• Title/Summary/Keyword: X rays

Search Result 784, Processing Time 0.025 seconds

Simulation of Energy Resolution of Time of Flight System for Measuring Positron-annihilation induced Auger Electrons (양전자 소멸 Auger 전자 에너지 측정을 위한 Time of Flight의 분해도 향상에 관한 이론적 연구)

  • Kim, J.H.;Yang, T.K.;Lee, C.Y.;Lee, B.C.
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.4
    • /
    • pp.311-316
    • /
    • 2008
  • Since the presence of the chemical impurities and defect at surfaces and interfaces greatly influence the properties of various semiconductor devices, an unambiguous chemical characterization of the metal and semiconductor surfaces become more important in the view of the miniaturization of the devices toward nano scale. Among the various conventional surface characterization tools, Electron-induced Auger Electron Spectroscopy (EAES), X-ray Photoelectron Spectroscopy (XPS) and Secondary Electron Ion Mass Spectroscopy (SIMS) are being used for the identification of the surface chemical impurities. Recently, a novel surface characterizaion technique, Positron-annihilation induced Auger Electron Spectroscopy (PAES) is introduced to provide a unique method for the analysis of the elemental composition of the top-most atomic layer. In PAES, monoenergetic positron of a few eV are implanted to the surface under study and these positrons become thermalized near the surface. A fraction of the thermalized positron trapped at the surface state annihilate with the neighboring core-level electrons, creating core-hole excitations, which initiate the Auger process with the emission of Auger electrons almost simultaneously with the emission of annihilating gamma-rays. The energy of electrons is generally determined by employing ExB energy selector, which shows a poor resolution of $6{\sim}10eV$. In this paper, time-of-flight system is employed to measure the electrons energy with an enhanced energy resolution. The experimental result is compared with simulation results in the case of both linear (with retarding tube) and reflected TOF systems.

Comparative Study of Pneumonia Caused by Streptococcus pneumonia and Legionella pneumophila (레지오넬라 폐렴과 폐렴구균 폐렴 환자의 임상 양상에 대한 비교)

  • Lyu, Ji-Won;Song, Jin-Woo;Choi, Chang-Min;Oh, Yeon-Mok;Lee, Sang-Do;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Mi-Na;Shim, Tae-Sun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.68 no.2
    • /
    • pp.74-79
    • /
    • 2010
  • Background: Legionella pneumophila has been recognized as an important cause of pneumonia. However, limited data are available in the literature regarding legionella pneumonia in Korea. The objective of this study was to compare epidemiological data and clinical presentation of legionella pneumonia and pneumococcal pneumonia. Methods: We retrospectively compared clinical, radiological, and laboratory data, antimicrobial treatment, and treatment outcomes between 28 cases of legionella pneumonia and 56 cases of pneumococcal pneumonia. Diagnoses of both legionella and pneumococcal pneumonia were based on commercial urinary antigen tests. Results: Legionella pneumonia patients included 23 men and 5 women, with a mean age of 61.6 years (range 36~88). Fifteen were smokers and 26 had some underlying diseases. Legionella pneumonia occurred more frequently in healthcare-associated settings than pneumococcal pneumonia (42.9% vs 21.4%, respectively, p=0.040). There were no significant differences in clinical signs and symptoms. Compared to patients with pneumococcal pneumonia, patients with legionella pneumonia presented more frequently with anemia (39.3% vs 8.9%, p=0.001), increased C-reactive protein (57.1% vs 30.4%, p=0.018) and increased alkaline phosphatase (46.4% vs 16.1%, p=0.003). Also, legionella pneumonia patients more often showed pleural effusion on simple chest X-rays (50.0% vs 12.5%, p<0.001). Conclusion: Legionella pneumonia and pneumococcal pneumonia can not be distinguished by clinical manifestations alone. However, legionella pneumonia occurred as a healthcare-associated pneumonia more frequently and was more often associated with anemia and increased CRP and alkaline phosphatase levels.

