• Title/Summary/Keyword: Workplace monitoring

Search Result 134, Processing Time 0.024 seconds

The Occupant Perception and Investigation of Indoor Air Quality at Home in Seoul

  • Sohn, Jong-Ryeul;Kim, Young-Whan;Byeon, Sang-Hoon
    • Journal of environmental and Sanitary engineering
    • /
    • v.18 no.1
    • /
    • pp.51-57
    • /
    • 2003
  • Indoor air quality(IAQ) in workplace and residential environments has been concern of people. Recently, Ministry of Environment in Korea has recognized the potential risk on the healthy effect related to indoor air pollution at home. Therefore, the purpose of this study was performed to measure the indoor air pollutants of IAQ at different homes and investigate to compare the perception of IAQ recognition at home from questionnaire survey in Seoul. We estimated the IAQ of selected 6 homes based on site region and housing type. The indoor air pollutants and parameters such as temperature, relative humidity, respirable suspended particulate matter($PM_{10}$), formaldehyde(HCHO), total bacteria counts, carbon monooxide(CO) and carbon dioxide($CO_2$) were monitored for summer and winter. In monitoring results, the respirable suspended particulate matter(($PM_{10}$) and indoor airborne bacteria level of home 5 and 6 were higher than the standard of the public $150{\;}{\mu}g/m^3$ and $500{\;}{\mu}g/m^3$, the level formaldehyde(HCHO) was exceed 0.1 ppm of the standard of Korea at all monitored homes. In statistics analysis, we could find a correlation between the building age and the concentration of CO, TBC were significant at 0.01 level and Relative Humidity was significant at 0.05 level for summer. Finally, the important air pollutants of IAQ in home were HCHO and total bacteria counts(TBC). And we performed a questionnaire survey of 500 people about their awareness for the importance of IAQ in our home during same period. In results, all most response of occupant has recognized the importance of IAQ at home. Therefore, it can be concluded that the IAQ of selected 6 home studied was perceived as acceptable, it is recommended that the government related IAQ was suggested the guideline and control of IAQ problems, and the occupants need to be effort to reduce the exposure of sources to undesirable pollutants.

Biological Monitoring of Paint Handling Workers exposed to PAHs using Urinary 1-Hydroxypyrene (다핵방향족탄화수소류에 노출된 페인트 취급 근로자에서 요 중 1- Hydroxypyrene을 이용한 생물학적 모니터링)

  • Lee, Jong-Seong;Kim, Eun-A;Lee, Yong-Hag;Moon, Deog-Hwan;Kim, Kwang-Jong
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.15 no.2
    • /
    • pp.124-134
    • /
    • 2005
  • To investigate the exposure effect of polynuclear aromatic hydrocarbons (PAHs), we measured airborne total PAHs as an external dose, urinary 1-hydroxypyrene (1-OHP) as an internal dose of PAHs exposure, and analyzed the relationship between urinary 1-OHP concentration and PAHs exposure. The study population contained 44 workers in steel-pipe coating and paint manufacture industries. The airborne PAHs was obtained during survey day, and urine were sampled at the end of shift. Personal information on age, body weight, height, eniployment duration, smoking habit, and alcohol consumption was obtained by a structured questionnaire. Airborne PAHs were analyzed by the gas chromatograph with mass selective detector. Urinary 1-OHP levels were analyzed by the high performance liquid chromatograph with ultraviolet wavelength detector. For statistical estimation, t-test, ${\chi}^2$-test, analysis of variance, correlation analysis, arid regression analysis were executed by SPSS/PC (Windows version 10). The mean of environmental total PAHs was $87.8{\pm}7.81{\mu}g/m^3$. The mean concentration ($526.5{\pm}2.85{\mu}g/m^3$) of workers in steel-pipe coating industries using coal tar enamel was the higher than that ($17.5{\pm}3.36{\mu}g/m^3$) of workers in paint manufacture industries using coal tar paint. The mean of urinary 1-OHP concentration ($51.63{\pm}3.144{\mu}\;mol/mol$ creatinine) of workers in steel-pipe coating industries was the higher than that ($2.33{\pm}4.709{\mu}\;mol/mol$ creatinine) of workers in paint manufacture industries. The mean of urinary 1-OHP concentration of smokers was the higher than that of non-smokers. There was significant correlation between the urinary concentration of 1-OHP and the environmental concentration of PAHs (r=O.S48, p<0.001), pyrene(r=0.859, p<0.001), and urinary cotinine (r=0.324, p<0.05). The regression equation between the urinary concentration of 1-OHP in ${\mu}g/g$ creatinine($C_{1-OHP}$) and airborne concentration of PAHs (or pyrene) in ${\mu}g/m^3$ ($C_{PAHs}$ or Cpyrene) is: Log ($C_{1-OHP}$)=-0.650+0.889×Log($C_{PAHs}$), where $R^2=0.694$ and n=38 for p<0.001.Log ($C_{1-OHP}$)=1.087+0.707${\times}$Log(Cpyrene), where $R^2=0.713$ and n=38 for p<0.001. From the results of stepwise multiple regression analysis about 1-OHP, significant independents were total PAHs and urinary cotinine (adjusted $R^2=0.743$, p<0.001). In this study, there were significant correlation between the urinary concentration of 1-OHP and the airborne concentration of PAHs. The urinary 1-OHP was effective index as a biomarker of airborne PAHs in workplace. But it was influenced by non-occupational PAHs source, smoking.

