• 제목/요약/키워드: Working capacity

검색결과 593건 처리시간 0.027초

Dynamic Survivable Routing for Shared Segment Protection

  • Tapolcai, Janos;Ho, Pin-Han
    • Journal of Communications and Networks
    • /
    • 제9권2호
    • /
    • pp.198-209
    • /
    • 2007
  • This paper provides a thorough study on shared segment protection (SSP) for mesh communication networks in the complete routing information scenario, where the integer linear program (ILP) in [1] is extended such that the following two constraints are well addressed: (a) The restoration time constraint for each connection request, and (b) the switching/merging capacity constraint at each node. A novel approach, called SSP algorithm, is developed to reduce the extremely high computation complexity in solving the ILP formulation. Basically, our approach is to derive a good approximation on the parameters in the ILP by referring to the result of solving the corresponding shared path protection (SPP) problem. Thus, the design space can be significantly reduced by eliminating some edges in the graphs. We will show in the simulation that with our approach, the optimality can be achieved in most of the cases. To verify the proposed formulation and investigate the performance impairment in terms of average cost and success rate by the additional two constraints, extensive simulation work has been conducted on three network topologies, in which SPP and shared link protection (SLP) are implemented for comparison. We will demonstrate that the proposed SSP algorithm can effectively and efficiently solve the survivable routing problem with constraints on restoration time and switching/merging capability of each node. The comparison among the three protection types further verifies that SSP can yield significant advantages over SPP and SLP without taking much computation time.

$WO_3$를 이용한 박막형 슈퍼캐패시터의 제작 및 특성 평가 (Fabrication and Characterization of Thin Film Supercapacitor using $WO_3$)

  • 신호철;신영화;임재홍;윤영수
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 추계학술대회 논문집
    • /
    • pp.575-578
    • /
    • 2000
  • In this work, all solid-state thin film supercapacitor(TFSC) was fabricated using tungsten trioxide (WO$_3$) with a structure WO$_3$/LiPON/WO$_3$/Pt/TiO$_2$/Si (substrate). After TiO$_2$ was deposited on Si(100) wafer by d.c. reactive sputtering, the Pt current collector films were grown on TiO$_2$glue layer without breaking vacuum by d.c. sputtering. Fabrication conditions of WO$_3$ thin film were such that substrate temperature, working pressure, gas ratio of $O_2$/Ar and r.f. power were room temperature, 5 mTorr, 20% (O$_2$(8sccm)/Ar(32sccm)) and 200W, respectively. LiPON electrolyte film were grown on the WO$_3$ film using r.f. magnetron sputtering at room temperature. The XRD pattern of the as-deposited WO$_3$ thin film were shown no crystalline peak (amorphous). The SEM image of as-deposited WO$_3$ thin film showed that the surface is smooth and uniform. The capacitiy of as-fabricated TFSC was 0$\times$10$^{-2}$ F/$\textrm{cm}^2$-${\mu}{\textrm}{m}$.

  • PDF

농촌현장포럼에서 퍼실리테이터들이 경험하는 어려움에 대한 탐색 (Exploring the Difficulties Experienced by the Facilitators in the Rural Field Forum)

  • 정상숙;리신호
    • 한국농공학회논문집
    • /
    • 제60권5호
    • /
    • pp.95-104
    • /
    • 2018
  • The purpose of this study was to explore the extent of difficulties experienced by facilitators in the rural field forum and to derive a theoretical model for improving the satisfaction of facilitators in the rural field forum. Based on grounded theory, qualitative analysis used data collected through individual in-depth interviews with 10 facilitators who are working at the rural field forum. This collected data was analyzed using the Nvivo 11 program. Using a derived theoretical model, the result of analyzing the difficulties experienced by facilitators in the rural field forum showed the core phenomenon identified as difficulties on-site the forum. There was a clarification of the issues regarding improvement of their labour conditions in order to solve the difficulties on-site the forum. The issues towards improving labour conditions were low allowance, equal assignment, guaranteed four major insurances and so on. The facilitators have been trying to activate the rural field forum by promoting their own capacity through the cooperation between colleagues, post training, seminars, and conferences.

