• 제목/요약/키워드: Works efficiency

검색결과 833건 처리시간 0.024초

브로드벡 하우스와 오이리트메움의 건축 특성과 의미에 관한 연구 (A Study on the Architectural Characteristics and Its Implications in Eurythmeum Anbau zu Haus Brodbeck)

  • 우창옥;김문덕
    • 한국실내디자인학회논문집
    • /
    • 제23권5호
    • /
    • pp.165-173
    • /
    • 2014
  • Located in Dornach, Switcherland Eurythmeum Anbau zu Haus Brodbeck (Rudolf Steiner-Halde, Eurythmeum Anbau zu Haus Brodbeck, 1923-1935) is one of the architectural works created by Rudolf Steiner (1861-1925) who has studied and established the cognitive and spiritual aspects of a human being, and is often cited as being the founder of anthroposophy. In fact, Eurythmeum Anbau zu Haus Brodbeck is not as well known as Steiner's other works, and it is perceived as less important than his major works of architecture including "Goetheanum", "Modellbau zu Malsch", and "Rudolf Steiner Haus Stuttgart". Nonetheless, this study is meaningful in itself since it is an important piece of architecture to gain an understanding of the characteristics of Steiner's late works, and the architectural characteristics of the Waldorf School where various active educational activities are taking place around the world. Eurythmeum Anbau zu Haus Brodbeck clearly exhibits the characteristics of the architectural space based on Steiner's anthroposophy as well as provides a window into promoting space efficiency by extending an existing building. Moreover, it provides a good learning opportunity to find out about how Steiner's architectural disposition has changed and developed with the use of new materials. With these points as a backdrop, the study aims to develop an understanding of the architectural characteristics of Eurythmeum Anbau zu Haus Brodbeck. Another important objective of this paper is to gain insight into the architectural implications in connection with the influence Eurythmeum Anbau zu Haus Brodbeck has had on Steiner's later works, by comparing his early works of architecture with those of his late works.

A Novel BIRA Method with High Repair Efficiency and Small Hardware Overhead

  • Yang, Myung-Hoon;Cho, Hyung-Jun;Jeong, Woo-Sik;Kang, Sung-Ho
    • ETRI Journal
    • /
    • 제31권3호
    • /
    • pp.339-341
    • /
    • 2009
  • Built-in redundancy analysis (BIRA) is widely used to enhance the yield of embedded memories. In this letter, a new BIRA method for both high repair efficiency and small hardware overhead is presented. The proposed method performs redundancy analysis operations using the spare mapping registers with a covered fault list. Experimental results demonstrate the superiority of the proposed method compared to previous works.

  • PDF

제어시스템 튜닝에 의한 발전소 효율향상에 관한 연구 (A Study on Efficiency Improvement by Fine Tuning of Power Plant Control)

  • 김호열;김병철;변승현
    • 전기학회논문지
    • /
    • 제61권10호
    • /
    • pp.1496-1501
    • /
    • 2012
  • A fine tuning on a control system is essential not only for stable operation but also for efficient operation of the power plant. There has been a very few studies on efficiency change by control system tuning. So, it was not clear that if it could be improved or not when the control is stable by fine tuning and how much it could be improved if it works. An accurate algorithm for measurement of the plant efficiency was newly introduced and implemented to measure integrated fuel flow and electricity MW output and to calculate the mean efficiency for given time. As a result, stable operation after fine tuning of control parameters for major controlled variables brought higher efficiency than un-stable operations like a cycling or an oscillation. The plant efficiency has been monitored during various tests and tunings to confirm how much it changes by tuning of the control system on power plant. Now, we can say that the efficiency can be improved in stable operation by fine tuning of the control system.

조향 가능한 전방향 바퀴를 갖는 전방향 이동로봇의 에너지 효율 개선 (Improvement of Energy Efficiency for an Omnidirectional Mobile Robot with Steerable Omnidirectional Wheels)

  • 송재복;김정근
    • 제어로봇시스템학회논문지
    • /
    • 제11권8호
    • /
    • pp.696-703
    • /
    • 2005
  • Since most autonomous mobile robots are powered by a battery, it is important to increase the continuous operating time without recharging. This can be achieved by improving the energy efficiency of a mobile robot, but little research on energy efficiency has been performed. This paper proposes two methods for improving the energy efficiency of an omnidirectional mobile robot.. One method is to realize a continuously variable transmission (CVT) by adopting the mechanism of steerable omnidirectional wheels. The other is the proposed steering algorithm in which wheel arrangement of the mobile robot is continuously adjusted so as to obtain the maximum energy efficiency of the motors during navigation. In addition, new omnidirectional wheels which can be transformed to the conventional wheels depending on the driving conditions are proposed to compensate for less efficient omnidirectional drive mode. Various tests show that motion control of the OMR-SOW works satisfactorily and the proposed steering algorithm for CVT can provide higher energy efficiency than the algorithm using a fixed steering angle. In addition, it is shown that the differential drive mode can give better energy efficiency than the omnidirectional drive mode.

Islamic Bank Efficiency in Indonesia: Stochastic Frontier Analysis

  • OCTRINA, Fajra;MARIAM, Alia Gantina Siti
    • The Journal of Asian Finance, Economics and Business
    • /
    • 제8권1호
    • /
    • pp.751-758
    • /
    • 2021
  • This research is conducted to measure the efficiency level of Islamic banking in Indonesia and also to analyze the factors that can affect its efficiency level. This research used a purposive sampling technique to determine the sample size that will be used, with criteria that the bank has been operating since 2010 and consistently published its financial reports during the research period from 2011 until 2019; therefore, the total sample obtained was 11 samples. Analysis for efficiency level is done by using linear programming Stochastic Frontier Analysis (SFA), with test tool in the form of Frontier 4.1 and Eviews9 to find out what factors that affect efficiency. Efficiency test is done by involving input and output, while influence test used bank-specific variables comprising bank size, bank financial ratio, and macro-economy variable. Research result shows that there are only two banks that are almost close to being fully efficient firms, but the result still does not indicate that Islamic bank works efficiently. Results of the influence test show that factors affecting Islamic banking efficiency in Indonesia are bank size, Capital Adequacy Ratio (CAR), Non-Performing Finance (NPF), and Financing to Deposit Ratio (FDR), while other factors are not influential over the study period.

