• Title/Summary/Keyword: Wire to Board

Search Result 88, Processing Time 0.021 seconds

System Development of SCSky CanSat With Smart Phone and Wide Swath Scan Camera Mechanism (스마트 폰 및 광역관측카메라 메커니즘 탑재 SCSky 캔위성 시스템 개발)

  • Kim, Hye-In;Kim, Jeong-Ki;Choi, Jae-Seop;Kim, Su-Hyeon;Oh, Hyun-Ung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.45 no.2
    • /
    • pp.154-162
    • /
    • 2017
  • CanSat Competition has been annually held in South Korea since 2012 to give students an opportunity for better understanding of system design and operation processes of satellite. SCSky CanSat(Smart Call from the Sky Can Satellite) proposed in this study is a name of CanSat that was participated in 2016 CanSat competition. Its main mission objective is to obtain flight imaging data of inside and outside the CanSat through the video call using on-board smart phone in the CanSat. To implement this mission, we developed a remote touch system using SMA(Shape Memory Alloy) wire. In addition, a wide scan camera mechanism using SMA spring was developed to obtain ground imaging data during the mission. This study introduced the mission of the SCSky CanSat, as well as the description of on-board payloads, system design results, and flight test results.

Long-term performance of drainage system for leakage treatment of tunnel operating in cold region (한랭지역에서 운영 중인 터널의 누수처리를 위한 유도배수시스템의 장기 성능 평가)

  • Kim, Dong-Gyou
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.6
    • /
    • pp.1177-1192
    • /
    • 2018
  • The objective of this study is to develop the existing drainage system for catching the partial leakage of tunnel structures operating in cold region. The drainage system consists of drainage board, Hotty-gel as a waterproofing material, cover for preventing protrusion of Hotty-gel, air nailer, fixed nail, pipe for collecting ground leak, pipe for conveying ground leak, wire-mesh, and sprayed cement mortar. The drainage systems were installed in conventional concrete lining tunnels to evaluate the site applicability and constructability. The performances of waterproof and the drainage in the drainage system were evaluated by injecting 1,000 ml of red water in the back of the drainage system at 7 days, 14 days, 21 days, 28 days, 2 months, 3 months, 4 months, 5 months, 6 months, 7 months and 8 months. During 8 months of field test, the average daily temperature of the tunnel site was measured from $-16.0^{\circ}C$ to $25.6^{\circ}C$. The daily minimum temperature was $-21.3^{\circ}C$ and the daily maximum temperature was $30.8^{\circ}C$. There was no problem in waterproof and drainage performance of the drainage board in the drainage system. However, the pipe for conveying ground leak had the leakage problem from 14 days. It is considered that the leakage of the pipe for conveying ground leak was caused by the deformation of the pipe of the flexible plastic material having a thickness of 0.2 cm by using the high pressure air nailer and the fixing pin and the insufficient thickness and width of the hotty-gel for preventing the leakage.

A Study on the Computational Design of Static Mixer and Mixing Characteristics of Liquid Silicon Rubber using Fluidic Analysis for LED Encapsulation (LED Encapsulation을 위한 스태틱 믹서의 전산 설계 및 유동해석을 이용한 액상 실리콘의 혼합 특성에 대한 연구)

  • Cho, Yong-Kyu;Ha, Seok-Jae;Huxiao, Huxiao;Cho, Myeong-Woo;Choi, Jong Myeong;Hong, Seung-Min
    • Design & Manufacturing
    • /
    • v.7 no.1
    • /
    • pp.55-59
    • /
    • 2013
  • A Light Emitting Diode(LED) is a semiconductor device which converts electricity into light. LEDs are widely used in a field of illumination, LCD(Liquid Crystal Display) backlight, mobile signals because they have several merits, such as low power consumption, long lifetime, high brightness, fast response, environment friendly. In general, LEDs production does die bonding and wire bonding on board, and do silicon and phosphor dispensing to protect LED chip and improve brightness. Then lens molding process is performed using mixed liquid silicon rubber(LSR) by resin and hardener. A mixture of resin and hardener affect the optical characteristics of the LED lens. In this paper, computational design of static mixer was performed for mixing of liquid silicon. To evaluate characteristic of mixing efficiency, finite element model of static mixer was generated, and fluidic analysis was performed according to length of mixing element. Finally, optimal condition of length of mixing element was applied to static mixer from result of fluidic analysis.

