• Title/Summary/Keyword: Working Load

Search Result 727, Processing Time 0.025 seconds

A Study on the Stability of Foundation for Piers of WoljungGyo Bridge Built in Ancient Silla (신라시대 교량 월정교 교각기초의 복원안정성 연구)

  • Lee, Kwang-Wu;Hong, Gigwon;You, Seung-Kyong
    • Journal of the Korean Geosynthetics Society
    • /
    • v.18 no.4
    • /
    • pp.273-286
    • /
    • 2019
  • A derelict bridge called WoljungGyo was restored in Gyeongju, the capital city of ancient Silla. WoljungGyo was originally built in 760AD, and later rebuilt in 1280AD during the Goryeo Kingdom. The bridge lasted in working condition for at least 520 years. The bridge was uncovered to the remains of both abutments and four piers, with only one or two steps remaining. One of the foundation for piers showed evidence of partial settlement. The cause of the partial settlement is important for the successful restoration of the bridge so that an extensive investigation was carried out, which includes layer stratification by boring, 2-D stiffness profiling by surface-wave tests, and large scaled-plate load test for evaluating capacity. In addition to the field studies in the Woljunggyo bridge, 3-D finite element analysis was also conducted. Based on the results of the site investigation and the numerical analysis, it was concluded that the further ground improvement to build the piers was not necessary so that the gravels were placed and leveled underneath the existing pier stones to compensate partial settlement before the restoration.

Structural Design And Analysis of Haeundae Doosan We've The Zenith (해운대 두산 위브 더 제니스 구조설계)

  • Park, Ki-Hong;Park, Suk-Jin
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2008.11a
    • /
    • pp.93-98
    • /
    • 2008
  • Haeundae Doosan We've The Zenith project is adjacent to Suyoung-bay, now it is in the process of excavation and foundation work. The main use of the tower is residence which height is 300m and 80 floor, the highest residential reinforced concrete building through the Orient. It is comprised of 3 high- rised buildings and 1 low-rised building, the basement is 230m wide and 200m length sized mass structure. The lateral resistance system is acted effectively against the lateral load and satisfactorily against the wind vibration by the 4 direction extension of the center core wall($700{\sim}800mm$ thickness) and reinforced concrete column set around the slab. Flat-plate slab system(250mm thickness) is adjusted for the slab system and it enables effective work process and shortening the working term by minimizing the ceiling height and not needing to install perimeter beam and drop panel. The strength and serviceability of the structure is able to be monitored and estimated constantly through the health monitoring system during the construction and after the construction.

  • PDF

A Study on Measures to Improve Smoke Control Performance in Case of Fire in a Clean room as an LCD Manufacturing Process (LCD 제조공정 클린룸의 화재시 CFD를 이용한 제연성능 개선대책에 관한 연구)

  • Son, Bong-Sei;Jang, Chan-Hee
    • Fire Science and Engineering
    • /
    • v.26 no.5
    • /
    • pp.41-47
    • /
    • 2012
  • As a core process in the manufacture of state-of-the-art industrial technologies such as semiconductor and LCD, a clean room is the most important process which can affect the performance and quality of products drastically. Nevertheless, scientific research on comprehensive safety measures from a fire protection standpoint is not being carried out in Korea. This study aims to derive measures to improve smoke control systems by identifying performance and problems of smoke systems installed in clean rooms as an LCD manufacturing process and analyzing fire and evacuation simulations considering several scenarios. As a result of analysis of fires and smoke in a clean roomas an LCD manufacturing process, it is found to be necessary to stop air handling units through interlocking in case of a fire and exhaust smoke out of the room through the top of FAB in consideration of buoyancy of smoke. It is also found to be necessary to install quick response sprinkler heads and accessories to accelerate the response time, because the heat-accumulating performance of sprinkler heads decreases in this application. Despite its low density of dwelling due to the automation process, clean room is characterized by an array of complex production equipment and working environment requiring dustproof clothes, which makes it difficult to acquire evacuation safety performance. Thus, thorough control of danger factors in processes and periodic education and training are required. It is also necessary to establish a level of domestic technologies equivalent to the level of standards of advanced countries in fire protection.