작업자세에 따른 어깨근육의 작업부하 측정 (Measurement of Shoulder Muscle Workload at Various Working Postures)

  • 김정룡;박지수;박창순;편흥국
    • 대한산업공학회지
    • /
    • 제25권2호
    • /
    • pp.266-273
    • /
    • 1999
  • The maximum work capacity at various shoulder angles was estimated in terms of joint moment through maximum voluntary contraction (MVC) measurement, and the result was compared to workload computed from 3-D static lifting model (3DSSPP) based upon national institute of safety and health (NIOSH) lifting guideline (1991). The electromyography (EMG) of anterior/posterior deltoid and trapezius muscle was also recorded to study the function of individual muscle during asymmetric shoulder lifting. Psychophysical workload was measured to observe the difference from MVC or biomechanical estimation. An apparatus was constructed for the study and twenty five trials including five flexion angles and five add/abduction angles were performed isometrically. Results indicated that MVC at 30 degree of flexion was the strongest whereas MVC at 120 degree was the weakest. In case of add/abduction, MVC decreased to 77 to 89 % during add/abduction compared to the MVC at neutral position. Regarding the normalized EMG value, a substantial increase was observed at 30 and 60 degree abduction. More importantly, the shoulder moment computed from maximum permissible limit (MPL) was greater than the moment at MVC condition during 30 degree adduction. Current result can be used as a reference information for a safe workplace design to prevent the shoulder from an excessive work load in industry.

  • PDF

Progresses and new perspectives of integrated operations for a sustainable industrial growth

  • Drioli, Enrico
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 1998년도 추계 총회 및 학술발표회
    • /
    • pp.11-14
    • /
    • 1998
  • 1. Introduction : Research progresses in Chemistry and Chemical Engineering have been made during the last decades with important contributions to the industrial development and to the quality of our life. An interesting case is related to the membrane science and technology continuous impact to innovative processes and products, particularly appropriate for a sustainable industrial growth. Membrane operations have been familiar for many years to biologists and chemists working in their laboratorier or studying biological phenomena. Only recently engineers started to operate in' this area. The preparation of asymmetric CA membranes at University of California, Los Angeles in the early 60s is generally recognized as a crucial moment for membranology (1). Loeb and Sourirajan with their discovery of how to increase significantly the permeability of polymeric membranes without significant changes in their selectivity, made realistic the possibility of their use in large scale operations for desalting brackish and sea water by reverse osmosis and for various other molecular separations in different industrial areas. Reverse osmosis is today a well recognized basic unit operations, togheter with ultrafiltration, crossflow microfiltration,. nanofiltration, all pressure driven membrane processes. Already in 1992 more than 4 milIions m$^3$/day were the total capacity of RO desalination plants and in 1995 more than 180.000 m$^2$ of ultrafiltration membranes were installed for the treatment of wheys and milk (2) (3).

  • PDF

Smart PZT-interface for wireless impedance-based prestress-loss monitoring in tendon-anchorage connection

  • Nguyen, Khac-Duy;Kim, Jeong-Tae
    • Smart Structures and Systems
    • /
    • 제9권6호
    • /
    • pp.489-504
    • /
    • 2012
  • For the safety of prestressed structures such as cable-stayed bridges and prestressed concrete bridges, it is very important to ensure the prestress force of cable or tendon. The loss of prestress force could significantly reduce load carrying capacity of the structure and even result in structural collapse. The objective of this study is to present a smart PZT-interface for wireless impedance-based prestress-loss monitoring in tendon-anchorage connection. Firstly, a smart PZT-interface is newly designed for sensitively monitoring of electro-mechanical impedance changes in tendon-anchorage subsystem. To analyze the effect of prestress force, an analytical model of tendon-anchorage is described regarding to the relationship between prestress force and structural parameters of the anchorage contact region. Based on the analytical model, an impedance-based method for monitoring of prestress-loss is conducted using the impedance-sensitive PZT-interface. Secondly, wireless impedance sensor node working on Imote2 platforms, which is interacted with the smart PZT-interface, is outlined. Finally, experiment on a lab-scale tendon-anchorage of a prestressed concrete girder is conducted to evaluate the performance of the smart PZT-interface along with the wireless impedance sensor node on prestress-loss detection. Frequency shift and cross correlation deviation of impedance signature are utilized to estimate impedance variation due to prestress-loss.

