• Title/Summary/Keyword: X-선/감마선

Search Result 92, Processing Time 0.026 seconds

Development of Superconducting Transition Edge Sensors for Gamma Ray Detection (감마선 검출을 위한 초전도 상전이 센서)

  • Lee, Young-Hwa;Kim, Yong-Hamb
    • Progress in Superconductivity
    • /
    • v.9 no.2
    • /
    • pp.162-166
    • /
    • 2008
  • We are developing a sensitive gamma ray spectrometer based on superconducting transition edge sensors. The detector consists of a small piece of high purity Sn as an absorber and a Ti/Au bilayer as a temperature sensor. It is designed to measure the thermal signal caused by absorption of gamma rays. The mechanical support and the thermal contact between the absorber and the thermometer were made with Stycast epoxy. The bilayer was formed by e-beam evaporation and patterned by wet etching on top of a $SiN_X$ membrane. A sharp superconducting transition of the film was measured near 100 mK. When the film was biased to the edge of the transition, signals were observed due to single photon absorption emitted from an $^{241}Am$ source. The measured spectrum showed several characteristic peaks of the source including 59.5 keV gamma line. The full with at half maximum was about 900 eV for the 59.5 keV gamma line. The background was low enough to resolve low energy lines. Considerations to improve the energy resolution of the gamma ray spectrometer are also discussed.

  • PDF

Investigation of the Signal Characteristics of a Small Gamma Camera System Using NaI(Tl)-Position Sensitive Photomultiplier Tube (NaI(Tl) 섬광결정과 위치민감형 광전자증배관을 이용한 소형 감마카메라의 신호 특성 고찰)

  • Choi, Yong;Kim, Jong-Ho;Kim, Joon-Young;Im, Ki-Chun;Kim, Sang-Eun;Choe, Yearn-Seong;Lee, Kyung-Han;Joo, Koan-Sik;Kim, Byung-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.1
    • /
    • pp.82-93
    • /
    • 2000
  • Purpose: We characterized the signals obtained from the components of a small gamma camera using Nal(Tl)-position sensitive photomultiplier tube (PSPMT) and optimized the parameters employed in the modules of the system. Materials and Methods: The small gamma camera system consists of a Nal(Tl) crystal ($60{\times}60{\times}6mm^3$) coupled with a Hamamatsu R3941 PSPMT, a resister chain circuit, preamplifiers, nuclear instrument modules (NIMs), an analog to digital converter and a personal computer for control and display. The PSPMT was read out using a resistive charge division circuit which multiplexes the 34 cross wire anode channels into 4 signals (X+, X-, Y+, Y -). Those signals were individually amplified by four preamplifiers and then, shaped and amplified by amplifiers. The signals were discriminated and digitized via triggering signal and used to localize the position of an event by applying the Anger logic. The gamma camera control and image display was performed by a program implemented using a graphic software. Results: The characteristics of signal and the parameters employed in each module of the system were presented. The intrinsic sensitivity of the system was approximately $8{\times}10^3$ counts/sec/${\mu}Ci$. The intrinsic energy resolution of the system was 18% FWHM at 140 keV. The spatial resolution obtained using a line-slit mask and $^{99m}Tc$ point source were, respectively, 2.2 and 2.3 mm FWHM in X and Y directions. Breast phantom containing $2{\sim}7mm$ diameter spheres was successfully imaged with a parallel hole collimator. The image displayed accurate size and activity distribution over the imaging field of view Conclusion: We proposed a simple method for development of a small gamma camera and presented the characteristics of the signals from the system and the optimized parameters used in the modules of the small gamma camera.

  • PDF

Development of an High Speed Detector System for Radiation (방사선원 검출용 고속 탐지기 개발)

  • Lee, Seung-Min;Lee, Hyo-Sung;Lee, Heung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2007.04b
    • /
    • pp.121-123
    • /
    • 2007
  • 광변환 물질을 사용하여 X-선이나 감마방사선을 가시 광으로 변환한 다음 CCD 카메라를 통하여 광량을 측정하면 방사선의 양을 간접적으로 측정할 수 있다. 본 연구에서는 CCD형 비상대응 로봇용 고속 삼차원 방사선 위치 탐지장치에서 방사선 위치 센싱의 핵심 역할을 수행하는 CCD 방사선 탐지부를 간접 방사선 측정 방법을 응용하여 고안하고 구현한 다음 이에 대한 방사선 특성시험 및 거리측정을 수행하였다. 시험 결과로부터 구현한 CCD형 방사선 센서가 방사선 위치 및 선량 탐지장치로 활용 가능성이 충분함 확인하였다.

