• Title/Summary/Keyword: Worktable

Search Result 34, Processing Time 0.019 seconds

Solution to Decrease Spatial Dose Rate in Laboratory of Nuclear Medicine through System Improvement (시스템 개선을 통한 핵의학 검사실의 공간 선량률 감소방안)

  • Moon, Jae-Seung;Shin, Min-Yong;Ahn, Seong-Cheol;Yoo, Mun-Gon;Kim, Su-Geun
    • Quality Improvement in Health Care
    • /
    • v.20 no.1
    • /
    • pp.60-73
    • /
    • 2014
  • Objectives: This study aims at decreasing spatial dose rate through work improvement whilst spatial dose rate is the cause of increasing personal exposure dose which occurs in the process of handling radioisotope. Methods: From February 2013 until July 2013, divided into "before" and "after" the improvement, spatial dose rate in laboratory of nuclear medicine was measured in gamma image room, PET/CT-1 image room, and PET/CT-2 image room as its locations. The measurement time was 08:00, 12:00 and 17:00, and SPSS 21.0 USA was opted for its statistical analysis. Result: The spatial dose rate at distribution worktable, injection table, the entrance to the distribution room, and radioisotope storage box, which had showed high spatial dose rate, decreased by more than 43.7% a monthly average. The distribution worktable, that had showed the highest spatial dose rate in PET/CT-1 image room, dropped the rate to 42.3% as of July. The injection table and distribution worktable in the PET/CT-2 image room also showed the decline of spatial dose rate to 89% and 64.4%, respectively. Conclusion: By improving distribution process and introducing proper radiation shielding material, we were able to drop the spatial dose rate substantially at distribution worktable, injection table, and nuclide storage box. However, taking into account of steadily increasing amount of radioisotope used, strengthening radiation related regulations, and safe utilization of radioisotope, the process of system improvement needs to be maintained through continuous monitoring.

Study on CNC plasma-cutting worktable with improved lifetime (CNC 플라즈마 절단 작업테이블의 수명 향상에 관한 연구)

  • Na, Yeong-min;Lee, Hyun-seok;Kang, Tae-hun;Park, Jong-kyu
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.14 no.3
    • /
    • pp.112-123
    • /
    • 2015
  • There are many systems for cutting plates or pipes into a desired shape. A typical system is a plasma cutter. It uses plasma, which means that an effective design of the table supporting the workpiece is an important issue in order to ensure a long operational career. Conventional roller-support worktables have a short lifespan due to scratches from the plasma, and it is also difficult to maintain the roller balance. By using a bolt-fastening method, deformation and failure of the final product can occur due to the stress concentration at bolting points. To escape these issues, a polygon support and bracket fastening method was designed. Due to polygons having a number of support surfaces, when one surface has been damaged, it is possible to reuse the support by utilizing a different surface. The bracket-fastening method can extend the worktable lifetime and increase productivity by reducing stress concentration. In this paper, the polygon support/bracket-fastening method is compared with existing technologies. Consequently, performance benchmarks are verified through a structure analysis and experimentation.

Camera Calibration and Pose Estimation for Tasks of a Mobile Manipulator (모바일 머니퓰레이터의 작업을 위한 카메라 보정 및 포즈 추정)

  • Choi, Ji-Hoon;Kim, Hae-Chang;Song, Jae-Bok
    • The Journal of Korea Robotics Society
    • /
    • v.15 no.4
    • /
    • pp.350-356
    • /
    • 2020
  • Workers have been replaced by mobile manipulators for factory automation in recent years. One of the typical tasks for automation is that a mobile manipulator moves to a target location and picks and places an object on the worktable. However, due to the pose estimation error of the mobile platform, the robot cannot reach the exact target position, which prevents the manipulator from being able to accurately pick and place the object on the worktable. In this study, we developed an automatic alignment system using a low-cost camera mounted on the end-effector of a collaborative robot. Camera calibration and pose estimation methods were also proposed for the automatic alignment system. This algorithm uses a markerboard composed of markers to calibrate the camera and then precisely estimate the camera pose. Experimental results demonstrate that the mobile manipulator can perform successful pick and place tasks on various conditions.