고효율 5A용 동기식 DC-DC Buck 컨버터 (High Efficiency 5A Synchronous DC-DC Buck Converter)

  • 황인환;이인수;김광태
    • 한국멀티미디어학회논문지
    • /
    • 제19권2호
    • /
    • pp.352-359
    • /
    • 2016
  • This paper presents high efficiency 5A synchronous DC-DC buck converter. The proposed DC-DC buck converter works from 4.5V to 18V input voltage range, and provides up to 5A of continuous output current and output voltage adjustable down to 0.8V. This chip is packaged MCP(multi-chip package) with control chip, top side P-CH switch, and bottom side N-CH switch. This chip is designed in a 25V high voltage CMOS 0.35um technology. It has a maximum power efficiency of up to 94% and internal 3msec soft start and fixed 500KHz PWM(Pulse Width Modulation) operations. It also includes cycle by cycle current limit function, short and thermal shutdown protection circuit at 150℃. This chip size is 2190um*1130um includes scribe lane 10um.

보안 및 효율성을 고려한 관광 예약 정보 시스템 (Tourism Information Reservation System considering the Security and Efficiency)

  • 김태경
    • 디지털산업정보학회논문지
    • /
    • 제11권2호
    • /
    • pp.67-72
    • /
    • 2015
  • As new Information technology such as IoT develops rapidly, a lot of changes are occurred in our lives. The Internet of Things is the network of physical objects or things embedded with electronics, software, sensors and connectivity to enable it to achieve greater value and service by exchanging data with the manufacturer, operator and/or other connected devices. This change is also applied to tourism industry. These days many people make a tour reservation using the internet. But it is required to consider the efficiency and security of tour reservation system. In this paper, we suggest a tour reservation system. First, we describe the computer reservation system, hotel reservation system and reservation system. Second, we perform the modeling of general reservation system and suggested reservation system. Third, performance evaluation is carried out with respect to efficiency and security. The results show that the suggested reservation system has a better performance than a general reservation system. At last we described the results and future works.

2단 평행판 전기집진기의 서브마이크론입자 집진성능 개선 연구 (Study on improvement of submicron particle collection performance in 2-stage parallel-plate electrostatic precipitators)

  • 유경훈;오명도;이준식
    • 설비공학논문집
    • /
    • 제9권3호
    • /
    • pp.323-332
    • /
    • 1997
  • It was reported by some researchers that two-stage parallel-plate ESPs, commonly called electronic air cleaners, show decreasing behavior of collection efficiency as particle size decreases below about $0.03{\mu}m$. This phenomenon is attributed to partial particle charging characteristics, where some of incoming particles are not charged in the charging cell of 2-stage parallel-plate ESP. One way to improve the decreasing collection efficieny in that particle size range is to enforce particle charging quantity in the charging cell. In the present study, in order to do this a 2-wire series-type charging cell modified from a 1-wire normal-type one was suggested and investigated theoretically and experimentally concerning improvement of the collection efficiency. It was confirmed from the experimental and theoretical works that the collection efficiency was apparently improved.

  • PDF

PFC용 부스트 컨버터의 병렬화에 의한 효율 개선 (An Improvement Parallel to the Efficiency of Boost Converter for Power Factor Correction)

  • 전내석;장수형;전일영;박영산;안병원;이성근;김윤식
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2001년도 추계학술대회 논문집(Proceeding of the KOSME 2001 Autumn Annual Meeting)
    • /
    • pp.120-124
    • /
    • 2001
  • A new technique for improving the efficiency of single-phase high-frequency boost converter is proposed. This converter includes an additional low-frequency boost converter which is connected to the main high-frequency switching device in parallel. The additional converter is controlled at lower frequency. Most of the current flows in the low-frequency switch and so, high-frequency switching loss is greatly reduced accordingly Both switching device are controlled by a simple method; each controller consists of a one-shot multivibrator, a comparator and an AND gate. The converter works cooperatively in high efficiency and acts as if it were a conventional high-frequency boost converter with one switching device. The proposed method is verified by simulation. This paper describes the converter configuration and design, and discusses the steady-state performance concerning the switching loss reduction and efficiency improvement.

  • PDF

Model Tree기법을 이용한 정수처리공정에서의 응집/침전 효율 예측에 관한 연구 (Establishment of the Refined Model for Prediction of Flocculation/Sedimentation Efficiency Using Model Tree Technique)

  • 박노석;박상영;김성수;정남정;이선주
    • 상하수도학회지
    • /
    • 제20권6호
    • /
    • pp.789-797
    • /
    • 2006
  • This study was conducted to establish the refined model for prediction of flocculation/sedimentation efficiency in factual drinking water treatment plants using model tree technique. In order to carry out machine leaning for determining each linear model, five parameters; time, coagulant dose, raw water turbidity, SCD and conductivity, which were measured and collected from the field (K_DWTP), were selected and used. The existing analytical models developed by previous researchers were used only to examine closely the mechanism of flocculation rather than to apply it for practical purpose. The refined model established using model tree technique in this study could predict the factual sedimentation efficiency accurately (below 9% of average absolute error). Also, in aspect of engineering convenience, without any additional manipulation of parameters, it can be applied to practical works.