• Title/Summary/Keyword: Windowless

Search Result 58, Processing Time 0.031 seconds

Relationship and Characteristics of PM10 and Endotoxin Concentrations in Windowless Poultry Houses in South Korea (일부 밀폐형 무창계사에서 발생하는 PM10 및 엔도톡신의 특성 및 연관성 분석)

  • Kim, Hyocher;Sin, Sojung;Kim, Kyungsu;Jung, Wongeon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.31 no.4
    • /
    • pp.331-341
    • /
    • 2021
  • Objectives: The aim of this study was to evaluate the concentrations and relationships of coarse particles with a diameter of 10 ㎛ (PM10) with endotoxins according to the time of measurement in windowless poultry houses. Methods: In this study, measurement was performed on ten windowless poultry houses with a vertically integrated system from July to November. PM10 was measured using personal environmental monitors and polytetrafluoroethylene (PTFE) filters with a 4 L/min-calibrated pump in selected sampling locations (two near the door and two near an exhaust fan). The endotoxin on PTFE filter was analyzed by the LAL turbidimetric method. Results: The range of geometric mean concentrations of PM10 and endotoxins for each of the 38 samples were 0.12-3.30 mg/m3 and 11.9-3553.66 EU/m3, respectively. PM10 and endotoxin concentrations varied by farm, increasing with the decrease in ventilation. The range of the coefficient of determination between PM10 and endotoxin was 0.0009-0.9249. As the atmospheric temperature decreased, it was confirmed that the concentrations of PM10 and endotoxin increased because the volume of ventilation was decreased. Conclusions: Endotoxins were more affected by time of measurement and ventilation than PM10, which means that endotoxins could be an important indicator for intervention programs for improvement of indoor environments.

Development of Exhaust Fan with an Embedded Controller for Windowless Swine Housing (무창돈사를 위한 컨트롤러 일체형 환기팬 개발)

  • Kim, Woong
    • Journal of agriculture & life science
    • /
    • v.50 no.2
    • /
    • pp.187-194
    • /
    • 2016
  • The purpose of this study was to analyze temperature distribution characteristics using a model swine housing for temperature sensor adjustable positioning and developed a sensor and controller embedded exhaust fans utilizing ICT fusion technology for windowless swine housing. Temperature measured by the sensor attached on the exhaust fan was also determined that there is no problem, the temperature is located in the upper fan given the measured errors shown in the 1℃ temperature difference between the lower temperature than the other positions in the model swine housing. The performance of the exhaust fan at maximum output was found to be 1920rpm, air flow rate 125㎥/min. When the open area ratio of 70% one proper air volume of the exhaust fan was found to be 75㎥/min, 60pa. Maximum efficiency in all of the output of the exhaust fan is exhibited at about 70% open area ratio of the damper. The number of revolution of the exhaust fan was 1920rpm when the output was a maximum of 100%. AC output phase of the pulse duty ratio change of the controller was shown to change without delay. It was determined that the instant fan speed control is possible.

Conducted to Verify the Effect of Chlorine Dioxide (ClO2) on Odor Reduction at a Commercial Swine Facility (이산화염소 가스분무에 의한 양돈장 악취저감 효과)

  • Song, J.I.;Jeon, J.H.;Park, K.H.;Yoo, Y.H.;Kim, D.H.
    • Journal of Animal Environmental Science
    • /
    • v.17 no.sup
    • /
    • pp.43-50
    • /
    • 2011
  • This study was conducted to verify the effect of chlorine dioxide ($ClO_2$) on odor reduction at a commercial swine facility consisting of a windowless piglet barn and a grower/fattening barn. The windowless piglet barn used a duct ventilation system. Air velocity at very below the upper duct was 4.53 m/s. Air velocity at the lower space around the living space of pigs in the grower/fattening barn was 0.26 m/s. $NH_3$ concentration was around 9ppm and less than 3 ppm before and after the $ClO_2$ spraying, respectively, which was over 70% reduction. There was no $H_2S$ detection. $NH_3$ concentrations measured in the windowless grower/fattening barn and at the exhausted air were 26 ppm and 11ppm, respectively. $NH_3$ concentration at a biocurtain outside was less than 1 ppm. Hence, $ClO_2$ spraying at windowless barns was effectively decreased malodor such as $NH_3$.

