TSSG growth, morphology and properties of potassium lithium niobate (KLN) crystals

  • Chong, Tow-Chong;Xu, Xue-Wu;Li, Lian;Zhang, Guang-Yu;Kumagai, H.;Hirano, M.
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.9 no.4
    • /
    • pp.396-401
    • /
    • 1999
  • In the present paper, potassium lithium niobate(KLN) crystals have been grown along <001>, <100> and <110> directions by the top seeded solution growth (TSSG) method from Li-richer melts with different compositions. The morphologies of KLN crystals grown along different directions have been studied, and the well-developed facets have been unambiguously indexed using X-ray goniometer and stereographic projection analysis. The growth mechanism and defects such as cracks and inclusions were discussed on the basis of observations of facets on the crystal-solution interfaces. The crystal compositions were determined by a chemical analysis method. The structure and lattice constants of KLN crystals were determined and calculated on the basis of XRD data by using TREOR90 and PIRUM programs. The Curie temperature and optical absorption were determined by dielectric constant peak and spectrum measurements. respectively. The blue second harmonic generation (SHG) characteristics of KLN sample were also investigated using a pulsed dye laser.

  • PDF

Principles and Applications in Multileaf Collimator for Radiation Therapy (방사선치료에 있어서 Multileaf Collimator의 원리와 그 응용)

  • Chung, Kap-Soo
    • Journal of radiological science and technology
    • /
    • v.21 no.1
    • /
    • pp.24-28
    • /
    • 1998
  • A conventional treatment machine shapes x-ray fields by a set of dense metal collimators(jaws) built into the machine. These collimators are positioned by the therapist using hand controls in the treatment room, and usually remain stationary during treatment. The collimator jaws of treatment machines produce rectangular beams. Conventional beam shaping is accomplished through the use of a combination of these collimator jaws and secondary custom beam blocks attached to the accelerator beyond the collimator Jaws. The jaw positions for a particular field can be retrieved from a computer. One application of this increased capability is replacement of beam blocks for field-shaping with the MLC. There are three basic applications of the MLC. The first application is to replace conventional blocking. A second function of the MLC is related to conformal therapy, adjusting the field shape to match the beam's eye view projection of a planning target volume during treatment. The third application is the use of the MLC to achieve beam intensity modulation. The aim of this paper is to provide basic principle and to state fundamental concepts needed to implement the use of a multileaf collimator in the conventional clinical setting. The use of MLC field shaping is likely to save time and to incur a lower operating cost when compared to the use of beam blocks.

  • PDF

Changes of lateral cephalometric values according to the rotation of head (두부회전에 따른 측모두부방사선 계측치의 변화)

  • Kim, Kwang-Soo;Hwang, Mee-Sun;Choi, Eui-Hwan;Kim, Kwang-Won;Yoon, Young-Jooh
    • The korean journal of orthodontics
    • /
    • v.30 no.1 s.78
    • /
    • pp.53-66
    • /
    • 2000
  • This study was performed to find out the effect of projection errors on cephalometric linear and angular measurements according to head rotation during taking lateral cephalometric radiographs. Seventeen skulls with permanent dentition and no gross asymmetry were obtained from the Department of Anatomy, Medical School, Chosun University. Total 527 x-ray films were taken with $1^{\circ}$ interval from the reference position($0^{\circ}$) to ${\pm}15^{\circ}$ around the vertical axis (Z axis) which is perpendicular to the midpoint of the line connecting the center of two ear rods in submento-vertex direction. Statistical analysis was performed by paired t-test if there were statistically significant differences between the mean of the reference position($0^{\circ}$) and that of each rotation angle. The following results were obtained. 1. The projection errors of angular measurements were smaller than those of linear measurements. 2. The projection errors of angular measurements including midline landmarks were smaller than those including bilateral landmarks. 3. The horizontal linear measurements were gradually decreased when the stroll was rotated toward the film, but slightly increased and then decreased when the skull was rotated toward the focal spot. However, the changes were smaller in focal direction. 4. The projection errors of horizontal linear measurements were larger than those of vertical linear measurements. 5. The projection errors of vertical linear measurements were increased with increased distance from the rotation axis to vertical measurements. It is concluded that the use of angular measurements rather than linear measurements is recommended to minimize the projection errors.

