• Title/Summary/Keyword: X선

Search Result 1,674, Processing Time 0.033 seconds

The Intensity Scale of Multiple Scattering of X-rays in Non-Crystalline Solids (비정질 고체에 대한 X선의 다중 산란 강도)

  • 박성수;장윤식;류봉기;박희찬
    • Journal of the Korean Ceramic Society
    • /
    • v.34 no.1
    • /
    • pp.109-113
    • /
    • 1997
  • When the intensity of X-rays scattered from amorphous materials (very weakly absorbing materials) is measured using standard diffractometric technique, the intensity caused by multiple scattering is obtained in the measured X-ray intensity. Computer programs have been developed to estimate the intensity of the mul-tiple scattering obtained in vitreous SiO2 and B2O3 with various X-rays. Using the above computer program, the intensity ratios of multiple scattering to single scattering in vitreous SiO2 were 0.10~0.16% at CuK$\alpha$, 0.98~5.87% at MoK$\alpha$, and 1.88~17.86% at AgK$\alpha$ in the range of 2$\theta$=0~180$^{\circ}$. Therefore, pri-or to the structural analysis of vitreous SiO2 and B2O3 performed experimentally using X-ray diffractometric technique, the intensity data measured in MoK$\alpha$ and AgK$\alpha$ radiations must be corrected for multiple scattering effect.

  • PDF

Assessment of Effective Dose from Diagnostic X-ray Examinations of Adult (진단X선에 의한 성인의 진단행위별 유효선량평가)

  • Kim, Woo-Ran;Lee, Choon-Sik;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.27 no.3
    • /
    • pp.155-164
    • /
    • 2002
  • Methodology to evaluate the effective doses to adults undergoing various diagnostic x-ray examinations were established by Monte Carlo simulation of the x-ray examinations. Anthropomorphic mathematical phantoms, the MIRD5 male phantom and the ORNL female phantom, were used as the target body and x-ray spectra were produced by the x-ray spectrum generation code SPEC78. The computational procedure was validated by comparing the resulting doses to the results of NRPB studies for the same diagnostic procedures. The effective doses as well as the organ doses due to chest, abdomen, head and spine examinations were calculated for x-rays incident from AP, PA, LLAT and RLAT directions. For instance, the effective doses from the most common procedures, chest PA and abdomen AP, were 0.029 mSv and 0.44 mSv, respectively. The fact that the effective dose from PA chest x-ray is far lower than the traditional value of 0.3 mSv(or 30 mrem), which results partly from the advances of technology in diagnostic radiology and partly from the differences in the dose concept employed, emphasizes necessities of intensive assessment of the patient doses in wide ranges of medical exposures. The methodology and tools established in this study can easily be applied to dose assessments for other radiology procedures; dose from CT examinations, dose to the fetus due to examinations of pregnant women, dose from pediatric radiology.

A Study on the Fabrication of bone Model X-ray Phantom Using CT Data and 3D Printing Technology (CT 데이터와 3D 프린팅 기술을 이용한 뼈 모형 X선 팬텀 제작에 관한 연구)

  • Yun, Myeong Seong;Han, Dong-Kyoon;Kim, Yeon-Min;Yoon, Joon
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.7
    • /
    • pp.879-886
    • /
    • 2018
  • A 3-dimensional (D) printer is a device capable of outputting a three-dimensional solid object based on data modeled in a computer. These features are utilized in the bone model X - ray phantom production etc using CT data by fusing with the radiation science field. A bone model phantom was made using data obtained by CT scan of an existing Pelvis phantom, using PLA, Wood, XT-CF20, Glow fill, Steel filaments which are materials of Fused Filament Fabrication (FFF) 3D printer.Measure Hounsfield Unit (HU) with images obtained by CT scan of the existing Pelvis phantom and five material phantoms made with 3D printer under the same conditions,SI and SNR were measured using a diagnostic X-ray generator, and each phantom was compared and analyzed.As a result, the X - ray phantom in the X - ray examination condition of the limb was found to be most suitable for the glow fill filament.The characteristics of the filament can be known to the base of this research and the practicality of X - ray phantom fabrication was confirmed.