  • PDF

A Real-Time Embedded Speech Recognition System

  • Nam, Sang-Yep;Lee, Chun-Woo;Lee, Sang-Won;Park, In-Jung
    • Proceedings of the IEEK Conference
    • /
    • 2002.07a
    • /
    • pp.690-693
    • /
    • 2002
  • According to the growth of communication biz, embedded market rapidly developing in domestic and overseas. Embedded system can be used in various way such as wire and wireless communication equipment or information products. There are lots of developing performance applying speech recognition to embedded system, for instance, PDA, PCS, CDMA-2000 or IMT-2000. This study implement minimum memory of speech recognition engine and DB for apply real time embedded system. The implement measure of speech recognition equipment to fit on embedded system is like following. At first, DC element is removed from Input voice and then a compensation of high frequency was achieved by pre-emphasis with coefficients value, 0.97 and constitute division data as same size as 256 sample by lapped shift method. Through by Levinson - Durbin Algorithm, these data can get linear predictive coefficient and again, using Cepstrum - Transformer attain feature vectors. During HMM training, We used Baum-Welch reestimation Algorithm for each words training and can get the recognition result from executed likelihood method on each words. The used speech data is using 40 speech command data and 10 digits extracted form each 15 of male and female speaker spoken menu control command of Embedded system. Since, in many times, ARM CPU is adopted in embedded system, it's peformed porting the speech recognition engine on ARM core evaluation board. And do the recognition test with select set 1 and set 3 parameter that has good recognition rate on commander and no digit after the several tests using by 5 proposal recognition parameter sets. The recognition engine of recognition rate shows 95%, speech commander recognizer shows 96% and digits recognizer shows 94%.

  • PDF

System Design for Real-Time Measuring of Power Quality and Harmonics Distortion using Digital Signal Processor (Digital Signal Processor를 이용한 실시간 전력 요소와 왜율 측정 시스템 설계)

  • kim, Geun-Jun;Kang, Bongsoon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.7
    • /
    • pp.1283-1289
    • /
    • 2016
  • Electrical energy is the essential resource for modern society. Recently, the demand for power was significantly increased. Increase of power demand has lead to a decrease in the power quality. Power quality in modern society has been an important factor that can cause a major problem throughout the home and general industry. Therefore, we need a system for preventing the power quality problems. To avoid power issues, it is important that the measurement of the power quality and initial response. In this paper, we propose real-time power quality measurement system and harmonics monitoring system. We design the system using DM240001 board include dsPIC33FJ256GP710A of microchip. This system can adapt three-phase three-wire system. And optimized the algorithm, we can measure momentary changes of the power system. In addition, designed system can measure harmonics distortion like to VTHD, ITHD and ITDD for 31th harmonics.

CAN Data Compression Using DLC and Compression Area Selection (DLC와 전송 데이터 압축영역 설정을 이용한 CAN 데이터 압축)

  • Wu, Yujing;Chung, Jin-Gyun
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.11
    • /
    • pp.99-107
    • /
    • 2013
  • Controller area network (CAN) was designed for multiplexing communication between electronic control units (ECUs) in vehicles and thus for decreasing the overall wire harness. The increasing number of ECUs causes the CAN bus overloaded and consequently the error probability of data transmission increases. Since the time duration for the data transmission is proportional to CAN frame length, it is desirable to reduce the frame length. In this paper, a CAN message compression method is proposed using Data Length Code (DLC) and compression area selection algorithm to reduce the CAN frame length and the error probability during the transmission of CAN messages. By the proposed method, it is not needed to predict the maximum value of the difference in successive CAN messages as opposed to other compression methods. Also, by the use of DLC, we can determine whether the received CAN message has been compressed or not without using two ID's as in conventional methods. By simulations using actual CAN data, it is shown that the CAN transmission data is reduced up to 52 % by the proposed method, compared with conventional methods. By using an embedded test board, it is shown that 64bit EMS CAN data compression can be performed within 0.16ms and consequently the proposed algorithm can be used in automobile applications without any problem.

Thermo-mechanical Behavior of WB-PBGA Packages with Pb-Sn Solder and Lead-free Solder Using Moire Interferometry (무아레 간섭계를 이용한 유연 솔더와 무연 솔더 실장 WB-PBGA 패키지의 열-기계적 변형 거동)

  • Lee, Bong-Hee;Kim, Man-Ki;Joo, Jin-Won
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.17 no.3
    • /
    • pp.17-26
    • /
    • 2010
  • Pb-Sn solder is rapidly being replaced by lead-free solder for board-level interconnection in microelectronic package assemblies due to the environmental protection requirement. There is a general lack of mechanical reliability information available on the lead-free solder. In this study, thermo-mechanical behaviors of wire-bond plastic ball grid array (WB-PBGA) package assemblies are characterized by high-sensitivity moire interferometry. Experiments are conducted for two types of WB-PBGA packages that have Pb-Sn solder and lead-free solder as joint interconnections. Using real-time moire setup, fringe patterns are recorded and analyzed for several temperatures. Bending deformations of the assemblies and average strains of the solder balls are investigated and compared for the two type of WB-PBGA package assemblies. Results show that shear strain in #3 solder ball located near the chip shadow boundary is dominant for the failure of the package with Pb-Sn solder, while normal strain in #7 most outer solder ball is dominant for that with lead-free solder. It is also shown that the package with lead-free solder has much larger bending deformation and 10% larger maximum effective strain than the package with Pb-Sn solder at same temperature level.

