• Title/Summary/Keyword: Wireless Railway

Search Result 215, Processing Time 0.025 seconds

Study on the Effect of the Wireless Internet Within the Platform Inside a Subway Station on the ZigBee Wireless Sensor Network (지하철역사 내 승강장의 무선 인터넷이 ZigBee 무선 센서 네트워크에 미치는 영향에 대한 연구)

  • An, Tae-Ki;Shin, Jeong-Ryeol;Kim, Gap-Young;Yang, Se-Hyun;Sim, Bo-Seog
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.2762-2767
    • /
    • 2011
  • With increasing use of wireless mobile devices like smartphone and tablet PC, telecommunication companies have been providing the internet service by installing a multitude of access points (AP) in subway stations. Most of these APs use frequency of 2.4 GHz band range and the three telecom providers (SKT, KT, LGT) are using the limited channels within this range without any regulations. The channels within 2.4GHz band are already saturated as the companies are setting up wireless AP even within the subway trains for better service. This can affect other 2.4GHz wireless devices used for other purposes with channel interference, etc. This study has tested and analyzed the effects of the wireless APs installed within the subway stations and trains for the internet service on ZigBee-based sensor network for the intelligent surveillance system of urban transit, which is currently being developed and installed.

  • PDF

Railway Access Alarm System Using Infrared Distance Sensor and Wireless Communication (적외선 센서와 무선통신을 이용한 열차접근경보시스템 개발)

  • Hwang, Yun-Tae;Hwang, Sung-Tae;Lee, Yun-Sung;Kim, Do-Keun;Lee, Tae-Gyu
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.11
    • /
    • pp.303-311
    • /
    • 2017
  • Safety accidents in railway work continue to increase every year; Engineer's negligence, trackside worker's sensory deprivation and signalman's mistake are the main reasons of such incidents. We consider this problem by far the most urgent matter in railway work because of its steady increase and risk of taking a person's life. Based on that account, a new alarm system has developed, that is called Railway Access Alarm System, to allow railway workers to sense the access of trains with not only vision, but also hearing. The detector device of this system is installed on both sides of the track locating 1.5km from the workplace. When the train enters the place, the detector device can sense the entering, sending the detect sign of train to the alarm unit, then the alarm unit warns the workers by the LED lighting and sirens. This system has several advantages compared to previous systems. First, it recognizes the train at a long distance. Secondly, there is no need for wiring work since it is a wireless system. At last, the system works by rechargeable batteries and solar charger so that it is installed in the work places where there is no external power supply. Moreover, it is proven that the system is 100% reliable by the successful on-the spot inspection evaluating the capability.

A study of Operational Scenarios for the Wireless Communications Based Train Control System (도시철도용 무선통신기반 열차제어시스템 운영시나리오 연구)

  • Yoon, Yong-Ki;Oh, Seh-Chan;Lee, Kang-Mi;Jo, Hyun-Jeong;Kim, Yong-Kyu
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.904-909
    • /
    • 2011
  • The development of train control system shall operate a series of processes like system designing, system production and system performance evaluation as a result of various requirements analysis presented in operation rules, operating guidelines for railway organizations etc, notified by the nation. Therefore, considering operation conditions, operation plan, linkage to railway network etc, the major document like system functional specifications, system development specifications, system test plans etc must be drawn up. In this paper we classify system operating scenarios required to prepare for system standard specification and system performance evaluation report of CBTC system for urban subways supporting unmanned automatic operation, and adjust each of the operating status.

  • PDF

Network Design for Construction of Remote Diagnosis System for Power Facilities of Electric Railway (전기철도 전력시설 진단용 원격진단시스템 구축을 위한 네트워크 설계)

  • Kim, Jae-Moon;Kim, Yang-Su
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.4
    • /
    • pp.432-436
    • /
    • 2009
  • This paper is described that advanced study on network design of remote diagnosis system for power facilities of electric railway. In the field, it is very difficult for worker to diagnosis power facilities including catenary because workers should be maintenance on AC power supply. Therefore, to properly design on remote diagnosis system, we have searched the inside and outside of the country-related technology trends. Also we confirmed that required technologies to design interface technology required for the development of sensor devices and the USN network was designed in accordance with required skills. Throughout variety of requirements, we have development iRFS based ZA sensors and iRFM to receive data of sensor. Also CC2420 is applied as single-chip which used 2.4GHz IEEE802.15.4 compliant RF tranciver designed for low-power and low-voltage wireless applications for ZigBee communication.

Characteristic Measurement by a Real-time Data Acquisition System in Overhead Contact Wire (실시간 계측시스템을 이용한 전차선로 특성 측정)

  • Na, Hae-Kyung;Park, Young;Cho, Yong-Hyeon;Lee, Ki-Won;Park, Hyun-Jun;Oh, Su-Young;Song, Joon-Tae
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.3
    • /
    • pp.281-285
    • /
    • 2007
  • Facilities of electric railway should be maintained only at night and it is necessary to maintain by human power because facilities are installed at a high place. This paper presents the development and application of a real-time data acquisition system for the characteristics measurement of overhead contact wires in electric railway. The system is designed to perform in the telemetry environments that developed to store data by wireless in a live wire state of 25 kV power source. The field test results show that the proposed technique and the developed system can be practically applied to measure characteristics of temperature, displacement, and strain on overhead contact lines.

