• Title/Summary/Keyword: Wooden Shear Wall

Search Result 6, Processing Time 0.018 seconds

Shear Resistance Capacity Length of Traditional Wooden Frame's Wall divided into Small Frame (세부목골조로 구성된 전통목골조 벽체 전단저항능력)

  • Hwang, Jong-Kook;Kwon, Yang-Hee;Bae, Dong-Hun
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.3
    • /
    • pp.11-18
    • /
    • 2019
  • The purpose of this study was to estimate the resistance capacity of a traditional wooden house with shear walls made of wood panel. In order to achieve the purpose of the study, the load - displacement test was carried out and the resistance moment values of the shear walls were proposed. The shear walls were made by placing studs with a nominal dimension of $38mm{\times}89mm$ at intervals of 600 mm, and attaching 12 mm thick plywood with 8-d size pegs at intervals of 150 mm. The type of traditional building wall was classified and showed the moment resistance ability of each wall type. This value is expressed as a proportional value divided by the moment resisting capacity of the standard size shear walls not divided into the divided small frames. Although some frames have proportional values larger than 1.0 even though they have openings, most of them show values smaller than 1.0. Also, even without the openings, it showed a smaller value than 1, such as 0.84 and 0.67.

Strength Evaluation of Pinus rigida Miller Wooden Retaining Wall Using Steel Bar (Steel Bar를 이용한 리기다소나무 목재옹벽의 내력 평가)

  • Song, Yo-Jin;Kim, Keon-Ho;Lee, Dong-Heub;Hwang, Won-Joung;Hong, Soon-Il
    • Journal of the Korean Wood Science and Technology
    • /
    • v.39 no.4
    • /
    • pp.318-325
    • /
    • 2011
  • Pitch pine (Pinus rigida Miller) retaining walls using Steel bar, of which the constructability and strength performance are good at the construction site, were manufactured and their strength properties were evaluated. The wooden retaining wall using Steel bar was piled into four stories stretcher and three stories header, which is 770 mm high, 2,890 mm length and 782 mm width. Retaining wall was made by inserting stretchers into Steel bar after making 18 mm diameter of holes at top and bottom stretcher, and then stacking other stretchers and headers which have a slit of 66 mm depth and 18 mm width. The strength properties of retaining walls were investigated by horizontal loading test, and the deformation of structure by image processing (AlCON 3D OPA-PRO system). Joint (Type-A) made with a single long stretcher and two headers, and joint (Type-B) made with two short stretchers connected with half lap joint and two headers were in the retaining wall using Steel bar. The compressive shear strength of joint was tested. Three replicates were used in each test. In horizontal loading test the strength was 1.6 times stronger in wooden retaining wall using Steel bar than in wooden retaining wall using square timber. The timber and joints were not fractured in the test. When testing compressive shear strength, the maximum load of type-A and Type-B was 130.13 kN and 130.6 kN, respectively. Constructability and strength were better in the wooden retaining wall using Steel bar than in wooden retaining wall using square timber.

Shear Performance of Post and Beam Construction by Pre-Cut Process (프리컷 방식을 적용한 기둥-보 공법의 수평전단내력)

  • Hwang, Kweonhwan;Park, Joo-Saeng;Park, Moon-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.35 no.6
    • /
    • pp.1-12
    • /
    • 2007
  • For the purpose of effective utilization of domestic second-grown larch as structural members, post and beam construction applying traditional construction to Japanese larch glulam members was adopted with processing by machine pre-cut method. In general, horizontal shear test by KS F 2154 is conducted to assess the horizontal shear properties of the wooden structure by post and beam construction. The frame was consisted of post and beam member with appropriate fasteners, and members have their own processed parts (notch, hole, etc.) that can be well-connected each other. The shear wall was consisted of the frame with screw-nail sheathed panel (OSB). The results of horizontal shear loading tests without vertical loads conducted on the frame and the shear wall structures, the maximum strengths were about 1.9 kN/m and about 9.7 kN/m, the shear rigidities were about 167 kN/rad, 8198 kN/rad, respectively. The strength proportion of the frame specimen was about 20% of the wall's and about 2% in initial stiffness. Nail failures are remarkable on the shear wall specimen with punching shears and shear failures. The shear load factor for the shear wall specimen by the method of Architectural Institute of Japan was 1.5, which was obtained by the bi-linear method. Loading method should be considered to obtain smooth load-deformation relationship. For the better shear performance of the structures, column base and post and beam connections and sheathed panel should be further examined as well.