  • PDF

Evaluation of Characteristics in the Reference Gamma Radiation Fields for testing of Personnel Dosimetry Performance (개인선량 평가의 성능검증을 위한 기준급 감마선장의 특성 평가)

  • Oh, Jang-Jin;Cho, Dae-Hyung;Han, Seung-Jae;Na, Seong-Ho;Lee, Dew-Hey;Lee, Byung-Soo;Jun, Jae-Shik;Chai, Ha-Seok;Yi, Chul-Young
    • Journal of Radiation Protection and Research
    • /
    • v.23 no.4
    • /
    • pp.229-236
    • /
    • 1998
  • In order to establish a testing system for personnel dosimetry performance, the radiation fields from photons, beta particles and neutrons are required, in recent, Korea Institute of Nuclear Safety(KINS) established the reference radation fields except neutrons and tested a variety of their properties. As a result of the test, the reference beams were shown to meet satisfactorily not only the standards of the International Organization for Standardization(ISO), but also the standard levels of the developed countries which are intercomparable with the international traceability. This paper describes the reference beam of gamma radiation. The self-designed and established reference radiation fields were investigated and analyzed by ISO and other international standards. The secondary photon contribution and the beam uniformity of the gamma radiation field were measured and evaluated to fulfill those requirements suggested by the ISO-4037. The measured air kerma rate for the $^{137}$Cs and $^{60}$Co gamma fields was 0.1891 $\sim$ 23.4967 $\mu$Gy/s sand 0.5844 $\sim$ 15.9954 $\mu$Gy/s respectively. The uncertainty with 95 % confidence level of the measured air kerma rate was determined to be less than 2.5 % which is comparable to the international reference gamma radiation fields. It was found that the evaluated air kerma calibration factors of Exradin ionization chamber were in good agreement within 0.9 % and 0.03 % with those given by PTB and NIST, respectively. The gamma radiation fields installed at KINS can maintain traceability systems in Korea, Germany and United State.

  • PDF

A Effect on Physiological Metabolism of Microorganism Which Irradiated by Non-ionization Radiation (비 전리 방사선을 조사한 미생물에서 생리적 대사에 미치는 영향)

  • Ko, In-Ho
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.3
    • /
    • pp.381-387
    • /
    • 2018
  • A Effect on physiological metabolism of microorganism which irradiated by visible light of non-ionization radiation(12,000 Lux) was investigated. The microorganism used in this experiment was a Rhodospirillum rubrum KS-301 of chemosynthetic microorganism. Batch fermentation of glucose were implement, and based on the data resulted from the fermentation. First, physiological characteristic of microorganism which was not irradiated was investigated. As a result, the decrease of the residual quantity of the substance(5.03 g/L - 2.17 g/L) was increased with the quantity of the bacteria(1.08 g/L - 3.14 g/L)and the quantity of the hydrogenous production(0.186 g - 0.3 g) respectively. Second, physiological characteristic of microorganism which was irradiated was investigated. As a result, the decrease of the residual quantity of the substance(13.17 g/L - 5.2 g/L) was increased with the quantity of the bacteria(4.7 g/L - 10.57 g/L)and the quantity of the hydrogenous production(0.186 g - 0.3 g) respectively. As the physiological characteristic of microorganism which was irradiated by visible light of non-ionization radiation(12,000 Lux) was active with its life, but the cell damages irradiated by with gamma-ray, X-ray, electron-ray in ionization radiation were appeared at cell.