  • PDF

Diagnostic Coincidence of Radiologic Measurement Methods of the Proximal Femur Anterior-posterior Projection for Assessment of Osteoporosis (근위대퇴부 정면 영상을 이용한 골다공증 평가 시 방사선적 계측의 진단일치도)

  • Kang, Yeong-Han;Cho, Kwang-Ho
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.6
    • /
    • pp.353-360
    • /
    • 2012
  • The purpose of this study was to determine whether there are relationships between radiologic parameters for osteoporosis by the proximal femur radiograhps and bone mineral density, as assessed by Dual Energy X-ray Absorptiometry(DEXA). Proximal femur anterior-posterior projection were taken from 112 individuals who undergoing DEXA. Radiographic parameters including canal-to-calcar ratio(CCR) and cortical thickness indices(CTI) were measured and compared with bone mineral density($g/cm^2$), T-score. The intramedullary femoral canal width(FW) and calcar width(CW) at osteoporosis group was significantly larger than that of control group. The CCR were correlated negatively with bone mineral density($g/cm^2$)(r=-0.340, p<0.01), and the CTI were correlated positively(r=0.624). The diagnostic accuracy of CCR for osteoporosis was 63.4%, and kappa value was 0.271. And the accuracy of CTI was 67.0%, and kappa value was the level of fair agreement(${\kappa}$=0.258). The proximal femur with large CCR and small CTI had lower T-scores. When evaluating proximal femur anterior-posterior radiographs, those patients with the thinnest femur diaphyseal cortices should be referred for further osteoporosis investigation.

Grid Noise Removal in Computed Radiography Images Using the Combined Wavelet Packet-Fourier Method (CR영상에서 웨이블릿 패킷-푸리에 방법을 이용한 그리드 잡음 제거)

  • Lee, A Young;Kim, Dong Youn
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.49 no.11
    • /
    • pp.175-182
    • /
    • 2012
  • The scattered radiation always occurs when X-ray strikes the object. To absorb the scattered X-rays, the antiscatter grids are used, however these grids images are superimposed in the projection radiography images. When those images are displayed on the monitor, moir$\acute{e}$ patterns are overlapped over the images and disturb the anatomical informations. Most of the researches performed to date removed the grid noises by calculating or observing those frequencies in one dimensional frequency domain, two dimensional wavelet transform or Fourier transform. Those methods filtered not only the grid noises but also diagnostic informations. In this paper, we proposed the combined wavelet packet-Fourier method to remove the grid artifact in CR images. For the phantom image, the proposed method achieved from 5.2 to 7.4 dB better than others in SNR and for CR images by rejecting the grid noise bands effectively while leaving the remaining bands unchanged, the loss of images could get minimal results.

Assessment of Radiation Dose Due to X-Ray Simple Series Examinations (X-선 단순 Series 촬영 시 피폭 선량 평가)

  • Gang, Eunbo;Hwang, Incheol;Shin, Woonjae
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.2
    • /
    • pp.81-88
    • /
    • 2014
  • In diagnostic radiology, each part is examined through serial radiography in most cases of general radiography. However, the reality is that, as for diagnostic reference level, measured values have been set up only for AP projection of each part and lateral projection. In the clinical setting, cumulative dose is incurred by serial radiography of patients, and this can make comparison of diagnostic reference level and cumulative exposure dose impossible or can lead to underestimation of diagnostic reference level. In this study, measurement of cumulative dose of serial radiography of each part revealed that when converting entrance surface dose to effective dose in case it is included in the exposure field, cumulative dose measured from a maximum of 38.06% to a minimum of 0.23% of individual dose limitation of the public. Also, when converting entrance surface dose of each part that is not included in the exposure field into effective dose, it measured from a maximum of 5% to a minimum of 0.04% of individual dose limitation of the public. Results of this study show entrance surface dose substantially increases in serial radiography of each part. Therefore, it is deemed that hospitals need to establish diagnostic reference level specifically, and subdivision of radiography orders for patients is also required in order to reduce unnecessary inspections. Moreover, the need of accurate exposure field is emphasized in case of inspection of several parts.

Study on Analysis for Factors Inducing the Whangryeong Mountain Landslide (황령산 산사태 원인 분석에 대한 연구)

  • 최정찬;백인성
    • The Journal of Engineering Geology
    • /
    • v.12 no.2
    • /
    • pp.137-150
    • /
    • 2002
  • Recently, plane failure mode occurred frequently along the bedding plane having low angle dip about 20 degree when cutting slopes were constructed in sedimentary rock region of the Gyeongsang Basin. Landslide of the Whangryeong Mountain which was occurred at Busan Metropolitan City in 1999 belongs to the category mentioned above. Reconstruction for cutting slope of the Whangryeong Mountain has finished in 2000 and final grade of reconstructed cutting slope is 1:2.0. To analyze slope failure mode for landslide of the Whangryeong Mountain, various analyses were performed such as in-situ investigation and test, drilling, laboratory test, aerial photograph interpretation, X-ray diffraction analysis, and slope stability analysis using Stereographic Projection and Limit Equilibrium methods. As the result, it is identified that tension cracks had been developed one year before the landslide took place. The tension crack semis to be formed by merging several joint sets. It appears that failure blocks broke down along the sliding planes of different layers. Risk of plane failure is conformed as a result of stability analysis using Stereographic Projection and Limit Equilibrium methods in case that greenish gray tuffaceous shales, regared as sliding planes, are weathered. From now on, a detailed investigation is needed for the thin layers which is sensitive to weathering, and stability analysis for this layer is performed at cut slope construction site having similar geological condition.

