• Title/Summary/Keyword: X선조사야

Search Result 478, Processing Time 0.031 seconds

A Case Study on Geotechnical Properties and Weathering Degree of Weathered Granite Rock (화강 풍화암의 지반특성 및 풍화도 평가에 대한 사례 연구)

  • Lee, Seung-Hwan;Yoo, Byeong Soo;Chung, Choong-Ki
    • Journal of the Korean Geotechnical Society
    • /
    • v.33 no.12
    • /
    • pp.127-139
    • /
    • 2017
  • Site investigation including boring and various in-situ borehole test (Pressuremeter test, Borehole shear test, Downhole test, Suspension PS logging, Density logging) and X-ray fluorescence analysis for rock core sample were performed to estimate geotechnical properties and weathering degree of weathered granite rock in Goyang. Deformation modulus, shear strength parameter and shear wave velocity estimated through in-situ borehole test had a tendency to increase with depth. And several chemical weathering indices evaluated by X-ray fluorescence analysis had a general tendency of reducing weathering degree in accordance with depth. Also, relationship between VR determined as a representative weathering index and the geotechnical properties was analyzed.

The Correlations between Mineralogy and Engineering Characteristics of Soft Clay in Sihwa Area (시화지구 연약점토의 광물학적 특성과 공학적 특성의 상관관계)

  • Kim Nak-Kyung;Park Jong-Sik;Joo Yong-Sun
    • Journal of the Korean Geotechnical Society
    • /
    • v.20 no.9
    • /
    • pp.155-166
    • /
    • 2004
  • The characteristics of soft clays are very important for the land development plan. This study is to investigate correlations between the engineering properties and the characteristics of clay minerals of the undisturbed clay samples obtained from Sihwa area. This study included X-Ray diffraction analysis, X-Ray fluorescence spectrometer analysis, scanning electron microscopy analysis and energy dispersive X-Ray spectrometer analysis. The correlations between the clay mineral properties and the laboratory and field testing results were investigated. The characteristics of soft clay in Sihwa area were compared with those in Yangsan and Kunsan area.

Investigation of Geometrical Properties on Deposition Rate in Cesium Iodine Film (증착속도에 따른 CSI layer의 기하학적 특성 연구)

  • Lee, Kyu-Hong;Park, Ji-Koon;Kang, Sang-Sik;Cha, Byung-Yul;Cho, Sung-Ho;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.415-417
    • /
    • 2003
  • CsI 형광체는 X선에 대한 분해능 및 변환효율이 우수한 물질이다. 최근 대면적 평판형 X선 영상검출기의 변환층으로 이용하기 위해 CsI 형광체의 대면적 제조에 대한 연구가 활발히 진행되고 있다. 본 논문은 진공 열증착법을 이용하여 증착속도(3, 3.8, $4.5\;{\mu}m/min$)에 따라 $20\;{\mu}m$ 두께의 CsI 필름을 제조하였고, XRD 및 SEM 분석을 통해 CsI 필름의 기하학적 구조를 조사하였다. 증착된 CsI 필름은 증착속도에 관계없이 복잡한 다결정 구조를 가지며, $3\;{\mu}m/min$의 증착속도에서 약 $1\;{\mu}m$ 크기로 needle-like 한 columnar structure를 가졌다. As results, about 3um/min evaporation rate formed as good geometry characteristics CsI layer.

  • PDF

Behavior of Solid Phase Crystallizations in Mechanical Damage Induced Hydrogenated and Non-Hydrogenated Amorphous Amorphous Silicon Thin Films (기계적 Damage 활성화 효과에 대한 수소화 및 비수소화 비정질 규소 박막의 고상 결정화 거동)

  • Kim, Hyeong-Taek;Kim, Yeong-Gwan
    • Korean Journal of Materials Research
    • /
    • v.6 no.4
    • /
    • pp.436-445
    • /
    • 1996
  • 비정질 실리콘박막의 고상결정화 특성에 대한 비정질 박막의 증착방법, 수소화 정도, 표면결정 활성화 에너지 변화 및 열처리 환경 영향을 X선 회절, EDAX, Raman 분광 분석으로 조사하였다. 저온(58$0^{\circ}C$)열처리 corning 시료에서 기판 barium(Ba), aluminum(AI) 성분의 막내 확산 임계열처리시간 및 확산에 기인 한 불안정 결정화 특성을 관찰하였다. 화학기상증착 석영 수소화 시료에서 hard damage 기계적 활성화 효과로 얻어진 조대결정립 결정화 특성을 X선 회절의 (111) 배향 상대강도 변화로 관찰 할 수 있었으며, 이는 활성화 효과에 의한 고상 결정화 시 핵생성과 성장속도변화로 다결정 실리콘의 전기적물성 향상 가능성을 보여주었다. Soft damage, bare 활성화 처리 수소화막의 결정화는 비정질 상의 혼재, 박막 응력등의 저품위 입계특성 및 미세결정립 성장 특성으로 관찰되었으나, 활성화 전처리에 의한 저온 및 고온(875$^{\circ}C$)단시간(30분) 결정화는 확인 되었다. 스퍼터링 비수소화 막의 결정화는 상변태 상태의 Raman 결정피크로 분석 되었으며, 결정화 거동에 선행막의 스퍼터링 및 비수소화 영향은 활성화효과에 관계없이 불완전 저품위 결정특성으로 확인되었다. AFM 표면형상은 3차원 island 성막특성을 보여주었고 표면거칠기정도는 높은 것으로 관찰되었다.

