A Study on Development of Wireless Check-up Device for Captive Flight Test (탑재비행시험용 무선 점검장치 개발에 대한 연구)

  • Ryu, Sang-Gyu;Joo, Junghyun;Ko, Myoungjun
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.22 no.4
    • /
    • pp.501-508
    • /
    • 2019
  • In this paper, a study on a wireless check-up method of test equipment for captive flight test(CFT) was conducted. For CFT, test equipment is mounted on a POD, and check-up is carried on the test equipment's. For check-up the POD wirelessly, battery, power distribution unit, wireless communication devices were designed within the POD, and a check-up device is designed outside of the POD. Once the external check-up device sends a 'start signal' to the POD, it performs the overall check-up procedures and transmits the 'end signal' to the external check-up device. Detailed check-up results are stored in an internal storage device, and are possible to read from external check-up device if necessary, thereby improving the reliability of the wireless check-up. By implementing and applying these wireless check-up system, the reliability of the check-up was enhanced by dynamical and movable check-up, and safety is guaranteed as the check-up was carried without access to the aircraft.

Development and Verification of Wireless Check-up System of POD for Captive Flight Test (탑재비행시험용 POD 무선 점검 시스템 개발 및 검증)

  • Ko, Myoungjun
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.24 no.2
    • /
    • pp.204-210
    • /
    • 2021
  • In this paper, we studied a method of wirelessly checking up the POD for captive flight tests which is performed during the development of guided weapons systems. The wireless power transfer module, the power distribution device, and the battery pack were designed to wirelessly power the captive flight test POD, and the communication device was designed to enable wireless communication between the POD and the check-up device. The communication device was designed to enable WiFi, IR communication, and laser diode communication, so that various communication methods could be tested. Through the performance test, it was confirmed that power was stably supplied to the captive flight test POD, and the wireless communication performance was verified by measuring the delay time and error rate. As a result, by using our system the POD check-up for the captive flight test was performed wirelessly and the data of the captive equipment could be obtained effectively.

Power Consumption Analysis of Asynchronous RIT mode MAC in Wi-SUN (Wi-SUN에서 비동기 RIT 모드 MAC의 전력소모 분석)

  • Dongwon Kim
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.23 no.4
    • /
    • pp.23-28
    • /
    • 2023
  • In a wireless smart utility network communication system, an asynchronous low power MAC is standardized and used according to IEEE 802.15.4e. An asynchronous MAC called RIT (Receiver Initiated Transmission) has a characteristic in which delay time and power consumption are greatly affected by a check-in interval (RIT period). By waking up from sleep every check-in interval and checking whether there is data to be received, power consumption in the receiving end can be drastically reduced, but power consumption in the transmitting end occurs due to an excessive wakeup sequence. If an excessive wake-up sequence is reduced by shortening the check interval, power consumption of the receiving end increases due to too frequent wake-up. In the RIT asynchronous MAC technique, power consumption performance according to traffic load and operation of check-in interval is analyzed and applied to Wi-SUN construction.

Mobile-type blood gas analysis system for data transmission system (이동형 혈액가스분석기의 데이터 전송시스템)

  • Kang Sung-Chul;Kim Gi-Ryon;Jung Dong-Keun;Jeong Do-Un;Jeon Gye-Rok
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2006.05a
    • /
    • pp.1027-1031
    • /
    • 2006
  • Recently, mobile-type analysis system when emergency patient can check his blood condition in the transportation or vessel has being required. Under the present system, it takes lots off-time to know the blood analysis result of patient, so, it may lead to a dangerous situation. But, in this study, analysis time makes to fall down to $1{\sim}min$. to emergency treatment patient more quickly, and you can check the information by wireless PC through Bluetooth base. It is able to measure in about 7minutes from 25minutes of warming-up time in existing facilities by testing temperature peculiarity curve, to operate system without error even minute temperature change by adoption DUAL heating. And Bluetooth base was adopted to reduce power consumption and be able to hospital networking by keeping and sending analyzed data when it needs.

