• Title/Summary/Keyword: Window width

Search Result 141, Processing Time 0.034 seconds

Electrochemical double layer capacitors with PEO and Sri Lankan natural graphite

  • Jayamaha, Bandara;Dissanayake, Malavi A.K.L.;Vignarooban, Kandasamy;Vidanapathirana, Kamal P.;Perera, Kumudu S.
    • Advances in Energy Research
    • /
    • v.5 no.3
    • /
    • pp.219-226
    • /
    • 2017
  • Electrochemical double layer capacitors (EDLCs) have received a tremendous interest due to their suitability for diverse applications. They have been fabricated using different carbon based electrodes including activated carbons, single walled/multi walled carbon nano tubes. But, graphite which is one of the natural resources in Sri Lanka has not been given a considerable attention towards using for EDLCs though it is a famous carbon material. On the other hand, EDLCs are well reported with various liquid electrolytes which are associated with numerous drawbacks. Gel polymer electrolytes (GPE) are well known alternative for liquid electrolytes. In this paper, it is reported about an EDLC fabricated with a nano composite polyethylene oxide based GPE and two Sri Lankan graphite based electrodes. The composition of the GPE was [{(10PEO: $NaClO_4$) molar ratio}: 75wt.% PC] : 5 wt.% $TiO_2$. GPE was prepared using the solvent casting method. Two graphite electrodes were prepared by mixing 85% graphite and 15% polyvinylidenefluoride (PVdF) in acetone and casting n fluorine doped tin oxide glass plates. GPE film was sandwiched in between the two graphite electrodes. A non faradaic charge discharge mechanism was observed from the Cyclic Voltammetry study. GPE was stable in the potential windows from (-0.8 V-0.8 V) to (-1.5 V-1.5 V). By increasing the width of the potential window, single electrode specific capacity increased. Impedance plots confirmed the capacitive behavior at low frequency region. Galvanostatic charge discharge test yielded an average discharge capacity of $0.60Fg^{-1}$.

Evaluation of Imaging Performance of Phase Shift Mask Depending on Reflectivity with Sub-resolution Assist Feature in EUV Lithography (SRAF를 적용한 극자외선 노광기술용 위상 변위 마스크의 반사도에 따른 이미징 특성 연구)

  • Jang, Yong Ju;Kim, Jung Sik;Hong, Seongchul;Cho, HanKu;Ahn, Jinho
    • Journal of the Semiconductor & Display Technology
    • /
    • v.14 no.3
    • /
    • pp.1-5
    • /
    • 2015
  • In photolithography process, resolution enhancement techniques such as optical proximity correction (OPC) and phase shift mask (PSM) have been applied to improve resolution. Especially, sub-resolution assist feature (SRAF) is one of the most important OPC to enhance image quality including depth of focus (DOF). However, imaging performance of the mask could be varied with the diffraction order amplitude changed by inserting SRAF. Therefore, in this study, we investigated the imaging properties and process margin of attenuated PSM with SRAF. Reflectivities of attenuated PSMs at 13.5 nm were 3, 6, 9% and simulation was performed by $PROLITH^{TM}$. As a result, aerial image properties and DOF as well as diffraction efficiency were improved by increasing the reflectivity of attenuated PSM. Additionally, printed critical dimension variations depending on SRAF width and space error were also reduced for attenuated PSM with high reflectivity. However, SRAF could be printed when reflectivity of attenuated PSM is high enough. In conclusion, optimization of reflectivity of attenuated PSM and SRAF to prevent side-lobe from being printed is needed to be considered.

