• Title/Summary/Keyword: Wireless EMG

Search Result 58, Processing Time 0.023 seconds

Fabrication of Portable Self-Powered Wireless Data Transmitting and Receiving System for User Environment Monitoring (사용자 환경 모니터링을 위한 소형 자가발전 무선 데이터 송수신 시스템 개발)

  • Jang, Sunmin;Cho, Sumin;Joung, Yoonsu;Kim, Jaehyoung;Kim, Hyeonsu;Jang, Dayeon;Ra, Yoonsang;Lee, Donghan;La, Moonwoo;Choi, Dongwhi
    • Korean Chemical Engineering Research
    • /
    • v.60 no.2
    • /
    • pp.249-254
    • /
    • 2022
  • With the rapid advance of the semiconductor and Information and communication technologies, remote environment monitoring technology, which can detect and analyze surrounding environmental conditions with various types of sensors and wireless communication technologies, is also drawing attention. However, since the conventional remote environmental monitoring systems require external power supplies, it causes time and space limitations on comfortable usage. In this study, we proposed the concept of the self-powered remote environmental monitoring system by supplying the power with the levitation-electromagnetic generator (L-EMG), which is rationally designed to effectively harvest biomechanical energy in consideration of the mechanical characteristics of biomechanical energy. In this regard, the proposed L-EMG is designed to effectively respond to the external vibration with the movable center magnet considering the mechanical characteristics of the biomechanical energy, such as relatively low-frequency and high amplitude of vibration. Hence the L-EMG based on the fragile force equilibrium can generate high-quality electrical energy to supply power. Additionally, the environmental detective sensor and wireless transmission module are composed of the micro control unit (MCU) to minimize the required power for electronic device operation by applying the sleep mode, resulting in the extension of operation time. Finally, in order to maximize user convenience, a mobile phone application was built to enable easy monitoring of the surrounding environment. Thus, the proposed concept not only verifies the possibility of establishing the self-powered remote environmental monitoring system using biomechanical energy but further suggests a design guideline.

Change in Pelvic Motion Caused by Visual Biofeedback Influences Trunk and Hip Muscle Activities During Side-Lying Hip Abduction in Asymptomatic Individuals

  • Yu, Ilyoung;Kang, Minhyeok
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.10 no.3
    • /
    • pp.1818-1822
    • /
    • 2019
  • Background: Ipsilateral pelvic elevation has been reported as a common compensatory movement during side-lying hip abduction. It has been reported that pelvic elevation inhibits sufficient contraction of gluteus medius. However, few studies have identified the effects of controlled pelvic elevation on the trunk and hip muscles. Objective: To examine the effects of controlled pelvic elevation using visual biofeedback on the muscle activity of the trunk and hip muscles. Design: Crossover study. Methods: Twelve healthy males performed side-lying hip abduction exercises with and without visual biofeedback for pelvic elevation. Electromyography (EMG) activities of the gluteus medius, quadratus lumborum, and multifidus were analyzed using a wireless EMG system while the ipsilateral pelvic elevation angle was measured using a motion sensor during side-lying hip abduction exercises. Results: EMG activities of the gluteus medius (p = .002), quadratus lumborum (p = .022), and multifidus (p = .020) were significantly increased and ipsilateral pelvic elevation was significantly decreased (p = .001) during side-lying hip abduction with visual biofeedback compared to without visual biofeedback. Conclusions: The results of this study suggest that the application of biofeedback for pelvic motion could improve the trunk and hip muscle activation pattern and decrease compensatory pelvic motion during side-lying hip abduction exercise.

High Efficiency Energy Harvester by Precision Tuning (정밀 튜닝기반의 고효율 에너지 하비스터)

  • Cho, S.W.;Choi, B.G.;Son, J.D.;Yang, B.S.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.821-825
    • /
    • 2008
  • Requirements of wireless sensor are increasing in machine condition monitoring. But, the limitation of battery power, self-power wireless sensor is necessary for the purpose of stand-alone operation. To overcome this problem, energy harvester is developed by the vibration energy. The purpose of this study is to develop a high efficiency energy harvester with high precision tuning.

