• Title/Summary/Keyword: X선 일반검사

Search Result 36, Processing Time 0.021 seconds

Analyze for the Quality Control of General X-ray Systems in Capital region (수도권지역 일반촬영 장비의 정도관리 분석)

  • Kang, Byung-Sam;Lee, Kang-Min;Shim, Woo-Yong;Park, Soon-Chul;Choi, Hak-Dong;Cho, Yong-Kwon
    • Journal of radiological science and technology
    • /
    • v.35 no.2
    • /
    • pp.93-102
    • /
    • 2012
  • Thanks to the rapid increase of the interest in the quality control of the General X-ray systems, this research proposes the direction of the quality control through comparing and inspecting the actual condition of the respective quality control in the Clinic, the educational institution and the hospital. The subjects of the investigation are diagnostic radiation equipment's in the clinic, the educational institution and the hospital around the capital. A test of kVp, mR/mAs out put test and reproducibility of the exposure dose, half value layer, an accordance between the light field and the beam alignment test, and lastly reproducibility of the exposure time. Then the mean difference of the percentage, the CV (Coefficient of Variation, CV) and the attenuated curve which are respectively resulted from the above tests are computed. After that we have evaluated the values according to the regulations on the Diagnostic Radiation Equipment Safety Administration regulations. In the case of the clinic and the educational institution, there were 22 general X-ray devices. And 18.2% of the kVp test, 13.6% of the reproducibility of exposure dose test, 9.1% of the mR/mAs out put test, and 13.6% of the HVL (Half Value Layer) test appeared to be improper. In the case of the hospital, however, there were 28 devices. And 7.1% of the reproducibility of exposure dose, 7.1% of the difference in the light field/ beam alignment, and 7.1% of the reproducibility of the exposure time appeared to be improper. According to the investigation, the hospital's quality control condition is better than the condition in the clinic and the educational institution. The quality control condition of the general X-ray devices in the clinic is unsatisfactory compared to the hospital. Thus, it is considered that realizing the importance of the quality control is necessary.

Absorbed Spectrum Comparison of Lead and Tungsten in Continuous X-ray Energy using Monte Carlo Simulation (몬테카를로 시뮬레이션을 통한 연속 엑스선 에너지에서 납(Pb)과 텅스텐(W)의 흡수 스펙트럼 비교 연구)

  • Kim, Kyotae;Kang, Sangsik;Noh, Sicheul;Jung, Bongjae;Cho, Changhoon;Heo, Yeji;Park, Jikoon
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.6
    • /
    • pp.483-487
    • /
    • 2012
  • In 1895, the discovered X-ray is used for not only in this field of medicine wide but also field. The detection of radiation after, people realized the risk of the radiation exposured recommended the principle about the protection of radiation by the part of the effort for lowering the radiation exposure. In this recommendation, all unnecessary radiation exposure have to be prevented by All doses include the protection of radiation, general idea of applicable two kinds of that it has to low maintain. Presently, in the General X-ray room of the clinical, the lead (Pb) was used for the shielding, However, because it had the problem of the lead poisoning which is fatal in the human body, the alternatives was showed. and Among them, the material that it is the tungsten was presented. in this research, the absorbed spectrum according to the thickness in the continuous X-ray energy of the tungsten which is not harmful to the human body through the Monte Carlo simulation, tried to compare with the absorbed spectrum of the lead (Pb). The tungsten confirmed that simulation presumption than result lead in the whole domain that absorbed probability was higher and it is considered that tungsten shows the absorbed efficiency higher than the lead in particularly, 70 keV ~ 90 keV and the tungsten is more useful to the X-ray energy cover of the high energy diagnostic area.

Research on the Actual Condition of Mammograpgy and Space Scattered Dose in Mammography Room (유방촬영의 실태와 유방촬영실의 공간산란선량에 관한 조사 연구)

  • Lee, In-Ja;Park, Kye-Yeon;Kim, Sung-Soo
    • Journal of radiological science and technology
    • /
    • v.29 no.1
    • /
    • pp.21-28
    • /
    • 2006
  • I made inquires about mammographic equipments and circumstances of mammography rooms in the 64 medical facilities in areas of Seoul and Kyong Gi Do. Moreover I had experments about exposure dose with patients and radiologic technologists. so there is the data indicated follows. 1. There are inclined to improve in quality and function of mammographic equipments, it has been proven that s/f system exchanged to DR system. 2. It is certain that the number of examinations are becoming increasingly significant. 3. The Space Scattered Dose of mammography rooms are much more larger than portable equipments. 4. I worry about the affection of expose dose about Space Scattered Dose of mammography room. 5. There is need of study how to cope with the situation about increasing exposure dose of radiologic technologists in small space and numeruous number of examinations.