Design of Optical Filter with Multilayer Slab/Fiber Structure (다층 슬랩-광섬유접속구조를 갖는 광필터의 설계)

  • Jeoung, Chan-Gwoun;Kang, Young-Jin;Kim, Sun-Youb
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.6
    • /
    • pp.1369-1375
    • /
    • 2007
  • The recent, a large capacity of telecommunication networks is required in order to it is in proportion to capacity of information communication increase and to satisfy a demand because of the demand about Internet, a multimedia service of internet, Video of internet protocol(VoIP), Audio/Video streaming. As a result, DWDM(Dense Wavelength Division Multiplexing)technologies are emerging to be a prevailing the method of solving it without additional optical fiber network building and high-speed equipment. Therefore this thesis proposed the optical filter of fiber/multilayer slab coupled structure combining it to multilayer slab waveguide by polishing the cladding of one side of fiber to design the optical filter having these functions. When a separation distance of fiber and slab was $3{\mu}m$, The optical filter proposed as the simulation result was satisfied with a DWDM filter characteristic with FWHM of 0.1nm on TM mode and TE mode as 32nm polarization independence in a communication window of $1.3{\mu}m$ when center wavelength was each ${\lambda}_0=1.274755{\mu}m$ and ${\lambda}_0=1.30591{\mu}m$.

  • PDF

Bending Creep of Glulam and Bolted Glulam under Changing Relative Humidity

  • PARK, Junchul;SONG, Yojin;HONG, Soonil
    • Journal of the Korean Wood Science and Technology
    • /
    • v.48 no.5
    • /
    • pp.676-684
    • /
    • 2020
  • This study was carried out in order to evaluate the bending creep deflection of glulams and bolted glulams beam-to-beam connection with steel-gusset plates and bolts under changing relative humidity. The two types of glulam beams (130 mm in width, 175 mm in thickness, and 3000 mm in length) used in this study were made from domestic larch and composed of seven layers. The gussets were made of 8-mm-thick steel plates. Creep testing was conducted under constant loads in an uncontrolled environment. The test was carried out in a room that was well ventilated through a window. The creep test specimens were loaded for 33,000 hours. A bending creep test for the glulams was conducted through four-point loading. The applied stresses were 20% and 30% of the MOR in the static bending test for the glulam and bolted glulam, respectively. After 33,000 hours, the creep deflection of the glulam at a 20% stress level increased by 39% to 99%, while the creep deflection of the glulam at a 30% stress level increased by 27% to 67%, as compared with instantaneous elastic deflection. The relative creep increased during autumn and winter, and recovered during spring and summer. The relative creep of the bolted glulams was changed abruptly by loading up to 5,000 hours, but stabilized after 5,000 hours, and then gradually increased until 33,000 hours. The relative creep of the bolted glulam increased 2.11 times on average after 33,000 hours.

Optical and Electrical Properties of InAs Sub-Monolayer Quantum Dot Solar Cell

  • Han, Im-Sik;Park, Dong-U;No, Sam-Gyu;Kim, Jong-Su;Kim, Jin-Su;Kim, Jun-O
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.196.2-196.2
    • /
    • 2013
  • 본 연구에서는 분자선 에피택시 (MBE)법으로 성장된 InAs submonolayer quantum dot (SML-QD)을 태양전지에 응용하여 광학 및 전기적 특성을 평가하였다. 본 연구에서 사용된 양자점 태양전지(quantum dot solar cell, QDSC)의 구조는 n+-GaAs 기판 위에 n+-GaAs buffer와 n-GaAs base layer를 차례로 성장 한 후, 활성영역에 InAs/InGaAs SML-QD와 n-GaAs spacer layer를 8주기 형성하였다. 그 위에 p+-GaAs emitter, p+-AlGaAs window layer를 성장하고 ohmic contact을 위하여 p+-GaAs 를 성장하였다. SML-QD 구조의 두께는 0.3 ML 이며, 이때 SML-QD의 적층수를 4 stacks 으로 고정하였다. SML-QD 와의 비교를 위하여 2.0 ML크기의 InAs자발 형성 양자점 태양전지(SK-QDSC)과 GaAs 단일 접합 태양전지 (reference-SC)를 동일한 성장조건에서 제작하였다. PL 측정 결과, 300 K에서 SML-QD의 발광 피크는 SK-QD 보다 고에너지에서 나타나는데(1.349 eV), 이것은 SML-QD가 SK-QD보다 작은 크기를 가지기 때문으로 사료된다. SML-QD는 single peak를 보이는 반면, SK-QD는 dual peaks (1.112 / 1.056 eV)을 확인하였다. SML-QD의 반치폭(full width at half maximum, FWHM)이 SK-QD에 비하여 작은 것으로 보아 SML-QD가 SK-QD보다 양자점 크기 분포의 균일도가 높은 것으로 해석된다. Illumination I-V 측정 결과, SML-QDSC의 개방 전압(VOC) 과 단락전류밀도(JSC)는 SK-QDSC의 값과 비교해 보면, 각각 47 mV와 0.88 mA/cm2만큼 증가하였다. 이는 SK-QD보다 상대적으로 작은 크기를 가진 SML-QD로 인해 VOC가 증가되었으며, SML-QD가 SK-QD 보다 태양광을 흡수할 수 있는 영역이 비교적 적지만, QD내에 존재하는 energy level에서 탈출 할 수 있는 확률이 더 높음으로써 JSC가 증가한 것으로 분석 된다.