Development of a Small Gamma Camera Using NaI(T1)-Position Sensitive Photomultiplier Tube for Breast Imaging (NaI (T1) 섬광결정과 위치민감형 광전자증배관을 이용한 유방암 진단용 소형 감마카메라 개발)

  • Kim, Jong-Ho;Choi, Yong;Kwon, Hong-Seong;Kim, Hee-Joung;Kim, Sang-Eun;Choe, Yearn-Seong;Lee, Kyung-Han;Kim, Moon-Hae;Joo, Koan-Sik;Kim, Byuug-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.4
    • /
    • pp.365-373
    • /
    • 1998
  • Purpose: The conventional gamma camera is not ideal for scintimammography because of its large detector size (${\sim}500mm$ in width) causing high cost and low image quality. We are developing a small gamma camera dedicated for breast imaging. Materials and Methods: The small gamma camera system consists of a NaI (T1) crystal ($60 mm{\times}60 mm{\times}6 mm$) coupled with a Hamamatsu R3941 Position Sensitive Photomultiplier Tube (PSPMT), a resister chain circuit, preamplifiers, nuclear instrument modules, an analog to digital converter and a personal computer for control and display. The PSPMT was read out using a standard resistive charge division which multiplexes the 34 cross wire anode channels into 4 signals ($X^+,\;X^-,\;Y^+,\;Y^-$). Those signals were individually amplified by four preamplifiers and then, shaped and amplified by amplifiers. The signals were discriminated ana digitized via triggering signal and used to localize the position of an event by applying the Anger logic. Results: The intrinsic sensitivity of the system was approximately 8,000 counts/sec/${\mu}Ci$. High quality flood and hole mask images were obtained. Breast phantom containing $2{\sim}7 mm$ diameter spheres was successfully imaged with a parallel hole collimator The image displayed accurate size and activity distribution over the imaging field of view Conclusion: We have succesfully developed a small gamma camera using NaI(T1)-PSPMT and nuclear Instrument modules. The small gamma camera developed in this study might improve the diagnostic accuracy of scintimammography by optimally imaging the breast.

  • PDF

DNA Microarray Analysis of Gene Expression in Antifungal Bacterium of Bacillus lentimorbus WJ5 (DNA microarray를 이용한 항진균 활성세균 Bacillus lentimorbus WJ5의 유전자 발현 분석)

  • 이영근;김재성;장유신;조규성;장화형
    • Korean Journal of Microbiology
    • /
    • v.39 no.3
    • /
    • pp.141-147
    • /
    • 2003
  • The simultaneous expression levels of antifungal activity related genes was analyzed by DNA microarray. We constructed DNA chips contained 2,000 randomly digested genome spots of the antifungal bacterium of Bacillus lentimorbus WJ5 and compared its quantitative aspect with 7 antifungal activity deficient mutants induced by gamma radiation ($^{60}Co$). From the analysis of microarray hybridization by the Gene Cluster (Michael Eisen, Stanford Univ.), totally 408 genes were expressed and 20 genes among them were significantly suppressed in mutants. pbuX (xanthine permease, K222), ywbA (phosphotransferase system enzyme II, K393), ptsG (PTS glucose specific enzyme II ABC component, K877), yufO (ABC transporter (ATP-binding protein), K130l), and ftsY (signal recognition particle (docking protein), K868) were simultaneously down-regulated in all mutants. It suggested that they were supposed to be related to the antifungal activity of B. lentimorbus WJ5.

Application of Viscometric Method for the Detection of Irradiated Black and White Pepper (방사선 조사된 후추가루의 검지를 위한 점도법의 적용)

  • Yi, Sang-Duk;Chang, Kyu-Seob;Yang, Jae-Seung
    • Journal of Food Hygiene and Safety
    • /
    • v.15 no.2
    • /
    • pp.114-121
    • /
    • 2000
  • A study was carried out to establish a detection method for irradiated black and white pepper. Samples were packed in polyethylene bags and irradiated with 2.5, 5, 7.5, 10 and 15 kGy using a Co-60 irradiator. The samples were suspended in water, and alkalized with sodium hydroxide solution. Apparent viscosity was determined after heat gelatinization using a Brookfield DV-III rotation viscometer at 30。C with 30, 60, 90, 120, 150, 180, and 210 rpm. Means and standard deviations of the viscosities of all samples decreased by increasing the stirring speeds. The viscosities increased in all samples by increasing the concentration. Regression expressions and coefficients of viscosity which decreased with increasing irradiation dose of 10% and 13% black pepper, and 7% and 10% white pepper were 0.9531 (y=-131.29x+1,769.0), 0.9725 (y=-351.33x+4,036.0), 0.9731 (y=2,208.0e${^-0.3546X}$), and 0.9959 (y=5,116.0e${^-0.2887X}$), respectively, at 120 rpm. This trend was similar fur all stirring speeds. These results suggest that the detection of irradiated black and white pepper at various doses is possible by the viscometric method.

