• Title/Summary/Keyword: Wire-to-wire Electrode

Search Result 199, Processing Time 0.032 seconds

Coated Wire Lead(Ⅱ) Ion-Selective Electrodes based on Crown Ethers (Crown Ether를 이용한 탐침형 납 이온선택성 전극)

  • Jang, Mi Kyeong;Ha, Kwang Soo;Seo, Moo Lyong
    • Journal of the Korean Chemical Society
    • /
    • v.41 no.7
    • /
    • pp.337-342
    • /
    • 1997
  • Acryloylmethylbenzo-15-crown-5 was prepared from the reaction of 4'-hydroxymethylbenzo-15-crown-5 with acryloyl chloride. And, poly(acryloylmethylbenzo-15-crown-5) [poly(AMB15C5)] was synthesized by radical polymerization using AIBN as initiator in benzene. Coated wire lead(II) ion-selective electrodes ($Pb^{2+}$-CWISEs) using either poly(AMB15C5) or B15C5 as neutral carrier were prepared, respectively. $Pb^{2+}$-CWISEs gave linear responses with slopes of 28$\pm$ 1mV per decade within the concentration range of $10^{-5} M{\sim}10^{-1}$ M, respectively. Also, the detection limits were $10^{-6}$ M and response times were either 3 or 5 min. for B15C5 and poly(AMB15C5), respectively. $Pb^{2+}$-CWISE base on B15C5 was rather unstable than poly(AMB15C5)'s due to solubility of the B15C5 in water. The selectivity coefficients of a variety of interfering ions such as $Mg^{2+},\; Ca^{2+},\; Co^{2+},\; Ni^{2+},\; Cu^{2+},\; Zn^{2+}$ and $Cd^{2+}$ were small ($10^{-4}{\sim}10^{-5}$), while those of $Na^+$ and $K^+$ were large (0.1∼0.01). In addition, the electrode responses depended upon the pH of test solution and the composition of the membrane. In the range pH 3∼6 of test solution, potentials of Pb2+-CWISEs were hardly changed. The optimal contents of B15C5 and poly(AMB15C5) were 7.7 wt% and 13.1 wt%, respectively.

  • PDF

Electrochemical Properties of Langmuir-Blodgett Films of 4-Octyl-4'-(5-carboxy-pentamethylene-oxy)azobenzene and Dilauroyl-L-${\alpha}$-Phosphayidylcholine Mixture (4-Octyl-4'-(5-carboxy-pentamethylene-oxy)azobenzene과 Dilauroyl-L-${\alpha}$- Phosphayidylcholine의 혼합 LB막의 전기화학적 특성)

  • Kim, Beom-Joon;Min, Byoung-Chul;Park, Keun-Ho
    • Journal of the Korean Applied Science and Technology
    • /
    • v.19 no.1
    • /
    • pp.49-55
    • /
    • 2002
  • We carried out this experiment to observe electrochemical properties for LB films of phospholipid(Dilauroyl-L-${\alpha}$-Phosphayidylcholine) and 4-octyl-4'-(5-carboxypentamethylene-oxy)azobenzene mixture by the cyclic voltammetry. LB films of 8A5H and 8A5H-DLPC(1:1, 2:1) were deposited by using the Langmuir-Blodgett method on the ITO glass. We determined electrochemical measurement by using cyclic voltammetry with a three-electrode system, An Ag/AgCl reference elect rode, a platinum wire counter electrode and LB film-coated ITO working electrode measured in 0.1, 0.5, and 1.0 mol/L $NaClO_{4}$ solution. A measuring range was reduced from initial potential to -1350 mV, continuously oxidized to 1650 mV and measured to the initial point. The scan rate were 50, 100, 150 and 200 mV/s. As a result, LB films of 8A5H 8A5H-DLPC appeared irreversible process caused by only the oxidation current from the cyclic voltammogram.

