Cable Tunnel Monitoring System by Wireless Sensor Network (무선센서 네트워크에 의한 지하 통신구 터널 모니터링 연구)

  • Kim, Hyung-Woo;Moon, Tae-Gyun
    • 한국방재학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.549-552
    • /
    • 2008
  • In this study, we deployed the cable tunnel inspection and monitoring system by wireless sensor network. It is shown that the wireless sensor network which is composed of sensor, wireless communication module, and gateway can be applied to cable tunnel monitoring system. Sensors considered herein are flame detection sensor, flood detection sensor, intruder detection sensor, and temperature sensor, etc. It is also found that the wireless sensor network can deliver sensing data reliably by wireless sensing technology. The gateway system that can transmit sensed data to server by CDMA is developed. Monitoring system is constructed by web service technology, and it is observed that this system can monitor the present state of tunnel without difficulties. The system provides an alternative to inspecting and monitoring the tunnel efficiently where the conventional wired system is infeasible.

  • PDF

Real-time structural damage detection using wireless sensing and monitoring system

  • Lu, Kung-Chun;Loh, Chin-Hsiung;Yang, Yuan-Sen;Lynch, Jerome P.;Law, K.H.
    • Smart Structures and Systems
    • /
    • v.4 no.6
    • /
    • pp.759-777
    • /
    • 2008
  • A wireless sensing system is designed for application to structural monitoring and damage detection applications. Embedded in the wireless monitoring module is a two-tier prediction model, the auto-regressive (AR) and the autoregressive model with exogenous inputs (ARX), used to obtain damage sensitive features of a structure. To validate the performance of the proposed wireless monitoring and damage detection system, two near full scale single-story RC-frames, with and without brick wall system, are instrumented with the wireless monitoring system for real time damage detection during shaking table tests. White noise and seismic ground motion records are applied to the base of the structure using a shaking table. Pattern classification methods are then adopted to classify the structure as damaged or undamaged using time series coefficients as entities of a damage-sensitive feature vector. The demonstration of the damage detection methodology is shown to be capable of identifying damage using a wireless structural monitoring system. The accuracy and sensitivity of the MEMS-based wireless sensors employed are also verified through comparison to data recorded using a traditional wired monitoring system.

System identification of a building structure using wireless MEMS and PZT sensors

  • Kim, Hongjin;Kim, Whajung;Kim, Boung-Yong;Hwang, Jae-Seung
    • Structural Engineering and Mechanics
    • /
    • v.30 no.2
    • /
    • pp.191-209
    • /
    • 2008
  • A structural monitoring system based on cheap and wireless monitoring system is investigated in this paper. Due to low-cost and low power consumption, micro-electro-mechanical system (MEMS) is suitable for wireless monitoring and the use of MEMS and wireless communication can reduce system cost and simplify the installation for structural health monitoring. For system identification using wireless MEMS, a finite element (FE) model updating method through correlation with the initial analytical model of the structure to the measured one is used. The system identification using wireless MEMS is evaluated experimentally using a three storey frame model. Identification results are compared to ones using data measured from traditional accelerometers and results indicate that the system identification using wireless MEMS estimates system parameters with reasonable accuracy. Another smart sensor considered in this paper for structural health monitoring is Lead Zirconate Titanate (PZT) which is a type of piezoelectric material. PZT patches have been applied for the health monitoring of structures owing to their simultaneous sensing/actuating capability. In this paper, the system identification for building structures by using PZT patches functioning as sensor only is presented. The FE model updating method is applied with the experimental data obtained using PZT patches, and the results are compared to ones obtained using wireless MEMS system. Results indicate that sensing by PZT patches yields reliable system identification results even though limited information is available.