  • PDF

On the Growth of GaN Single Crystal from GaOOH Powders (GaOOH 분말로부터 GaN 단결정 성장에 관하여)

  • 이재범;이종원;박인용;김선태
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2003.03a
    • /
    • pp.96-96
    • /
    • 2003
  • 벌크 형태의 CaN 단결정 성장은 매우 곤란한 관계로 아직까지 관련 기술의 개발이 미흡한 실정이다 오랜 기간동안 승화 (sublimation)법으로 대구경 벌크 GaN 단결정을 성장시키고자 하는 노력이 지속되었지만 최근까지도 만족할 만한 결과가 보고되지 않고 있다. 본 논문에서는 종래의 방법과는 달리 출발물질로서 GaOOH 분말을 채택하고, 이를 NH$_3$ 분위기에서 가열 반응시켜 GaN 결정을 성장시켰다. 반응온도와 반응시간 및 NH$_3$ 유량 등의 성장조건에 따른 GaN 결정의 성장거동과 광학적 특성을 조사하였다. 원료인 GaOOH 분말 1g을 석영 용기에 담아 직경이 35mm인 석영 보호관에 위치시키고, 1000~l17$0^{\circ}C$의 온도에서 NH$_3$ 가스를 100~1000 sccm으로 공급하면서 96시간 동안 반응시켰다. 실험이 종료되면 전기로의 온도를 상온까지 냉각시킨 후 석영 보호관 내벽에 성장된 Ga 결정을 채집하였다. 이와 같이 채집된 결정의 형태와 크기를 광학현미경을 사용하여 조사하였고, 결정표면의 상태를 전자현미경을 사용하여 관찰하였다. 시료의 결정성을 알아보기 위하여 X선 회절 분석을 하였고, 저온에서의 광루미네센스 (PL; photoluminescence) 특성을 조사하였다.

  • PDF

Avascular Necrosis of Femoral Head on Bone Scan (대퇴골두 무혈성 괴사의 뼈스캔상의 병기)

  • Yang, Hyung-In;Kim, Eui-Jong;Kim, Deog-Yoon;Ryu, Kyung-Nam;Cho, Kyung-Sam
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.2
    • /
    • pp.206-213
    • /
    • 1994
  • We studied 90 patients(179 femoral heads) with avascular necrosis of femoral head, who had been performed X-ray, bone scan and MRI to compare of the findings of AVN on bone scan between each other, retrospectively. The patients were 82 males and 9 females, their mean age was 45 years. Radiographic stages were classified by Steinberg modification, radionuclide stages were classified as followed; stage o(or type 0) : normal, stage 1 : faint ring like uptake around the femoral head, stage 2: intense ring like uptake, stage 3: irregular increased uptake with central photon defect, stage 4 : Intense diffuse increased uptake at femoral head and stage 5 : hip joint deformity with relatively mild increased uptake. The findings of MRI were classified according to extent, location, early or advanced lesion, signal intensity of the lesion and joint effusion. 156(87%) of 179 femoral heads had avascular necrosis, 68(75.5%) of 90 patients had bilateral AVN, 35 femoral heads had early stage and 120 had advanced stage. The detection rate of AVN by X-ray and bone scan were 85% (134), 91.6% (143), respectively. Early AVN with atypical types of bone scan showed larger extent, moderate to large amount of joint effusion, soft tissue hypertrophy within joint, and secondary degenerative changes. Bone scan had relatively high detection rate in the diagnosis of AVN of femoral head, and demonstrated various types depending on the disease stage.