A Survey on Egg Laying Performance and Distribution Status of Animal Welfare Certified Farms for Laying Hens (산란계 동물복지 인증 농가의 사육 및 유통 현황 조사)

  • Hong, Eui-Chul;Kang, Hwan-Ku;Park, Ki-Tae;Jeon, Jin-Joo;Kim, Hyun-Soo;Kim, Chan-Ho;Kim, Sang-Ho
    • Korean Journal of Poultry Science
    • /
    • v.46 no.2
    • /
    • pp.55-63
    • /
    • 2019
  • This study was conducted to evaluate animal welfare approved farms in three housing systems (open, windowless, and free-range). The survey was conducted in 25 animal welfare approved farms, and 10 farms were surveyed for distribution status. The main breed in all animal welfare approved farms of laying hens was Hy-Line Brown variety. In the case of open house, laying hens were bred in traditional and panel houses simultaneously; however, the ratio of panel house was 58.3%, which was higher than that of the traditional house. All the windowless houses were made of panels and more than 15,000 laying hens were housed in a single windowless house. In the case of free-range house, it was maintained on a small scale of less than 12,000 birds. Fifty-six percent of the surveyed farms were breeding at $7{\sim}8birds/m^2$. In terms of male and female ratios, most farms maintained 1 male:15 females, but there was a farmhouse that switched 17 or 20 females to 1 male. The daily dietary allowance was 110~170 g, and 32% of the surveyed farms provided feed of more than 150 g/day, which showed that forage feed was important. The age of at the first egg was 123 days, 122 days, and 120 days, and the peak percent was 91.8%, 94.9%, and 86.5% in open, windowless and free-range houses, respectively. The average egg production rate was 74.0%, 84.6%, and 72.7% in open, windowless, and free-range houses respectively, thus, there was no correlation between feed intake and hen-housed eggs. Distribution of welfare certified eggs was mainly a direct deal with the consumer or through contract production. The ratio of direct transactions between large-scale marts and eco-friendly specialty stores of welfare approved eggs was higher than that of conventional eggs. The rate of contract sales of eggs in both the barn and free-range systems was high, and the percentage of courier sales farms was also high. Excluding courier services, price of eggs in the barn system rose to more than 30 won/egg in the second half of 2017 (after AI). Price of eggs in the free-range system rose to more than 50 won/egg in the second half of 2017 (after AI). In the case of courier sales, the same price of 500 won was maintained before and after AI. In conclusion, the results of this study can be used as basic data for improving the animal welfare certification system for laying hens in Korea.

The Effect of Vantilation System Renovation from Winch Style to Non-window Style for Swine Barn (개방돈사의 무창돈사형 환기시설 개선 효과)

  • Song, J.I.;Jean, J.H.;Park, H.K.;Kang, H.S.;Choi, D.Y.;Kim, D.H.;Park, K.H.
    • Journal of Animal Environmental Science
    • /
    • v.16 no.2
    • /
    • pp.109-114
    • /
    • 2010
  • In South Korea, mora than 90% of swine barns had open-style side wall by winch operation, and less than 5% of swine barns were semi-windowless or windowless style. The aisle ventilation system of the barn was changed to roof-wall ventilation system, and the width and the length of barns were 10~12 m and 30~50 m, respectively. The width of aisle satisfying energy save was 2~3 m. The re-modeled barns inhaled air through duct which was opened to aisle and exhaled through forced ventilation fans on the windowless wall which was accomplished by installing planks on the open wall. After remodelling, the culling ratio and energy cost were decreased from 11% (47 heads) to 3% (12 heads) and from 1,550,000 won to 730,000 won, respectively. Hence, re-modeled swine barns raising 400 heads could save 2,835,680 won during winter (from December to March).

현대 전투기 조종실 계기 및 조작기의 기술 현황 및 발전추세

  • Kim, Mun-Yeol
    • Defense and Technology
    • /
    • no.9 s.283
    • /
    • pp.66-73
    • /
    • 2002
  • 대부분의 현대 항공기 조종실은 유사한 형태인 HUD, 2개 이상의 MFD, UFC, HOTAS 등으로 구성된다. 앞에서 언급한 바와 같이 최근에는 전투기에도 HMD와 DVI(Direct Voice Input)를 적용하고 있다. 미래의 조종실은 빠르게 발전하고 있는 평면 시현 기술로 인해 HDD는 2010년대에는 15 X 20인치 크기까지 지원이 가능할 것으로 예상되며 HUD가 없어지고 높은 해상도가 넓은 시계영역을 가진 HMD가 없어지고 높은 해상도와 넓은 시계영역을 가진 HMD로 다중 운용(Joing Service Operability) 및 다중 임무 수행이 가능한 조종실이 될 것이며 2025년대에는 레이저 운용에 적합한 조종실로 변화되어 캐노피가 없는 조종실(Windowless Codkpit) 또는 불투명 HMD를 사용한 설계개념으로 발전할 것이다.

