• Title/Summary/Keyword: Work Environment Measurement

Search Result 321, Processing Time 0.031 seconds

Development of a Web Platform System for Worker Protection using EEG Emotion Classification (뇌파 기반 감정 분류를 활용한 작업자 보호를 위한 웹 플랫폼 시스템 개발)

  • Ssang-Hee Seo
    • Journal of Internet of Things and Convergence
    • /
    • v.9 no.6
    • /
    • pp.37-44
    • /
    • 2023
  • As a primary technology of Industry 4.0, human-robot collaboration (HRC) requires additional measures to ensure worker safety. Previous studies on avoiding collisions between collaborative robots and workers mainly detect collisions based on sensors and cameras attached to the robot. This method requires complex algorithms to continuously track robots, people, and objects and has the disadvantage of not being able to respond quickly to changes in the work environment. The present study was conducted to implement a web-based platform that manages collaborative robots by recognizing the emotions of workers - specifically their perception of danger - in the collaborative process. To this end, we developed a web-based application that collects and stores emotion-related brain waves via a wearable device; a deep-learning model that extracts and classifies the characteristics of neutral, positive, and negative emotions; and an Internet-of-things (IoT) interface program that controls motor operation according to classified emotions. We conducted a comparative analysis of our system's performance using a public open dataset and a dataset collected through actual measurement, achieving validation accuracies of 96.8% and 70.7%, respectively.

Impact of Indoor Green in Rest Space on Fatigue Recovery Among Manufacturing Workers (휴게공간에서의 식물 도입이 생산직 근로자의 피로 회복에 미치는 효과)

  • ChoHye Youn;LeeBom Chung;Minji Kang;Juyoung Lee
    • Journal of Environmental Science International
    • /
    • v.33 no.3
    • /
    • pp.217-226
    • /
    • 2024
  • Manufacturing workers face increased fatigue and stress due to environmental factors in workplace such as noise and vibration. Addressing this issue requires creating conducive rest spaces; however, the existing conditions of rest spaces in manufacturing workplace are subpar and lack sufficient scholarly evidence. This study investigated the effect of nature-based rest spaces on the physical and emotional recovery from fatigue on manufacturing workers. Three manufacturing complexes with nature-friendly rest spaces were selected, and 63 manufacturing workers participated in the study. The measurement tools included the Multidimensional Fatigue Scale (MFS) for fatigue levels, physiological indicators (blood pressure and heart rate), and emotional indicators (Zuckerman Inventory of Personal Reaction Scale; ZIPERS, Perceived Restorativeness Scale; PRS, Profile of Mood States; POMS and State-Trait Anxiety Inventory; STAI). The study compared recovery levels during a 7-minute rest between a space without plants and a space with natural elements. The results indicated a significant reduction in systolic and diastolic blood pressure of participants in green rest spaces compared with those in conventional rest spaces. Regarding fatigue levels, green rest spaces showed a decrease in systolic blood pressure in the middle-fatigue and high-fatigue groups. Positive feelings increased in green spaces, whereas negative emotions decreased, suggesting that short breaks in nature-friendly environments effectively promote workers' physical and emotional recovery. Furthermore, this study emphasizes the importance of green space in various work environments to promote well-being in workers.

Assessment of dust exposure and personal protective equipment among dental technicians (치과기공사의 분진노출 수준 및 개인보호구 착용 실태 - 대구지역을 중심으로 -)