Diagnosis of Scoliosis Using Chest Radiographs with a Semi-Supervised Generative Adversarial Network (준지도학습 방법을 이용한 흉부 X선 사진에서 척추측만증의 진단)

  • Woojin Lee;Keewon Shin;Junsoo Lee;Seung-Jin Yoo;Min A Yoon;Yo Won Choi;Gil-Sun Hong;Namkug Kim;Sanghyun Paik
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.6
    • /
    • pp.1298-1311
    • /
    • 2022
  • Purpose To develop and validate a deep learning-based screening tool for the early diagnosis of scoliosis using chest radiographs with a semi-supervised generative adversarial network (GAN). Materials and Methods Using a semi-supervised learning framework with a GAN, a screening tool for diagnosing scoliosis was developed and validated through the chest PA radiographs of patients at two different tertiary hospitals. Our proposed method used training GAN with mild to severe scoliosis only in a semi-supervised manner, as an upstream task to learn scoliosis representations and a downstream task to perform simple classification for differentiating between normal and scoliosis states sensitively. Results The area under the receiver operating characteristic curve, negative predictive value (NPV), positive predictive value, sensitivity, and specificity were 0.856, 0.950, 0.579, 0.985, and 0.285, respectively. Conclusion Our deep learning-based artificial intelligence software in a semi-supervised manner achieved excellent performance in diagnosing scoliosis using the chest PA radiographs of young individuals; thus, it could be used as a screening tool with high NPV and sensitivity and reduce the burden on radiologists for diagnosing scoliosis through health screening chest radiographs.

MBE Growth and X-ray Analysis of (InAs)n(AlAs)n Short Period Superlattice ((InAs)n(AlAs)n 단주기 초격자의 MBE 성장과 X선화질)

  • 우덕하;우종천
    • Journal of the Korean Vacuum Society
    • /
    • v.1 no.3
    • /
    • pp.395-399
    • /
    • 1992
  • In0.5Al0.5As와 같은 조성을 갖는 합금인 n=1~4인 (InAs)n(AlAs)n 형태의 완벽한 층 상구조의 단주기 초격자를 MBE 방법으로 성장하였다. 저온 PL 측정을 통하여 광학적 특성 을 조사하였으며, Raman 산란실험을 통하여 구조적 특성을 조사하였다. X선화질 실험을 통하여 홀수 번호의 회적을 관측할 수 있었는데 이것은 초격자에 의한 새로운 주기의 형성 을 직접적으로 보여 주는 것이다.

  • PDF

Evaluation of Multi-resolution Extraction Filter for Pulmonary Nodules in Chest X-ray Image (흉부 X선 영상내 다중해상도 폐 종류 검출필터의 평가)

  • Kim, Eung-Kyeu
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1983-1984
    • /
    • 2011
  • 본 논문에서는 흉부 X선 영상으로부터 폐 종류 음영을 검출하기 위한 필터를 예측해서 바람직하게 평가하기 위한 방법을 제안한다. 더욱이 그 평가방법을 이용해서 이전부터 제안한 다중해상도 라플라시안-가우시안 필터의 평가를 행한다. 전문의의 진단보조 혹은 종합자동진단시스템의 구성요소로서 필터가 행하는 역할을 고려한 후에 필터가 만족해야할 조건 및 그 조건을 만족한 경우에 있어서 몇가지 성능평가 척도를 명확히 한다. 제안한 평가방법을 통해서 다중해상도 필터가 단일해상도 필터에 비해 높은 성능을 갖게됨을 명확히 한다.

