• Title/Summary/Keyword: X-선

Search Result 3,810, Processing Time 0.029 seconds

The Importance of Positioning in General X-ray Examination: Based on Chest PA X-ray (일반엑스선 검사 시 위치 잡이의 중요성: 흉부엑스선 검사 중심으로)

  • Cho, Pyong-Kon
    • Journal of radiological science and technology
    • /
    • v.45 no.3
    • /
    • pp.249-254
    • /
    • 2022
  • The purpose of this study was to examine the importance of proper positioning in chest PA X-ray examination. As a study method, this author searched for and analyzed materials related to chest PA X-ray examination from theses and books that had been published previously to understand the importance of proper positioning in chest PA X-ray examination. Generally, one of the examinations frequently done in most of the hospitals is chest PA X-ray examination. Also, in any kinds of X-ray examination, proper positioning is the most fundamental and definite way to provide accurate information about the patient. Poor positioning in chest PA X-ray examination may jeopardize the diagnosis and treatment, increase social cost due to examination needed to be done additionally, and generate additional radiation exposure unnecessarily above all. In conclusion, it is expected that proper positioning in chest PA X-ray examination will exert positive effects such as the provision of accurate information about the patient, prevention of misdiagnosis, reduction in social cost, and lastly decrease in radiation exposure.

A Study on the Resolution Analysis of Digital X-ray Images with increasing Thickness of PMMA (조직 등가물질 두께 증가에 따른 디지털 엑스선 영상의 해상도 분석에 관한 연구)

  • Kim, Junwoo
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.2
    • /
    • pp.173-179
    • /
    • 2021
  • Scattered x-ray generated by digital radiography systems also have the advantage of increasing signals, but ultimately detectability is reduced by decreasing resolution and increasing noise of x-ray images transmitted objects. An indirect method of measuring scattered x-ray in a modulation-transfer function (MTF) for evaluating resolution in a spatial-frequency domain can be considered as a drop in the MTF value corresponding to zero-frequency. In this study, polymethyl methacrylate (PMMA) was used as a patient tissue equivalent, and MTFs were obtained for various thicknesses to quantify the effect of scattered x-ray on resolution. X-ray image signals were observed to decrease by 35 ~ 83% with PMMA thickness increasing, which is determined by the absorption or scattering of x-rays in PMMA, resulting in reduced MTF and increased scatter fraction. The method to compensate for MTF degradation by PMMA resulted in the MTF inflation without considering the optical spreading generated by the indirect-conversion type detector. Data fitting or zero-padding are needed to compensate for MTF more reasonably on edge-spread function or line-spread function.

Double crystal X-ray diffraction characteristics of $Al_xGa_{1-x}As$ grown by LPE (LPE법으로 성장시킨$Al_xGa_{1-x}As$의 이중결정 X-선 회절 특성)

  • 김인수;이철욱;최현태;배인호;김상기
    • Electrical & Electronic Materials
    • /
    • v.6 no.6
    • /
    • pp.565-572
    • /
    • 1993
  • LPE(liquid phase epiraxy)법으로 성장시킨 $Al_{x}$ Ga$_{1-x}$As (0.15.leq.x.leq.0.67) 에피층의 구조적 특성을 이중결정 X-선 회절장치를 사용하여 조사하였다. GaAs기판과 $Al_{x}$ Ga$_{1-x}$As 에피층의 격자상수 차이로 인해 피이크가 분리되었고 이는 조성비가 증가함에 따라 선형적으로 증가하였다. 그리고 조성비는 Vegard의 법칙으로 구한 값과 기판 및 에피층 피이크 사이 각도분리(.DELTA..theta.)를 측정함으로써 구한 값이 일치하였으며 이때 관계식은 .DELTA..theta.=354.x을 얻었다. 또한 성장된 에피층은 compressive stress를 받고 있으며 조성비(x)가 0.15에서 0.67로 증가함에 따라 응력은 증가하였으며 그리고 피이크의 반치폭으로 부터 계산된 전위밀도가 역시 증가하였다.