A Vibration Isolation System Design for a Vibration-sensitive Equipment (정밀 가공 장비를 위한 방진 시스템 설계 사례)

  • Hong, Seok-In;Kim, Ho-Sang;Lee, Dae-Hee;Lee, Kyung-Don;Jang, Han-Kee
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.3 s.108
    • /
    • pp.307-312
    • /
    • 2006
  • In this study a vibration isolation system with the cradle-type support was designed so as to reduce the transient vibration due to positioning motion of the moving mass on worktable as well as to achieve the desired isolation efficiency on the floor vibration. The design procedure was performed in the two steps. The first step to select appropriate isolators to meet the isolation efficiency, and the second step is to reduce the transient vibration of the worktable by adopting the cradle-type support. After the application of the selected isolators with the cradle-type support to the system it was shown that the required vibration criterion(VC-D) was easily satisfied and that the undesirable transient vibration was reduced remarkably.

Numerical Ananlysis on the Tubulent Flow and Heat Transfer in the Tunnel Laminar Flow Type Clean Room(1) (터널층류방식 청정실에서의 난류운동과 열전달에 관한 수치해석(1))

  • 정한식;정효민
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.19 no.4
    • /
    • pp.27-33
    • /
    • 1995
  • The turbulent flow and heat transfer in the tunnel laminar flow type clean room is investigated by a numerical simulation. The model clean room is assumed to be a rectngular $5m\times3m$, in which a worktable of 0.75m hight, and 1.5m or 3m long at the floor. Major parameters are the inlet flow velocity, inlet hole size and worktable surface distance. The mean Nusselt number is increased by increasing Reynolds number and can be expressed by the correlation equation.

  • PDF

A Calibration of Kinematic Differences between the Robot Model in OLP and Actual SCARA Robot

  • Ahn, Cheol-Ki;Lee, Min-Cheol
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1998.10a
    • /
    • pp.111-116
    • /
    • 1998
  • In this study, we try to coincide virtual robot system in an OLP(off-line programming) with actual robot system even though kinematic differences between them are made. The virtual robot in the OLP may be modeled according to kinematics of the actual robot system. However, it is a complicated problem to find exactly all kinematic parameters of actual robot and environment. In this paper, an automated calibration method is proposed In order to find some kinematical parameters which are necessary for the modeling of a robot and environment in the OLP. It is applicable to SCARA robot for assembly task. In this method, a well-marked worktable of environment Is regarded as reference coordinate frame. The robot detects some marks on the worktable through sensors attached to the end-effector. The necessary parameters are calculated from the data of the robot joint variables when the robot detects the mark. The model in the OLP is modified by the parameters.

  • PDF

A Study on the Modular System for the Kitchen Furniture Design (주방 가구디자인 모듈개발에 관한 연구)

  • Choj, Ji-Young;Park, Young-Soon
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2005.10a
    • /
    • pp.61-64
    • /
    • 2005
  • The purpose of this study is developing basic module of kitchen furniture design by considering the dimensions of work-surfaces, such as the size of worktable and the length of the kitchen furniture based on the physical size of a human scale and the behavior in the kitchen and the size of goods. In conclusion, this study develops a basic module of the kitchen furniture and suggests the new dimension for the kitchen based on the human scale and demand for the kitchen goods thus, it is expected to use it as a basic data for the kitchen space study and kitchen furniture industry.