  • PDF

Two Dimensional Size Effect on the Compressive Strength of Composite Plates Considering Influence of an Anti-buckling Device (좌굴방지장치 영향을 고려한 복합재 적층판의 압축강도에 대한 이차원 크기 효과)

  • ;;C. Soutis
    • Composites Research
    • /
    • v.15 no.4
    • /
    • pp.23-31
    • /
    • 2002
  • The two dimensional size effect of specimen gauge section ($length{\;}{\times}{\;}width$) was investigated on the compressive behavior of a T300/924 $\textrm{[}45/-45/0/90\textrm{]}_{3s}$, carbon fiber-epoxy laminate. A modified ICSTM compression test fixture was used together with an anti-buckling device to test 3mm thick specimens with a $30mm{\;}{\times}{\;}30mm,{\;}50mm{\;}{\times}{\;}50mm,{\;}70mm{\;}{\times}{\;}70mm{\;}and{\;}90mm{\;}{\times}{\;}90mm$ gauge length by width section. In all cases failure was sudden and occurred mainly within the gauge length. Post failure examination suggests that $0^{\circ}$ fiber microbuckling is the critical damage mechanism that causes final failure. This is the matrix dominated failure mode and its triggering depends very much on initial fiber waviness. It is suggested that manufacturing process and quality may play a significant role in determining the compressive strength. When the anti-buckling device was used on specimens, it was showed that the compressive strength with the device was slightly greater than that without the device due to surface friction between the specimen and the device by pretoque in bolts of the device. In the analysis result on influence of the anti-buckling device using the finite element method, it was found that the compressive strength with the anti-buckling device by loaded bolts was about 7% higher than actual compressive strength. Additionally, compressive tests on specimen with an open hole were performed. The local stress concentration arising from the hole dominates the strength of the laminate rather than the stresses in the bulk of the material. It is observed that the remote failure stress decreases with increasing hole size and specimen width but is generally well above the value one might predict from the elastic stress concentration factor. This suggests that the material is not ideally brittle and some stress relief occurs around the hole. X-ray radiography reveals that damage in the form of fiber microbuckling and delamination initiates at the edge of the hole at approximately 80% of the failure load and extends stably under increasing load before becoming unstable at a critical length of 2-3mm (depends on specimen geometry). This damage growth and failure are analysed by a linear cohesive zone model. Using the independently measured laminate parameters of unnotched compressive strength and in-plane fracture toughness the model predicts successfully the notched strength as a function of hole size and width.

Evaluation of Image Quality & Absorbed Dose using MCNPX Simulation in the Digital Radiography System (디지털방사선영상시스템에서 MCNPX 시뮬레이션을 이용한 영상 품질 및 선량평가)

  • An, Hyeon;Lee, Dongyeon;Ko, Sungjin;Kim, Changsoo
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.5
    • /
    • pp.327-335
    • /
    • 2016
  • The study is enforce to study image quality evaluation of condition provide the IEC and combination of clinical conditions each quality of radiation that image quality to assess the conditions provided to IEC in the clinical environment to conduct image quality assessment of the digital radiography system in the detector have environmental limits. First, image quality evaluation was evaluated by measuring the MTF, NPS using four quality of radiation and Using MCNPX simulation lastly DQE make a image quality evaluation after calculating the particle fluence to analyze spectrum quality of radiation. Second, Using MCNPX simulation of four quality of radiation was evaluated absorbed dose rate about electronic 1 per unit air, water, muscle, bone by using Radiation flux density and energy, mass-energy absorption coefficient of matter. Results of evaluation of image quality, MTF of four quality of radiation was satisfied diagnosis frequency domain 1.0 ~ 3.0 lp/mm of general X-ray that indicated 1.13 ~ 2.91 lp/mm spatial frequency. The NPS has added filter, spatial frequency 0.5 lp/mm at standard NPS showed a tendency to decrease after increase. Unused added filter, spatial frequency 0.5 lp/mm at standard NPS showed a certain NPS result value after decrease. DQE in 70 kVp / unuesd added filter(21 mm Al) / SID 150 cm that patial frequency 1.5 lp/mm at standard showed a tendency to decrease after certain value showed. Patial frequency in the rest quality of radiation was showed a tendency to decrease after increase. Results of evaluation of absorbed dose, air < water < muscle < bone in the order showed a tendency to increase. Based on the results of this study provide to basic data that present for the image quality evaluation method of a digital radiation imaging system in various the clinical condition.

Clinical Characteristics of Asthmatic Patients Who Visited Emergency Room (응급실로 내원한 천식환자들의 임상적 특성)

  • Suh, Jung-Kyung;Lee, So-Ra;Lee, Sang-Youb;Lee, Sang-Hwa;Cho, Jae-Youn;Shim, Jae-Jeong;In, Kwang-Ho;Kang, Kyung-Ho;Yoo, Se-Hwa
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.2
    • /
    • pp.290-297
    • /
    • 1997
  • Background : Despite remarkable progress of understanding the pathophysiology and therapy of bronchial asthma, asthma morbidity and mortality are on the rise. Also hospitalization and attending rates of emergency department for asthma have been increasing gradually. We analyzed clinical characteristics and prognosis of patients who visited emergency room due to asthma attack in order to define clinical characteristics of these group of patients. Method : We reviewed 105 adult asthmatic patients who attended emergency department of Korea University Hospital between August 1995 and July 1996, retrospectively. Results : 103 patients(56 female, 47 males, mean age : 48.6 years) attended-68 self referral, 18 practitioner referral and 17 OPD transfer- and 86 patients(83.5%) were admitted. Attending emergncy department was clearly more frequent in December(13.6%) and May(12.6%). Time lag between onset of asthmatic attack and arrival at the hospital was $14.2{\pm}15.5$ hour and initial peak expiratory flow rate was $166.7{\pm}68.3L/min$.(43.3% predicted) The commonest cause for visiting emergency room was aggravation of asthma due to upper respiratory tract infection in mild asthmatics. About half of them had history of previous ER visits. Their prognosis was not bad, but after discharge, about half of patients escaped from OPD follow-up. Conclusion : As a group they merit detailed attention and follow up arrangement. Clinician need to monitor and review the treatment plans, the medications, the patient's management technique, and the level of asthma control. For this group, plans for longer term treatment, including asthma education program and adjustment of overall treatment plan should be made.

  • PDF