A Study on the Administrative Enhancement for Health Center Activities (보건소(保健所) 행정(行政)의 기선을 위(爲)한 연구(硏究))

  • Moon, Ok-Ryun
    • Journal of Preventive Medicine and Public Health
    • /
    • v.3 no.1
    • /
    • pp.97-110
    • /
    • 1970
  • This survey was conducted to evaluate not only the present status of health center directors-their personal histories, their will to private practice in the future, their responses to governmental policies, -but also the distribution of doctorless myons, budget and subsidy, and director's opinions to the enhancement of health center activities. This survey questioned 116 health center directors and 16 health personnel from August to October of 1970 and obtained the following results; 1) The average ages of directors of kun, city, and total health centers were $43.2{\pm}7.8,\;42.1{\pm}7.7,\;and\;42.9{\pm}10.3$ respectively. 2) The average family sizes of directors of kun, city, and total health centers were $5.6{\pm}2.7,\;5.6{\pm}2.1,\;and\;5.6{\pm}2.6$ respectively. 3) Directors holding M. D. degrees were 79.3%, those holding qualified M. D. degrees ('approved director') were 20.7%. 4) M. P. H., M. S., and Ph. D. holders were 6.0%, 6.1%, and 4.3% respectively. 5) The average duration of present directorship in kun and city were 30.2 months and 20.4 months respectively. 6) The majority of directors had been employed in related fields before assuming current position : directorship at other health center 26.7%, army 22.4%, health subcenter 21.6%, private practice 19.0%. 7) Average length of directorship is 41.8 months. Average length of public health career, including health subcenter and present position, is 56.5 months. 8) Both rural and urban experience in health centers for regular directors is 16.3% and for approved directors, 12,5%. A total of 15.5% of all survey directors had experience in both rural and urban health center. 9) A total of 70.7% of health center directorships were staffed by local doctors. 10) Nearly 40% wanted to quit the directorships within 3 years and 60.3% had already experienced private practice. 11) Of the regular directors 17.4% felt strongly about devoting their lives to public health fields, but only 4.1% of the approved approved directors felt so. 12) There wire 432 doctorless myons among 996 respondent myons and 4.5 doctorless myons per kun. 13) The percentage of doctorless myon by Province are as follows, Cholla buk-do 57.2%, Cholla nam-de 55.0%, Kyungsang nam-do 52.0%, Kyungsang buk-do 49.7%, Chungchong but-do 42.4%, Kyonggi-do 32.9%. Cheju-do 30.8%, Kangwon-do 25.8%. 14) Two thirds of health critters have experienced the abscence of the director for a certain period since 1966 and the average span of the abscence was 18.2 months. 15) The percentage of doctorless myons increased proportionally with the span of the director's abscence. 16) The average budgets of health centers, kun, city and ku, were $W15.03\;million{\pm}W4.5\;million,\;W22.03\;million{\pm}W17.80\;million,\;W13.10\;million{\pm}W7.9\;million$ respectively. 17) Chunju city had the highest health budget per capita(W344) while Pusan Seo ku had the lowest(W19). 18) Director's medical subsidies are W30,000-50,000 in kun, and roughly W20,000 in city. 19) The older of priority in health center activities is T.B. control(31.1%), Family Planning and M. C. H.(28.0%), prevention of acute communicable disease and endemic disease (18.2%) and clinical care of patients(14.3%). 20) Nearly 32% opposed in principle the governmental policy of prohibiting medical doctors from going abroad. 21) Suggestions for immediate enhancing the position of director of health centers and subcenters: (1) Raise the base subsidy (48.2%), (2) Provide more opportunities for promotion (20.7%), (3) Exemption from army services(12.1%), (4) Full scholarship to medical students for this purpose only (7.8%). 22) A newly established medical school was opposed by 56.9% of the directors, however 33.6% of them approved. 23) Pertaining to the division of labor in Medicine and Pharmacy, the largest portion (31.9%) urged the immediate partial division of antibiotics and some addictive drugs to be given only by prescription. 24) More than half wanted a W70,000 level for the director's medical subsidies, white 36.2% stated W50,000. 25) Urgently needed skills in the kun are clinical pathologist (38.6%) and doctor (health center director) (25.5%); while in the city nurse (37.1%), doctors(clinical)(31.4%) and health educators(14.4%) are needed. 26) Essential treatment for the better health center administration; raising the base subsidy (22.7%), obtaining the power of personal management (19.3%) and the establishment of a Board of Health (14.3%). etc.

  • PDF