Performance Comparison of Liquid-Cooling with Air-Cooling Heat Exchangers Designed for Telecommunication Equipment

  • Jeon, Jong-Ug;Choi, Jong-Min;Heo, Jae-Hyeok;Kang, Hoon;Kim, Yong-Chan
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제16권2호
    • /
    • pp.64-69
    • /
    • 2008
  • Electronic and telecommunication industries are constantly striving towards miniaturization of electronic devices. Miniaturization of chips creates extra space on PCBs that can be populated with additional components, which decreases the heat transfer surface area and generates very high heat flux. Even though an air-cooling technology for telecommunication equipment has been developed in accordance with rapid growth in electrical industry, it is confronted with the limitation of cooling capacity due to the rapid increase of heat density. In this study, liquid-cooling heat exchangers were designed and tested by varying geometry and operating conditions. In addition, air-cooling heat exchangers were tested to provide performance data for the comparison with the liquid-cooling heat exchangers. The liquid-cooling heat exchangers had twelve rectangular channels with different flow paths of 1, 2, and 12. Silicon rubber heaters were used to control the heat load to the heat exchangers. Heat input ranged from 293 to 800W, and inlet temperatures of working fluid varied from 15 to $27^{\circ}C$. The heat transfer coefficients were strongly affected by flow conditions. All liquid-cooling heat exchangers showed higher cooling performance than the air-cooling heat exchanger. The heat exchanger with 2-paths could provide more controllability on the maximum temperature than the others.

나노유체를 이용한 열사이폰 히트싱크 (Development of Nanofluidic Thermosyphon Heat Sink)

  • 이석호;신동륜;임택규;이충구;박기호;이욱현
    • 설비공학논문집
    • /
    • 제18권10호
    • /
    • pp.826-834
    • /
    • 2006
  • A heat sink system using nanofluidic thermosyphon for electronics systems was studied. The experimental results indicate that a cooling capacity of up to 150 W at an overall temperature difference of $50^{\circ}C$ can be attainable. The heat sink design program also showed that a computer simulation can predict the most of the parameters involved. In the experimental study, the volume concentration of nano particles affect the system performance. Nanofluidic thermosyphon with 0.5% volume concentration showed the best performance. Nanofluid can increase CHF of the system compared with water as a working fluid. The current simulation results were close to the experimental results in acceptable range. The simulation study showed that the design program can be a good tool to predict the effects of various parameters involved in the optimum design of the heat sink.

Occupational Health: Meeting the Challenges of the Next 20 Years

  • Harrison, John;Dawson, Leonie
    • Safety and Health at Work
    • /
    • 제7권2호
    • /
    • pp.143-149
    • /
    • 2016
  • Background: The industrial revolution that took place in the United Kingdom (UK) between 1760 and 1830 led to profound social change. Occupational medicine was concerned with the diagnosis, treatment, and prevention of occupational diseases, that is, diseases directly caused by exposure to workplace hazards. A similar pattern of development has occurred globally. Methods: A review of relevant literature. Results: The international conceptualization and development of occupational health occurred during the 20th century. A new paradigm for occupational health has emerged that extends the classical focus on what might be termed "health risk management" that is, the focus on workplace hazards and risk to health to include the medical aspects of sickness absence and rehabilitation, the support and management of chronic noncommunicable diseases, and workplace health promotion. Conclusion: The future strategic direction for occupational health will be informed by a needs analysis and a consideration of where it should be positioned within future healthcare provision. What are the occupational health workforce implications of the vision for occupational health provision? New challenges and new ways of working will necessitate a review of the competence and capacity of the occupational health workforce, with implications for future workforce planning.

Recent Progress on Sodium Vanadium Fluorophosphates for High Voltage Sodium-Ion Battery Application

  • Yuvaraj, Subramanian;Oh, Woong;Yoon, Won-Sub
    • Journal of Electrochemical Science and Technology
    • /
    • 제10권1호
    • /
    • pp.1-13
    • /
    • 2019
  • Na-ion batteries are being considered as promising cost-effective energy storage devices for the future compared to Li-ion batteries owing to the crustal abundance of Na-ion. However, the large radius of the Na ion result in sluggish electrode kinetics that leads to poor electrochemical performance, which prohibits the use of these batteries in real time application. Therefore, identification and optimization of the anode, cathode, and electrolyte are essential for achieving high-performance Na-ion batteries. In this context, the current review discusses the suitable high-voltage cathode materials for Na-ion batteries. According to a recent research survey, sodium vanadium fluorophosphate (NVPF) compounds have been emphasized for use as a high-voltage Na-ion cathode material. Among the fluorophosphate groups, $Na_3V_2(PO_4)_2F_3$ exhibited the high theoretical capacity ($128mAh\;g^{-1}$) and working voltage (~3.9 V vs. $Na/Na^+$) compared to the other fluorophosphates and $Na_3V_2(PO_4)_3$. Here, we have also highlighted the classification of Fluorophosphates, NVPF composite with carbonaceous materials, the appropriate synthesis methods and how these methods can enhance the electrochemical performance. Finally, the recent developments in NVPF for the application in energy storage devices and its outlook are summarized.