• Title/Summary/Keyword: Wire-line Communication

Search Result 95, Processing Time 0.032 seconds

An Development of Leakage Current Sensing Module of the System on Chip Type Under Consideration of Electromagnetic Interface in Power Trunk Line (전력간선에서의 전자파 장애를 고려한 원칩형 누설전류 원격 검출단말기의 개발)

  • Kim, Dong-Wan;Park, Ji-Ho;Park, Sung-Won
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.4
    • /
    • pp.377-384
    • /
    • 2009
  • In this paper, leakage current sensing module of SoC(System on Chip)type and real time monitoring system under consideration of electromagnetic interface in power trunk line are developed. The first, leakage current sensing module of SoC type under consideration of electromagnetic interface is developed, and the developed sensing module of SoC type is composed of leakage sensing part, power supply part, interface part, communication part, AD(Alternating current to Direct current)convert part and amplification part. And also the electromagnetic compatibility is evaluated by conduction and radiation of EMI(Electromagnetic Interference) for developed sensing module. The developed system can have confidence, stability and do energy saving under mixed electric circumstance of the low voltage communication device and high voltage equipment. The second, the real time remote monitoring system is developed using designed wire and wireless communication module with leakage current sensing module of SoC type. The developed real time remote monitoring system can monitor sensing state, occurrence state of leakage current and alarm for each step etc.. And the device configuration, PCB layout for leakage current sensing module of system on chip type and the experiment configuration in consideration of EMI are presented. Also the measurement results of conduction and radiation for EMI are presented.

Development of Modular Scaffold for Overhead Transmission Line Wiring Work (송전선로 가선공사용 모듈형 발받침 개발)

  • Min, Byeong-Wook;Baik, Seung-Do;Kang, Dae-Eon;Bang, Hang-Kwon;Choi, Jin-Sung;Baek, Soo-Gon
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.450-451
    • /
    • 2006
  • The method of conductor wiring is that a messenger wire is installed, the end of the wire is connected to the conductor and a engine puller pulls the conductor. The length of one section of wiring is $3{\sim}5km$ and one group messenger wire pulls simultaneously $2{\sim}4$ group conductor, while a tensioner maintains wiring tension to prevent the deflection of the conductor. However, there are many obstacles such as roads, power lines, communication lines, buildings, farms and crops. Therefore to prevent damage from conductor deflection a staging is used. The currently used staging is scaffolding lumber which is difficult to secure and it's construction efficiency is very low because it requires a lot of time and manpower. So this study developed a insulating defense tube and pipe connecting device, and a truss structure fabrication module using steel pipe which reduces construction time and cost through a compressive and dielectric strength test.

  • PDF

Development of overhead distribution line diagnosis system program (가공 배전선로 진단시스템 프로그램 개발)

  • Dong Hyun Chung;Deok Jin Lee
    • Smart Media Journal
    • /
    • v.12 no.5
    • /
    • pp.81-87
    • /
    • 2023
  • In this paper, accidents in high-voltage overhead distribution lines, which provide stable power supply in the power system, cause inconvenience in life and disruption of production of companies. 22.9 [kV] high-voltage overhead power distribution lines aim to improve reliability and stability, such as damage caused by rain, snow, wind, etc., or electric shock prevention. Therefore, in order to prevent wire disconnection accidents due to deterioration of electrical conductivity or tensile strength due to corrosion of overhead distribution lines, it is necessary to prevent unexpected accidents in the future through regular inspection and repair. In order to diagnose deterioration due to corrosion of distribution lines, a diagnostic system (measuring instrument) is installed on the wires to monitor the condition of the wires. The manager on the ground receives the measured data through ZigBee wireless communication, controls the diagnosis system through the diagnosis system program, and grasps the condition of the overhead distribution line through the measured data and photographed photos, and predicts the life of the wire along with the visual inspection method. developed a program.

A Study on the Transmission Characteristics and Channel Capacity of Telephone Line Communication System (전화선 통신 시스템의 전송특성 및 채널용량에 관한 연구)

  • Roh, Jae-Sung;Chang, Tae-Hwa
    • Journal of Digital Contents Society
    • /
    • v.10 no.2
    • /
    • pp.233-238
    • /
    • 2009
  • The advances in the digital communication and network technology, Internet technology and the proliferation of smart appliances in home, have dramatically increased the need for a high speed/high quality home network. As consumer electronic devices and computing devices are increasing in the home network, it is obvious that the data traffic of home network increases as well. Various home network devices want to access Internet servers to get multimedia contents. Therefore, we introduce TLC(Telephone Line Carrier) system for networked digital consumer electronic appliances within a house using Ethernet or wire/wireless technology. In the future home network environment, the primary purposes of the smart home network based TLC are to create low-cost, easily deployable, high performance, and wide coverage throughout the home. In this paper, the channel capacity of telephone line communication system is evaluated and compared as a function of transmission power, number of OFDM carrier, channel loss, and noise loss for smart home network.

