• Title/Summary/Keyword: Work noise

Search Result 1,349, Processing Time 0.037 seconds

자동차 엔진 냉각홴의 공력 소음 예측에 관한 연구 (Aerodynamic Noise Prediction of Automobile Engine Cooling Fan Noise)

  • 이정한;조경석;선효성;신형기;이수갑
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 1998년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.115-120
    • /
    • 1998
  • Aerodynamic noise generated by automobile cooling fan is investigated. Automobile cooling fans radiate both discrete frequency noise as well as broadband noise. In the present work, the former is considered through free-wake panel method coupled with acoustic analogy fully considering the retarded time variation on the blade surface, while the latter is taken into account by three well-established broadband noise components. Experiments were performed to supplement necessary inputs as well as to provide the final comparison with the predicted noise spectrum. The predicted noise levels at blade passing frequencies agree well with the experimental data for the first few harmonics. Although the predicted broadband noise levels at higher frequencies fall below the experimental data due to the fundamental shortcomings of the utilized formulations, the analysis offers a detailed physical understanding of the fan noise generation processes.

  • PDF

항타공법에 의한 발생 소음 특성 분석 및 축소 모형 실험을 이용한 저소음 말뚝 캡의 설계 (Investigation on Noise Characteristics of Pile Driving Operation and Design of a Low-noise Pile Cap Based on the Scale Model Experiment)

  • 이종화;이정권;이기홍;정승창
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 춘계학술대회논문집
    • /
    • pp.445-448
    • /
    • 2001
  • Noise radiated from pile driving operation is one of major sources of community noise pollution and thus its operation method is strictly restricted by regulations. Although the drilling method is now used been commonly used in urban areas because of its activity, the benefit of low noise decreases due to high working cost. In the present work, noise characteristics of pile driving operation are carried out. Based on the study result, a low-noise pile cap for driven piles is developed in order to satisfy both the noise level restriction and the economical efficiency. Effects of pile cap are investigated by a scale model experiment, which is focused on the variation of impact force and sound pressure level. The results show a good possibility of noise reduction by an appropriately designed pile cap.

  • PDF

디젤 엔진 지게차의 소음원별 기여도 분석과 실내소음 저감 (Noise Contribution Analysis and Noise reduction of a Diesel Engine Fork-lift Truck)

  • 이종규;조영호;김경환;박석태;김낙인
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.1473-1478
    • /
    • 2000
  • Severe fork-lift truck noise is annoying to an operator as well as one of the noise pollution elements. This paper presents the noise contribution analysis of a cabin type fork-lift truck to identify the major sources and its usage to reduce the interior noise level. The methodologies for this work are sound field analysis, sound intensity test, insertion loss test of duct system and etc. An effective method to suppress interior noise level of fork-lift truck and design guides are suggested.

  • PDF

청력보호를 위한 선박 기관실 및 선실소음의 조사(I) (An Investigation of the Noise in Ship Engine-Room and Cabins for Hearing Protection (I))

  • 유영훈
    • 동력기계공학회지
    • /
    • 제3권3호
    • /
    • pp.97-103
    • /
    • 1999
  • As the noise of ship engine room is too loud, the engineer who works in a ship engine-room has the trouble of hearing. In this paper deals the investigation of the noise of ship engine room and cabins with the internationally allowable noise exposure level and noise exposure time. Recently, the problem of engine-room noise is more serious because of shipowner wants to make small number and larger size of cylinder. Therefore, engineers work in a ship engine-room for a long time have the trouble of hearing when they are exposed the high noise level. In this study, two kinds of vessels were used to investigate the noise of engine room, engine-control room, bridge, offices and cabins. As criteria of sound levels, A-weighted sound pressure level and octave band pressure level were used.

  • PDF

SEA에 의한 회전 압축기의 소음 진동 해석 (Noise and Vibration Analysis of Rotary Compressor by SEA)

  • 황선웅;안병하;정의봉;김규환
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.964-968
    • /
    • 2003
  • Hermetic rotary compressor is one of the most Important components for air conditioning system since it has a great effect on both the performance and the noise and vibration of He system. Noise and vibration of rotary compressor is occurred due to gas pulsation during compression process and unbalanced dynamic force. In order to reduce noise and vibration. it is necessary to identify sources of noise and vibration and effectively control then. Many approaches have been tried to identify noise sources of compressor. However, compressor noise source identification has proven to be difficult since the characteristics of compressor noise are complicated due to the interaction of the compressor parts and gas pulsation. In this work, Statistical Energy Analysis has been used to trace the energy flow in the compressor and identify transmission paths from the noise source to the sound field.