Understanding the Experience of Visual Change Detection Based on the Experience of a Sensory Conflict Evoked by a Binocular Rivalry (양안경합의 감각적 상충 경험에 기초한 시각적 변화탐지 경험에 대한 이해)

  • Shin, Youngseon;Hyun, Joo-Seok
    • Science of Emotion and Sensibility
    • /
    • v.16 no.3
    • /
    • pp.341-350
    • /
    • 2013
  • The present study aimed to understand the sensory characteristic of change detection by comparing the experience of detecting a salient visual change against the experience of detecting a sensory conflict evoked by a binocular mismatch. In Experiment 1, we used the change detection task where 2, 4, or 6 items were short-term remembered in visual working memory and were compared with following test items. The half of change-present trials were manipulated to elicit a binocular rivalry on the test item with the change by way of monocular inputs across the eyes. The results showed that change detection accuracy without the rivalry manipulation declined evidently as the display setsize increased whereas no such setsize effect was observed with the rivalry manipulation. Experiment 2 tested search efficiency for the search array where the target was designated as an item with the rivalry manipulation, and found the search was very efficient regardless of the rivalry manipulation. The results of Experiment 1 and 2 showed that when the given memory load varies, the experience of detecting a salient visual change become similar to the experience of detecting a sensory conflict by a binocular rivalry.

  • PDF

Operatonal characteristics of the PLS linac vacuum system (PLS 선형가속기 진공계의 운전특성)

  • 김임경;박용정;김경렬;남궁원
    • Journal of the Korean Vacuum Society
    • /
    • v.5 no.4
    • /
    • pp.269-277
    • /
    • 1996
  • The vacuum systems of PLS linac provides average pressure of $2.6\times 10^{-6}$Pa under high power microwave of 54 MW peak with 4.1 $\mu \textrm s$ pulse width and 10 Hz repetition rates. The base pressure of system is$2.4\times 10^{-6}$Pa with 45$^{\circ}C$ cooling water. The outgassing rate of the system is decreased from $3.0\times 10^{-11}Torr-l/sec-\textrm{cm}^2$ at the initial stage after installation to $1\times 10^{-12}Torr-l/sec-\textrm{cm}^2$ at present. Total accumulated microwave energy dose is about 140 GJ per module. All ion pumps are working under saturated regime and effective pumping speeds of 60 I/s, 230 I/s ion pumps are 45 I/s, 65 I/s, 140 I/s under the operating range. Main problems occurred in recent year are troubles of ion pump controller and vacuum gauge controller, vacuum leak of energy doubler window and electron gun ceramic, and water leak in the dummy load of acceleraing columns. Total of 41 troubles with 140. 8 hours down time give good system availability of 98%. Down time can be reduced by high power waveguide valves and water dummy loads under development, and then availability is expected to be increased up to 99.5%.

  • PDF

Clinical Experience of Continuous Epidural Analgesia Using Baxter $Infusor^{(R)}$ (Baxter $Infusor^{(R)}$를 이용한 경막외 진통제 지속 주입)

  • Bae, Sang-Chull;Lee, Jang-Won;Kim, Ill-Ho;Song, Hoo-Bin;Park, Wook;Kim, Sung-Yell
    • The Korean Journal of Pain
    • /
    • v.4 no.2
    • /
    • pp.127-132
    • /
    • 1991
  • Recently a non-electronic, disposable and portable infusor(Baxter infusor with patient control module, Baxter health care Co., Deerfield IL 60015 USA: BI $\bar{c}$ PCM) has been developed that will deliver both a continuous drug infusion as well as allow the patient to deliver extra doses of medication on a demand basis under predetermined limitation of analgesics. Patients may also not require as high analgesic dose rate to control pain when the acceptable and tolerable level of pain relief can be maintained by this device. From April l99l, we have used a total l93 units of BI $\bar{c}$ PCM. These units consisting of two components which one made by a balloon reservoir(capacity 65 ml, flow rate 0.5 ml/hr) to store medication and to regulate the pump power(490 torr), and another two PCMs to regulate additional analgesic administration by patients demand at intervals of 1S minutes and 60 minutes. The dose administered to the patient can be varied by changing the concentration of the infusate within the balloon reservoir. These devices were utilized for the pain control of 44 patients. These patients were divided into two groups. Twenty seven cases had cancer pain and 17 cases had non-cancer pain. The Touhy needle(No. l8 G.) tip was inserted into the epidural space and was used to guide the catheter to the spinal nerve level corresponding to the most painful area. The device was connected to the opposite site of the catheter tip and was filled with 60 ml of mixture solution such as 0.5% bupivacaine 15 ml, morphine HCl 10 mg, trazodone 10 ml, Tridol 3 ml and normal saline 31 ml were administed as the initial dose. When the initial dose was less effective, the next dose could be varied by increasing the concentration of bupivacaine, by adding more morphine (5~10 mg), and by reducing the volume of normal saline. Using these modules of drug self administration, we experienced the following: 1) Improvement of patient's self titration of analgesic requirement was provided. 2) The patients anxiety with pain recurrence resulting from delays in administering pain control medication was decreased significantly. 3) The working load accompanying with the single bolus injection as the usual method was reduced remarkably. 4) There was urinary retention in 5 cases and pruritus in 4 eases which developed as side effects but respiratory depression and vomiting was not encountered in a single case.