  • PDF

Necessary Conditions for Optimal Ventilation of Small Windowless Piglet House with Negative Tunnel Ventilating System (소규모 음압터널환기방식 무창자돈사의 최적 환기 요건에 관한 연구)

  • Lee, Seung-Joo;Chang, Dong-Il;Gutierrez, Winson M.;Park, Jeong-Sik;Jeon, Sang-Hoon;Cho, Hyoung-Je;Oh, Kwon-Young;Chang, Hong-Hee
    • Journal of Biosystems Engineering
    • /
    • v.34 no.1
    • /
    • pp.63-68
    • /
    • 2009
  • This study was carried out to determine necessary conditions for optimal ventilation of small windowless piglet house (5.2 (W) ${\times}$ 12.3 (L) ${\times}$ 2.3 (H) m) with negative tunnel ventilating system using CFD (Computational Fluid Dynamics) simulation. The weaning piglet house for this experiment was consisted of 4 rooms (520 (W) ${\times}$ 300 (L) cm), 3 fences (70 (H) cm), 1 air inlet (350 (W) ${\times}$ 2 (H) cm) and 1 exhaust fan (50 (D) cm), and simulated using CFD code, FLUENT. The simulation results for the original weaning piglet house showed ununiform ventilation for each room. Therefore, to uniformly ventilate all rooms, the heights of the air inlet and first fence were modified to 3 cm and 100 cm, respectively. The simulation result f3r the modified weaning piglet house showed uniform ventilation for all rooms and the optimum air inlet velocity of 1.4 m/s.

Environmental Analysis of a Windowless Delivery Swine Building : Temperature and Relative Humidity (무창분만돈사의 온.습도 환경 분석)

  • 이성현;조한근;장유섭
    • Journal of Animal Environmental Science
    • /
    • v.3 no.2
    • /
    • pp.77-85
    • /
    • 1997
  • Recently, local swine producers are rapidly adopting the indoor production system which developed in foreign countries. However, this imported system is reported as not functioning properly because of different climate conditions. The objective of this project was to investigate the environment characteristics of a windowless delivery swine building. The parameters studied were the heating and cooling loads, the daily changes of indoor temperature and relative humidity, the horizontal and the vertical distributions of indoor temperature, and the effect of mist cooling on indoor temperature. From this study, the following are founded : 1. The maximum cooling and heating loads were - 317.0kcal/㎡$.$h and 336.5kal/㎡$.$h in summer and in winter. The large loads seems to be on account of inappropriate operations of ventilating fans. 2. The daily variations of relative humidity in indoor were smaller than those in outside. Those values both in summer and in winter as relative humidities in door was lower than optimum for growing pigs, the additional humidifier might be helpful to increase the relative humidity in indoor. 3. The horizontal distribution of the indoor temperature was found to be uniform in the variation range of 1$^{\circ}C$. 4. The vertical distribution of the indoor temperature was not found to be uniform; the temperature of upper part was higher than that of slot part. 5. Average values of indoor temperature became lower by 3$^{\circ}C$ by mist cooling. But the variation of temperature was found to be larger; The middle part of the room was cooled down, but the corner part of the room was not affected by misting due to uneven nozzle configuration.

Study on the Swine Farming Facilities by Survey for the Development of the Optimum Production System Models (최적화 생산시스템 모델 개발을 위한 양돈시설의 조사 연구)

  • 장동일;이봉덕;조한근;장홍희
    • Journal of Animal Environmental Science
    • /
    • v.2 no.1
    • /
    • pp.1-11
    • /
    • 1996
  • This study was conducted to analyze the present status and the levels of mechanization and automation for raising, feeding, water supply, propagation, health management, ventilation and heat control, data analysis, and etc, and to establish the guide of the future study on development of the optimum production system models of swine facility from the results of this analysis. The scheme of the future study on the development of the optimum production system model of swine facility was established as follows : 1. A Korean and environmental control type slatted windowless swine housing model would be developed according to the following basis : \circled1 Boars, gilts and sows, delivery sows should be raised individually and piglets, growing pigs, and finishing pigs should be raised in group. \circled2 The arrangement of furrowing house were two rows of furrowing crates facing the center aisle. 2. The environmental control system and waste management system that are suitable to Korean and environmental control type slatted windowless swine housing model would be developed. 3. An electronic identification device would be developed. 4. The automatic individual wet feeding system by electronic identification device and computers would be developed. 5. The individual management system would be developed, which could manage individually the breeding pigs by the electronic identification device. 6. An expert system would be developed, which could manage the health and data base of pigs.

  • PDF