Wireless structural health monitoring of stay cables under two consecutive typhoons

  • Kim, Jeong-Tae;Huynh, Thanh-Canh;Lee, So-Young
    • Structural Monitoring and Maintenance
    • /
    • v.1 no.1
    • /
    • pp.47-67
    • /
    • 2014
  • This study has been motivated to examine the performance of a wireless sensor system under the typhoons as well as to analyze the effect of the typhoons on the bridge's vibration responses and the variation of cable forces. During the long-term field experiment on a real cable-stayed bridge in years 2011-2012, the bridge had experienced two consecutive typhoons, Bolaven and Tembin, and the wireless sensor system had recorded data of wind speeds and vibration responses from a few survived sensor nodes. In this paper, the wireless structural health monitoring of stay cables under the two consecutive typhoons is presented. Firstly, the wireless monitoring system for cable-stayed bridge is described. Multi-scale vibration sensor nodes are utilized to measure both acceleration and PZT dynamic strain from stay cables. Also, cable forces are estimated by a tension force monitoring software based on vibration properties. Secondly, the cable-stayed bridge with the wireless monitoring system is described and its wireless monitoring capacities for deck and cables are evaluated. Finally, the structural health monitoring of stay cables under the attack of the two typhoons is described. Wind-induced deck vibration, cable vibration and cable force variation are examined based on the field measurements in the cable-stayed bridge under the two consecutive typhoons.

Cable tunnel monitoring system by wireless sensor network (무선센서 네트워크에 의한 통신구 모니터링 시스템 개발)

  • Kim, Hyung-Woo
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.176-180
    • /
    • 2007
  • In this study, we deployed the cable tunnel inspection and monitoring system by wireless sensor network. It is shown that the wireless sensor network which is composed of sensor, wireless communication module, and gateway can be applied to cable tunnel monitoring system. Sensors considered herein are flame detection sensor, flood detection sensor, intruder detection sensor, and temperature sensor, etc. It is also found that the wireless sensor network can deliver sensing data reliably by wireless sensing technology. The gateway system that can transmit sensed data to server by CDMA is developed. Monitoring system is constructed by web service technology, and it is observed that this system can monitor the present state of tunnel without difficulties. The system provides an alternative to inspect and monitor the tunnel efficiently where the conventional wired system is infeasible.

  • PDF

System Identification of a Building Structure Using Wireless MEMS System (무선 MEMS 시스템을 이용한 구조물 식별)

  • Kim, Hong-Jin
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.4
    • /
    • pp.458-464
    • /
    • 2008
  • The structural health monitoring has been gaining more importance in civil engineering areas such as earthquake and wind engineering. The use of health monitoring system can also provide tools for the validation of structural analytical model. However, only few structures such as historical buildings and some important long bridges have been instrumented with structural monitoring system due to high cost of installation, long and complicated installation of system wires. In this paper, the structural monitoring system based on cheap and wireless monitoring system is investigated. The use of advanced technology of micro-electro-mechanical system(MEMS) and wireless communication can reduce system cost and simplify the installation. Further the application of wireless MEMS system can provide enhanced system functionality and due to low noise densities. Identification results are compared to ones using data measured from traditional accelerometers and results indicate that the system identification using wireless MEMS system estimates system parameters accurately.

Rapid-to-deploy reconfigurable wireless structural monitoring systems using extended-range wireless sensors

  • Kim, Junhee;Swartz, R. Andrew;Lynch, Jerome P.;Lee, Jong-Jae;Lee, Chang-Geun
    • Smart Structures and Systems
    • /
    • v.6 no.5_6
    • /
    • pp.505-524
    • /
    • 2010
  • Wireless structural monitoring systems consist of networks of wireless sensors installed to record the loading environment and corresponding response of large-scale civil structures. Wireless monitoring systems are desirable because they eliminate the need for costly and labor intensive installation of coaxial wiring in a structure. However, another advantageous characteristic of wireless sensors is their installation modularity. For example, wireless sensors can be easily and rapidly removed and reinstalled in new locations on a structure if the need arises. In this study, the reconfiguration of a rapid-to-deploy wireless structural monitoring system is proposed for monitoring short- and medium-span highway bridges. Narada wireless sensor nodes using power amplified radios are adopted to achieve long communication ranges. A network of twenty Narada wireless sensors is installed on the Yeondae Bridge (Korea) to measure the global response of the bridge to controlled truck loadings. To attain acceleration measurements in a large number of locations on the bridge, the wireless monitoring system is installed three times, with each installation concentrating sensors in one localized area of the bridge. Analysis of measurement data after installation of the three monitoring system configurations leads to reliable estimation of the bridge modal properties, including mode shapes.