An Electrochemical Approach for Fabricating Organic Thin Film Photoelectrodes Consisting of Gold Nanoparticles and Polythiophene

  • Takahashi, Yukina;Umino, Hidehisa;Taura, Sakiko;Yamada, Sunao
    • Rapid Communication in Photoscience
    • /
    • v.2 no.3
    • /
    • pp.79-81
    • /
    • 2013
  • A novel method of fabricating polythiophene-gold nanoparticle composite film electrodes for photoelectric conversion is demonstrated. The method includes electrodeposition of gold and electropolymerization of 2,2'-bithiophene onto an indium-tin-oxide (ITO) electrode. First, electrodeposition of gold onto the ITO electrode was carried out with various repetition times of pulsed applied potential (0.25 s at -2.0 V vs. Ag/AgCl) in an aqueous solution of $HAuCl_4$. Significant progress of the number density of deposited gold nanoparticles was confirmed from scanning electron micrographs, from 4 (1 time) to 25% (15 times). Next, electropolymerization of 2,2'-bithiophene onto the above ITO electrode was performed under controlled charge condition (+1.4 V vs. Ag wire, 15 $mC/cm^2$). Structural characterization of as-fabricated films were carried out by spectroscopic and electron micrographic methods. Photocurrent responses from the sample film electrodes were investigated in the presence of electron acceptors (methyl viologen and oxygen). Photocurrent intensities increased with increasing the density of deposited gold nanoparticles up to ~10%, and tended to decrease above it. It suggests that the surplus gold nanoparticles exhibit quenching effects rather than enhancement effects based on localized electric fields induced by surface plasmon resonance of the deposited gold nanoparticles.

Construction and Optimization of Selective Membrane Electrodes for Determination of Doxepin Hydrochloride in Pharmaceutical Preparations and Biological Fluids (약의 조제와 생물학적 유체에서 독스핀 하이드로클로라이드의 확인을 위한 선택적 막 전극의 구성과 최적화)

  • El-Tohamy, Maha;Razeq, Sawsan;El-Maamly, Magda;Shalaby, Abdalla
    • Journal of the Korean Chemical Society
    • /
    • v.54 no.2
    • /
    • pp.198-207
    • /
    • 2010
  • The construction and performance characteristics of doxepin hydrochloride selective electrodes were developed. Three types of electrodes: plastic membrane I, coated wire II, and coated graphite rod III were constructed based on the incorporation of doxepin hydrochloride with ammonium reineckate. The influence of membrane composition, kind of plasticizer, pH of the test solution, soaking time, and foreign ions on the electrodes was investigated. The electrodes showed a Nernstain response with a mean slope of 57.41 ${\pm}$ 0.5, 56.22 ${\pm}$ 0.2 and 52.88 ${\pm}$ 0.7 mV at $25^{\circ}C$ for electrode I, II and III respectively, over Doxepin hydrochloride concentration range from $1{\times}10^{-2}-1{\times}10^{-6}M$, $5{\tims}10^{-2}-1{\times}10^{-6}M$ and $1{\times}10^{-3}-5{\times}10^{-6}M$, and with a detection limit $5.0{\times}10^{-7}M$, $6.3{\times}10^{-7}M$ and $2.5{\times}10^{-6}M$ for electrode I, II and III respectively. The constructed electrodes gave average selective precise and usable within the pH range 3 - 7. Interferences from common cations, alkaloids, sugars, amino acids and drug excipients were reported. The results obtained by the proposed electrodes were also applied successfully to the determination of the drug in pharmaceutical preparations and biological fluids.

Particle removal characteristics of high-velocity electrostatic mist eliminator (정전 고속 미스트 엘리미네이터의 포집 효율 특성)