A Retrospective Analysis of Treatment-Related Prognostic Factors for Local Recurrence after Primary Radiation Therapy for Patients with Primary T1N0 Glottic Cancer (T1N0 성문암의 방사선치료관련 예후 인자 분석)

  • Kim Su-Ssan;Kim Sang-Yoon;Nam Soon-Yuhl;Choi Seung-Ho;Cho Kyung-Ja;Kim Jong-Hoon;Ahn Seung-Do;Shin Seong-Soo;Song Si-Yeol;Choi Eun-Kyung;Lee Sang-Wook
    • Korean Journal of Head & Neck Oncology
    • /
    • v.19 no.1
    • /
    • pp.34-40
    • /
    • 2003
  • Objective: To analyze the treatment-related parameters after the radiotherapy of T1N0 squamous cell carcinoma of the glottic larynx. Materials and Methods: Between October 1989 and August 2000, 54 patients with histologically proven T1N0 squamous cell carcinoma of the glottic larynx who received definitive radiation therapy in Department of Radiation Oncology, Asan Medical Center were analyzed. They were all males with age ranged from 31 to 80 years (median 61 years). 1997 AJCC stages were 31 T1a, 23 T1b. Patients were treated with 4-MV X-rays with a parallel-opposed two-field technique. Ten patients received 66.0-68.4Gy at 1.2Gy per fraction twice daily, 21 patients received 64.8-66.6Gy at 1.8Gy per fraction once daily, and 23 patients received 66.0Gy at 2.0Gy per fraction once daily. Follow-up period was 16-119 months (median 56 months). Results: 5-year overall survival and local control rates for patients with T1 lesions were 87.0% and 88.5%, respectively. 5-year local control with larynx preservation rate was 90.5%. Host and tumor-related prognostic factors including age, stage, anterior commissure involvement and tumor bulk proved not to be significant. Only shorter overall treatment time among treatment-related factors had correlation with imporved local control. Conclusion: Comparable high local control rate with organ preservation was achieved with primary radiation therapy and salvage surgery. Shortening of overall treatment time is related to improved local control rate. To determine the optimal fractionation scheme, randomized trial is mandatory.

A Prospective, Multi-Center, Double-Blind, Randomized Study to Evaluate the Efficacy and Safety of the Synthetic Bone Graft Material DBM Gel with rhBMP-2 versus DBM Gel Used during the TLIF Procedure in Patients with Lumbar Disc Disease

  • Hyun, Seung-Jae;Yoon, Seung Hwan;Kim, Joo Han;Oh, Jae Keun;Lee, Chang-Hyun;Shin, Jun Jae;Kang, Jiin;Ha, Yoon
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.4
    • /
    • pp.562-574
    • /
    • 2021
  • Objective : This study is to evaluate the efficacy and safety of demineralized bone matrix (DBM) gel versus DBM gel with recombinant human bone morphogenetic protein-2 (rhBMP-2) used in transforaminal lumbar interbody fusion (TLIF). Methods : This study was designed as a prospective, multi-center, double-blind method, randomized study. All randomized subjects underwent TLIF with DBM gel with rhBMP-2 group (40 patients) as an experimental group or DBM gel group (36 patients) as a control group. Post-operative observations were performed at 12, 24, and 48 weeks. The spinal fusion rate on computed tomography scans and X-rays films, Visual analog scale pain scores, Oswestry disability index and SF-36 quality of life (QOL) scores were used for the efficacy evaluation. The incidence rate of adverse device effects (ADEs) and serious adverse device effects (SADEs) were used for safety evaluation. Results : The spinal fusion rate at 12 weeks for the DBM gel with rhBMP-2 group was higher with 73.68% compared to 58.82% for the DBM gel group. The 24 and 48 weeks were 72.22% and 82.86% for the DBM gel with rhBMP-2 group and 78.79% and 78.13%, respectively, for the DBM gel group. However, there were no significant differences between two groups in the spinal fusion rate at 12, 24, and 48 weeks post-treatment (p=0.1817, p=0.5272, p=0.6247). There was no significant difference between the two groups in the incidence rate of ADEs (p=0.3836). For ADEs in the experimental group, 'Pyrexia' (5.00%) was the most common ADE, followed by 'Hypesthesia', 'Paresthesia', 'Transient peripheral paralysis', 'Spondylitis' and 'Insomnia' (2.50%, respectively). ADEs reported in control group included 'Pyrexia', 'Chest discomfort', 'Pain', 'Osteoarthritis', 'Nephropathy toxic', 'Neurogenic bladder', 'Liver function analyses' and 'Urticaria' (2.86%, respectively). There was no significant difference between the two groups in the incidence rate of SADEs (p=0.6594). For SADE in the experimental group, ''Pyrexia' and 'Spondylitis' were 2.50%. SADE reported in the control group included 'Chest discomfort', 'Osteoarthritis' and 'Neurogenic bladder'. All SADEs described above were resolved after medical treatment. Conclusion : This study demonstrated that the spinal fusion rates of DBM gel group and DBM gel with rhBMP-2 group were not significantly different. But, this study provides knowledge regarding the earlier postoperative effect of rhBMP-2 containing DBM gel and also supports the idea that the longer term follow-up results are essential to confirm the safety and effectiveness.

