• Title/Summary/Keyword: With-Corona

Search Result 828, Processing Time 0.028 seconds

Breakdown voltage characteristics of air with vertical arranged electrodes due to flame (화염에 의한 수직배치전극에서 공기의 절연파괴전압특성)

  • Kim, C.N.;Jee, S.W.;Lee, K.S.;Lee, D.I.;Kim, I.S.;Kim, L.K.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1735-1737
    • /
    • 2001
  • The occurrence of fires under transmission lines is responsible for a great number of power line outages. In this paper, the ac flashover voltages and the corona onset voltages of a needle-plane electrode gap of vertical arrangement in the presence of flame were investigated. We also observed the corona discharge current and variation of shapes in flame with increasing the applied voltages. We found that the corona onset voltages and the flashover voltages were drastically decreased with the position of flames and gap length of electrodes, and observed that the deflection or fluctuation phenomena in the shape of flames.

  • PDF

Prebreakdown Corona Processes of Point-to-Plane Gap in $SF_{6}$ Gas ($SF_{6}$ 가스중에서 침-평판가극의 전구코로나과정)

  • 이복희;백용현
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1992.05a
    • /
    • pp.140-143
    • /
    • 1992
  • This paper deals with the dielectric behaviors of $SF_{6}$ gas and prebreakdown growth caused by lightning impulse voltages in inhomogeneous field perturbed with a fixed needle-shaped protrusion on the electrode. The measuring interpretation of the external current induced by moving charges is described. The temporal growth of prebreakdown is obserbed by using a shunt and photomultiplier. The prebreakdown processes are initiated by the first streamer corona at a needle protrustion, the flashover of the main gap in the positive polarity is very sensitive to the local field and propagates into the gap with the leader mechanism. It is found that the dependence of the prebreakdown phenomena on the polarity of applied voltages is caused by the effect of space charges. In addition, the proposed measuring techniques are very useful to perform the measurements of avalanche currents, corona discharges in inhomogeneous fields ad partial discharges in voids.

  • PDF

A Study on the Surface Properties of Wool Fabric Treated with Enzyme (효소가공 양모직물의 표면 성질에 관한 연구)

  • 박미라;김환철;박병기
    • Textile Coloration and Finishing
    • /
    • v.13 no.4
    • /
    • pp.227-233
    • /
    • 2001
  • Wool fabrics were pre-treated with corona prior to treating with enzyme for shrinkage resistance. Commercial protease and cellulase were used for degradation of wool and the treatment conditions such as enzyme amount, treating time, and assistant chemicals. Friction coefficient and zeta-potential were measured to certificate an effect of treatment condition on the handle of wool fabric. Corona pretreatment make the wool fabric soft, which result in the decrease of friction coefficient and zeta-potential. Scale removal of wool surface was observed by scanning electron microscope. Amino acid analysis shows the effectiveness of enzyme, and corona pretreatment does not cause severe internal damage.

  • PDF

An Assessment of Urbanization Using Historic Satellite Photography: Columbus Metropolitan Area, Ohio, 1965

  • Kim, Kee-Tae;Kim, Jung-Hwan;Jayakumar, S.;Sohn, Hong-Gyoo
    • Korean Journal of Remote Sensing
    • /
    • v.23 no.3
    • /
    • pp.221-227
    • /
    • 2007
  • We present an analysis of urban development and growth with reconnaissance satellite photographs of Columbus metropolitan area acquired by the Corona program in 1965. A two-dimensional polynomial linear transformation was used to rectify the photos against United State Geological Survey (USGS) Large-scale Digital Line Graph (DLG) data georeferenced to Universal Transverse Mercator (UTM) coordinates. The boundaries of the Columbus metropolitan area were extracted from the rectified Corona image mosaic using a Bayesian approach to image segmentation. The inferred 1965 urban boundaries were compared with 1976 USGS Land Use and Land Cover (LULC) data and boundaries derived from 1988 and 1994 Landsat TM images. The urban area in and around Columbus approximately doubled from 1965 to 1994 (${\sim}110%$) along with population growth from 1960 to 1998 (${\sim}50%$). Most of the urban expansion results from development of residential units.

Simulation Study of Corona Discharge According to Flue Gas Conditions (배기가스 조건에 따른 코로나 방전 현상 시뮬레이션)

  • 정재우;조무현
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.17 no.2
    • /
    • pp.223-231
    • /
    • 2001
  • In order to provide some insights into the influence of electric field, gas composition, and gas temperature on electron energy distribution and electron transport characteristics, the Boltzmann equation was solved by using cross section data for electron collisions, Critical electric fields for the corona development in dry air and flue gas are 150 and 80 Td, respectively. It was seen that the decrease of critical electric field in flue gas is mainly caused by the $H_2O$ addition through the comparison of ionization and attachment coefficients of gas components. Increase of $O_2$, $H_2O$, and $CO_2$ contents in gas affected discharge characteristics according to their reciprocal characteristics between lowering the ionization threshold and increasing the electro-negativity. As electric field increases, electrons with higher energies in the electron energy distribution also increase. The mean and characteristic electron energies also linearly increase with electric field. The variation of flue gas temperature did rarely affect on the electron energy distribution function and electron transport characteristics, because the gas temperature is several hundreds or thousands times lower than the electron temperature.

