• Title/Summary/Keyword: Windows and Doors System

Search Result 45, Processing Time 0.024 seconds

Constructability Analysis in Aged-Housing Remodeling Demolition Work for Maximizing Waste Recycling (폐기물 재활용성 향상을 위한 리모델링 철거공사의 시공성 평가 및 사례적용)

  • Chae, Seong-Hyun;Kim, Ki-Hyun;Cha, Hee-Sung;Kim, Kyung-Rai;Han, Ju-Yeoun
    • Korean Journal of Construction Engineering and Management
    • /
    • v.11 no.3
    • /
    • pp.13-22
    • /
    • 2010
  • From now on, the aged apartment or house is expected to increase rapidly. So, we have to build a process of remodeling and develop the new technique. Demolition work is needed for systematic plan and management. However, contractors of the remodeling project established a rough plan and did not consider recycling wastes, safety of workers and structural stability of building. Therefore, we need a step to develop a assessment system, verify and make specified. This paper evaluated how much improve on construction speed, work efficiency, intensity of work and influence with another process comparing the existing method with the new demolition method. The qualitative and quantitative assessment system are developed with these output. The case study was carried out experimental group and control group, based on developed assessment system, which have the same condition. The existing method was made up of 3 steps- 1)Demolish windows, doors and iron goods, 2)Demolish indoor and outdoor walls, 3)Drop the waste. The new demolition method was made up of 5 steps- 1)Demolish windows, doors and iron goods, 2)Demolish the ceiling and wall's finishing materials, 3)Demolish the floor's finishing materials, 4)Demolish indoor and outdoor walls, 5)Drop the waste. Work time, idle time, the character of a work unit are analyzed by mock-up test. This study's output is expected to establish a systematic process of new demolition method and based on the maximizing waste recycling work in our construction industry.

A Development of an Intelligent CAD Engine to Support Architectural Design Collaboration (건축설계의 협동작업을 지원하는 지능형 CAD 엔진의 개발)

  • 최진원
    • Korean Journal of Computational Design and Engineering
    • /
    • v.2 no.1
    • /
    • pp.53-59
    • /
    • 1997
  • Current CAD systems used in the AEC community have some critical problems. One of them is that they hardly support design collaboration. Thus designers and engineers are hard to transfer design knowledge from one discipline to another. What we need is a common building database which creates and manages building plans/models and relevant design knowledge consistently and effectively. This paper presents a powerful CAD editor, called UNIFORM, which is being developed. Currently UNIFORM includes three main modules: a plan generator, a 3-D model generator, and component databases. A plan generator, called UNIFORM PLANNER, creates a plan which contains semantically-rich information of building. Each component in the plan can be presented in various ways and connected to component databases that contain knowledge of building components such as windows, doors, walls, etc. Based on the plan UNIFORM MODELER, another module of the program, generates a three dimensional building model which could be a multiple-story building. One of the main ideas behind the system is that it generates and maintains a common building form that can be easily delivered to other members of the project team. Thus it is expected to increase system integration, team interactions, and productivity.

  • PDF

Technical Measures for Improving Energy Efficiency in Historic Buildings -Focused on Researches and Case Studies of the West- (역사적 건축물의 에너지 효율 향상을 위한 계획기법 -서양의 연구동향 및 사례를 중심으로-)

  • Kim, Tai-Young
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.20 no.1
    • /
    • pp.69-76
    • /
    • 2018
  • This study is to research technical measures for improving energy efficiency in the conservation and reuse of historic buildings focused on the recent research trends and case studies of the west. These measures are broadly classified into three types, the passive measures for saving energy and increasing comfort, the most cost-effective energy saving strategies, and the renewable energy sources. Firstly, the passive measures are divided into the elements and systems. The passive elements are awnings and overhanging eaves, porches, shutters, storm windows and doors, and shade trees. There are also the natural ventilation systems such as the historic transoms, roofs and attics to improve airflow and cross ventilation to either distribute, or exhaust heat. Secondly, the most cost-effective energy efficiency strategies are the interior insulation, airtightness and moisture protection, and the thermal quality improvement of windows. The energy efficiency solutions of modern buildings are the capillary-active interior insulation, the airtightness and moisture protection of interior walls and openings, and the integration of the original historic window into the triple glazing. Beyond the three actions, the additional strategies are the heat recovery ventilation, and the illumination system. Thirdly, there are photovoltaic(PV) and solar thermal energy, wind energy, hydropower, biomass, and geothermal energy in the renewable energy sources. These energy systems work effectively but it is vital to consider its visual effect on the external appearance of the building.