  • PDF

An Estimation of a Billet Temperature during Reheating Furnace Operation

  • Jang, Yu-Jin;Kim, Sang-Woo
    • International Journal of Control, Automation, and Systems
    • /
    • v.5 no.1
    • /
    • pp.43-50
    • /
    • 2007
  • Reheating furnace is an essential facility of a rod mill plant where a billet is heated to the required rolling temperature so that it can be milled to produce wire. Although it is very important to obtain information on billet temperatures, it is not feasible during furnace operation. Consequently, a billet temperature profile should be estimated. Moreover, this estimation should be done within an appropriate time interval for an on-line application. In this paper, a billet heat transfer model based on 2D FEM(Finite Element Method) with spatially distributed emission factors is proposed for an on-line billet temperature estimation and also a measurement is carried out for two extremely different furnace operation patterns. Finally, the difference between the model outputs and the measurements is minimized by using a new optimization algorithm named uDEAS(Univariate Dynamic Encoding Algorithm for Searches) with multi-step tuning strategy. The obtained emission factors are applied to a simulation for the data which are not used in the model tuning for validation.

Integrated management technology of environmental control facilities underground living space (지하 생활공간 환경제어 설비 통합관리 기술)

  • Gang, Hyeon-Geun;Kim, Tae-Han;Jeon, Jin-Han;Lee, Seung-Hong
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.95-98
    • /
    • 2008
  • A power line communications, power, the outgoing line is a means of communication. DC 12 volt power lines in the system over the 2-wire control signals with the power to send the cargo configuration, and, in the basement living space, temperature, humidity, dust, CO2 sensors, and through the cooperation of the real-time detection and valves of the appropriate amount of wind, fan was designed to control. By the system's ability to communicate and control the room temperature or the status of amount of wind sent to the central system to transmit and receive signals to the center of the future, the ability to control the company said. In addition, the system HMI (Human Machine Interface) terminal by the direct control and if necessary personal portable devices to communicate with the living conditions of the underground environment in the best state that the purpose is to build.

  • PDF

Neutral Current Calculation of Pole-Top Overhead Distribution Line (가공 배전선로 장주의 중성선 전류 계산)

  • Seo, Hun-Chul;Kwon, O-Sang;Kim, Chul-Hwan;Jung, Chang-Soo;Yoo, Yeon-Pyo
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.7
    • /
    • pp.290-296
    • /
    • 2006
  • If the three phases are not balanced, the current in neutral wire is not zero. Then, the induced voltage can be generated in communication line. The KEPCO's rule about unbalanced current for one step type in distribution pole is a twenty percent of phase current. But the unbalanced current for two step type in distribution pole can't decide the rule because there are many different views. This paper presents the calculation and analysis technique of neutral current in distribution poles using equivalent circuit analysis and EMTP simulation.

A Study on Management Method of Point and Line Data Using Mobile GIS (모바일 GIS를 이용한 Point 및 Line형 데이터 갱신 방법에 관한 연구)

  • Jeon, Jae-Yong;Cho, Gi-Sung
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.15 no.3
    • /
    • pp.3-10
    • /
    • 2007
  • As information communication technology matures, GIS is being evolved from wire communication GIS to mobile GIS. This is due that mobile GIS satisfy mobility, field work, speed and time. Also, this is proper that mobile GIS accomplish investigation, confirmation, input and modification operations of spatial and attribute data at field. I think mobile GIS's use is the best way. Because, Mobile GIS's use can accomplish effectively the management of various kinds facilities in city. On this study, we consider diversified methods a person in charge can management point and line data with more easy and more effective method. The management methods of pint type data are free method, offset method two point method. The management methods of line type data are free method, point connection method, point and line connection method and the minimum distance connection method between point and line.

  • PDF

Emissive Electromagnetic Field Measurement and Analysis for High Speed PLC on Medium Voltage Power-Line Channel (고속 전력선 통신을 위한 중전압 선로의 방사전자파 측정 및 분석)

  • 김선효;김상태;이영철;신철재
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.1
    • /
    • pp.54-61
    • /
    • 2003
  • This paper shows the results of emissive electromagnetic field characteristics on medium voltage power line(22.9 kV). The measurements were taken when communications signals were coupled into the 22.9 kV main wire of medium voltage power-line in a frequency range of 9 kHz to 30 MHz. The results of the measurement are as follows-emissive electromagnetic Held characteristics from multi carrier signals were superior to a single carrier signal. And we confirmed the PLC transmission distance was 1.8 km when multi-carrier transmission power was 20 dBm. Electric field strength was under the 40 dBuV/m at 30 MHz when 10 m method was measured.

A System-in-Package (SiP) Integration of a 62GHz Transmitter for MM-wave Communication Terminals Applications

  • Lee, Young-Chul;Park, Chul-Soon
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.4 no.3
    • /
    • pp.182-188
    • /
    • 2004
  • We demonstrate a $2.1\;{\times}\;1.0\;{\times}\;0.1cm^3$ sized compact transmitter using LTCC System-in-Package (SiP) technology for 60GHz-band wireless communication applications. For low-attenuation characteristics and resonance suppression of the SiP, we have proposed and demonstrated a coplanar double wire-bond transition and novel CPW-to-stripline transition integrating air-cavities as well as novel air-cavities embedded CPW line. The fabricated transmitter achieves an output of 13dBm at a RF frequency of 62GHz, an IF frequency of 2.4GHz, and a LO frequency of 59.6GHz. The up-conversion gain is 11dB, while the LO signal is suppressed with the image rejection mixer below -21.4dBc, and the image and spurious signals are also suppressed below -31dBc.