  • PDF

Musculoskeletal Workload Evaluation in Physical Therapist (물리치료사의 근골격계 부담작업 유해요인 조사)

  • Sung, Youn-Bum;Seo, Hyung-Seok;Lee, Jung-Ho;Park, Young-Han
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.9
    • /
    • pp.3999-4008
    • /
    • 2012
  • This study investigated the symptoms of work-related musculoskeletal disorder(WMSDs) for physical therapists who have different work duties. We analyzed the symptoms in the musculoskeletal system and the degree of work-harmfulness by the survey of the symptom in the musculoskeletal system and rapid upper limb assessment(RULA) for pain control group(n=56), adult exercise group(n=53), and pediatric exercise group(n=22). As a result, 69.6% of the pain control group, 84.9% of the adult exercise group, 81.8% of the pediatric exercise group show the observable symptom. The adult exercise group has the biggest work load per hour in the final wrist & arm score of the ergonomic risk assessment using RULA. The action level of the pain control group is $3.0{\pm}0.9$; the Action Level of adult exercise group is $3.3{\pm}0.6$; the Action Level of the pediatric exercise group is $3.2{\pm}0.8$, and so it is shown that the adult exercise group has a problem of working posture. It is considered that devices and education system for preventing from WMSDs should come into wide use.

A Study on Principle for Use of Multimedia in order to have Effective Communication in Information Design (정보디자인에서 효과적 커뮤니케이션을 위한 멀티미디어 사용원리에 관한 연구)

  • Lee, Il-Soon
    • Cartoon and Animation Studies
    • /
    • s.13
    • /
    • pp.255-267
    • /
    • 2008
  • Recently in the field of information design use of multimedia Including animation has been rapidly increased. And its application is expanding in the field of design nevertheless relevant research in this field is scant. In particular research on which characteristics contribute to improvement for effect of information communication is negligible. Until now designers' interest was mainly focused on visual perfection of screen such as diversity and originality. Actually the aspect of recognition of design was mostly overlooked. But considering ultimate purpose of Information design is accurate communication of information thus there should be more endeavor for research on man's visual recognitive faculty and memory in order to Improve power of communication of information for the purpose of reducing confusion of user before its originality and diversity. For this reason this author in this treatise attempted to examine possible impact of multimedia in information design on recognition of user and communication based on theory of effectiveness of media and also attempted to identify how maximize its effect under different circumstances. Theories on effectiveness of media can be summed up as that well- advanced information of multimedia should be analysed from diverse standpoints on relevancy to tasks and recognitive relevancy rather than its simplification from the standpoint of richness of media. For optimal interface design unnecessary recognitive load should be eliminated and information should be structured by laking maximum advantage of working memory of limited quantity. Also there will be need for selection of proper media and suggestion of expressive method to enable building accurate and successful mental image. In this treatise this author attempted to contribute to designer's decision making in future through examining theories on effectiveness of media in connection with the question of which information technology should be used in order to heighten effect of information communication appropriate to information design.