  • PDF

Development and Verification of Muscle Strength Effectiveness Based on Fitsig® (EMG Prototype)

  • Changjin Ji;Yong-hyun Byun;Sangho Kim
    • Journal of the Korea Society of Computer and Information
    • /
    • v.29 no.5
    • /
    • pp.111-121
    • /
    • 2024
  • With strength training comes the risk of injury and the benefits of exercise. Lack of knowledge and experience or repetitions at excessive intensity can lead to injury. Adequate feedback on an exercise's progress can increase the exercise's effectiveness and reduce injuries by providing scientific data and psychological motivation. This study aimed to validate EMG equipment and examine the effects of 8 weeks of biofeedback training with wireless electromyography. A correlation analysis between the Noraxon device and Fitsig®(EMG Prototype), a well-known instrument in the field of research, showed a moderate correlation. Statistically significant differences in humeral circumference, humeral muscle mass, and biceps and triceps strength were found between the left and right sides of the body over time, with no differences in the type of exercise. Feedback training with real-time EMG was found to be favorable for hypertrophic growth and strength improvement. Future studies should be conducted to investigate its application in sports activities further.

HandButton: Gesture Recognition of Transceiver-free Object by Using Wireless Networks

  • Zhang, Dian;Zheng, Weiling
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.10 no.2
    • /
    • pp.787-806
    • /
    • 2016
  • Traditional radio-based gesture recognition approaches usually require the target to carry a device (e.g., an EMG sensor or an accelerometer sensor). However, such requirement cannot be satisfied in many applications. For example, in smart home, users want to control the light on/off by some specific hand gesture, without finding and pressing the button especially in dark area. They will not carry any device in this scenario. To overcome this drawback, in this paper, we propose three algorithms able to recognize the target gesture (mainly the human hand gesture) without carrying any device, based on just Radio Signal Strength Indicator (RSSI). Our platform utilizes only 6 telosB sensor nodes with a very easy deployment. Experiment results show that the successful recognition radio can reach around 80% in our system.

Evaluation of Seat Pan Inclination During Sit-to-stand for Development of Elderly Lifting-chair

  • Hong, Jae-Soo;Kim, Jong-Hyun;Chun, Keyoung-Jin
    • Journal of the Ergonomics Society of Korea
    • /
    • v.30 no.2
    • /
    • pp.357-363
    • /
    • 2011
  • Objective: The aim of this study is to set the design direction of the lift chair's tilting seat for development. Background: Great attention has been shown to the development of senior friendly product, because of increasing elderly population rapidly in Korea. Therefore, we need to study on sit-to-stand(STS) motion of elderly systematically for developing lift chair that is one of senior friendly products. Method: In this study, we analyzed joint moment(knee, hip) and muscle activity (Erector spinae, Rectus femoris, Vastus lateralis) on STS motion of elderly(female, 60~70: 7) and young people(female, 20~30: 7) using 3 dimension motion capture camera, force plate, wireless EMG. Results: The results of muscle activity showed a similar trend but the results of joint moment were a lot of differences between the young and the elderly. Conclusion: The results of knee joint moment suggest the angle(10~30deg)-adjustable seat that can be better than to find the optimal seat's angle. Application: The method and results of this study are expected to develop senior friendly product and verification as well as be available to various application.

Effects of Change in the Height of Therapy Tables on the Fatigue of Splenius Capitis Muscle and Trapezius Muscle

  • Kim, Young Hoon;Noh, Ji Bin;Joo, Sung Hoon;Choi, Jung Hyun;Yoon, Jung Gyu;Lee, Sang Bin
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.4 no.1
    • /
    • pp.516-522
    • /
    • 2013
  • The purpose of this study is to analysis of muscle fatigue in the upper trapezius and splenius capitis muscles according to therapy table height variation. The subjects were consisted of 15 healthy adults(10 males, 5 females) who had no medical history of neurological and musculoskeletal problems. In experiment, wireless electrode EMG system was measured for each the upper trapezius and splenius capitis muscles during the treatment performed on table. the differences in the muscle fatigue was compared for 4 types of table height(-6cm, -3cm, 0, +3cm from elbow in $90^{\circ}$ flexion position). Muscle fatigue according to therapy table height were significant difference except for left upper trapezius. And muscle fatigue of right upper trapezius and splenius capitis showed significant decrease in +3cm table height compared to -6cm table height(p<.05). Muscle fatigue of right upper trapezius and splenius capitis were the highest in -6cm table height, but those were the lowest in +3cm table height. This study propose to change therapy table height higher than +3cm from elbow in $90^{\circ}$ flexion position, if you hope to reduce muscle fatigue.