  • PDF

Vibronic Spectroscopy of Jet-Cooled Benzyl-type Radicals Produced from 2-Fluoro-4-Chlorotoluene by Corona Discharge

  • Chae, Sang Youl;Yoon, Young Wook;Lee, Sang Kuk
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.12
    • /
    • pp.3565-3569
    • /
    • 2013
  • A home-made pinhole-type glass nozzle was employed to generate vibronically excited but jet-cooled benzyl-type radicals from precursor 2-fluoro-4-chlorotoluene with a large amount of carrier gas He, from which the visible vibronic emission spectrum was recorded with a long-path monochromator. From an analysis of the spectrum observed, it was found that two benzyl-type radicals, 2-fluorobenzyl and 2-fluoro-4-chlorobenzyl radicals, were formed from the precursor in corona discharge. The possible pathway for the production of benzyl-type radicals that can explain the spectroscopic observation is herein proposed. In addition, the electronic energy of the $D_1{\rightarrow}D_0$ transition and the vibrational mode frequencies in the $D_0$ state of the 2-fluoro-4-chlorobenzyl radical were determined for the first time.

Spectroscopic Identification of Isomeric Trimethylbenzyl Radicals Generated from 1,2,3,4-Tetramethylbenzene

  • Yoon, Young-Wook;Lee, Sang-Kuk
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.8
    • /
    • pp.2751-2755
    • /
    • 2011
  • The visible vibronic emission spectrum was recorded from the corona discharge of precursor 1,2,3,4-tetramethylbenzene with a large amount of inert carrier gas helium using a pinhole-type glass nozzle coupled with corona excited supersonic expansion. The spectrum showed a series of vibronic bands in the $D_1{\rightarrow}D_0$ electronic transition of jet-cooled benzyl-type radicals formed from the precursor in a corona excitation. The analysis confirmed that two isomeric radicals, 2,3,4- and 2,3,6-trimethylbenzyl radicals, were produced as a result of removal of a hydrogen atom from the methyl group at different substitution positions. For each isomeric product, the electronic transition and a few vibrational mode frequencies were determined in the ground electronic state.

Effects of Surface Charges on Hydrophobicity and Surface Potential Decay with Various Surface States of Silicone Rubber for Outdoor Insulator (옥외용 실리콘 절연재료의 발수성에 미치는 표면전하의 영향과 표면 상태에 따른 표면전위 감쇠)

  • 연복희;박충렬;허창수
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.8
    • /
    • pp.678-686
    • /
    • 2002
  • This paper presents the effects of accumulation of surface charges on hydrophobic level and the changes of surface potential decay with various artificial environment treatments on high temperature vulcanized (HTV) silicone rubber used for outdoor insulating material. For this study, the charging apparatus by corona discharge, in which grid electrode was installed between the main corona and ground electrode, was used. From this study, it was found that the accumulation of surface charges above a critical surface potential on silicone insulating materials could lead to the temporary loss of surface hydrophobicity. In addition, corona stress and water absorption stress increase the decay rate of surface charges of HTV silicone rubber, while ultraviolet (UV) stress causes longer decay time. We could conclude that the effects of surface charges on hydrophobicity level and the changes of surface state by various artificial treatments were found through a trend of surface potential decay.

A Study on the Characteristic of Ozone and $NO_x$ Generation in the Electerostatic Precipitators (정전식 집진기에서 오존, $NO_x$ 발생특성에 관한 연구)

  • Noh, Kwang-Chul;Lee, Young-Ho;Oh, Myung-Do
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1423-1428
    • /
    • 2003
  • We investigated the amount of the toxic gases emitted from the Electrostatic Precipitators(ESPs), which were currently used by indoor air cleaners. We used the wire-to-plate(WTP) type and the needle-to-plate(NTP) type corona discharger in our study. Using the voltage, the polarity of wire, the number of needles of NTP as the input variables, we studied the characteristic of Ozone and $NO_x$ generation in the ESPs. As the results, we found out that the concentration of Ozone, $NO_2$ and $NO_x$ is increased, but the amount of NO is decreased with increasing the voltage and the number of needles. And we knew that the generation rate of ozone and $NO_x$ is very related with the corona region.

  • PDF

The Analysis of Partial Discharges Pattern using Discrete Wavelet Transform (이산 웨이브렛변환에 의한 부분방전패턴 분석)

  • 이현동;김충년;지승욱;박광서;이광식;이동인
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.183-187
    • /
    • 2000
  • This paper deals with multiresolution analysis of wavelet transform for partial discharge(PD), both corona and surface discharge. Multiresolution analysis was used for performing discrete wavelet transform. PD signals was decomposed into "approximation" and "detail" components until 4 levels by using discrete wavelet analysis. In this paper, daubechies family is adopted for the research of the characteristics of PD signals. The results show that in corona discharge the segment 7, 8, 9, 10, 11 values of defined variable is increased with discharge process, so phase distribution is characterized by 210~330 ranges. In case surface discharge in expoxy insulator inserted, defined variable values is fairly symmetric discharge pattern because coupled both corona and dielectric bounded discharges. We can confirmly discriminate the type PD source. the type PD source.

  • PDF