• Title/Summary/Keyword: Wire Device

Search Result 417, Processing Time 0.025 seconds

A Study on the Design of DICOM Integration Engine in the Ubiquitous Computing Environments (유비쿼터스 컴퓨팅 환경에서의 DICOM 설계에 대한 연구)

  • Im, In-Chul;Ha, An-Rye;Kim, Chang-Soo;Hwang, In-Chul;Ok, Chi-Sang
    • Journal of radiological science and technology
    • /
    • v.28 no.4
    • /
    • pp.307-315
    • /
    • 2005
  • In the ubiquitous computing environments, ICT industries of current society are developed in enormous growth. Medicine or patients with mobile devices can access at any time, any place. The medical procedures at the patient bedside are out of the scope of current systems, which means that patient record and image data access during the medical visit or the execution, recording and confirmation of the medicine prescriptions, still do not enjoy computerized support. Today, the exchange of medical images and clinical information is well defined by DICOM and HL7 standards. The DICOM independent terminal equipment image access system was developed in which a DICOM Engine acts as the gateway between a PACS DB and user's terminal. Implementation system is compatible with most currently available Integration system models. This paper presents a software technology where the medical and nursing staff will be equipped with any device connected by wire and wireless to a central server that provides access to the electronic patient records and that will actively inform about tasks pending distribution. The prototype described in this article implements a medical images and structured reports server that makes the search and recovery of data stored in the DICOM standard possible.

  • PDF

Study on Physical Properties of Domestic Species II: Sorption, Thermal, Electrical and Acoustic Properties of Pinus koraiensis and Larix kaempferi (국산재의 응용물성연구II: 잣나무 낙엽송의 수분흡착성 및 열적·전기적·음향적 성질)

  • Byeon, Hee-Seop;Lee, Won-Hee;Park, Byung-Soo;Chong, Sung-Ho;Kang, Ho-Yang
    • Journal of the Korean Wood Science and Technology
    • /
    • v.36 no.4
    • /
    • pp.1-10
    • /
    • 2008
  • A series of the studies on the applied physical properties of domestic species have been conducted last three years. Pinus koraiensis and Larix kaempferi were two of the three species examined for the first year. Because the same apparatus and experimental procedures were used for all species, their results can be easily comparable. The experiments for sorption property were conducted with 20- and 80-mesh wood powder and resulted in their EMCs and sorption isotherms at various RH conditions. The thermal conductivity and diffusivity, and electric resistance and volumetric electric resistivity were measured with a thermal-wire device and a high electric resistance meter. The differences in the thermal and electric properties between quarter- and flat-sawn specimens were observed, which were partially attributed to their anatomical differences. An acoustic measurement system was used to evaluate dynamic MOE and internal friction. This paper provides the useful fundamental data for designing a wood structure, correcting a portable resistance-type moisture meter, and acoustic properties of wood.

Study on Physical Properties of Domestic Species I: Sorption, Thermal, Electrical and Acoustic Properties of Pinus Densiflora (국산재의 응용물성연구 I: 소나무(Pinus densiflora)의 수분흡착성 및 열적·전기적·음향적 성질)

  • Kang, Ho-Yang;Byeon, Hee-Seop;Lee, Won-Hee;Park, Byung-Soo;Park, Jung-Hwan
    • Journal of the Korean Wood Science and Technology
    • /
    • v.36 no.3
    • /
    • pp.70-84
    • /
    • 2008
  • A series of the studies on the applied physical properties of domestic species have been conducted last three years. Pinus densiflora was one of the three species examined for the first year. Because the same apparatus and experimental procedures were used for all species, their results can be easily comparable. The experiments for sorption property were conducted with 20- and 80-mesh wood powder and resulted in their EMC's and sorption isotherms at various heating conditions. The thermal conductivity and diffusivity, and electric resistance and volumetric electric resistivity were measured with a thermal-wire device and a high electric resistance meter. The differences of the thermal and electric properties between quarter- and flat-sawn specimens were observed, which was partially attributed to their anatomical differences. An acoustic measurement system was used to evaluate dynamic MOE and internal friction. This paper provides the useful fundamental data for designing a wood structure, correcting a portable resistance-type moisture meter, and nondestructive testing wood.

Changes in Body Temperature of Piglets in a Day (자돈의 일중 체온변화에 관한 연구)

  • Yi, One-Hyeon;Jeong, Wang-Yong;Lee, Sang-Cheol;Lee, Sang-Rak
    • Journal of Animal Environmental Science
    • /
    • v.18 no.2
    • /
    • pp.91-94
    • /
    • 2012
  • This study was conducted to develop an algorithm for determination of abnormal body temperature in piglets through skin and core temperature database at normal condition. 5 piglets (mean BW : 46 kg) were employed for the experiment. They were adapted in the individual metabolism cage set at $22.5{\pm}2.0^{\circ}C$ of room temperature for 2 weeks before the measurement of body temperature. Ear, neck, head and subcutaneous neck temperature (as core temperature) of piglets were measured for every 1 minute during 30 consecutive days through 1mm k-type thermocouple wire and NI-devices (National Instruments Corporation, Austin, Texas, USA). Body temperature data were accumulated and integrated into the 1 day unit. Change of daily mean skin and core body temperatures in piglets were lowest at around 06:00, highest at around 14:00 and gradually decreased until the day after 06:00. Each skin temperatures were varied with the measuring site and largely depended on the room temperature changes. Established database of skin and core body temperature in piglets through this study can be applied to develop an algorithm for monitoring and determining the abnormal condition of animal by using radio frequency identification.

