• Title/Summary/Keyword: Work Zone Accident

Search Result 14, Processing Time 0.019 seconds

Human Error Analysis in a Permit to Work System: A Case Study in a Chemical Plant

  • Jahangiri, Mehdi;Hoboubi, Naser;Rostamabadi, Akbar;Keshavarzi, Sareh;Hosseini, Ali Akbar
    • Safety and Health at Work
    • /
    • v.7 no.1
    • /
    • pp.6-11
    • /
    • 2016
  • Background: A permit to work (PTW) is a formal written system to control certain types of work which are identified as potentially hazardous. However, human error in PTW processes can lead to an accident. Methods: This cross-sectional, descriptive study was conducted to estimate the probability of human errors in PTWprocesses in a chemical plant in Iran. In the first stage, through interviewing the personnel and studying the procedure in the plant, the PTW process was analyzed using the hierarchical task analysis technique. In doing so, PTWwas considered as a goal and detailed tasks to achieve the goal were analyzed. In the next step, the standardized plant analysis risk-human (SPAR-H) reliability analysis method was applied for estimation of human error probability. Results: The mean probability of human error in the PTW system was estimated to be 0.11. The highest probability of human error in the PTW process was related to flammable gas testing (50.7%). Conclusion: The SPAR-H method applied in this study could analyze and quantify the potential human errors and extract the required measures for reducing the error probabilities in PTW system. Some suggestions to reduce the likelihood of errors, especially in the field of modifying the performance shaping factors and dependencies among tasks are provided.

Developing Risk Analysis Methods for Realtime RiskMAP System (실시간 위험지도 시스템을 위한 위험분석 기법 개발)

  • Park, Sang Bae;Lee, Chang Jun;Joo, Yu Kyoung;Oh, Jeong Seok
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.3
    • /
    • pp.27-32
    • /
    • 2020
  • For preventing accident, the risk analysis about gas facilities has been more important since many gas facilities be superannuated. Especially, deriving and simulating risk is very important for preventing and corresponding accidents by means of specific analysis method in complex gas facilities. However, many studies have been not enough not yet in order to derive and simulate risk considering various situations. This paper aims to propose deriving and analyzing risk method around limited area of complex gas facilities. Our study proposes total risk analysis that is composed four methods with individual point of view. The risk analysis system based on RiskMAP immediately informs users changes of e risk in zones according to the status, work and surrounding conditions of the facility. The proposed methods in this research are implemented as software algorithm and applied to risk analysis system using RiskMAP in conjunction with IoT and GPS.

GIS Mapping of Coastal Pollution Induced by Hebei Spirit Oil Spill (허베이 스피리트호 유류유출 사고에 따른 해안오염 GIS 지도 제작 연구)

  • Park, Jae-Moon;Choi, Hyun-Woo;Yoon, Hong-Joo
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.12 no.3
    • /
    • pp.164-178
    • /
    • 2009
  • This study was aimed to make GIS oiling thematic maps and analyze temporal oiling variation patterns for two months after 'Hebei Spirit' oil spill accident in December 7, 2007 using GIS and oiling status surveyed data. As a basic work for making of oiling thematic maps, geometric corrections were performed with IKONOS images using ground control points data. These corrected images were used to make detailed coastline from digital charts, and then spatial unit of coastline were defined using classified coastline types. And to know the representative parameters which reflect oiling situation, relationship between oiling status parameters extracted from four times oiling assessment reports and total petroleum hydrocarbons (TPHs) data (December 2007 and January 2008) monitored by Korea Ocean Research and Development Institute (KORDI). Using these representative oiling status parameters pollution value were calculated, and they were keyed into spatial unit of coastline as attributive value. GIS oiling status thematic maps made with coastline containing pollution value showed the initial two month's situations somewhat well. Also, to analyze temporal variation pattern of coastline types, about 13.4km length coastline around Malripo beach was defined as detailed study area where is the common spatial zone surveyed oiling status by each organizations. Based on this study results, it could be possible to provide oiling status maps quickly and to support decision making for oiling control action and scientific pollution monitoring.

  • PDF

Estimation of fire Experiment Prediction by Utility Tunnels Fire Experiment and Simulation (지하공동구 화재 실험 및 시뮬레이션에 의한 화재 설칠 예측 평가)

  • 윤명오;고재선;박형주;박성은
    • Fire Science and Engineering
    • /
    • v.15 no.1
    • /
    • pp.23-33
    • /
    • 2001
  • The utility tunnels are the important facility as a mainstay of country because of the latest communication developments. However, the utilities tunnel is difficult to deal with in case of a fire accident. When a cable burns, the black smoke containing poisonous gas will be reduced. This black smoke goes into the tunnel, and makes it difficult to extinguish the fire. Therefore, when there was a fire in the utility tunnel, the central nerves of the country had been paralyzed, such as property damage, communication interruption, in addition to inconvenience for people. This paper is based on the fire occurred in the past, and reenacting the fire by making the real utilities tunnel model. The aim of this paper is the scientific analysis of the character image of the fire, and the verification of each fire protection system whether it works well after process of setting up a fire protection system in the utilities tunnel at a constant temperature. The fire experiment was equipped with the linear heat detector, the fire door, the connection water spray system and the ventilation system in the utilities tunnel. Fixed portion of an electric power supply cable was coated with a fire retardant coating, and a heating tube was covered with a fireproof. The result showed that the highest temperature was $932^{\circ}c$ and the linear heat detector was working at the constant temperature, and it pointed at the place of the fire on the receiving board, and Fixed portion of the electric power supply cable coated with the fire retardant coating did not work as the fireproof. The heating tube was covered with the fireproof about 30 minutes.

  • PDF