  • PDF

Mobile Ubiquitous Healthcare System Using Wireless Sensor Network (무선센서네트워크 기반의 모바일 유비쿼터스 헬스케어시스템)

  • Shin, Kwang-Sig;Yau, Chiew-Lian;Chung, Wan-Young
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.11
    • /
    • pp.2107-2112
    • /
    • 2006
  • As growing up of elderly population, the interesting on healthcare system in normal life using W is increasing. An integrated u-healthcare service architecture with IEEE 802.11 and IEEE 802.15.4 based sensor network and code divisi(m multiple access(CDMA) public mobile telecommunication networks was designed and developed. Sensor nodes with electrocardiogram(ECG), body core temperature sensors are attached on the patients' body. The healthcare parameters are transferred to web server via CDMA mobile network or through existed LAN network. The existed LAN network is suggested to be used for continuous monitoring of patient's health status in hospital while mobile networks can be used for general purpose at home or outdoor where infra networks unavailable. This system enable healthcare personal to be able to continuously access, review, monitor and transmit the patients information whereever they are, whenever they want. And immediately check their status by using cellular phone and obtain detail information by communication with medical information server through CDMA. By using this developed integrated u-healthcare service architecture, we can monitor patients' health status for 24 hours.

Auto Dispatch Device of Parturition Beginning Signal by Temperature and a Load Sensor at Ubiquitous Circumstance in Pig Industry (양돈산업에 있어서 유비쿼터스 환경에서 온도 및 하중 센서에 의한 자동 분만 알림 시스템 개발)

  • Lee, Jang-Hee;Baek, Soon-Hwa;Yon, Seung-Ho
    • Reproductive and Developmental Biology
    • /
    • v.33 no.3
    • /
    • pp.139-146
    • /
    • 2009
  • This study tried to develop the system (device) that automatically notify a manager of condition just before and after farrowing to extend ubiquitous-based technology and to increase efficiency of delivery care and productivity by reducing human labor and time on standby when farrowing management is done in the difficult and hard working environment of farrowing such as night or holidays in field sand especially in pig industry. In this test, selected 10 gilts were executed timed artificial insemination and were set up each temperature sensor and load sensor to them 3 days before the estimated farrowing day and were observed the farrowing situation. This study was embodied the NESPOT-based (KT Corporation) monitoring system, the system to transmit data in real time by utilization of wireless LAN and the sensor module to apply the ubiquitous environment to them. And this study was observed the situation to automatically notify situations of 10 gilts that first bore just before and after farrowing. The result obtained the farrowing situations of them in real time by setup of the NESPOT-based monitoring system to check farrowing situation directly is as follow. The average time of the automatic notice about situation just before farrowing by the temperature sensor was 27.5 minutes before the beginning of farrowing (the expulsion time of a piglet). 6 of 8 pregnant gilts that first bore automatically were notified situations just before farrowing and the temperature sensors inserted into 2 ones before farrowing were omitted. (The automatic notice rate 75%) The average time of the automatic notice of situation just after farrowing by the load sensor was taken 46.5 minutes after the beginning of farrowing (the expulsion time of a first piglet). The average gestation period of 8 ones that first bore and were tested by the automatic notice of farrowing situation was 115.6 days. This result found that the automatic farrowing notice system by the temperature sensor is more efficient than the load sensor as the automatic farrowing alarm device and sanitary treatment and improvement of the omission rate were required.

A Power Control Algorithm for Performance Enhancement in Femtocell Systems (펨토셀 시스템 용량 개선을 위한 전력 제어 알고리즘)

  • Jung, Jae-Hwan;Sohn, Insoo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.41 no.9
    • /
    • pp.1020-1025
    • /
    • 2016
  • In the recent, the communication market increased every year. Because of the user's demands and exhaustion of wireless resource, we needs a new technology of the communication system. The femtocell is one of the new technology of the communication system. 'Femto' means very small. By using the femtocell that made up the very small cell, the frequency efficiency increase. The femtocell has different cell environments. The Power Control is important for femtocell to avoid interference and unnecessary handover. In this paper, we propose a new femtocell power control that is improvement of handover probability and throughput. And we simulate and check the result.