Double-Gauss Optical System Design with Fixed Magnification and Image Surface Independent of Object Distance (물체거리가 변하여도 배율과 상면이 고정되는 이중 가우스 광학계의 설계)

  • Ryu, Jae Myung;Ryu, Chang Ho;Kim, Kang Min;Kim, Byoung Young;Ju, Yun Jae;Jo, Jae Heung
    • Korean Journal of Optics and Photonics
    • /
    • v.29 no.1
    • /
    • pp.19-27
    • /
    • 2018
  • A change in object distance would generally change the magnification of an optical system. In this paper, we have proposed and designed a double-Gauss optical system with a fixed magnification and image surface regardless of any change in object distance, according to moving the lens groups a little bit to the front and rear of the stop, independently parallel to the direction of the optical axis. By maintaining a constant size of image formation in spite of various object-distance changes in a projection system such as a head-up display (HUD) or head-mounted display (HMD), we can prevent the field of view from changing while focusing in an HUD or HMD. Also, to check precisely the state of the wiring that connects semiconductor chips and IC circuit boards, we can keep the magnification of the optical system constant, even when the object distance changes due to vertical movement along the optical axis of a testing device. Additionally, if we use this double-Gauss optical system as a vision system in the testing process of lots of electronic boards in a manufacturing system, since we can systematically eliminate additional image processing for visual enhancement of image quality, we can dramatically reduce the testing time for a fast test process. Also, the Gaussian bracket method was used to find the moving distance of each group, to achieve the desired specifications and fix magnification and image surface simultaneously. After the initial design, the optimization of the optical system was performed using the Synopsys optical design software.

The Clinical Effect and Construction of a Stereotactic Whole Body Immobilization Device (전신 정위 고정장치 제작과 임상효과에 대한 연구)

  • 정진범;정원균;서태석;최경식;진호상;지영훈
    • Progress in Medical Physics
    • /
    • v.15 no.1
    • /
    • pp.30-38
    • /
    • 2004
  • Purpose: To develop a whole body frame for the purpose of reducing patient motion and minimizing setup error for extra-cranial stereotactic radiotherapy, and to evaluate the repositioning setup error of a patient in the frame. Materials and Methods: The developed whole body frame is composed of a base plate, immobilizer, vacuum cushion, ruler and belts. The dimension of the base plate is 130 cm in length, 50 cm in width and 1 cm in thickness. The material used in the base plate of the frame was bakelite and the immobilizer was made of acetal. In addition, Radiopaque angio-catheter wires were engraved on the base plate for a coordinate system to determine the target localization. The measurement for radiation transmission and target localization is peformed in order to test the utilization of the frame. Also, a Matlab program analyzed the patients setup error by using the patient's setup images obtained from a CCTV camera and digital record recorder (DVR). Results: A frame that is useful for CT simulation and radiation treatment was fabricated. The frame structure was designed to minimize collisions from the changes in the rotation angle of the gantry and to maximize the transmission rate of the Incident radiation at the lateral or posterior oblique direction. The lightening belts may be used for the further reduction of the patient motion, and the belts can be adjusted so that they are not in the way of beam direction. The radiation transmission rates of this frame were measured as 95% and 96% at 10 and 21 MV, respectively. The position of a test target on the skin of a volunteer is accurately determined by CT simulation using the coordinate system in the frame. The estimated setup errors by Matlab program are shown 3.69$\pm$1.60, 2.14$\pm$0.78 mm at the lateral and central chest, and 7.11 $\pm$2.10, 6.54$\pm$2.22 mm at lateral and central abdomen, respectively. The setup error due to the lateral motion of breast is shown as 6.33$\pm$ 1.55 mm. Conclusion: The development and test of a whole body frame has proven very useful and practical in the radiosurgery for extra-cranial cancers. It may be used in determining target localization, and it can be used as a patient immobilization tool. More experimental data should be obtained in order to improve and confirm the results of the patient setup error.

  • PDF

Operative treatment for Proximal Humeral Fracture (상완골 근위부 골절의 수술적 요법)

  • Park Jin-Young;Park Hee-Gon
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.2 no.2
    • /
    • pp.168-175
    • /
    • 2003
  • Fracture about proximal humerus may be classified as the articular segment or the anatomical neck, the greater tuberosity, the lesser tuberosity, and the shaft or surgical neck. Now, usually used, Neer's classification is based on the number of segments displaced, over 1cm of displaced or more than 45 degrees of angulation , rather than the number of fracture line . Absolute indication of a operative treatment a open fracture, the fracture with vascular injury or nerve injury , and unreductable fracture-dislocation . Inversely, the case that are severe osteoporosis, and eldly patient who can't be operated by strong internal fixation is better than arthroplasty used by primary prosthetic replacement and early rehabilitation program than open reduction and internal fixation. The operator make a decision for the patient who should be taken the open reduction and internal fixation, because it's different that anatomical morphology, bone density, condition of patient. The operator decide operation procedure. For example, percutaneous pinning, open reduction, plate & screws, wire tension bands combined with some intramedullary device are operation procedure that operator can decide . The poor health condition for other health problem, fracture with unstable vital sign and severe osteoporosis , are the relative contraindication. The stable fracture without dislocation is not the operative indication . The radiologic film of the prokimal humerus before the operation can not predict for fracture evaluation. It's necessary to good radiologic film for evaluation of fracture form. The trauma serise is better than the other radiologic film for evaluation. The accessary radiologic exam is able to help for evaluation of bone fragment and anatomy. The CT can be helpful in evaluating these injury, especially if the extract fracture type cannot be determined from plain roenterogram of the proximal humerus, bone of humerus head. If the dislocation is severe anatomically , we could consider to do three dimentional remodelling. The MRI doing for observing of bony morphology before the operation is not better than CT If we were suspicious of vascular injury, we could consider the angiography.

  • PDF