3D Histology Using the Synchrotron Radiation Propagation Phase Contrast Cryo-microCT (방사광 전파위상대조 동결미세단층촬영법을 활용한 3차원 조직학)

  • Kim, Ju-Heon;Han, Sung-Mi;Song, Hyun-Ouk;Seo, Youn-Kyung;Moon, Young-Suk;Kim, Hong-Tae
    • Anatomy & Biological Anthropology
    • /
    • v.31 no.4
    • /
    • pp.133-142
    • /
    • 2018
  • 3D histology is a imaging system for the 3D structural information of cells or tissues. The synchrotron radiation propagation phase contrast micro-CT has been used in 3D imaging methods. However, the simple phase contrast micro-CT did not give sufficient micro-structural information when the specimen contains soft elements, as is the case with many biomedical tissue samples. The purpose of this study is to develop a new technique to enhance the phase contrast effect for soft tissue imaging. Experiments were performed at the imaging beam lines of Pohang Accelerator Laboratory (PAL). The biomedical tissue samples under frozen state was mounted on a computer-controlled precision stage and rotated in $0.18^{\circ}$ increments through $180^{\circ}$. An X-ray shadow of a specimen was converted into a visual image on the surface of a CdWO4 scintillator that was magnified using a microscopic objective lens(X5 or X20) before being captured with a digital CCD camera. 3-dimensional volume images of the specimen were obtained by applying a filtered back-projection algorithm to the projection images using a software package OCTOPUS. Surface reconstruction and volume segmentation and rendering were performed were performed using Amira software. In this study, We found that synchrotron phase contrast imaging of frozen tissue samples has higher contrast power for soft tissue than that of non-frozen samples. In conclusion, synchrotron radiation propagation phase contrast cryo-microCT imaging offers a promising tool for non-destructive high resolution 3D histology.

A Study on Projection Angles for an Optimal Image of PNS Water's View on Children (유.소아 부비강 Water's 영상의 이상적 구현을 위한 촬영기준각도 변화에 관한 연구)

  • Son, Sang-Hyuk;Song, Young-Geun;Kim, Sung-Kyu;Hong, Sang-Woo;Kim, Je-Bong
    • Journal of radiological science and technology
    • /
    • v.30 no.2
    • /
    • pp.105-111
    • /
    • 2007
  • This study is to calculate the proper angle for the optimal image of PNS Water's view on children, comparing and analyzing the PNS Water's projection angles between children and adults at every age. This study randomly selected 50 patients who visited the Medical Center from January to May in 2005, and examined the incidence path of central ray, taking a PNS Water's and skull trans-Lat. view in Water's filming position while attaching a lead ball mark on the Orbit, EAM, and acanthion of the patients's skull. And then, we calculated the incidence angles(Angle A) of the line connected from OML and the petrous ridge to the inferior margin of maxilla on general(random) patients's skull image, following the incidence path of central ray. Finally, we analyzed two pieces of the graphs at ages, developing out the patients' ideal images at PNS Water's filming position taken by a digital camera, and calculating the angle(Angle B) between OML and IP(Image Plate). The angle between OML and IP is about $43^{\circ} in 4-years-old children, which is higher than $37^{\circ}, as age increases the angle decreases, it goes to $37^{\circ} around 30 years of age. That is similar result to maxillary growth period. We can get better quality of Water's image for children when taking the PNS Water's view if we change the projection angles, considering maxillary growth for patients in every age stage.

  • PDF

Patient Radiation Exposure Dose Evaluation of Whole Spine Scanography Due to Exposure Direction (Whole Spine Scanography의 검사방향에 따른 환자 선량 평가)

  • Kim, Jung-Su;Seo, Deok-Nam;Kwon, Soon-Mu;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.38 no.1
    • /
    • pp.1-6
    • /
    • 2015
  • Whole spine scanography (WSS) is a radiological examination that exposes the whole body of the individual being examined to x-ray radiation. WSS is often repeated during the treatment period, which results in a much greater radiation exposure than that in routine x-ray examinations. The aims of the current study were to evaluate the patient dose of WSS using computer simulation, image magnification and angulation of phantom image using different patient position. We evaluated the effective dose(ED) of 23 consecutive patients (M : F = 13:10) who underwent WSS, based on the automatic image pasting method for multiple exposure digital radiography. The Anterior-Posterior position(AP) and Posterior-Anterior position( PA) projection EDs were evaluated based on the PC based Monte Carlo simulation. We measured spine transverse process distance and angulation using DICOM measurement. For all patient, the average ED was 0.069 mSv for AP position and 0.0361 mSv for PA position. AP position calculated double exposure then PA position. For male patient, the average ED was 0.089 mSv(AP) and 0.050 mSv(PA). For female patient, the average ED was 0.0431 mSv(AP) and 0.026 mSv(PA). The transverse process of PA spine image measured 5% higher than AP but angulation of transverse process was no significant differences. In clinical practice, just by change the patient position was conformed to reduce the ED of patient. Therefor we need to redefine of protocol for digital radiography such as WSS. whole spine scanography, effective dose, patient exposure dose, exposure direction. protocol optimization.