Muscles Activation of Trunk and Lower-limb during Integrating Bridge Exercise Using Gym Ball in Healthy Individuals

  • Lee, Sue-Min;Oh, Duck-won;Son, Sung-Min
    • The Journal of Korean Physical Therapy
    • /
    • v.34 no.4
    • /
    • pp.187-191
    • /
    • 2022
  • Purpose: The purpose of our study aimed to identify the effect of static and dynamic bridge exercise with gym ball using gym ball on muscle activation of trunk and lower-limb in healthy individuals. Methods: A total of 20 healthy adults participated in this study. The individuals performed general bridge exercise, static and dynamic bridge exercise using gym ball. During the three methods of bridge exercises, electromyography (EMG) data (% maximum voluntary isometric contraction) of the rectus abdominis, erector spinae, biceps femoris, and gastrocnemius were recorded using a wireless surface EMG system. Results: Rectus abdominis activation showed significantly greater during dynamic bridge exercise compared with general bridge exercise and dynamic bridge exercise. Erector spinae, biceps femoris, and gastrocnemius were greater during static and dynamic bridge exercise compared with general bridge exercise. Conclusion: Based on our results, bridge exercise using gym ball, particularly integrating lower-limb movement, could be a useful method to enhance muscle activation of trunk and lower-limb (rectus abdominis, erector spinae, biceps femoris, and gastrocnemius).

Comparison of the Changes in the Activation of the Quadriceps Muscle based on the Plantar Flexion Degree of the Ankle Joint in Healthy Young Females during the Stand-to-Sit movement

  • Sung-Min Son
    • The Journal of Korean Physical Therapy
    • /
    • v.35 no.2
    • /
    • pp.53-57
    • /
    • 2023
  • Purpose: The purpose of this study was to compare the changes in the muscle activation of the quadriceps muscle (rectus femoris, vastus lateralis, vastus medialis) during the stand-to-sit (StandTS) movement according to the plantar flexion angle of the ankle joint. Methods: A total of 22 healthy young females participated in this study. During the StandTS under the three conditions (plantarflexion angle 0°, 20°, and 45° of the ankle), electromyography (EMG) data (% maximum voluntary iso¬metric contraction) of the rectus femoris, vastus lateralis, and vastus medialis were recorded using a wireless surface EMG system. Results: There was a significant difference in the muscle activation of rectus femoris, vastus lateralis, and vastus medialis according to the plantar flexion angle (0°, 20°, and 45°) of the ankle. The muscle activation of the quadriceps was the highest at a 45° angle of plantarflexion and the lowest at 0°. One-way repeated ANOVA was used to analyze the muscle activation data of the lower extremity muscles according to the angle of the ankle joint. Conclusion: Based on the results of our study, it was confirmed that the muscle activity of the quadriceps can be increased even in the StandTS movement, which involves the eccentric contraction of the quadriceps muscle. This suggests that maintaining a plantar flexion posture for a long time, say by wearing high-heeled shoes, can quickly cause muscle fatigue in the lower-limb muscles, which can cause a decrease in balance ability leading to falls.

Influence of Upper Trapezius and Sternocleidomastoid Muscle Activation according to Cervical Flexion Angle in Sitting Posture

  • Sung-Min Son
    • The Journal of Korean Physical Therapy
    • /
    • v.35 no.5
    • /
    • pp.151-155
    • /
    • 2023
  • Purpose: This study examined the effect of the degree of neck flexion on the muscle activity of the upper trapezius and sternocleidomastoid muscles in the sitting position. Methods: Twenty-five healthy young adults participated in this study. The study was designed to compare the muscle activity of the upper trapezius and sternocleidomastoid muscles according to the neck flexion angle under the three conditions (neutral position, 15° neck flexion, and 45° neck flexion) in the sitting position. During the neck position of three conditions in sitting, the electromyography (EMG) data (% maximum voluntary isometric contraction) of the muscles were recorded using a wireless surface EMG system. Results: The muscle activity of the upper trapezius muscle and the sternocleidomastoid muscles showed a significant difference according to the three-neck position conditions (p<0.05), and in the post-hoc test results, both muscles showed significant differences between the neutral position and 15° flexion, the neutral position and 45° flexion, and the 15° flexion and 45° flexion, respectively. Conclusion: The load on the muscles around the neck and shoulders increased as the neck flexion angle increased. This suggests that performing various daily activities and tasks with the neck as neutral as possible can prevent muscle fatigue or musculoskeletal disorders.