  • Park, Soo-Chul;Jeon, Man-Joong;SaKong, Joon
    • Journal of Technologic Dentistry
    • /
    • v.33 no.1
    • /
    • pp.93-102
    • /
    • 2011
  • Purpose: The study aimed to evaluate working environment for dental technician by measuring dust level, ventilation conditions and the use of personal protective equipment and to provide basic information required to improve working environment and develop health education programs for dental technician. Methods: A total of 240 dental technician who are registered with the Daegu Association of Dental technician and working at 34 dental laboratories participated in the study. And the dust level was measured at 21 different spots in 16 dental laboratories out of 34. Results: Of 34 dental laboratories, 31 (91.2%) were equipped with a ventilator, but the remaining 3 (8.8%) did not have a ventilator. By the number of ventilator, 1 to 3 ventilators were found in 22 dental laboratories (71.0%), 4 to 6 ventilators were in 7 laboratories (22.5%) and more than 7 ventilators in 2 laboratories(6.5%). According to the frequence of changing filters in dust collector, 20 dental laboratories (58.9%) changed filters every four weeks, 10 laboratories (29.4%) changed them every six weeks and 4 laboratories (11.7%) changed them every eight weeks. Of total respondents, 114 (61.3%) said they wore a mask all the time while working, 56 (29.6%) said they frequently wore a mask, 19 (10.1%) said they did not wear a mask. As for the type of masks, 159 (84.1%) used a disposable mask, 25 (13.2%) used a cotton mask and 5 (2.7%) used an anti-dust mask. For dust sat on their outfits while working, 102 (54.0%) shook their uniforms inside workplace to keep dust off the uniforms, 64 (33.9%) did not anything until they wash their uniforms and 23 (12.1%) shook their uniforms outside workplace to keep dust off the uniforms. Of total respondents, 182 (96.3%) had a particle in their eyes while carrying out grinding work. Based on the measurement of floating dust at workplace, 3 dental laboratories showed dust concentration exceeding the minimum level of 10 mg/$m^3$ allowed under the permit for environment. Of those, 1 laboratory had the dust concentration that was more than 1.5 times higher than the minimum level. Dust concentration was higher in laboratories that used a dust collector with 0.5 horse power and changed filters more than 3 weeks ago. Dust comprised of nickel (more than 70%), chrome (9%) and others. The mean chrome concentration was more than twice higher than the minimum permissible level of 0.5 mg/$m^3$. There were two laboratories that showed chrome concentration exceeding the level of 0.4 mg/$m^3$. Like dust concentration, chrome level was higher in laboratories that used a dust collector with 0.5 horse power and changed filters more than 3 weeks ago. There were six laboratories that had nickel concentration exceeding the minimum permissible level of 1 mg/$m^3$. Of those, one laboratory had nickel concentration that was more than three times higher than the minimum permissible level. Nickel concentration was also higher in laboratories that used a dust collector with 0.5 horse power and changed filters more than 3 weeks ago. Conclusion: It is not likely that heavy metal concentrations found in the study constitute respiratory dust. It is however necessary for health of dental technician to apply the Industrial Safety and Healthy Law to dental laboratories and make recommendations for the use of personal protective equipment, installation of a proper number of ventilators, more frequent change of filters in dust collector and improved ventilation for polishing work. At the same time, dental technician need education on how to use personal protective equipment and how to efficiently remove dust from their uniforms.

Time Measurement Study of Certified Clinical Dietitians from Tertiary Hospital in Seoul and Gyeonggi-do (병원 임상영양사의 업무별 소요시간 분석: 서울 및 경기 일부의 상급종합병원을 중심으로)

  • Um, Mi Hyang;Park, Yoo Kyung;Lee, Song Mi;Cha, Jin A;Lee, Eun;Lyu, Eun Soon
    • Journal of the Korean Dietetic Association
    • /
    • v.21 no.2
    • /
    • pp.123-139
    • /
    • 2015
  • The objective of this study was to document how clinical dietitians working at tertiary hospitals spend their time based on several categories of activities using a time measurement study. The questionnaires were distributed to 14 tertiary hospitals, and dietitians answered by classifying their work activities into several categories such as general care, indirect care, direct care, outpatient care, and food service management. A total of 129 clinical dietitians replied and their answers were analyzed according to the categories of activities. The times spent on the categories are as follows: general care (76.7 mins/day, 14%), indirect care (228.4 mins/day, 35%), direct care (120.1 mins/day, 22%), outpatient care (61.5 mins/day, 11%), and food service management (99.0 mins/day, 18%). The total working hours for dietitians was 590.0 mins, which exceeds the standard working hours of 540.0 mins (9 hrs) a day. From this study, we found that clinical dietitians spent very limited time on direct care. Times spent on activities were different according to type of employment and food service. Internship dietitians spent their more time on general care (P<0.001) while irregular dietitians spent more time on outpatient care (P<0.05). In contracted managed food service hospitals, clinical dietitians spent significantly less time on food service management (P<0.001). Regardless of doctors' order and consultation fees, clinical dietitians performed more than 95 percent of free consultation to patients. Entry-level knowledge and skills of dietitians working at hospitals are very important for quality service, but it is equally important to create an administrative and social environment that encourages clinical dietitian to spend more time on direct patient care.