  • Kim, Jin-seon;Kim, Hak-Joon;Han, Bangwoo;Woo, Chang Gyu;Kim, Yong-Jin;Lee, Sangrin;Moon, Sangchul
    • Particle and aerosol research
    • /
    • v.14 no.4
    • /
    • pp.121-133
    • /
    • 2018
  • In this study, we developed a flat-plate type wet electrostatic precipitator that generates stable corona discharge compared to wire type discharge electrode. In order to compare the particle removal efficiency according to the shape of the discharge electrode such as the variation of the horizontal and vertical distance between spiked edges, and the variation of the height of discharge pin support were tested. As a result, when the horizontal distance between spiked edges was increased up to 36 mm, the vertical distance between spiked edges was increased up to 54 mm, and the height of the discharge pin support was increased up to 76 mm, the removal efficiency of PM10 was maintained at approximate 60.0%. Furthermore, the removal efficiency of particles over $5{\mu}m$ was about 80% or more. When the flow rate was 4 m/s, the gap between collection plates was 60 mm, and -14 kV was applied to the discharge electrode. The particle removal efficiency of the flat-plate type electrostatic precipitator was maintained when the horizontal and vertical distance between spiked edges, and the height of the discharge pin support was below a certain level. Those variables may be the important design factors for the shape of the discharge electrode. Therefore, when designing the electrostatic precipitator with multiple channels, the horizontal and vertical distance between spiked edges, and the height of discharge pin support must be selected in consideration of the weight of the discharge electrode and the processing cost.

Development of Ozone Generator with using DC Voltage for Swinery (돈사 적용용 DC전압을 이용한 오존발생장치 개발에 관한 연구)

  • 문승일;채재우;이대엽;장기현;정태균
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.19 no.1
    • /
    • pp.77-84
    • /
    • 2003
  • HS, Ammonia, CH$_4$, VOCs, Microorganism, Bacteria etc produced from swineries or henhouses are known to prevent the growth of livestock. Moreover, they give an unpleasant feeling to the workers. In this study, a methodology to remove odors and toxic gases by oxidation of ozone was thus accomplished. However, most ozone generators which use the atmospheric surrounding air have problems of contamination of electrode for discharge. Therefore in this work, a wire-cylinder type plasma reactor with DC voltage has been used both in a laboratory scale test and in the real swinery to solve the existing problems. About 6 cm of electrode gap could decrease the attachment of dusts, humid aerosols and other polymers, which are contained in the air. This compact designed device could produce ozone to oxidize and remove the air pollutants. But the amount of ozone was not large enough to be harmful to human Health. Also, the concentration of ozone was able to be varied by the input voltage. which makes it available for the proposed system to be installed in various kinds of pig houses. With this device, at maximum 43 mg/㎥ (20 ppm) of ozone could be produced at 40 ㎸ input voltage (consumed energy was 0.1 Wh/㎥). A program was also made in this work to calculate the optimum parameters for design of a plasma reactor in wide range of conditions.

A Study on the Improvement on the Target Structure in a Magnetron Sputtering Apparatus (마그네트론 스퍼터링 장치의 타겟구조 개선에 관한 연구)

  • Bae, Chang-Hwan;Lee, Ju-Hee;Han, Chang-Suk
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.23 no.1
    • /
    • pp.23-28
    • /
    • 2010
  • The cylindrical magnetron sputtering has not been widely used, although this system is useful for only certain types of applications such as fiber coatings. This paper presents electrode configurations which improved the complicacy of the target assembly by using the positive voltage power supply. It is a modified type which has a target constructed with a large cylindrical part, a conical part and a small cylindrical part. When positive voltage was applied to an anode, a stable glow discharge was established and a high deposition rate was obtained. The substrate bias current was monitored to estimate the effect of ion bombardment. As a result, it was found that the substrate current was large. With cylindrical and conical cathode magnetron sputter deposition on the surface of the substrate to prevent re-sputtering, ion impact because it can increase the effectiveness with excellent ductility and adhesion of Ti film deposition can be obtained. We board at the front end of the ground resistance of $5\;k{\Omega}$ attached to the substrate potential can be controlled easily, and Ti film deposition with excellent adhesion can be obtained. Microstructure and morphology of Ti films deposited on pure Cu wires were investigated by scanning electron microscopy in relation to preparation conditions. High level ion bombardment was found to be effective in obtaining a good adhesion for Cu wire coatings.

