• Title/Summary/Keyword: Wire-line Communication

검색결과 95건 처리시간 0.023초

전력간선에서의 전자파 장애를 고려한 원칩형 누설전류 원격 검출단말기의 개발 (An Development of Leakage Current Sensing Module of the System on Chip Type Under Consideration of Electromagnetic Interface in Power Trunk Line)

  • 김동완;박지호;박성원
    • 전기학회논문지P
    • /
    • 제58권4호
    • /
    • pp.377-384
    • /
    • 2009
  • In this paper, leakage current sensing module of SoC(System on Chip)type and real time monitoring system under consideration of electromagnetic interface in power trunk line are developed. The first, leakage current sensing module of SoC type under consideration of electromagnetic interface is developed, and the developed sensing module of SoC type is composed of leakage sensing part, power supply part, interface part, communication part, AD(Alternating current to Direct current)convert part and amplification part. And also the electromagnetic compatibility is evaluated by conduction and radiation of EMI(Electromagnetic Interference) for developed sensing module. The developed system can have confidence, stability and do energy saving under mixed electric circumstance of the low voltage communication device and high voltage equipment. The second, the real time remote monitoring system is developed using designed wire and wireless communication module with leakage current sensing module of SoC type. The developed real time remote monitoring system can monitor sensing state, occurrence state of leakage current and alarm for each step etc.. And the device configuration, PCB layout for leakage current sensing module of system on chip type and the experiment configuration in consideration of EMI are presented. Also the measurement results of conduction and radiation for EMI are presented.

송전선로 가선공사용 모듈형 발받침 개발 (Development of Modular Scaffold for Overhead Transmission Line Wiring Work)

  • 민병욱;백승도;강대언;방항권;최진성;백수곤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.450-451
    • /
    • 2006
  • The method of conductor wiring is that a messenger wire is installed, the end of the wire is connected to the conductor and a engine puller pulls the conductor. The length of one section of wiring is $3{\sim}5km$ and one group messenger wire pulls simultaneously $2{\sim}4$ group conductor, while a tensioner maintains wiring tension to prevent the deflection of the conductor. However, there are many obstacles such as roads, power lines, communication lines, buildings, farms and crops. Therefore to prevent damage from conductor deflection a staging is used. The currently used staging is scaffolding lumber which is difficult to secure and it's construction efficiency is very low because it requires a lot of time and manpower. So this study developed a insulating defense tube and pipe connecting device, and a truss structure fabrication module using steel pipe which reduces construction time and cost through a compressive and dielectric strength test.

  • PDF

가공 배전선로 진단시스템 프로그램 개발 (Development of overhead distribution line diagnosis system program)

  • 정동현;이덕진
    • 스마트미디어저널
    • /
    • 제12권5호
    • /
    • pp.81-87
    • /
    • 2023
  • 전력계통에서 안정적인 전력공급을 하는 고압 가공 배전선로의 사고 발생으로 생활의 불편과 더불어 기업의 생산 차질을 초래하게 된다. 22.9[kV] 고압 가공 배전선은 평소 비, 눈, 바람 등에 의한 피해나 감전방지 등의 신뢰성 및 안정성의 향상을 목적으로 하고 있다. 이에 가공 배전선로의 부식으로 인한 전선의 도전율을 저하시키거나 인장강도가 저하되어 단선 사고를 미연에 방지하기 위하여 평소에 점검과 보수를 통하여 미래의 예기치 못한 사고를 미리 방지하여야 한다. 배전선로의 부식으로 인한 열화진단을 하기 위하여 전선에 진단시스템(계측기)를 설치하여 전선의 상태를 모니터링한다. 측정된 데이터를 ZigBee 무선통신으로 지상의 관리자가 받아 진단시스템 프로그램을 통하여 진단시스템의 제어와 측정된 데이터 및 촬영된 사진을 통하여 가공 배전선로의 상태를 파악하여 육안 검사 방법과 더불어 전선의 수명을 예측하는 프로그램을 개발하였다.