  • PDF

Synchrotron Radiation Imaging of Breast Tissue Using a Phase-contrast Hard X-ray Microscope (경 엑스선 위상차 현미경을 이용한 유방 조직의 방사광 영상)

  • Jeong, Young-Ju;Bong, Jin-Gu;Park, Sung-Hwan
    • Progress in Medical Physics
    • /
    • v.22 no.3
    • /
    • pp.117-123
    • /
    • 2011
  • Synchrotron radiation (SR) imaging enables us to observe internal structures of biologic samples without staining. In this study, we obtained X-ray microscopic images of human breast tissues with 11.1 KeV hard X-ray microscope of the Pohang light source and used zone plates and phase-contrast technique to get high resolution X-ray images. Hard X-ray microscopic images of fibrocystic change and breast cancer tissues with a spatial resolution of 60 nm were obtained and from these images, we could observe the micro-structures of human breast tissue. Also we analyzed and compared these images, which revealed distinct features of each condition. In conclusion, SR imaging with phase-contrast hard X-ray microscope for medical application, especially in breast disease can give some useful information for clinical research.

A Method for Region-Specific Anomaly Detection on Patch-wise Segmented PA Chest Radiograph (PA 흉부 X-선 영상 패치 분할에 의한 지역 특수성 이상 탐지 방법)

  • Hyun-bin Kim;Jun-Chul Chun
    • Journal of Internet Computing and Services
    • /
    • v.24 no.1
    • /
    • pp.49-59
    • /
    • 2023
  • Recently, attention to the pandemic situation represented by COVID-19 emerged problems caused by unexpected shortage of medical personnel. In this paper, we present a method for diagnosing the presence or absence of lesional sign on PA chest X-ray images as computer vision solution to support diagnosis tasks. Method for visual anomaly detection based on feature modeling can be also applied to X-ray images. With extracting feature vectors from PA chest X-ray images and divide to patch unit, region-specific abnormality can be detected. As preliminary experiment, we created simulation data set containing multiple objects and present results of the comparative experiments in this paper. We present method to improve both efficiency and performance of the process through hard masking of patch features to aligned images. By summing up regional specificity and global anomaly detection results, it shows improved performance by 0.069 AUROC compared to previous studies. By aggregating region-specific and global anomaly detection results, it shows improved performance by 0.069 AUROC compared to our last study.

A Study on the Mask Fabrication Process for X-ray Lithography (X-선 노광용 마스크 제작공정에 관한 연구)

  • 박창모;우상균;이승윤;안진호
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.7 no.2
    • /
    • pp.1-6
    • /
    • 2000
  • X-ray lithography mask with SiC membrane and Ta absorber patterns has been fabricated using ECR plasma CVD, d.c. magnetron sputtering, and ECR plasma etching. The stress of stoichiometric SiC film was adjusted by rapid thermal annealing under $N_2$, ambient. Adjusting the working pressure during sputtering process resulted in a near-zero residual stress, reasonable density, and smooth surface morphology of Ta film. Cl-based plasma showed a good etching characteristics of Ta, and two-step etching process was implemented to suppress microloading effect fur sub-quarter $\mu\textrm{m}$ patterning.