Study of Modeling for Stock Food Material with Location Movement by the Communication Signal System

  • Kim, Jeong-Lae;Kim, Jung-Yun;Rha, Young-Ah
    • International Journal of Advanced Culture Technology
    • /
    • v.9 no.4
    • /
    • pp.409-416
    • /
    • 2021
  • We are invented the movement composition technique that is to check the food adjacent-package status of the wireless-management movement monitoring level (WMMML) on the movement monitoring communication system. The movement monitoring level condition by the movement monitoring communication system is formatted with the adjacent-package system. As to inspection a wireless RFID of the wireless RFID, we are found of the movement value with wireless RFID by the adjacent upper take form. The concept of movement monitoring level is formatted the reference of wireless-management level for composition signal by the movement package communication system. Further symbolizing a food composition of the WMMML of the medium-minimum in terms of the adjacent-package communication system, and the movement wireless RFID package that was the movement value of the far composition of the Mo-MMCS-FA-φMED-MIN with 5.80±1.20 units, that was the movement value of the convenient composition of the Mo-MMCS-CO-φMED-MIN with 4.06±(-0.04) units, that was the movement value of the flank composition of the Mo-MMCS-MO-φMED-MIN with 0.91±0.07 units, that was the movement value of the vicinage composition of the Mo-MMCS-VI-φMED-MIN with 0.18±(-0.03) units. The adjacent package will be to look into at the food ability of the adjacent-package communication system with wireless RFID by the movement monitoring level on the WMMML that is supply the wireless communication by the movement monitoring level system. We will be possible to make effort of a communication system by the management signal and to put to use of the delivery data of RFID level by the delivery system.

Tunnel Inspection and Monitoring System by Wireless Sensor Network (무선센서네트워크를 이용한 터널 모니터링 시스템)

  • Kim Hyung-Woo;Han Jin-Woo
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.91-94
    • /
    • 2006
  • In this paper, we deployed the tunnel inspection and monitoring system by wireless sensor network. It is shown that the wireless sensor network which is composed of sensor, wireless communication module, and gateway system can be applied to tunnel monitoring system. Sensors included herein are acceleration transducers, fire-alarm sensors, water-level sensors, and magnetic contact sensors. It is also found that the wireless sensor network can deliver sensing data reliably by ad-hoc networking technology. The gateway system that can send the sensing data to server by CDMA (code division multiple access) is developed. Finally, monitoring system is constructed by web service technology, and it is observed that this system can monitor the present state of tunnel without difficulties. Furthermore, the above system provides an alternative to inspect and monitor the tunnel efficiently where the conventional wired system cannot be applied.

  • PDF

Environmental Monitoring System for Base Station with Sensor Node Networks

  • Hur, Chung-Inn;Kim, Hwan-Yong
    • Journal of information and communication convergence engineering
    • /
    • v.7 no.3
    • /
    • pp.258-262
    • /
    • 2009
  • A Practical application of environmental monitoring system based on wireless sensor node network with the core of embedded system STR711FR2 microprocessor is presented in the paper. The adaptable and classifiable wireless sensor node network is used to achieve the data acquisition and multi-hop wireless communication of parameters of the monitoring base station environment including repeaters. The structure of the system is proposed and the hardware architecture of the system is designed, and the system operating procedures is proposed. As a result of field test, designed hardware platform operated with 50kbps bit rate and 5MHz channel spacing at 2040Hz. The wireless monitoring system can be managed and swiftly retreated without support of base station environmental monitoring.