• Title/Summary/Keyword: With-Corona

검색결과 828건 처리시간 0.027초

Computation of Refractive Indices of Corona Viruses through Reverse Calculation

  • Kuppuswamy, Srinivasan;Swain, Kaliprasanna;Nayak, Suryakanta;Palai, Gopinath
    • Current Optics and Photonics
    • /
    • 제4권6호
    • /
    • pp.566-570
    • /
    • 2020
  • The present paper computes the refractive indices of different corona viruses (H5N1, H5N2, H9N2, H4N6, FAdV and IBV) through reflectance analysis of a virus solution. The computational analysis indicates that the refractive indices of all viruses are negative at the signal of 412 nm. Further the numerical output shows that the infectious bronchitis viruses (family of novel corona viruses, COVID-19) have higher negative refractive indices as compared to other corona viruses. Finally refractive indices of the family of COVID-19 are investigated with respect to the EID (Electronic infusion Device) concentration of the viruses, showing that the refractive index which ranges from "-0.96725 to -0.999998" corresponds to '0.01 to 10000' EID virus concentration.

UV 투과율 향상 필터 기술을 이용한 전력설비 방전 검출용 자외선 코로나 카메라 개발 (Development of UV Corona Camera for the Detecting of Discharge on Power Facility using UV Transmittance Improvement Filter)

  • 김영석;최명일;김종민;방선배;송길목
    • 전기학회논문지
    • /
    • 제61권11호
    • /
    • pp.1656-1661
    • /
    • 2012
  • UV inspection technology is being used for predictive maintenance of power facility together with IR-thermography and ultrasonic devices. In this paper, the UV corona camera design, fabrication, and perform a simple test to be take advantage of the diagnostic equipment. The UV corona camera developed a $6.4^{\circ}{\times}4.8^{\circ}$ of the field of view as a conventional camera to diagnose a wide range of slightly enlarged, and power equipment to measure the distance between the camera and the distance meter has been attached. The transmission between 250 to 280nm was 11% ($12.5%{\times}88%{\times}98%$) by combing the transmission on absorption film, window and other filter(UG 5, nickel sulphate and so on). In a distance of 5m with the UV corona camera it is possible to detect partial discharge with a PD level of 2.5pC and a RIV level of $3.6dB{\mu}V$.

장벽 방전형 공기 펌프의 이온풍 발생에 미치는 방전전극 형상의 영향 (Effect of Discharge Electrode Shape of a Barrier Discharge Type Gas Pump on Ionic Wind Generation)

  • 황덕현;문재덕
    • 전기학회논문지
    • /
    • 제58권5호
    • /
    • pp.994-998
    • /
    • 2009
  • Existing cooling technologies no longer provide adequate heat dissipation due to excessive heat generation caused by the growing component density on electronic devices. An ionic gas pump can be used for the thermal management of micro-electronic devices, since the size of pump can be reduced to a micrometer scale. In addition, the gas pump allows for gas flow control and generation without moving parts. This ideal property of gas pump gives rise to a variety of applications. However, all these applications require maximizing the wind velocity of gas pump. In this study a barrier discharge type gas pump, with a needle-shaped corona electrode instead of a plate-shaped corona electrode, has been investigated by focusing on the corona electrode shape on the wind velocity and wind generation yield. As a result, the enhanced wind velocity and wind generation yield of 1.76 and 3.37 times were obtained with the needle-shaped corona electrode as compared with the plate-shaped corona electrode of the proposed barrier discharge type gas pump.

코로나 모터를 이용한 송풍장치의 특성 연구 (The Study of Wind Blower Characteristics Using a Blade Type Corona Motor)

  • 정재승;김형표;김진규
    • 조명전기설비학회논문지
    • /
    • 제27권11호
    • /
    • pp.76-81
    • /
    • 2013
  • In this paper, a corona motor with blade type electrodes has been employed as a wind blower. The rotation speed was influenced significantly by the polarity of applied voltage and the number of blades. Therefore the effect of polarity of applied voltage and the number of blades on the electrical and mechanical fundamental properties of corona motor were investigated experimentally. The rotation speed decreased for increasing of number of blades, because the mass of blades increased. But the amount of air blow increased despite decreasing of the rotation speed, because air volume is not only influenced by rotation speed but also the number of blades and ionic wind which generated between blade tips and a induction electrode. Although space occupied by blades of the corona motor is smaller than the whole area of the blast pipe, wind rises a whole range of a wind blower for such reasons.