  • PDF

$^{192}$Ir 선원의$\gamma$선 자기흡수효과 측정

  • 조운갑;한현수;박춘득;박울재;이철영
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05b
    • /
    • pp.752-756
    • /
    • 1998
  • 산업용 및 의료용으로 사용되는 $^{192}$ Ir 방사선원에 대한 $\psi$선 자기흡수효과인자를 실험을 통하여 구하였다. 이를 위하여 3 mm $\psi$ x 3 mm t, 2.5 mm $\psi$ x 2.5 mm t, 2 mm $\psi$ x 2 mm Ir의 원주형 Ir 표적과 3 mm $\psi$ x 0.25 mm t, 3 mm $\psi$ x 0.1 mm t의 원판형 Ir 표적을 하나로의 PTS(Pneumatic Transport System)조사공에서 중성자 조사하였다. 이온전리함을 사용하여 각 Ir 표적의 방사능을 측정하고 계산에 의해서 구한 생성방사능 값과의 비를 구하는 방법으로 $^{192}$ Ir의 ${\gamma}$선 자기흡수효과인자를 구하였다. 이 값들은 원주형 표적에 대하여 각각 0.614, 0.687, 0.704 였고 원판형 표적에 대하여 각각 0.827, 0.875 였다. 원주형 Ir 표적내부의 중성자 자기흡수효과의 정도를 알아보기 위하여 2.5 mm $\psi$ x 0.25 mm t Ir 표적 10장을 포개어 중성자 방사화시킨 후 각 표적의 방사능을 측정한 결과 가장 바깥쪽 표적의 방사능이 중심부에 위치한 표적보다 약 2배정도 방사화가 많이 일어남을 알 수 있었다. 이번에 구한 ${\gamma}$선 자기흡수효과인자는 향후 산업용 및 의료용으로 사용되는 $^{192}$ Ir 방사선원의 사용자에게 제공되는 최종방사능을 평가하는데 유용하게 사용될 수 있다.

  • PDF

A Preliminary Study on the Fire Safety Testing Method for Fire-resistance Paints Using an X-ray Analysis Method (X-선 분석법을 이용한 내화도료의 화재안전성 평가 방법에 관한 기초연구)

  • Shim, Ji-Hun;Cho, Nam-Wook;Kim, Kang-Woo
    • Fire Science and Engineering
    • /
    • v.28 no.5
    • /
    • pp.58-63
    • /
    • 2014
  • Fire-resistance paints are supposed to become intumescent and diminish heat transfer along the steel frames in case of a fire. If unsatisfactory fire-resistance paints which do not satisfy their standard specification are used, it may result in a severe disaster. Because satisfactory fire-resistance paints are hardly discriminated from the unsatisfactory ones by a simple visual inspection, more reliable and convenient onsite evaluation methods are necessary. Here we report the preliminary study result on the fire safety testing method for fire-resistance paints using an X-ray analysis method. It was found that the existence and quantity of effective constituents in fire-resistance paints can be detected by the X-ray analysis method. X-ray fluorescence (XRF) analyses showed that P and Cl elements are much more enriched in fire-resistance paints, compared to normal paints. X-ray diffraction (XRD) analyses showed that ammonium polyphosphate is present as the main crystalline material in fire-resistance paints, but absent in normal paints. The X-ray analysis method is expected to be used for the onsite inspection of fire-resistance paints with the upcoming availability of portable XRF and XRD instruments.

The MTF Measurement of the Conventional X-ray System by using the Computed Radiography (CR을 이용한 일반촬영장치의 MTF 측정)

  • Kim, Chang-Bok
    • Journal of radiological science and technology
    • /
    • v.28 no.2
    • /
    • pp.111-115
    • /
    • 2005
  • The quality of image from the system that creates medical images by using X-ray depends on the various different reasons such as the X-ray generator, the subject and the image transmission medium. In other words, thereare various factors existing that can influence on the quality of image from the moment when the X-ray is generated and until the final image is created. Therefore, the operator who creates images at the clinical site should make continuous evaluation and observation from the final image. There are various methods of evaluating the medical images, but it is assumed that the MTF measurement method can be suitable for measuring actual or effective resolution. So in this study, the MTF measurement method by using X-ray film has been avoided and the MTF features according to the deterioration of the X-ray system have been measured by using the software (the program used Borland C++ builder software and LEAD tools software) that can measure the MTF of the digital medical images. As the result of this measurement, it has been found out through the MTF graph that the resolution and sharpness from the old x-ray generator with a many years of using and many numbers of times of using were deteriorated for the quality of image comparing to those from the new system. Also a simple and easy measurement method for the MTF from the digital medical images can be obtained in this study.

  • PDF