Development of Safety Monitoring System for Operating Railway Tunnel (운용중인 철도터널의 안전관리 시스템 시범구축)

  • Lee, Su-Hyung;Shin, Min-Ho;Kim, Hyun-Ki
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.73-78
    • /
    • 2008
  • There has been need for safety monitoring systems for the social infrastructures. These infrastructures are subject to degradation over time, reduced functionality, and loss of functionality as a result of factors such as a wide variety of installation environments, natural disasters, and nearby work. Therefore, it is necessary to perform appropriate inspections, repairs, and renovations to ensure safe and efficient maintenance and operation. This paper introduces the example of the development of the safety monitoring system for operating railway tunnel. Tunnel profile measuring system using laser beam, crack gauges, accelerometer and a pluviometer were implemented to monitor the safety of a deteriorated tunnel. The measured data were transferred through wireless network and analyzed in real time. The safety criteria for tunnel stabilities and train operations are also discussed.

  • PDF

A Analysis on wireless performance of unified data transmission in a subway and railway (18GHz 차지상간통합데이터전송 시스템의 지하 및 지상구간 무선특성 분석)

  • Jeong, Sang-Guk;An, Tae-Ki;Kim, Baek-Hyun;Choi, Gab-Bong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.6
    • /
    • pp.1083-1090
    • /
    • 2009
  • In 18GHz using unified data transmission in a subway and railway, Influence of the multipath fading is big and an arrival range of the micro wave takes the influence greatly according to the transmit angle and receive angle because it not diffracted. This thesis analyzed microwave property underground tunnel and ground railway at unified data transmission in subway and railway. Antenna gain of directional antenna many used unified transmission in an subway and railway, is used 15dBi and 10dBi in simulation. Transmitter's property is compared underground tunnel to ground railway about curved railway of R=100, R=200, R=400. Specification of transmitter is used sample unified transmission system in subway and railway of KRRI(korea railroad research Institute). Transmitter's power is 20dBm and Reciever's sensitivity is -90dBm. According to result of simulation.

A Study on Improvement of PSD Interface Using 2.4GHz Wireless Communication, (2.4GHz 무선 통신을 이용한 PSD 인터페이스 개선에 관한 연구)

  • Kim, Jae-Pil;Hyun, Yong-Sub;Chang, Kyong-Song
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.1408-1415
    • /
    • 2007
  • To operate Platform Screen Door (PSD) automatically, the operational data of PSD and the train must be interfaced properly. PSD and train are operated together by the signaling system in Automatic Train Operation (ATO) signaling system zone where interfaces are provided between PSD and train. However, the additional PSD interface system with train is required in train operating zone without the interface between PSD and train. For the PSD interface, the wireless communication system or the train status (train correct stop status / train door status) detection system has been used. Seoul Metro line No.2. has the PSD wireless communication system using 447MHz band RF. For the safety of PSD operation, it is required to prevent RF interference in the subway environment where many frequencies exist. In this paper, the PSD wireless communication system is developed using 2.4GHz band RF to prevent the interference of the wireless communication and increase the traffic of the PSD interface. Furthermore, the improved system can store, manage and display the PSD and train operational data using Human Machine Interface (HMI) in the train's driver cab.

  • PDF

Implementation of OFDM Transceiver for Multiple Access at 18GHz (18GHz 다중통신을 위한 OFDM송수신 모듈 구현)

  • Jeong, Sang-Guk;An, Tae-Ki;Kim, Back-Hyun;Choi, Gab-Bong;Park, Jong-Chol
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.1155-1160
    • /
    • 2011
  • The importance of broadband wireless communication implemented at subway tunnels is growing up. At 18GHz wireless video transmission system, the transmitter requires a digital modulation method. At subway tunnel, A 18GHz's influence of the multi-pass padding is strong. OFDM digital modulation that is strong for multi-pass padding is recommended. Duplexing methode uses FDD to transmit and receive broadband data at the same time. In the case of FDD we assign a private use channel each with the transmission at the receiving. In this paper, We implement multiple access wireless OFDM transceiver. We verified that one ground transceiver communicates with two car transceiver at the same time.

  • PDF

The SOC Management Strategy of Battery System for Propulsion in Wireless Low Floor System (무가선 저상트램 추진배터리 시스템의 SOC관리 전략)

  • Oh, Yong-Kuk;Kwak, Jae-Ho;Lee, Ho-Yong
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.2329-2335
    • /
    • 2011
  • The Wireless low floor tram uses the energy more effectively than other systems with onboard battery system. But for this the SOC(state of charge) management of the battery system is required. This paper is focused on the SOC management strategy of battery system for propulsion in wireless low floor tram. For minimizing consumption energy, the SOC management strategy that maximizes the regeneration energy is studied. The SOC operating region is divided to overcome the limited life cycle pointed out as a disadvantage of battery system. And the effective energy management strategy of tram is suggested through the charge/discharge of the battery system according to tram status in catenary/catenary-free section.

  • PDF