Formaldehyde Exposure in the Plywood Manufacturing Factory (목재 가공업소에서의 Formaldehyde폭로)

  • Ha, Myung-Wha;Kim, Doo-Hie;Lim, Hyun-Sul;Park, Sang-Hu
    • Journal of Preventive Medicine and Public Health
    • /
    • v.24 no.1 s.33
    • /
    • pp.37-44
    • /
    • 1991
  • In the plywood manufacturing factory established in 1979, female 3 workers who had exposed to adhesives containing formaldehyde for more than 48 months of duration suffered from eye, nasal, oral, throat and skin irritation and dyspnea as chief complaints. The actual level of the exposure to formaldehyde were not estimated when the exposed workers started to have above symptoms. The environmental monitoring of workplace was measured on April 25, 1990, and the concentration of formaldehyde revealed 0.2 ppm, however the exhaustive ventilatory system was already installed at that time. Twenty six subjects from entire factory were examined by questionnaire, physical examination and spirometry, etc. on August 22, 1990. Significant difference was observed in symptoms and signs of nasal, oral and throat irritation between the exposed group with longer duration and that with short duration. When the exposed group with longer duration was compared to the group of nonexposed, symptoms and signs of nasal, oral, throat and skin irritaion, chest tightness and dullness were significantly increased in the former group. The results of the spirometric test showed that the forced vital capacity and the forced expiratory volume at 1 second were decreased among the exposed group with longer duration but not significant.

  • PDF

Microbiological Hazard Analysis of Sundae (Korean Sausage) Made of Meat By-Products (식육 부산물을 활용한 순대의 미생물학적 위해 분석)

  • Cheong, Jin-Sook;Kim, Yun Jeong;Om, Ae-Son
    • Journal of Food Hygiene and Safety
    • /
    • v.37 no.3
    • /
    • pp.181-188
    • /
    • 2022
  • Despite the recent increase in the consumption level of the processed meat-byproducts, the health and safety issue has consistently been raised in the processes of production, distribution and consumption. The purpose of this study is to analyze and evaluate the microbiological hazard elements in the Korean sausage, "Sundae," to present not only the safety standard of meat by-product vendors based on HACCP (Hazard Analysis Critical Control Point), but also the quality control criteria and sanitary arrangements of small manufacturers. For the study, the microbiological hazards in 24 raw materials, 7 manufacturing processes, 40 facilities and tools, 17 workplace environment, and 12 workers were analyzed. The analysis revealed the hazardous elements in the initial stages with 6.28 and 4.07 log CFU/g of total aerobic count and coliforms, respectively, detected from the porcine blood and 3.23 log CFU/g of coliforms from the porcine small intestines. The result also showed that the total aerobic counts and coliforms in the process of mixing and filling process exceeds the standards in the hygiene guidelines by Natick with the total aerobic counts of 5.23, 5.45 log CFU/g, and the coliforms of 3.25, and 3.31 log CFU/g, respectively. Although the detected total aerobic count and the coliforms in the filling and washing rooms exceeded the standards, it was found that the total aerobic count was significantly reduced by 98% after cleaning and disinfecting and no coliforms was detected in any process thereafter. In order to achieve high level of safety in the manufacturing processes of Sundae, the separation of washing and disinfection room from the other sections and the sanitation control of the workers must be preceded, along with strict monitoring in the storage and distribution processes. The study raises necessity for additional studies for the safety evaluation of the processed meat-byproducts and further researches on the validity of the critical limits.