• 제목/요약/키워드: Wire structure

검색결과 655건 처리시간 0.029초

SMA을 이용한 3차원 형상제시기의 와이어프레임 구동 유닛 (Wire frame drive unit ofa SMA-based 3D shape display)

  • 추용주;김영민;송재복;박신석
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.439-440
    • /
    • 2006
  • This research proposes a novel method of shape display to present 3-dimensional objects. Shape displays allow us to feel the actual volume of the object, unlike conventional 2D visual displays of 3D objects. The proposed method employs a wire frame structure to present 3D objects. The wire frame is composed of small units driven by shape memory alloy(SMA) actuators. The drive unit is analogous to the agonist-antagonist system of animal musculoskeletal systems, where the SMA actuators serve as agonist and antagonist muscles. The force in the SMA actuator is controlled by electrical current. The drive unit is equipped with the locking mechanism so that it can sustain the external force exerted by the user as well as the own weight of the wire frame structure. By controlling the current into the SMA actuator and locking mechanism, we call control the angle of the drive unit. A chain of drive units enables presentation of 2 dimensional objects. 3 dimensional presentations are possible by collecting the chains of drive units.

  • PDF

Electrical and mechanical property of ZnO wire using catalyst-free chemical vapor deposition

  • Lee, Jin-Kyung;Jung, Un-Seok;Kim, Hak-Seong;Yun, Ho-Yeo;Seo, Mi-Ri;Jonathan, Ho;Choi, Mi-Ri;Wan, Jae;Kim, Gyu-Tae;Lee, Sang-Wook
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제40회 동계학술대회 초록집
    • /
    • pp.477-477
    • /
    • 2011
  • In this paper, we synthesize ZnO wire on Si substrate by catalyst-free thermal chemical vapor deposition (CVD). Each ZnO wire is grew up at different condition such as temperature and O2 flow rate. The Young's modulus of individual ZnO wires were estimated using quasi-static and dynamic measurements, as well as resonance frequency measurements. Using this system, current-voltage characteristics of each ZnO wire structure fabricated on a trench were measured. A new concept of electromechanical device structure combined with the piezoelectric effect of ZnO will be suggested in the end of this paper.

  • PDF

단선억제 및 가공정도 향상을 위한 Draw Tower의 구조 안정화 설계 (Structural Design of a Draw Tower for the Improved Stability and the Suppressed Wire Breakage)

  • 남규동;노승훈;윤현진;김영조;길사근;이대웅
    • 반도체디스플레이기술학회지
    • /
    • 제18권2호
    • /
    • pp.23-28
    • /
    • 2019
  • Wire breakage in drawing, which is the most critical process in glass fiber manufacturing, is caused by numerous factors such as height, drawing speed, and air flow. The vibrations of the draw tower, however, is the most dominant factor to create the wire breakage. In this study, the structure of a draw tower has been analyzed through experiments and computer simulations to figure out the main reasons of the vibrations. And the design alterations were applied to the machine to identify the effects of those alterations. The result shows that design alterations of the draw tower structure can suppress the 87% of the vibrations, and further can prevent the wire breakage.

와이어 직조 카고메의 기하학 (Geometry of Wire-wounded Bulk Kagome Structure)

  • 김헌수;강기주
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.1410-1415
    • /
    • 2007
  • Recently introduced WBK(Wire-wounded Bulk Kagome) shows relatively superior mechanical properties compared to other types of PCM. WBK is fabricated by assembling helical wires in 6 directions. Wire being a helix, the wire's geometric properties like pitch and helical radius shows certain geometric characteristics which can play some critical role in setting up an automatic fabrication process. In this study, geometry of WBK is modeled by various transformations of a piece of helical wire and the characteristics of the geometry of an element of WBK truss are discussed. In addition, the roles of pitch and helical radius of wire in optimizing the assembling process are described and the derivation of criteria is attempted to decide proper helical radius which would maintain minimal interference between wires at the crossings.

  • PDF

터널구간 팬터그래프와 전차선간 동적성능 검측장치 구현 (Implement of Dynamic Performance Measurement System Between Pantograph and Contact wire in Tunnel)

  • 박영;박철민;이기원;권삼영
    • 전기학회논문지
    • /
    • 제61권11호
    • /
    • pp.1732-1736
    • /
    • 2012
  • To increase speed up of train, in the field of catenary system, it is necessary to develop of new monitoring methods for dynamic interaction between pantograph and contact wire. Also, there is a need to develop technologies that constantly measure are from various railway structure such as uplift of contact wire, vibration of catenary, dynamic strain of contact line in tunnel. In this paper condition monitoring systems for dynamic performance of catenary systems in tunnel were proposed. An advanced method and results of field tests using high speed camera for monitoring of vertical upward movement of the grooved contact wire due to the force produced from the pantograph were presented. The proposed uplift measurement system of contact wire is expected to enhance precision of current collection quality performance assessment methods at high-speed lines.