  • PDF

Grid Angle Optimization for Grid Artifact Reduction in Digital Radiography (디지털 방사선 영상의 그리드 왜곡 제거를 위한 회전 각도의 최적화)

  • Kim, Dong-Sik
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2010.07a
    • /
    • pp.438-439
    • /
    • 2010
  • 산란선을 흡수하여 보다 선명한 x선 영상을 얻기 위하여 산란방지 그리드를 사용하여 투사영상을 얻는데, 이때 그리드로 인한 왜곡이 발생한다. 본 논문에서는 회전된 그리드를 사용하여 투사영상을 얻어서 그리드 왜곡을 제거하는 방법에서, 보다 효율적인 그리드 왜곡 제거를 위한 최적의 그리드 각도를 얻기 위한 min-max 최적화 방법을 제시하였고, 몇 가지 예를 통하여 최적의 그리드 각도를 구하였으며, 실제 x선 영상에 적용하여 그 성능을 비교해 보았다.

  • PDF

X선 감지를 위한 PIN형 실리콘 다이오드 어레이 제작

  • Cha, Gyeong-Hwan;Lee, Gyu-Hang;Nam, Hyeong-Jin
    • Proceedings of the Korean Society Of Semiconductor Equipment Technology
    • /
    • 2007.06a
    • /
    • pp.86-89
    • /
    • 2007
  • 실리콘을 사용한 X선 감지 용 센서 어레이 제작에 대해 연구하였다. 단일 센서 소자에서는 필수적인 guard ring구조가 어레이에서는 적절히 설계되지 못할 경우 누설전류 증가를 초래하는 것으로 나타났다. 즉, 누설전류는 공??????층 두께와 능동영역 및 guard ring 구조 간 거리에 매우 민감한 것으로 조사되었다. 또한 다결정 실리콘과 n형 도핑 소스로 인을 활용하는 조합이 결함 gettering을 위한 효율적인 방법임이 입증되었으나 고온 공정과정에 보호되지 않은 채 노출되는 경우에는 효과적이지 못한 것으로 관측되었다. 본 연구에서는 이러한 결과들을 고려하여 어레이를 제작하였으며 우수한 특성을 관찰할 수 있었다.

  • PDF

1984~1985년의 미국100대 발명, 발견

  • Korean Federation of Science and Technology Societies
    • The Science & Technology
    • /
    • v.19 no.1 s.200
    • /
    • pp.48-57
    • /
    • 1986
  • - DATA파이프 - 화학품 생산을 위한 바이오매스의 이용 - 선형 프로그래밍 산법 - 복합질병을 위한 왁찐 - 말라리아 왁찐 - 데이터 기록용의 확장식 디스크매체 - 생세포의 냉동보존용 전산화 시각분석법 - 콜버그완 - 중유회수의 능률향상 - 충돌 들뜸체계이용 소프트 X선 레이저 - 스터얼링 사이클 저온 냉각기 - 셀데인 - 플라즈마 체계이용 소프트 X선 레이저 - 수력터빈 시스템 - 암호시스템을 해독하는 산법 - 균일한 크기의 극히 미세한 물질을 형성하는 공정 - 마그네켄치 - 리그닌 퇴화효소 - 코즈믹 튜브 - 테라비트 Km/Sec용량의 광전송 - 폴리머-세라믹 복합체 - 노바 - 살아있는 뇌의 신경 수용체를 보고 측정하는 방법

  • PDF

A effect on the high field conduction and carrier traps in polythylene (폴리에틸렌의 고전계 전기전도 및 캐리어 트랩에 미치는 공중합의 효과)

  • 유근민;이종호;이규철
    • Electrical & Electronic Materials
    • /
    • v.6 no.1
    • /
    • pp.50-54
    • /
    • 1993
  • 각종 monomer를 공중합시킨 PE의 고전계 전기전도와 X선 유기 TSC(X-ray induced thermally stimulated current)를 측정하고 공중합 monomer의 영향에 대하여 검토하였다. 할로겐을 함유한 공중합 PE에서 고전계 전기전도가 억제되는 것을 관찰하였다. 또 할로겐을 함유하는 monomer를 공중합시킨 PE의 X선 유기 TSC에서는 공중합에 의한 전자 trap은 약 0.4eV정도로 평가된다. 이들 시료에서 절연 파괴 강도가 상승한 것은 전자 트랩이 전자의 전계가속을 억제하여 고전계 전기전도를 억제시키고 절연파괴강도를 향상 시킨 것으로 추측된다.

  • PDF