  • PDF

Experimental Analysis of Bubble Dynamics Induced by Pulsed-Laser Heating of Absorbing Liquid (흡광 액체의 펄스 레이저 가열에 의해 생성된 기포 거동의 실험적 해석)

  • Jang Deok-Suk;Hong Jong-Gan;Choa Sung-Hoon;Kim Dong-Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.5 s.248
    • /
    • pp.413-421
    • /
    • 2006
  • The bubble dynamics induced by direct laser heating is experimentally analyzed as a first step to assess the technical feasibility of laser-based ink-jet technology. To understand the interaction between laser light and ink, the absorption spectrum is measured for various ink colors and concentrations. The hydrodynamics of laser-generated bubbles is examined by the laser-flash photography. When an Ar ion laser pulse (wavelength 488 nm) with an output power up to 600 mW is incident on the ink solution through a transparent window, a hemispherical bubble with a diameter up to ${\sim}100{\mu}m$ can be formed with a lifetime in a few tens of microsecond depending on the laser power and the focal-spot size. Parametric study has been performed to reveal the effect of laser pulse width, output power, ink concentration, and color on the bubble dynamics. The results show that the bubble generated by a laser pulse is largely similar to that produced by a thin-film heater. Consequently, the present work demonstrates the feasibility of developing a laser-actuated droplet generation mechanism for applications in ink-jet print heads. Furthermore, the results of this work indicate that the droplet generation frequency is likely to be further increased by optimizing the process parameters.

Design of Optical Filter Structure for DWDM (DWDM을 위한 광필터의 구조)

  • Jeoung, Chan-Gwoun;Ra, Yoo-Chan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.7
    • /
    • pp.1359-1366
    • /
    • 2007
  • The recent, a large capacity of communication is required in order to it is in proportion to capacity of information communication increase and to satisfy a demand because of the demand about Internet, a multimedia service of Video of internet protocol(VoIP), Audio/Video steaming. DWDM(Dense Wavelength Division Multiplexing) technique has been emerged as the method of solving it without additional optical fiber network building and hish-speed equipment. Therefore this thesis proposed the optical filter of fiber/multilayer slab coupled structure combining it to multilayer slab waveguide by polishing the cladding of one side of fiber to design the optical filter having these functions. The optical filter proposed as the simulation result satisfies DWDM filter characteristic; 1) when the separation distance between fiber and slab is $4.15{\mu}m$ at the communication window of $1.5{\mu}m$, the polarization independence is 65nm, 2) when the center wavelengths about TM mode and TE mode are each ${\lambda}_0=1.54946\;{\mu}m$ and ${\lambda}_0=1.6144\;{\mu}m$ and, FWHM(Full at Half Maximun) is 0.1nm.