  • PDF

경량전철 교량 상부구조의 열차주행에 대한 진동 및 소음 분석 (The Estimation of Structural-Borne Noise and Vibration of the Bridge under the Passage of the Light Rail Transit)

  • 여인호;정원석;김성춘;김성일
    • 한국철도학회논문집
    • /
    • 제10권1호
    • /
    • pp.22-28
    • /
    • 2007
  • During the passage of the train, the railway bridge undergoes vibration and noise. The noise of railway bridge can be occurred from various sources. The wheel-rail contact, noise from machinery parts, structural-borne noise, pantagraph noise and aerodynamic noise of the train work in combination. Running train is one of the most important factors for railway bridge vibration. The repeated forces with equidistant axles cause the magnification of dynamic responses which relates with maintenance of the track structure and structure-borne noises. The noise problem is one of the most important issues in services of light rail transit system which usually passes through towns. In the present study, The vibration and noise of the LRT bridge will be investigated with utilizing dynamics responses from moving train as input data for noise analysis.

석탄화력발전소 작업자의 소음과 온열 스트레스에 대한 노출 평가 (Evaluation of Occupational Exposure to Noise and Heat stress in Coal-fired Power Plants)

  • 권지운;장광명;김성호;김세동;장미연;노지원;박승현
    • 한국산업보건학회지
    • /
    • 제33권4호
    • /
    • pp.464-470
    • /
    • 2023
  • Objectives: This study evaluated occupational exposures to noise and heat stress during routine non-outage works in three coal-fired power plants in the Republic of Korea. Methods: The data were collected during the summer of 2020. Full shift noise exposure of 52 workers were measured using noise dosimeters. Heat stress of 16 worksites were measured for 70 minutes using wet-bulb globe temperature monitors. Results: The noise dosimetry results revealed time-weighted averages that ranged from 47.5 to 88.9 dBA. 2 out of 52 noise measurements exceeded 85 dBA. Based on the arithmetic mean, the coal service group showed the highest level at 80.2 dBA by job tasks. Noise exposures exceeding 85 dBA were measured in the coal service and plant operator group. Heat stress index measurements ranged from 20.3℃ to 37.2℃. 1 out of 9 indices measured in coal facilities and 4 out of 7 indices measured in boiler house exceeded 1 hour TWA during moderate work. Heat stress indices measured from boiler houses were significantly higher than those measured from coal equipment. Conclusions: The results show that overexposure to noise and heat stress may be encountered during routine non-outage work activities in coal-fired power plants. Appropriate actions should be taken to reduce future health outcome from occupational exposure to noise and heat stress in the industry.

다구찌 기법을 이용한 냉장고의 구조진동음 저감 방법에 관한 연구 (A Study on the Structure-borne Noise Reduction of Refrigerators Using Taguchi Method)

  • 손솔산;서재용;이부윤;김원진
    • 한국소음진동공학회논문집
    • /
    • 제20권5호
    • /
    • pp.470-476
    • /
    • 2010
  • In this work, the mechanism of structure-borne noise resulting from vibration of a compressor for a refrigerator is experimentally analyzed and an effective method is proposed to reduce the noise. Firstly, the emission noise, when the compressor is turned on and off, is measured and analyzed to identify the generation mechanism of structure-borne noise. And the acceleration on the outer wall of the refrigerator is also analyzed to identify the distribution of vibration. Secondly, an effective design method to reduce the noise is suggested by using the finite element analysis and Taguchi method. Consequently an optimal design of the refrigerator, which has lower noise, is obtained and then its performance and validity are verified through the analysis and test.

덤프트럭의 저주파 소음 특성 (Low Frequency Noise Characteristics of Dump Truck)

  • 정성수;전병수;신수현
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.1183-1186
    • /
    • 2007
  • The low frequency noise, including infra-sound is known to affect human physiology and psychology. Guidelines and measurement method of low frequency noise has been introduced in several countries in order to evaluate low frequency noise. In this work, low frequency noise characteristics of dump truck was investigated in terms of the noise level and spectrum. The interior sound pressure level of the dump truck was between 60 and 105 dB in the frequency range of $1{\sim}250$ Hz.

  • PDF

ISO 노면의 Pass-by-Noise Level 편차에 관한 연구 (The Study on the Variation of Pass-by-Noise level due to ISO Road)

  • 김기전;배철용;노국희
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.371-376
    • /
    • 2003
  • The objective of this paper is to compare the site-to-site variability of ISO 10844 pass-by-noise test sites. In order to investigate the site-to-site variance of test surfaces, European commercial tires are tested at seven different test sites. Three Korea test sites and four Europe test sites are selected.. The pass by noise test is executed according to a 2001/43/EC regulation. A]though the ISO surface has a very specific track composition, it does not reduce the variation of pass-by-noise measurements over the surface of test sites. This paper shows that the test results of pass-by-noise level are different depending on the test sites. The correlation obtained in this work is able to predict the pass by noise level for certain test site using the data measured from another test site. 17he prediction value is range with an error within 1dB(A).

  • PDF