  • PDF

A Study on the Rate of Breast-feeding Practice by Education and Continuous Telephone Follow-up (모유수유 교육과 분만 후 지속적인 전화상담에 따른 모유수유 실천률 조사)

  • Yoo, Eun-Kwang;Kim, Myoung-Hee;Seo, Won-Shim
    • Women's Health Nursing
    • /
    • v.8 no.3
    • /
    • pp.424-434
    • /
    • 2002
  • Background & purpose Since the 1970's the rate of breast-feeding has decreased significantly. The Korean National Institute of Health reported that the rate of breastfeeding was 68.9% in 1982 and 14.1% in 1997. There are many influencing factors including: the lack of education and information on breast feeding, lack of faith in breast feeding, increment of the rate of working, lack of encouragement by supporters in difficult situations, and nurses' low level of knowledge about breast feeding. Such a lack of knowledge and support of breast-feeding at home by family members create another dilemma to the problem of breast-feeding. If problems arise and family members are unable to provide assistance due to the deficiency of knowledge, mothers show a tendency to abandon breast-feeding. The purpose of this research is to find out the rate of breast-feeding practice by time sequence of 1 week, 6 weeks and 12 weeks after birth and influencing factors on breast-feeding practice centered on the postpartal women who were 3discharged from one hospital, which is located in Seoul and provides simple breast-feeding education and continuous postnatal telephone consultation. Methodology The subjects of this research were 54 women who gave birth in a hospital located in Seoul from 1 March 2000 to 31 April 2000. After birth the subjects were educated individually about breast-feeding and telephone consultations were conducted. On the 1st week, 6th week, and 12th week, the subjects were surveyed about their breast-feeding practice rates and methods by telephone. Results 1) Complete breast-feeding rate: Within one week after birth, the subjects showed 64.2% complete breast-feeding rate. Within 6 weeks, 39.6%, and 12 weeks, 34.1%. 2) Partial breast-feeding rate: Within one week after birth, the subjects showed 32.1% partial breast-feeding rate. Within 6 weeks, 39.6%, and 12 weeks 15.1%. 3) Complete bottle-feeding rate Within one week after birth, the subjects showed 1.9% complete bottle-feeding rate. Within 6 weeks of giving birth 15.1%, and 12 weeks 17.0%. These results show that individual education about breast-feeding and continuous postnatal telephone consultation influenced on the practice of breast-feeding. On considering the reality of the hospital situation in which nurses could not operate education program due to the work-load, it is necessary to find out selectively those mothers who are unable to breast feed and provide education individually and continuous support by telephone follow up. Futhermore, the active role of lactation nurse specialist and their efficient management of breast-feeding for the successful practice is required.

  • PDF

Optimization study on roof break direction of gob-side entry retaining by roof break and filling in thick-layer soft rock layer

  • Yang, Dang-Wei;Ma, Zhan-Guo;Qi, Fu-Zhou;Gong, Peng;Liu, Dao-Ping;Zhao, Guo-Zhen;Zhang, Ray Ruichong
    • Geomechanics and Engineering
    • /
    • v.13 no.2
    • /
    • pp.195-215
    • /
    • 2017
  • This paper proposes gob-side entry retaining by roof break and filling in thick-layer soft rock conditions based on the thick-layer soft rock roof strata migration law and the demand for non-pillar gob-side entry retaining projects. The functional expressions of main roof subsidence are derived for three break roof direction conditions: lateral deflection toward the roadway, lateral deflection toward the gob and vertically to the roof. These are derived according to the load-bearing boundary conditions of the main roadway roof stratum. It is concluded that the break roof angle is an important factor influencing the stability of gob-side entry retaining surrounding rock. This paper studies the stress distribution characteristics and plastic damage scope of gob-side entry retaining integrated coal seams, as well as the roof strata migration law and the supporting stability of caving structure filled on the break roof layer at the break roof angles of $-5^{\circ}$, $0^{\circ}$, $5^{\circ}$, $10^{\circ}$ and $15^{\circ}$ are studied. The simulation results of numerical analysis indicate that, the stress concentration and plastic damage scope to the sides of gob-side entry retaining integrated coal at the break roof angle of $5^{\circ}$ are reduced and shearing stress concentration of the caving filling body has been eliminated. The disturbance of coal mining to the roadway roof and loss of carrying capacity are mitigated. Field tests have been carried out on air-return roadway 5203 with the break roof angle of $5^{\circ}$. The monitoring indicates that the break roof filling section and compaction section are located at 0-45 m and 45-75 m behind the working face, respectively. The section from 75-100 m tends to be stable.