A Study on the Attractive Items of Hanok in Urban Area focused on Preceding Studies (선행연구에 나타난 도시한옥의 매력 요소에 관한 연구)

  • Min, Sae-Rom;Kim, Tai-Young
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.14 no.3
    • /
    • pp.61-68
    • /
    • 2012
  • The purpose of this paper is to derive attractive items of 'Hanok' in order to preserve 'Hanok' in urban area, focused on the 13 preceding studies which have got in respect of image, satisfaction, preference, awareness and advantage of 'Hanok' in urban area revolved around the latest studies. This study is analysis of questionnaire items and results of 13 preceding studies. And attractive items are classified with general and overall survey items, advantage of 'Hanok' in urban area, and image of Hanok-density urban area. These can also be classified with 5 items which are space, health, material, form, and image of 'Hanok' in urban area. As a result, Space items are composed with 'use of a space', 'cosiness', 'garden' and 'floor and ondol(korean floor heating system). Health items are composed with 'lighting and ventialtion', 'a sense of the season' and 'natural material'. Material items are composed with 'natural beauty', 'wooden', 'changhoji(traditional Korean paper made from mulberry bark for doors and windows) and hanji(traditional Korean paper handmade from mulberry trees), 'rafter' and 'new materials'. Form items are composed with 'attractive appearance', 'simply decoration' and 'traditional elements'. Image items are composed with 'crowding', 'traditionality and historicity', 'dichroism' and 'warmth'.

Construction History of the Old House "IMCHEONGGAK" in Andong and Estimation of its Original Structure -Focused on the 'Inner chamber' and the 'Sarang section'- (안동 "임청각(臨淸閣)"의 건축 이력과 원형 가구(架構) 추정 -사랑채와 안채를 중심으로-)

  • Lee, Jong-Seo
    • Journal of architectural history
    • /
    • v.25 no.2
    • /
    • pp.31-44
    • /
    • 2016
  • Imcheong-gak[臨淸閣] was a familial residence constructed in the early half of the Joseon dynasty period. It was partially destroyed by a fire during the 1590s war[壬辰倭亂] with the Japanese, and another fire that was caused between 1631 and 1634. The inner chamber[An-chae] and the Sarang section[Sarang-chae] today is the result of a partial reconstruction that took place back in 1626 and again around 1634. The residence also went through some changes because the new Ondol[溫突] heating system had to be applied to the structure. Based upon sections that remain in their original forms, we can presume that the Imcheong-gak residence originally had an inner chamber which was composed of the following elements: A main structure which was built upon a foundation featuring a Matbae[맞배] roof, two "Ik'rang[翼廊, flank]" sections on the East and West sides of the inner chamber, and a "Haeng'rang[行廊, passage]" structure on the opposite side of the main structure. Unlike the main structure, other portions of the inner chamber were all built directly upon the ground, and showed multiple stories, with Matbae roofs of their own. We can also assume that the Sarang section in the south would have been a pre-Ondol[溫突] bedroom, with a Board platform[板房] and a Gomi-ceiling[Gomi-banza] fashion.

An Experimental Research on the Room Acoustical Environment of the Elementary School Classrooms (초등학교 교실의 음환경 평가에 관한 실험적 연구)

  • Haan, Chan-Hoon;Moon, Kyu-Chun
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.11 no.1
    • /
    • pp.5-14
    • /
    • 2004
  • Since 1990s in Korea, elementary school classrooms have been designed toward open education system in pursuit of variety of educational purpose. Also, the architectural designs of schools have been acomplished for individual school not based on the standard design code. The present paper aims to investigate the acoustic environment of existing classrooms and to compare the sound insulation capacity between the ordinary classrooms and the newly built classrooms for open education. The current acoustical situation of elementary classrooms was analyzed using field measurements and questionnaire survey. In order to this, Three elementary schools were selected which were built in 1978, 1996 and 2000 respectively. Room acoustical parameters including Reverberation time(RT), Definition(D50), Speech Intelligibility(RASTI), Transmission loss(TL) and STC were measured in a classroom in each elementary school classroom. Each measurement was undertaken with the windows and doors being open or closed. As the result, it was found that the transmission loss between rooms in open classrooms is, $5{\sim}6dB$ in average, inferior than the ordinary classrooms. The RASTI of 0.70 was measured in newly built classrooms which is better than old classrooms(0.70) and open classrooms(0.73). This was shown as same in the speech definition measurements. This results from the condition of sealing and airtightness of classrooms and floor materials. The results denote that open classrooms have poor acoustic condition in sound insulation and speech intelligibility.