  • PDF

Living Environment, Musculoskeletal Disorder and the Decrease of Work Efficiency & Quality of Life (생활 환경요인에 의한 근골격계 질환이 업무능률 및 삶의 질 저하에 미치는 영향)

  • Park, Jong-Ho;Kim, Eun-Jeong
    • The Journal of Industrial Distribution & Business
    • /
    • v.8 no.7
    • /
    • pp.63-70
    • /
    • 2017
  • Purpose - Due to the lack of physical activities and the increase of sedentary behaviors such as screen time, the health condition for contemporaries has been deteriorating. This study is designed to investigate how the use of worktable or tools unfit for body and sedentary behaviors can exercise influence on muscular skeletal disease and how it has an impact on lowering work efficiency and the quality of life with the medium of the muscular skeletal disease. Research design, data, and methodology - The research has developed a questionnaire with 5 hypothesis. The questionnaires were also made by interview and E-mail. 350 copies of questionnaires were distributed and 315 questionnaire were used for the analysis as valid data responses. SPSS ver.22.0 were used and made Cronbach's and reliability test, correlation, Baron & α Kenny 3 step mediated regression analysis. Results - The research has found that living environment factors have positive effect on the occurrence of musculosketal disease. Particularly, repeated use of unfit worktable or tools has a positive effect on the muscular skeletal disorder. And sedentary lifestyle also has a positive effect on the disease. The musculoskeletal disease caused by living environment has a positive impact on lowering the work efficiency. This study has also showed that the muscular skeletal disease has mediated the relationship between the living environment factors and the decrease of work efficiency due to musculoskeletal disease. The musculoskeletal disorders can effect the decrease of the quality of life as well, for the decrease of work efficiency has a positive effect on lowering the quality of life. Conclusions - Sedentary lifestyles, the use of worktable unfit for body, and the repeated use of a tool have caused the increase of muscular-skeletal diseases, and reduction of productivity as well as the hight cost of medical treatment for our contemporaries. Understanding the cause of disease morbidity, finding ways to prevent the disease, and educating people about them would contribute not only to improvement of individual health but also to the advancement of welfare for all.

An Anthropometric Product Design Approach Using Design Structure Matrix (DSM): Application to Computer Workstation Design (Design Structure Matrix를 활용한 인체측정학적 제품설계 방법: 컴퓨터 워크스테이션 설계 적용)

  • Jung, Ki-Hyo;Kwon, O-Chae;You, Hee-Cheon
    • Journal of the Ergonomics Society of Korea
    • /
    • v.26 no.3
    • /
    • pp.111-115
    • /
    • 2007
  • Design equations for anthropometric product design are developed by considering the geometrical relationships of design dimensions and anthropometric dimensions. The present study applied the design structure matrix (DSM) method to the development of design equations for a computer workstation, and compared design values from the design equations with corresponding design values of ergonomic recommendations and existing products. The relationships between design dimensions (e.g., legroom and worktable) were analyzed by a DSM, and then the application order of design equations (e.g., seatpan, backrest, armrest, legroom, and worktable in descending order) was determined. Next, design equations were developed by analyzing the geometric relationships between computer workstation design dimensions and anthropometric dimensions. Finally, design values for a computer workstation were determined by considering a standard posture defined and representative human models (5th, 50th, 95th %ile). The design values calculated using the design equations were similar with those of ergonomic recommendations found in literature and two commercial products measured in the study; however, some design values (e.g., seatpan height) were different due to discrepancy in standard posture. The DSM method would be utilized to systematically analyze the relationships between design dimensions for anthropometric product design.

The Study on Musculoskeleta Disorders Prevention at a Semi-finished Medical Products Fabricating Company (의약품 중간원료 제조사업장에서 근골격계 질환 예방에 관한 연구)

  • Kang, Young-Sig;Yang, Sung-Hwan;Cho, Mun-Son
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2006.11a
    • /
    • pp.23-37
    • /
    • 2006
  • This paper describes the effective way of finding injurious that prevents the workers against musculoskeletal disorders at a semi-finished medical products fabricating company. Analytical method is adopted a questionnaire an ergonomic assessment. The result of this paper is suggested the working environment, improvement of worktable, working space, tools, and outfit.

  • PDF