Evaluation of Detection Performance of TlBr Materials for the Development of Electron Beam Quality Assurance Dosimeters (전자선 Quality Assurance 선량계 개발을 위한 TlBr 물질의 검출성능 평가)

  • Yang, Seung-Woo;Park, Sung-Kwang
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.5
    • /
    • pp.513-518
    • /
    • 2022
  • Electron beam quality assurance (QA) should be done regularly for accurate radiation therapy. However, QA tools used in clinical practice are designed mainly for X-rays. So, a dosimeter for electron beam QA is required. Therefore, in this study, the electron beam detection performance was measured by using a thorium bromide material as an electron beam sensor. In addition, it was evaluated whether it could be applied with an electron beam QA dosimeter. Reproducibility, linearity, and dose rate dependence were evaluated at 6 MeV and 9 MeV energies. As a result of reproducibility, it showed a maximum output change of 0.92% at 6 MeV and 1.15% at 9 MeV. The linearity result evaluation and determination coefficient were presented as 0.9998. As a result of dose rate dependence evaluation, relative standard deviation 0.51% at 6 MeV and relative standard deviation 1.07% at 9 MeV were presented. The manufactured TlBr sensor shows the ability to detect radiation that meets the criteria for evaluation of reproducibility, linearity, and dose rate dependence. These results mean that the TlBr dosimeter is applicable as an electron beam QA dosimeter.

Impact of lattice versus solid structure of 3D-printed multiroot dental implants using Ti-6Al-4V: a preclinical pilot study

  • Lee, Jungwon;Li, Ling;Song, Hyun-Young;Son, Min-Jung;Lee, Yong-Moo;Koo, Ki-Tae
    • Journal of Periodontal and Implant Science
    • /
    • v.52 no.4
    • /
    • pp.338-350
    • /
    • 2022
  • Purpose: Various studies have investigated 3-dimensional (3D)-printed implants using Ti6Al-4V powder; however, multi-root 3D-printed implants have not been fully investigated. The purpose of this study was to explore the stability of multirooted 3D-printed implants with lattice and solid structures. The secondary outcomes were comparisons between the 2 types of 3D-printed implants in micro-computed tomographic and histological analyses. Methods: Lattice- and solid-type 3D-printed implants for the left and right mandibular third premolars in beagle dogs were fabricated. Four implants in each group were placed immediately following tooth extraction. Implant stability measurement and periapical X-rays were performed every 2 weeks for 12 weeks. Peri-implant bone volume/tissue volume (BV/TV) and bone mineral density (BMD) were measured by micro-computed tomography. Bone-to-implant contact (BIC) and bone area fraction occupancy (BAFO) were measured in histomorphometric analyses. Results: All 4 lattice-type 3D-printed implants survived. Three solid-type 3D-printed implants were removed before the planned sacrifice date due to implant mobility. A slight, gradual increase in implant stability values from implant surgery to 4 weeks after surgery was observed in the lattice-type 3D-printed implants. The marginal bone change of the surviving solid-type 3D-printed implant was approximately 5 mm, whereas the value was approximately 2 mm in the lattice-type 3D-printed implants. BV/TV and BMD in the lattice type 3D-printed implants were similar to those in the surviving solid-type implant. However, BIC and BAFO were lower in the surviving solid-type 3D-printed implant than in the lattice-type 3D-printed implants. Conclusions: Within the limits of this preclinical study, 3D-printed implants of double-rooted teeth showed high primary stability. However, 3D-printed implants with interlocking structures such as lattices might provide high secondary stability and successful osseointegration.