전화선 통신 시스템의 전송특성 및 채널용량에 관한 연구 (A Study on the Transmission Characteristics and Channel Capacity of Telephone Line Communication System)

  • 노재성;장태화
    • 디지털콘텐츠학회 논문지
    • /
    • 제10권2호
    • /
    • pp.233-238
    • /
    • 2009
  • 디지털 통신 네트워크 기술의 발전에서 인터넷 기술과 스마트 홈 가전기기의 확산은 고속/고품질 홈 네트워크에 대한 필요성을 증가시키고 있다. 홈 네트워크에서 가전기기와 컴퓨팅 기기가 증가함에 따라 홈 네트워크의 데이터 트래픽은 증가할 것이 명백하다. 다양한 홈 네트워크 기기는 멀티미디어 콘텐츠를 얻기 위하여 인터넷 서버에 접속하길 원한다. 따라서 본 논문에서는 가정내에서 이더넷이나 유무선 기술을 사용하기 위해 네트워크에 연결된 디지털 가전기기를 위한 TLC(Telephone Line Carrier) 시스템을 소개한다. 미래의 홈 네트워크 환경에서 TLC 기반의 스마트 홈 네트워크의 주된 목적은 저가격, 쉬운 설치, 고성능, 넓은 영역을 만드는 것이다. 본 논문에서는 스마트 홈 네트워크를 위한 전화선로 통신시스템의 채널용량을 송신전력, OFDM 반송파의 수, 채널손실, 잡음손실에 따라서 정량적으로 비교, 분석하였다.

  • PDF

An Estimation of a Billet Temperature during Reheating Furnace Operation

  • Jang, Yu-Jin;Kim, Sang-Woo
    • International Journal of Control, Automation, and Systems
    • /
    • 제5권1호
    • /
    • pp.43-50
    • /
    • 2007
  • Reheating furnace is an essential facility of a rod mill plant where a billet is heated to the required rolling temperature so that it can be milled to produce wire. Although it is very important to obtain information on billet temperatures, it is not feasible during furnace operation. Consequently, a billet temperature profile should be estimated. Moreover, this estimation should be done within an appropriate time interval for an on-line application. In this paper, a billet heat transfer model based on 2D FEM(Finite Element Method) with spatially distributed emission factors is proposed for an on-line billet temperature estimation and also a measurement is carried out for two extremely different furnace operation patterns. Finally, the difference between the model outputs and the measurements is minimized by using a new optimization algorithm named uDEAS(Univariate Dynamic Encoding Algorithm for Searches) with multi-step tuning strategy. The obtained emission factors are applied to a simulation for the data which are not used in the model tuning for validation.

지하 생활공간 환경제어 설비 통합관리 기술 (Integrated management technology of environmental control facilities underground living space)

  • 강현근;김태한;전진한;이승홍
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.95-98
    • /
    • 2008
  • A power line communications, power, the outgoing line is a means of communication. DC 12 volt power lines in the system over the 2-wire control signals with the power to send the cargo configuration, and, in the basement living space, temperature, humidity, dust, CO2 sensors, and through the cooperation of the real-time detection and valves of the appropriate amount of wind, fan was designed to control. By the system's ability to communicate and control the room temperature or the status of amount of wind sent to the central system to transmit and receive signals to the center of the future, the ability to control the company said. In addition, the system HMI (Human Machine Interface) terminal by the direct control and if necessary personal portable devices to communicate with the living conditions of the underground environment in the best state that the purpose is to build.

