /
    • 1998
  • Many epidemiological studies investigate whether an association exists between a binary risk factor X and a binary response variable Y. They analyse whether an observed association between X and Y persists when the level of another factor Z that might influence the association is controlled. This involves testing conditional independence of X and Y controlling for Z. The Mantel-Haenszel test is most widely used to test conditional independence for sparse tables. But if the association between X and Y varies along the levels of Z, Mantel-Haenszel test has a low power problem. In this study, we propose an alternative test procedure which overcomes the low power problem in that case. We find out the null distribution of the alternative test statistic and compare its performance with the Mantel-Haenszel test by simulation.

  • PDF