Congenital Insensitivity to Pain with Anhidrosis: Five-Year-Old Girl with a Neglected Distal Femur Fracture (선천성 무통증과 무한증: 5세 여아에서 발생한 방치된 원위 대퇴골 골절)

  • Woo, Seung Hun;Kim, Tae Woo;Bae, Jung Yun;Kwak, Sang Ho
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.5
    • /
    • pp.463-468
    • /
    • 2019
  • Congenital insensitivity to pain with anhidrosis (CIPA) is a rare disease that affects the sensory and autonomic nervous system. The patients do not have the ability to sense different sensations, such as pain, which tends to lead to different injuries. In addition, the patients suffer from fluctuations in body temperature due to autonomic involvement. The present case was a five-year-old girl with a neglected distal femur fracture. X-rays taken during the follow-up showed marked callus formation and pseudarthrosis of the distal femur. She had biting injuries of the tongue, auto-amputation of the fingers, some developmental delay and a history of recurrent fever with an unknown origin. The electrodiagnostic study was normal. The quantitative sudomotor axon reflex test revealed markedly reduced postganglionic sudomotor axonal responses at all sites recorded on the left. She was diagnosed with CIPA. As the initial presentation of CIPA involves the musculoskeletal system, orthopedic surgeons should have a high index of suspicion.

Correlation between Lumbar Malposition and Disc Herniation in Lumbar Disc Herniation Patients: Focused on L4-L5, L5-S1 (요추 추간판 탈출 환자에서 나타나는 요추부 변위와 추간판 탈출의 상관관계: L4-L5, L5-S1 요추 간 추간판 탈출을 중심으로)

  • Yeon-Hoo Yi;Da-woon Song;Jae-Min Jeong;Tae-ha Kwon;Sae-young Bong;Yoo-jin Lee;Jin-Bong Choi
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.33 no.4
    • /
    • pp.185-193
    • /
    • 2023
  • Objectives This study was conducted to find out the correlation between lumbar malposition and lumbar disc herniation. Methods Among the patients who visited Gwangju Jaseng Hospital of Korean Medicine from January 2019 to January 2021, taking 92 patients under age 60 who had the records of X-rays and magnetic resonance imaging (MRI) images as the research subjects, Cobb's angle was measured in anterior-posterior (AP) view and lateral (LAT) view, the number of displacements was scored by listing categories defined by The Korean Society of Chuna Manual Medicine for Spine and Nerves. The degree of lumbar intervertebral disc herniation was expressed as a percentage according to the method of Kato, etc., and the correlation between each factor was analyzed. Results AP curvature and MRI herniation index showed significant positive correlation in L4-L5 level but there was no significant difference in L5-S1 level. LAT curvature and MRI herniation index had no correlation in L4-L5 level, but there was a significant negative correlation in L5-S1 level. Malposition score and MRI herniation index had a significant positive correlation in L5-S1 level, whereas there was no correlation in L4-L5. Conclusions As a result of the study, AP curvature and MRI herniation index showed a significant positive tendency in L4-L5 lumbar spine, and LAT curvature and MRI herniation index showed a significant negative tendency in L5-S1 lumbar spine. Malposition score and MRI herniation index were found to have a significant positive tendency in L5-S1 lumbar spine.