  • PDF

가공 배전선로 장주의 중성선 전류 계산 (Neutral Current Calculation of Pole-Top Overhead Distribution Line)

  • 서훈철;권오상;김철환;정창수;유연표
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제55권7호
    • /
    • pp.290-296
    • /
    • 2006
  • If the three phases are not balanced, the current in neutral wire is not zero. Then, the induced voltage can be generated in communication line. The KEPCO's rule about unbalanced current for one step type in distribution pole is a twenty percent of phase current. But the unbalanced current for two step type in distribution pole can't decide the rule because there are many different views. This paper presents the calculation and analysis technique of neutral current in distribution poles using equivalent circuit analysis and EMTP simulation.

모바일 GIS를 이용한 Point 및 Line형 데이터 갱신 방법에 관한 연구 (A Study on Management Method of Point and Line Data Using Mobile GIS)

  • 전재용;조기성
    • 대한공간정보학회지
    • /
    • 제15권3호
    • /
    • pp.3-10
    • /
    • 2007
  • 정보통신 기술의 발전에 따라 GIS는 유선 GIS에서 모바일 GIS로 발전되어 가고 있는 추세이다. 이는 모바일 GIS를 통해 이동성, 현장성, 신속성, 적시성 등을 만족시키고 공간 및 속성자료를 현장에서 조사 및 확인, 입력 및 수정등의 작업을 수행할 수 있는데 적합하기 때문이다. 이와 같은 모바일 GIS의 이용은 도시 내 각종 시설물들에 대한 유지관리를 효과적으로 수행하기 위한 최선의 방법일 것이라 사료된다. 본 연구에서는 해당 시설물의 담당자가 좀 더 손쉽고 효율적인 방법으로 각종 시설물을 유지관리 할 수 있도록 Point 및 Line형 데이터를 갱신할 수 있는 방법을 제시하였다. Point형 데이터의 갱신방법으로는 임의법, 지거법, 이점법을 제시하였고, Line형 데이터의 갱신 방법으로는 임의법, 점-점 연결법, 점-선 연결법, 점-선 최소거리 연결법을 제시하였다.

  • PDF

고속 전력선 통신을 위한 중전압 선로의 방사전자파 측정 및 분석 (Emissive Electromagnetic Field Measurement and Analysis for High Speed PLC on Medium Voltage Power-Line Channel)

  • 김선효;김상태;이영철;신철재
    • 한국전자파학회논문지
    • /
    • 제14권1호
    • /
    • pp.54-61
    • /
    • 2003
  • 본 논문은 중 전압 전력선(22.9 kV)에서 방사되는 전자파 특성결과를 보여주고 있다. 측정은 주파수범위 9 kHz∼30 MHz의 통신 신호를 중 전압 전력선로에 인가하였을 때 측정을 하였다. 측정결과 단일 반송신호보다 다중 반송신호에서 방사되는 전자파의 특성이 우수하며 다중반송신호의 세기가 20 dBm일 때 전력선 통신 신호는 1.8 km까지 전송 가능함을 알 수가 있었다. 전기장의 세기는 10 m 법으로 측정하였을 때 30 MHz에서 40 dBuV/m이하의 값을 볼 수가 있었다.

A System-in-Package (SiP) Integration of a 62GHz Transmitter for MM-wave Communication Terminals Applications

  • Lee, Young-Chul;Park, Chul-Soon
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제4권3호
    • /
    • pp.182-188
    • /
    • 2004
  • We demonstrate a $2.1\;{\times}\;1.0\;{\times}\;0.1cm^3$ sized compact transmitter using LTCC System-in-Package (SiP) technology for 60GHz-band wireless communication applications. For low-attenuation characteristics and resonance suppression of the SiP, we have proposed and demonstrated a coplanar double wire-bond transition and novel CPW-to-stripline transition integrating air-cavities as well as novel air-cavities embedded CPW line. The fabricated transmitter achieves an output of 13dBm at a RF frequency of 62GHz, an IF frequency of 2.4GHz, and a LO frequency of 59.6GHz. The up-conversion gain is 11dB, while the LO signal is suppressed with the image rejection mixer below -21.4dBc, and the image and spurious signals are also suppressed below -31dBc.