항공기용 배선의 자가소화성에 관한 연구 (A Study on the Self-extinguishing for Aircraft Wire)

  • 정덕영;이백준;이종희
    • 항공우주시스템공학회지
    • /
    • 제5권1호
    • /
    • pp.13-16
    • /
    • 2011
  • All components such as structure, engine, electrical equipment, wire etc. should have certified qualities and functions for safe flight. The wire like a blood vessel of man is connected with most components and supply a electrical signal or power to them and only certified wire through a lot of tests such as rating, flame resistance, self-extinguishing, protection of EMI etc. must be used in aircraft. In other words, the wire should observe many certification requirements because it is one of the most important components.

전극선 성분 변화에 따른 냉간금형용강의 와이어방전가공 특성 (Characteristics of Wire EDM for Cold Die Steel due to the Different Wire Electrode Component)

  • 왕덕현;정순성
    • 한국기계가공학회지
    • /
    • 제2권2호
    • /
    • pp.98-105
    • /
    • 2003
  • In the experimental study, wire EDM was conducted for cold die steel by changing the Wire electrode, peak discharge current and number of finish cut. From the micro structure analysis of SEM photographs, the size of irregular welded and added component on the EDMed surface is decreasing and size of EDMed plane surface is increasing as the decreasing peak current and increasing number of finish cut. From the analysis of coating effect, Zn component is highly contained in Br and Zn Wire EDMed surface and copper component is highly contained in Br and Al wire EDMed surface. Hardness values are Increasing as the increasing peak current and decreasing the number of finish cut The value of hardness is decreasing as Cu, Al, Zn and Br wire electrode because of the residual austenite effect of solid solution copper on solidification, and finally EDMed surface has the highest hardness values for every wire electrode. Yield strength values becomes larger and bending strength values become smaller due to the increasing the hardness. These results are increased as increasing brittleness with hardness.

  • PDF

전선의 도체조직 분석에 의한 전기화재 감식 (Electrical Fire Identification due to Conductor Structure Analysis of Electrical Wires)

  • 박오철;김왕곤;박남규;홍진웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 추계학술대회 논문집 Vol.16
    • /
    • pp.615-618
    • /
    • 2003
  • To investigate the electrical fire identification due to conductor structure analysis of an electrical wire, we are studied by temperature heating test, over current test, short test and electric molten marks. And metal structure analysis of wire by short, we are found out increase in crystal grain with heating temperature. Structure of specimen at over current 300[%] occurred hardly structure formation and boundary of grain.

  • PDF

Transflective liquid crystal display with single cell gap and simple structure

  • Kim, Mi-Young;Lim, Young-Jin;Jeong, Eun;Chin, Mi-Hyung;Kim, Jin-Ho;Srivastava, Anoop Kumar;Lee, Seung-Hee
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2008년도 International Meeting on Information Display
    • /
    • pp.340-343
    • /
    • 2008
  • This work reports the simple fabrication of the single cell gap transflective liquid crystal display (LCD) using wire grid polarizer. The nano sized wire grid polarizer was patterned on common electrode itself, on the reflective part of FFS (Fringe field switching) mode whereas the common electrode was unpatterned at transmissive part. However, this structure didn't show single gamma curve, so we further improved the device by patterning the common electrode at transmissive part. As a result, V-T curve of proposed structure shows single gamma curve. Such a device structure is free from in-cell retarder, compensation film and reflector and furthermore it is very thin and easy to fabricate.

  • PDF

열적 스트레스 변화에 따른 600V 비닐절연전선의 특성 분석 (The Properties Analysis of 600V Grade Polyvinyl Chloride Insulated Wire with Variation of Thermal Stress)

  • 최충석
    • 한국화재소방학회논문지
    • /
    • 제15권1호
    • /
    • pp.108-115
    • /
    • 2001
  • 본 연구에서는 600V 비닐절연전선에 열적 스트레스를 인가하였을 때 전선의 특성 변화를 분석하였다. 전선의 구조 분석에서 정상 전선은 표면에 방향성을 갖고 있으나, $400^{\circ}c$ 이상에서 열화된 전선의 경우 탄화물, 크랙, 결정 등이 형성되었다. 정상 전선의 표면 조성은 Cu ; 100%였으나, $800^{\circ}c$에서 열화된 전선의 단면 조성은 Cu : 78.89%, O : 21.11%를 나타냈다. 연동선의 시차주사열량 분석 결과 $700^{\circ}c$ 이상에서 열화된 전선에서 새로운 반응 피크가 관측되었다. 절연물의 시차열 분석에서 $150^{\circ}c$로 열화된 전선의 경우 정상 전선의 반응점보다 낮은 $264^{\circ}c$에서 흡열 반응이 나타났다. 등선의 열화에 따른 산소 점유율은 $500^{\circ}c$에서 약 20%이다.

  • PDF