Degradation of synthetic dye in water by solution plasma process

  • Panomsuwan, Gasidit;Morishita, Tetsunori;Kang, Jun;Rujiravanit, Ratana;Ueno, Tomonaga;Saito, Nagahiro
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.10
    • /
    • pp.888-893
    • /
    • 2016
  • In this study, the solution plasma process was utilized with the aim of degrading synthetic dyes in water at atmospheric pressure. The experiments were conducted in a batch-type reactor consisting of a symmetric wire-wire electrode configuration with rhodamine B (RhB) as the target synthetic dye. The effects of the plasma treatment time and initial dye concentration on the RhB degradation were investigated by monitoring the change in absorbance of RhB solutions. The RhB solutions turned lighter in color and finally colorless with prolonged plasma treatment time, indicating the destruction of dye molecules. The RhB solutions were found to have degraded, following the first-order kinetic process. However, for high initial RhB concentrations, another kinetic process or factor seems to play a dominant role at the initial degradation stage. The fitted first-order rate constant decreased as the initial concentration increased. This result suggests that the degradation behavior and kinetic process of the RhB solution strongly depends on its initial concentration. The RhB degradation is considered to be due to a combination of factors, including the formation of chemically oxidative species, as well as the emission of intense UV radiation and high-energy electrons from the plasma. We believe that the solution plasma process may prove to be an effective and environment-friendly method for the degradation or remediation of synthetic dye in wastewater.

New Micro Rotating Mercury Electrode for Voltammetry (전류전압법을 위한 미크로 회전수은 전극)

  • Choe, Gyu-Won
    • Journal of the Korean Chemical Society
    • /
    • v.11 no.3
    • /
    • pp.81-84
    • /
    • 1967
  • A simple rotating micro mercury electrode is constructed in such a way that the mercury surface can be renewed quite easily with reasonable reproducibility. It consists of a glass capillary of about 1mm diameter connected to a mercury filled tube by means of a ground joint that allows mercury flow at a particular relative position only, and the electrical connection between the two parts is made by a platinum wire fused in the bottom of the latter. Thus the mercury surface exposed at the tip of the capillary replaces the platinum tip of the usual platinum micro electrode; however, the capillary has to be bent so that the tip directs upwards. It has been found to be a convenient electrode in the amperometric titration in strongly acidic media. Furthermore, it has been advantageously used in the alternating-current polarography because of its smaller electrical resistance than the ordinary dropping mercury electrodes. It also can be used as a stationary mercury electrode in fast scanning polarography.

  • PDF

Development of Retinal Prosthesis Module for Fully Implantable Retinal Prosthesis (완전삽입형 인공망막 구현을 위한 인공망막모듈 개발)

  • Lee, Kang-Wook;Kaiho, Yoshiyuki;Fukushima, Takafumi;Tanaka, Tetsu;Koyanagi, Mitsumasa
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.4
    • /
    • pp.292-301
    • /
    • 2010
  • To restore visual sensation of blind patients, we have proposed a fully implantable retinal prosthesis comprising an three dimensionally (3D) stacked retinal chip for transforming optical signal to electrical signal, a flexible cable with stimulus electrode array for stimulating retina cells, and coupling coils for power transmission. The 3D stacked retinal chip is consisted of several LSI chips such as photodetector, signal processing circuit, and stimulus current generator. They are vertically stacked and electrically connected using 3D integration technology. Our retinal prosthesis has a small size and lightweight with high resolution, therefore it could increase the patients` quality of life (QOL). For realizing the fully implantable retinal prosthesis, we developed a retinal prosthesis module comprising a retinal prosthesis chip and a flexible cable with stimulus electrode array for generating optimal stimulus current. In this study, we used a 2D retinal chip as a prototype retinal prosthesis chip. We fabricated the polymide-based flexible cable of $20{\mu}m$ thickness where 16 channels Pt stimulus electrode array was formed in the cable. Pt electrode has an impedance of $9.9k{\Omega}$ at 400Hz frequency. The retinal prosthesis chip was mounted on the flexible cable by an epoxy and electrically connected by Au wire. The retinal prosthesis chip was cappted by a silicone to pretect from corrosive environments in an eyeball. Then, the fabricated retinal prosthesis module was implanted into an eyeball of a rabbit. We successfully recorded electrically evoked potential (EEP) elicited from the rabbit brain by the current stimulation supplied from the implanted retinal prosthesis module. EEP amplitude was increased linearly with illumination intensity and irradiation time of incident light. The retinal prosthesis chip was well functioned after implanting into the eyeball of the rabbit.