Chemical Age Dating of Zircon and Monazite by E1ectron Microprobe (전자현미분석기를 이용한 저어콘 및 모나자이트의 화학적 연대 측정법)

  • 이석훈
    • The Journal of the Petrological Society of Korea
    • /
    • v.10 no.3
    • /
    • pp.179-189
    • /
    • 2001
  • The determination of trace concentration of U, Th and Pb was carried out for chemical dating of zircon and monazite by electron microprobe. Detection limit and error range should be considered to measure characteristic X-rays of M-line from those minerals, which are low in the ionization of atom and low peak intensity in the spectrum. The element of U, Th and Pb were simultaneously measured with 3 spectrometers equipped with PET crystal to reduce a total counting time and error due to drift of instrumental operating condition. Detection limit could be improved from increase of the peak/background ratio through adjusting pulse height analyzer about 1000 mv baseline. Under permissible maximum analytical conditions, theoretical detection limit of U, Th and Pb is down to 30 ppm (99% confidence level). The analytical result was maintained at a relative error $\pm$10% ($2{\sigma}$) in 800 ppm Pb, $\pm$5% ($2{\sigma}$) in 2330 ppm U and $\pm$10% ($2{\sigma}$) in dating from a single measurement of zircon at 15 keV and 100 nA. However, for the precise dating of zircon and monazite, if it is considered a 3 $\mu\textrm{m}$ spatial resolution, <100 ppm ($3{\sigma}$) detection limit and <$\pm$10% ($2{\sigma}$) relative error, optimum analytical conditions are given as 15~20 keV accelerating voltage, 100~200 nA beam current and 300~1200 sec total counting time. To reduce material damage by high current, there is need to be up to 3~5 $\mu\textrm{m}$ of electron beam diameter, or to use arithmetic average of multiple measuring at a shorter counting time. A younger or relatively low concentration rocks can be dated chemically by lower detection limit and improved precision resulted from increase of current and measuring time.

  • PDF

Usefulness of Interferon-$\gamma$ Measurement Following Stimulation of Tuberculosis-specific Antigens for Diagnosis of Latent Tuberculosis Infection in Children Exposed to Pulmonary Tuberculosis (폐결핵 접촉력을 가진 소아에서 잠복 결핵 감염의 진단을 위한 결핵 특이항원 자극 인터페론-감마 측정의 유용성)

  • Sung, Ji Yeon;Ki, Joo Hwa;Yang, Mi Ae;Kim, So Hee;Eun, Byung Wook;Kim, Nam Hee;Park, Kyoung Un;Lee, Jina;Choi, Eun Hwa;Lee, Hoan Jong
    • Pediatric Infection and Vaccine
    • /
    • v.15 no.1
    • /
    • pp.52-58
    • /
    • 2008
  • Purpose : Whole blood interferon-$\gamma$ assay was developed and many studies showed its usefulness in diagnosing tuberculosis (TB) including latent tuberculosis infection (LTBI). However, assessment in children has been limited. This study was undertaken to evaluate the usefulness of QuantiFERON-TB Gold for the diagnosis of LTBI in children exposed to pulmonary TB. Methods : Children who visited Seoul National University Bundang Hospital with a history of TB exposure were enrolled from January 2006 to December 2007. They were evaluated with chest x-rays, tuberculin skin test (TST) and QuantiFERON-TB Gold test. TST was retested 3 months later for those with initial negative reactivity. Definition of LTBI was made on the basis of the TST reactivity. Results : Among the 103 children with a history of TB exposure, 49 children were tested with chest x-ray, TST, and QuantiFERON-TB Gold. Twenty-two were males. Median age was 7.5 years (range; 3 months to 14.7 years). According to TST reactivity, LTBI was in 8 (19%), no infection was in 21 (50%), possible LTBI was in 13 (31%). QuantiFERON-TB Gold test was positive in 5 of the 49 subjects (10%); 3 of the 13 subjects (23.1%) in unknown status, 1 of the 8 subjects (13%) in LTBI, and 1 of the 21 subjects (5%) without infection. The agreement between the QuantiFERON-TB Gold and the TST was poor (${\kappa}=0.101$). Conclusion : QuantiFERON-TB Gold showed poor sensitivity for the diagnosis of LTBI in children with exposure to TB. QuantiFERON-TB Gold alone does not seem to be useful in the diagnosis of LTBI in children.

  • PDF