  • PDF

Phase Analysis of Mechanically Alloyed $\sigma$-VFe Alloy Powders by Neutron and X-ray Diffraction (기계적 합금화한 $\sigma$-VFe합금의 중성자 및 X선 회절에 의한 상분석)

  • Lee, Chung-Hyo;Jo, Jae-Mun;Lee, Sang-Jin;Sim, Hae-Seop;Lee, Chang-Hui
    • Korean Journal of Materials Research
    • /
    • v.11 no.8
    • /
    • pp.661-665
    • /
    • 2001
  • The mechanical alloying (MA) effect in $\sigma$-VFe intermetallic compound was studied by neutron and X-ray diffraction. The structure of MA $\sigma$-VFe powders were characterized by the X- ray diffraction with Cu- $K\alpha$ radiation and neutron diffraction with monochromatic neutrons of $1.835\AA$ using a high resolution powder diffractometer (HRPD). Mechanical alloying of $\sigma$-VFe compound gives rise to a dramatic structural change. After 60 hours of MA, the Fe-Fe distribution of the $\sigma$- phase VFe tetragonal structure with 30 atoms in a unit cell is found to change into that of the $\sigma$-(V,Fe) solid solution with bcc structure, which is a stable phase at elevated temperature above $1200^{\circ}C$. A comparison of X-ray diffraction data for the $\alpha$-phase has been also made with the corresponding neutron diffraction data. The (101) and (111) diffraction peaks of the $\sigma$-phase was clearly observed only in neutron diffraction pattern, which is believed to be a characteristic feature due to the chemical atomic ordering of $\sigma$- VFe phase.

  • PDF

Evaluation of Scattered Rays of Jelly Type Shielding Body by L-spine AP using X-ray (L-Spine X-선 촬영에서의 Jelly type 차폐체의 산란선 차폐평가)

  • Jang, Hui-Min;Kim, Do-Gwon;Kim, Hyeong-Bin;Yoon, Joon
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.7
    • /
    • pp.907-913
    • /
    • 2020
  • There have been continuous controversies on medical X-ray protection and numerous researchers have been trying to prevent unnecessary exposure to radiation. As X-ray passes through the patient and obtains an image, it creates scattered ray due to interactions such as photoelectric effect and Compton scattering with the subject. As a result, both medical radiation staff and patient are exposed to unnecessary radiation on areas other than the target area. In response, this study will be assuming a body of a female, radiating X-ray on the phantom under the conditions of lumbar spine AP test, and measuring scattered ray around breasts and thyroid glands. Then, The experiment results were as follows. After application of non-shielding material, the average of scattered ray was 0.88 mR in thyroid measurement, 3.34 mR, Lt Axillary 3.54 mR, and Rt Axillary 3.03 mR in mamonary measurement but, After application of shielding material, the average of scattered ray was 0.16 mR in thyroid measurement, 0.60 mR, Lt Axillary 0.64 mR, and Rt Axillary 0.54 mR in mamonary measurement showing average scattered ray protection effect of about 82%. This study suggested the manufacturing method of a Jelly-type shielding material, identified the possibilities of researches on mixing various substances with radiology field, and verified the usability of the Jelly-type shielding material as a substitute for existing protection tools.

Spatial dose distribution and exposure dose during lumbar lateral test (요추 측면 검사 시 공간선량 분포와 피폭선량)

  • Kim, Chang-Gyu
    • Journal of the Korea Convergence Society
    • /
    • v.5 no.1
    • /
    • pp.17-22
    • /
    • 2014
  • During the lateral x-ray testing of lumbar, in order to obtain the optimal image for diagnosis and to minimize the exposure dose, a glass dosimeter and spatial dose measuring meter was used to measure and evaluate the exposure dose and spatial dose distribution of each organs. The exposure dose of the organs have increased as they were closer to the X-ray tube and when the radiation field was completely opened, the exposure dose was increased. In addition, scattered rays have increased as the distance got closer to the subject and with the distance of more than 200cm, 95% of scattered rays was reduced. Such results can anticipate the exposure dose of patients during the lumbar x-ray test in the future and it can be proposed as a data for determining the testing methods and expected to be widely used as an important basic data for reducing the medical exposure dose.

Evaluation of Usability and Radiation Dose Measurement Using Personal Radiation Exposure Dosimeter (방사선 개인피폭선량계를 이용한 피폭선량 측정 및 유용성 평가)

  • Kang, In-Seog;Ahn, Sung-Min
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.11
    • /
    • pp.864-870
    • /
    • 2014
  • To propose a basis for the selection of personal dosimeters to measure radiation dose administration of radiation workers as a way to evaluate the usefulness dosimeter. For the dosimetry of the radiation workers 2012, during 1 year, 30 were radiation workers to measure personal dose. By personal exposure is measured cumulative dose, is investigated the performance of the TLD, PLD, OSLD. And comparing the measured value of each dosimeter dose and analyzed. Medical institutions, inspection work and quarterly confirmed the cumulative exposure dose of radiation workers. Using DAP and Ion-Chamber, to measure to compare TLD, PLD, OSLD dosimeter performance. A comparison of the directly through the X-ray dosimeter and The absolute value of the Ion-Chamber, OSLD more similar than in the TLD and PLD showed the dose values so the excellent ability to measure the results. Also in radiation generating area dose of radiation workers is higher than that in OSLD. Consequently, in terms of the individual exposure management OSLD is appropriated and beneficial than others.