에틸메타크릴레이트 증기 분위기에서 코로나 방전 처리한 PVDF 필름의 XPS 분석 (XPS Analysis of PVDF Film Treated by Corona Discharge in Ethyl Methacrylate Vapor Atmosphere)

  • 문희권;서문규
    • 공업화학
    • /
    • 제27권6호
    • /
    • pp.627-632
    • /
    • 2016
  • PVDF-PVC 적층필름의 계면접착력을 향상시키기 위한 새로운 방법으로 PVDF 필름 표면에 유전체장벽 코로나 방전을 통한 EMA 단량체 커플링을 시도하였다. EMA 1% 분위기에서 코로나 표면처리한 PVDF 필름을 사용하여 제조한 PVDF-PVC 적층필름의 계면접착력은 코로나 처리하지 않은 PVDF에 비해 현저히 향상되었다. 코로나 방전처리에 의해 PVDF 필름 표면의 접촉각은 현저히 감소하였다. XPS 분석 결과, 코로나 처리에 의해 필름 표면의 탄소와 산소함량은 증가하는 반면 불소 함량은 감소하였다. XPS $C_{1s}$ 피크의 curve fitting 결과, 코로나 방전 처리에 의해 비극성 C-C 결합 탄소와 산소와 결합하는 탄소의 비율은 점차 증가한 반면, 불소와 결합하는 탄소의 비율은 크게 감소하는 경향을 나타내었다.

코로나방전 표면 처리시 이동속도 및 공급전력 변화에 따른 폴리프로필렌 표면 안전성 특성 (Surface Safety Characteristics of Polypropylene Surface Treatment by Variation of Rolling Speed and The Electric Power of Corona Discharge)

  • 이수환;이동훈
    • 한국안전학회지
    • /
    • 제33권1호
    • /
    • pp.41-46
    • /
    • 2018
  • Experiments were carried out the phenomenal observation on effect of corona treated hotmelt laminating film in process of manufacture by 2 kinds of rolling speed and electric power variatons. Surface treatment by corona which is exposure of film surface to electron of ion bombardment, rather than mere exposure to active species, like atomic oxygen or ozone, can enhance adhesion by removing contaminant, electret, roughening surface, and introducing reactive chemical group. Reactive neutrals, ions, electron and photons generated during the corona treatment interact simultaneously with polymers to alter surface chemical composition, wettability, and thus film adhesion. However, it is highly recommended that extensive chains scission is avoided because it can lead to side-effect by forming sticky matter, resulting in dropouts. This paper reviews principles of surface preparation of polypropylene substrate by corona discharging. In addition, the experimental section provides a description of parameter optimization on corona discharging treatment and its side-effect. Experimental results are discussed in terms of surface wetting as determined by contact angle and SEM measurements. When the rolling speed of the film decreased from 1.666 [m / sec] to 0.083 [m / sec], contact angle decreased from $80[^{\circ}]$ to $64[^{\circ}]$, and the wettability was greatly improved. As the supply power increased from 0.4 [kVA] to 2 [kVA] at the corona discharge surface treatment, the contact angle decreased from $77[^{\circ}]$ to $65[^{\circ}]$, and the wettability was greatly improved.

위드 코로나(With COVID-19)시대 노인의 여가활동과 삶의 만족도에 관한 연구 (A Study on Leisure Activities and Life Satisfaction of the Elderly in With COVID-19 Era)