Shear Strength of Nailed Connection of Domestic Plywood as a Substitute for OSB (OSB 대체용 국내산 합판의 못 접합부 전단내력 성능)

  • Suh, Jin-Suk;Hwang, Sung-Wook;Hwang, Kweon-Hwan;Jeong, Gi-Young;Joung, Ha-Hyun
    • Journal of the Korean Wood Science and Technology
    • /
    • v.40 no.4
    • /
    • pp.287-293
    • /
    • 2012
  • This study was carried out in order to compare nail shear strength between domestic plywood and imported OSB for structural sheathing members as infill wall of wooden construction. The differences of nail shear strength between parallel-to-grain direction and perpendicular-to-grain direction of sheathing material to frame material were distinct at the plywood composition. The shear strengths of plywood and OSB with nail met current design values. The plywood of P-4 type, which uses MLH at surface layer and constructs 7 ply, showed greater than OSB regardless of grain direction of sheathing material to frame material. When the plywood as sheathing material to frame material was used, it was found out that the overall construction of perpendicular-to-grain direction of plywood had greater nail shear strengths than the construction of parallel-to-grain.

Strength Performance Evaluation of Threaded Nail Joints of Wooden Retaining Wall Using Pitch Pine (Pinus rigida Miller) Square Timber (리기다 소나무 정각재를 사용한 목재옹벽의 직결나사못 접합부 내력 성능 평가)

  • Song, Yo-Jin;Kim, Keon-Ho;Lee, Dong-Heub;Hwang, Won-Joung;Hong, Soon-Il
    • Journal of the Korean Wood Science and Technology
    • /
    • v.39 no.1
    • /
    • pp.53-59
    • /
    • 2011
  • A connection was made between a single stretcher and 2 headers with 2 threaded nails (Type-A), and another one between 2 stretchers and 2 headers with 4 threaded nails (Type-B) to use as specimens. Type-C was the stretchers that are connected with 2 threaded nails by half lap joint at end-distance 5D to reinforce Type-B, Type-C1 the stretchers that are connected by half lap joint at end-distance 10D, and Type-C2 with 3 threaded nails at end-distance 10D. Compressive shear strength of Type-C, the supplementation of Type-B, was decreased by 30%, compared with that of Type-B. Those of Type-B and Type-C1 that used longer end-distance than Type-C were about the same, and that of Type-C2 connected with 3 threaded nails was 1.28-times stronger than that of Type-C1. Connection of the retaining wall using existing square timber has a problem between long and short stretchers and 2 headers. So it was investigated in the experiment to replace it. Therefore, if Type-B is replaced with Type-C2 in constructing the retaining wall, the crack and the rupture of timber caused by threaded nail as well as construction period can be reduced, and also it can be expected to increase their own strength.

Wood Quality and Strength Properties of Old Structural Members (목조건축 해체 고목재의 재질특성 및 강도성능)

  • Hwang, Kweonhwan;Park, Byeongsu;Park, Moon-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.36 no.1
    • /
    • pp.36-44
    • /
    • 2008
  • It is necessary to assess wood quality and strength of the clear specimens from used members in old wooden structures for the reuse of old members on the same structure or a new structure. Wood species classification by microscope observation of each wood member that was used in truss cord and temple, and several physical and strength tests by the specification of present KS standards were conducted to compare with some references. From the comparison of strengths with references, Korean larch gives relatively better wood quality and mechanical properties than other wood species. No significant deterioration of cell wall was found by microscopic observation for the sound wood part that was selected visually. Tensile specimens with 3 mm in thickness on the middle span showed greater strength than 5 mm thick specimens, which explains that dimension of tensile specimen should be examined for evaluating precise tensile strength properties. Other tests, compression, shear, and bending, are adoptable for each strength properties. Test methods for the evaluation of basic strengths and fastener connections for old wood species should be further examined.