  • PDF

Comparative Analysis of Treatment Planning System and Dose Distribution of Gamma knife PerfexionTM using EBT-3 Film (EBT-3 필름을 사용한 감마나이프 퍼펙션TM의 치료 계획 시스템 및 선량 분포 비교 분석)

  • Jin, Seongjin;Kim, eongjin;Seo, Weonseop;Hur, Beongik
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.6
    • /
    • pp.509-515
    • /
    • 2017
  • The purpose of this study is to measure the 3 dimensional dose distribution of Gamma knife $Perfection^{TM}$, make a comparative analysis of the result and establish the measurement method for the procedures using EBT3 film. The dose distributions of the Gamma knife $Perfection^{TM}$ installed in two hospitals were evaluated in accuracy and precision. For accuracy, the difference between the mechanical center axis and the dose center axis was assessed on a 4 mm collimator. The allowed difference in accuracy is within 0.3 mm and it was measured as 0.098 mm, 0.195 mm for A hospital and 0.229 mm, and 0.223 mm for B hospital. For precision the difference between the FWHM(Full Width at Half Maximum) of Gamma Plan and measurement in the 4, 8, and 16 mm collimators was calculated. The allowed difference in precision is less than ${\pm}1mm$. The value of the hospital A was -0.283 ~ 0.583 mm, and the hospital B was -0.857 ~ 0.810 mm. When analyzing the dose distributions using the image-j program, it is necessary to establish a clearer reference point of the measurement point, and it is considered that the comparison of the dose distribution should be performed in actual treatment irradiation dose with a high dose usable film.

Effect of Gamma Energy of Positron Emission Radionuclide on X-Ray CT Image (양전자 방출 핵종(18F)의 감마에너지가 X선 CT영상에 미치는 영향)

  • Kim, Gha-Jung;Bae, Seok-Hwan;Kim, Ki-Jin;Oh, Hye-Kyong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.10
    • /
    • pp.4418-4424
    • /
    • 2011
  • This study is aimed to assess the effect of the gamma ray of 511keV energy which is emitted from phantom where the positron emission radionuclide was injected on X-ray CT image. As a scanning method, the CT number and pixel value of the reference image where water was injected(0 mCi), and those acquired by changing the capacity of 18F(Fluorine), positron emission radionuclide, into 1 mCi, 2 mCi, 5 mCi, and 10 mCi were measured. As a result of measuring the CT number(HU) of the phantom image where the positron emission radionuclide($^{18}F$) was injected, there were reference water ($-7.58{\pm}0.66$ HU), 1 mCi($-9.85{\pm}0.50$ HU), 2 mCi($-10.27{\pm}0.21$ HU), 5 mCi($-11.31{\pm}0.66$ HU), and 10 mCi($-13.47{\pm}0.38$ HU). Compared with the image where it was filled with water, there was a reduction of 5.89 Hu in 10 mCi, 3.73 in 5 mCi, 2.69 HU in 2 mCi, and 2 HU in 1 mCi. As for the pixel value of the phantom image, there were reference water ($-2.70{\pm}0.75$), 1 mCi($-4.72{\pm}0.58$), 2 mCi($-6.01{\pm}0.78$), 5 mCi($-6.10{\pm}0.84$), and 10 mCi($-8.20{\pm}0.60$). Compared with the reference image, there was a reduction of 5.50 in 10 mCi, 3.40 in 5 mCi, 3.10 in 2 mCi, and 2.02 in 1 mCi. Through this experiment, it was indicated that, with the increase in the dose of the positron emission radionuclide($^{18}F$), the CT number and the pixel value of the image reduced proportionally, and the width of reduction showed a similar value, too. Accordingly, according to the degree of change in X-ray CT image due to the positron emission radionuclide in the quality control item of PET/CT, the proper standard should be established and it should be periodically managed.