  • 이경아;손희원
    • 한국콘텐츠학회논문지
    • /
    • 제22권10호
    • /
    • pp.445-459
    • /
    • 2022
  • 본 연구는 위드 코로나(With COVID-19)시대 노인의 삶의 만족도와 여가생활 현황과 노인의 삶의 만족을 증진하기 위한 방안을 제시하였다. 이를 위해 경기도 노인복지관 노인 107명을 대상으로 삶이 만족도, 여가생활에 대해 알아보았으며 다음과 같은 결과를 도출하였다. 첫째, 전체적으로 삶의 만족도가 코로나 이전보다 이후에 상대적으로 낮아졌음을 알 수 있다. 둘째, 여가활동과 삶의 만족도 상관관계에서는 코로나 이전의 경우 여가활동 정도와 삶의 만족도가 유의한 상관관계를 보이지 않았고, 코로나 이후의 경우 여가활동 정도와 삶의 만족도가 유의한 정적인 상관관계를 보였다. 이러한 결과에 따라 대안방안을 제시하면 첫째, 지역사회에서 위드 코로나 시대에 맞는 노인을 위한 환경 개선과 관리할 수 있는 방안을 모색할 필요가 있다. 특히 디지털에 많은 변화로 노인들의 적응 격차를 줄이기 위해 노인관련 기관에서는 스마트폰, 키오스크 사용 방법 등의 교육을 실시하고 있으나 지역사회 차원의 방안으로 좀 더 확대될 필요가 있다. 둘째, 위드 코로나 시대에 노인건강관리를 위한 체계적인 시스템이 갖춰 줘야 한다. 셋째, 코로나로 인해 경제적인 어려움을 겪고 있는 노인을 위해 최소한의 생활보장이 보장되도록 노후소득보장제도 및 지원이 요구 되어진다. 넷째, 코로나로 인해 사회적 거리 및 관계위축으로 인한 관계 개선 및 위치 만족을 위한 노인들의 말벗과 상담 관련 프로그램 활성화가 필요하다.

코로나 방전처리와 아크릴아미드 그라프트 중합에 의한 고분자 표면개질 (Modification of Polymer Surface by Corona Discharge and the Subsequent Graft Polymerization of Acrylamide)

  • 김형우;김찬영;박병기
    • 한국염색가공학회지
    • /
    • 제5권1호
    • /
    • pp.26-32
    • /
    • 1993
  • This study is concerned with the graft polymerization of acrylamide onto the surfaces of polyethylene and polyethylene terephthalate films treated with on corona discharge. In the case, peroxides formed by the corona discharge treatment are likely to be the species responsible for initiating the graft polymerization. This treatment produced a continuous charge in wettability and also amid group density on the polymer surface, as evidenced by water contact angle measurement, Fourier-transform infrared spectroscopy in the attenuated total reflectance mode, and electron spectroscopy for chemical analysis. Both of the merely corona-treated film and the subsequently grafted film are discussed as a function of time after treatment and water washings.

  • PDF

Surface Characterization of Silicone Rubber for Outdoor Insulation by Measurement of Surface Voltage Decay

  • Youn, Bok-Hee;Huh, Chang-Su;Cho, Han-Gu
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제12C권4호
    • /
    • pp.214-219
    • /
    • 2002
  • The influence of ultraviolet (UV) irradiation and corona on the surface degradation of high temperature vulcanized (HTV) silicone rubber used for outdoor insulation through measuring surface voltage decay after corona charging, surface resistivity, contact angle and X-ray photoelectron spectroscopy (XPS) analysis was studied. The surface resistivity calculated by the surface voltage decay was compared with a value directly obtained from the three electrode method having the guard ring electrode. A good agreement between the two methods for surface resistivity was obtained. UV treated specimens showed the slower decrease of surface voltage decay, while the corona exposed specimens showed a dramatically faster decrease. Although both artificial treatments cause the same oxidative products, which was confirmed with XPS, we could distinguish the difference between the reactions of the two treatments by monitoring the surface voltage decay on corona-charged specimen. In addition, we could derive the specific surface states of the silicone rubber treated by accelerated artificial aging factors and the degradation process.

상온 펄스 코로나 방전 공정에 의한 NO 제거 효율 (NO Removal Efficiency by Pulsed Corona Discharge Process at Room Temperature)

  • 김동주;박정환;김교선
    • 한국대기환경학회지
    • /
    • 제18권5호
    • /
    • pp.337-344
    • /
    • 2002
  • In this study, we analyzed the NO removal efficiency by the pulsed corona discharge process and investigated the effects of several process variables such as initial concentrations of NO, $H_2O$, and NH$_3$, applied voltage, pulse frequency, diameter of the discharge electrode, and residence time. The removal efficiency of NO increased by the addition of $H_2O$ or NH$_3$, but the changes of initial NH$_3$ and $H_2O$ concentrations did not affect the removal efficiency of NO significantly. With the increases of the applied voltage or the residence time, the removal efficiency of NO increased. In addition, with the increases of the pulse frequency of applied voltage, or the diameter of the discharge electrode, the removal efficiency of NO increased. The experimental results can be used as a basis to design the pulsed corona discharge process to remove NO$_{x}$, SO$_{x}$ and VOCs.OCs.