Study on the Development of the Mobile Pig Nursery for Early Weaned Piglet (조기이유 자돈 사육을 위한 이동식 자돈사 개발에 관한 연구)

  • 유용희;이덕수;정일병;이진우;전병수;한정대
    • Journal of Animal Environmental Science
    • /
    • v.4 no.1
    • /
    • pp.1-8
    • /
    • 1998
  • The objective of this study was conducted to develope a mobile pig nursery(MPN) for segregation of early weaned piglet. The units of MPN was consisted of 4 rectangle-type pens, 1 workroom, 2 doors, 3 windows, 1 air-inlet, 1 exhaust fan, and 1 cooling and heating system. Total of 40 piglet were weaned at 7 days of age. The period of the feeding test was 63 days. The results obtained are as follows: 1. The insulation thickness was 70, 70 and 50 mm of roof, floor and wall, respectively. R-value was 15.32 and 10.32 of roof and wall, respectively. 2. Exhaust fan( 30.48) was installed near back door 40cm from the bottom. When exhaust fan speeds were 15, 20, 30 and 35%, Air ventilation was required 9.75, 7.07, 1.72, 1.45 minutes of respectively. 3. Average temperature in the MPN was able to maintain 27∼28$^{\circ}C$ from 7∼28 days of age, 24∼25$^{\circ}C$ from 35∼56 days of age and 20∼21.5$^{\circ}C$ from 56∼70 days of age. 4. Average daily gain, feed intake and feed conversion were 420.6g, 761.5g, 1.81 respectively.

The Steel Coupling Beam-Wall Connections Strength

  • Park, Wan-Shin;Yun, Hyun-Do
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.1 s.91
    • /
    • pp.135-145
    • /
    • 2006
  • In high multistory reinforced concrete buildings, coupled shear walls can provide an efficient structural system to resist horizontal force due to wind and seismic effects. Coupled shear walls are usually built over the whole height of the building and re laid out either as a series of walls coupled by beams and/or slabs or a central core structure with openings to accommodate doors, elevators walls, windows and corridors. A number of recent studies have focused on examining the seismic response of concrete, steel, and composite coupling beams. However, since no specific equations are available for computing the bearing strength of steel coupling beam-wall connections, it is necessary to develop such strength equations. There were carried out analytical and experimental studies to develop the strength equations of steel coupling beam-connections. Experiments were conducted to determine the factors influencing the bearing strength of the steel coupling beam-wall connection. The results of the proposed equations were in good agreement with both test results and other test data from the literature. Finally, this paper provides background for design guidelines that include a design model to calculate the bearing strength of steel coupling beam-wall connections.

Kim-Won Dental Clinic Interior Design (김원치과의원 실내디자인)

  • Choi, Sun-Hee
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2006.05a
    • /
    • pp.99-100
    • /
    • 2006
  • The concept of dental clinic have been changed along the advanced dental science to meet the need of setting up high-technology-digital appliances. As the general idea about the dental clinic has been changed from systematic connection, the expansion of zoning needs to become more accurate and mote detailed. In the spacious waiting room. the interment cafe has been established to supply the information services, and the various multi-imaged channels, which were built in, will relieve the boredom of the waiting time. The formation of water space leads to the effect of humidification and makes parents share visual and auditory sympathy All of the unit-chairs attached cameras in the consultation room enables people to diagnose more quickly and precisely through the computerized system. Partitions have been set of to put it in and to help diagnosis process to be done smoothly in the formational space. The whole atmosphere is intended to be harmony with the natural surroundings in Je-Ju. It will inspire people visiting this clinic to image the deep blue sea in Je-Ju. By using projective non-material a lot, especially material wooden windows and doors, it is believed to create the bright and stable atmosphere. It will lead patients feel comfortable.

  • PDF

A Study on the Degree of Satisfaction and Preference to Space Plan of Supporting Facilities in Department Stores (백화점 지원시설 계획요소에 관한 만족도 및 선호도 연구)

  • Park, Eui-Jeong;Seo, Ji-Eun
    • Korean Institute of Interior Design Journal
    • /
    • v.18 no.6
    • /
    • pp.194-201
    • /
    • 2009
  • The purpose of this study is to develop basic data for the efficient space plan of the Department Store focusing on users by survey of preference to methods of plan considering the functional phase, the economical phase and the adaptable phase. The results are as follows : First, we could know that users had the low degree of satisfaction to the adaptable phase of space plan for Supporting Facilities in department stores at the present time. Second, we must have the appropriate space size by using structure, doors and windows for user's satisfaction. This is the method of plan considering the functional phase for Supporting Facilities. And we could think that the methods of using the center flow plan and the arrangement of two or three facing are good for user's satisfaction. Third, it will be efficient plan if we find methods to be cleaned the structure easily and to be changed and repaired the system furniture easily for management. that methods are to be considered the economical phase for Supporting Facilities. Forth, methods of plan considering the adaptable phase are to change the size of space by using the movable type furniture and the form of space by changing structure.