Dose Assessment of the Eye of the Operator in the Field of Angiography and Interventional Radiography (혈관조영 및 중재적 시술 분야 내 종사자의 눈에 대한 선량평가)

  • Kim, Jung-hoon;Cho, Yong-In
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.2
    • /
    • pp.209-216
    • /
    • 2018
  • In the field of angiography and interventional radiology, it is said that the risk of radiation exposure to the eyes is high due to the characteristics of work, but currently divided dose assessment and management are not carried out in reality. Therefore, in this study, in order to evaluate the dose of the operator in the surgical environment and to analyze the shields, firstly, we selected the point where the operator is mainly located, evaluated the exposure dose of the eye after attaching the pocket dosimeter to the lateral angle point of the head and neck phantom, and evaluate shielding effect when wearing lead glasses that is currently commercialized. Secondly, we evaluated the tendency of the exposure dose of the eye and the shielding effect through simulation in the same geometric structure as the actual measurement. As a result, in the case of measurement using a dosimeter, the cumulative dose increased with the increase of the fluoroscopic time, and the tendency was different according to the position of the operator. Simulation results show that the dose distribution of the eye lens in the mathematical phantom is about 1.1 ~ 1.3 times higher than that of the cornea. Also, The protective effect of the lead glasses showed a shielding effect of at least 3.7 ~ 21.4% in each eye.

A Measurement of Exposure Dose for Patient Transporter (환자 이송원의 피폭선량 측정)

  • Song, Chaerim;Lee, Wanghui;Ahn, Sungmin
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.3
    • /
    • pp.433-438
    • /
    • 2019
  • The medical institutions use radiation generating devices and radioactive isotopes to diagnose and treat patients. The patient transporter performs work in an environment that is more likely to be exposed to radiation when compared with the general public, such as inevitably entering the radiation management area for patient transfer, or transferring the isotope-administered patient at a short distance. For this reason, we conducted a study to determine the degree of exposure of the patient transporter. The 12 patient transporters working at Incheon A General Hospital are eligible. From April 1, 2019 to April 30, 2019, the dosimeter was used in the chest for one month and the accumulated dose was measured. The dosimeter used was a Optically Stimulated Luminescence Dosimetry (OSLD) and the dose reading was OSLD Microstar Reading System. As a result of cumulative dose measurement for one month, the average of the deep dose was 0.13 mSv and the surface dose was 0.13 mSv, and the cumulative dose for one month was multiplied by 12 to estimate the cumulative dose expectation As a result, the average of the deep dose and the surface dose were 1.52 mSv and 1.51 mSv, respectively. It is necessary to classify the patient transporter as a frequent visitor in order to measure and manage the exposure dose, increase the knowledge of protection against radiation through education and training, and prevent radiation trouble through medical examination.

Comparison of acoustics performance measurement and evaluation standard of office space and office acoustics criteria of European countries (사무공간의 음향성능 측정, 평가 방법의 표준화와 유럽 국가들의 음향성능 기준 비교)

  • Jeong-Ho Jeong
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.2
    • /
    • pp.133-142
    • /
    • 2023
  • The office environment is changing according to work types, Information Technology (IT) advancements, and the Coronavirus disease (COVID)-19 situation. In order for office space users to perform their tasks comfortably and efficiently, it is necessary to secure individual privacy as well as easy communication among members. In Korea, the demand for improving the acoustic performance of office spaces is also increasing, but the related performance criteria and guidelines have not been established. In this study, standardization of office space acoustic performance measurement and evaluation methods and European countries' acoustic performance criteria were compared and reviewed. It is proposed to comprehensively review international standardization trends and acoustic performance standards in each country and to establish and utilize criteria for evaluating the acoustic performance and satisfaction of office spaces in Korea through our survey. Considering the international standardization direction and compatibility with communication and Public Address (PA) systems, it is appropriate to establish criteria using the speech transmission index or Speech Transmission Index (STI) application index. This criterion will be highly utilizable and compatible. In addition, since the office furniture industry is interested in improving the acoustic performance of office space, it is necessary to establish a labelling system for speech level reduction of office furniture.

The Effects of Work and Life Satisfaction on the Turnover Intention, and the Moderating Effects of Employment Type (일과 생활만족도가 이직의도에 미치는 영향과 고용형태의 조절효과 분석)

  • Lee, Soo-Ah;Kang, Soon-Hie
    • The Journal of the Korea Contents Association
    • /
    • v.18 no.5
    • /
    • pp.600-611
    • /
    • 2018
  • This study analyzed the effects of wage workers' job satisfaction, life satisfaction on turnover intention, and moderating effect of employment type after the global financial crisis using Korean Labor and Income Panel Study data. As a result, we found that the higher the job satisfaction is, the lower the turnover intention. However, the higher the job satisfaction and life satisfaction are, the higher the turnover intention. This is because the more satisfied with the job environment, the higher the tendency to seek better job opportunities, or the change in occupational value that favored free work. The higher the age, the higher the educational level, and the regular jobs are, the turnover intention decreased. In addition, the interaction terms of job satisfaction, job environmental satisfaction, life satisfaction, and regular employment all showed a moderating effect of employment type. However, since the results of the relationship between job satisfaction, job environmental satisfaction, life satisfaction and turnover intention, and the moderating effect may be due to limitations of measurement variables, further study is needed.

Estimating Benzene Exposure Level over Time and by Industry Type through a Review of Literature on Korea

  • Park, Donguk;Choi, Sangjun;Ha, Kwonchul;Jung, Hyejung;Yoon, Chungsik;Koh, Dong-Hee;Ryu, Seunghun;Kim, Soogeun;Kang, Dongmug;Yoo, Kyemook
    • Safety and Health at Work
    • /
    • v.6 no.3
    • /
    • pp.174-183
    • /
    • 2015
  • The major purpose of this study is to construct a retrospective exposure assessment for benzene through a review of literature on Korea. Airborne benzene measurements reported in 34 articles were reviewed. A total of 15,729 individual measurements were compiled. Weighted arithmetic means [AM(w)] and their variance calculated across studies were summarized according to 5-year period intervals (prior to the 1970s through the 2010s) and industry type. Industries were classified according to Korea Standard Industrial Classification (KSIC) using information provided in the literature. We estimated quantitative retrospective exposure to benzene for each cell in the matrix through a combination of time and KSIC. Analysis of the AM(w) indicated reductions in exposure levels over time, regardless of industry, with mean levels prior to the 1980-1984 period of 50.4 ppm (n = 2,289), which dropped to 2.8 ppm (n = 305) in the 1990-1994 period, and to 0.1 ppm (n = 294) in the 1995-1999 period. There has been no improvement since the 2000s, when the AM(w) of 4.3 ppm (n = 6,211) for the 2005-2009 period and 4.5 ppm (n = 3,358) for the 2010-2013 period were estimated. A comparison by industry found no consistent patterns in the measurement results. Our estimated benzene measurements can be used to determine not only the possibility of retrospective exposure to benzene, but also to estimate the level of quantitative or semiquantitative retrospective exposure to benzene.

Measurement of Dust Concentration in a Mechanically Ventilated Broiler House and Analysis of Dust Generation from Ground Beds (강제환기식 계사의 공기 중 분진 농도 측정 및 바닥재로부터의 분진 발생량 분석)

  • Kwon, Kyeong Seok;Jo, Ye Seul;Lee, In Bok;Ha, Tae Hwan;Hong, Se Woon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.56 no.6
    • /
    • pp.31-43
    • /
    • 2014
  • Confined and mechanically ventilated broiler house has been recently come into wide use to increase productivity and control rearing conditions. However, high dust concentration inside facility can threaten respiratory welfare of farmers and broilers. In Korea, there is no regulation in terms of air quality control inside agricultural facilities and sufficient data is not available. To cope with these, periodic monitoring of inhalable and respirable dust concentration were conducted according to season, broiler's activity and specific events such as shipment work for broilers in mechanically ventilated broiler house. Chamber experiment was also designed to analyze mechanism of dust generation from ground beds according to water contents and surrounding wind environment. Results showed that significant increase of inhalable (p=0.002) and respirable (p=0.03) dust were observed when activity of broilers was high according to entrance of the workers. Even shipment work for matured broilers, high level of dust were observed; inhalable dust was exceeded the threshold limit over maximum 303 % and respirable dust was over maximum 1,550 %, implying that acute respiratory symptoms could be manifested for the workers. From the chamber experiment, critical water contents for interrupting of dust generation were measured; about 45 % for inhalable dust and about 50 % for respirable dust. These results can be a trigger for designing plan of dust control however it still needs consideration of various environmental conditions, hygiene problems, etc.