Assessment of Coronary Stenosis Using Coronary CT Angiography in Patients with High Calcium Scores: Current Limitations and Future Perspectives (높은 칼슘 점수를 가진 환자에서 관상동맥 CT 조영술을 이용한 협착 평가의 한계와 전망)

  • Doo Kyoung Kang
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.2
    • /
    • pp.270-296
    • /
    • 2024
  • Coronary CT angiography (CCTA) is recognized for its role as a gatekeeper for invasive coronary angiography in patients suspected of coronary artery disease because it can detect significant coronary stenosis with high accuracy. However, heavy plaque in the coronary artery makes it difficult to visualize the lumen, which can lead to errors in the interpretation of the CCTA results. This is primarily due to the limited spatial resolution of CT scanners, resulting in blooming artifacts caused by calcium. However, coronary stenosis with high calcium scores often requires evaluation using CCTA. Technological methods to overcome these limitations include the introduction of high-resolution CT scanners, the development of reconstruction techniques, and the subtraction technique. Methods to improve reading ability, such as the setting of appropriate window width and height, and evaluation of the position of calcified plaque and residual visibility of the lumen in cross-sectional images, are also recommended.

The Understanding and Application of Noise Reduction Software in Static Images (정적 영상에서 Noise Reduction Software의 이해와 적용)

  • Lee, Hyung-Jin;Song, Ho-Jun;Seung, Jong-Min;Choi, Jin-Wook;Kim, Jin-Eui;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.54-60
    • /
    • 2010
  • Purpose: Nuclear medicine manufacturers provide various softwares which shorten imaging time using their own image processing techniques such as UlatraSPECT, ASTONISH, Flash3D, Evolution, and nSPEED. Seoul National University Hospital has introduced softwares from Siemens and Philips, but it was still hard to understand algorithm difference between those two softwares. Thus, the purpose of this study was to figure out the difference of two softwares in planar images and research the possibility of application to images produced with high energy isotopes. Materials and Methods: First, a phantom study was performed to understand the difference of softwares in static studies. Various amounts of count were acquired and the images were analyzed quantitatively after application of PIXON, Siemens and ASTONISH, Philips, respectively. Then, we applied them to some applicable static studies and searched for merits and demerits. And also, they have been applied to images produced with high energy isotopes. Finally, A blind test was conducted by nuclear medicine doctors except phantom images. Results: There was nearly no difference between pre and post processing image with PIXON for FWHM test using capillary source whereas ASTONISH was improved. But, both of standard deviation(SD) and variance were decreased for PIXON while ASTONISH was highly increased. And in background variability comparison test using IEC phantom, PIXON has been decreased over all while ASTONISH has shown to be somewhat increased. Contrast ratio in each spheres has also been increased for both methods. For image scale, window width has been increased for 4~5 times after processing with PIXON while ASTONISH showed nearly no difference. After phantom test analysis, ASTONISH seemed to be applicable for some studies which needs quantitative analysis or high contrast, and PIXON seemed to be applicable for insufficient counts studies or long time studies. Conclusion: Quantitative values used for usual analysis were generally improved after application of the two softwares, however it seems that it's hard to maintain the consistency for all of nuclear medicine studies because result images can not be the same due to the difference of algorithm characteristic rather than the difference of gamma cameras. And also, it's hard to expect high image quality with the time shortening method such as whole body scan. But it will be possible to apply to static studies considering the algorithm characteristic or we can expect a change of image quality through application to high energy isotope images.

  • PDF

A Computed Tomography-Based Anatomic Comparison of Three Different Types of C7 Posterior Fixation Techniques : Pedicle, Intralaminar, and Lateral Mass Screws

  • Jang, Woo-Young;Kim, Il-Sup;Lee, Ho-Jin;Sung, Jae-Hoon;Lee, Sang-Won;Hong, Jae-Taek
    • Journal of Korean Neurosurgical Society
    • /
    • v.50 no.3
    • /
    • pp.166-172
    • /
    • 2011
  • Objective : The intralaminar screw (ILS) fixation technique offers an alternative to pedicle screw (PS) and lateral mass screw (LMS) fixation in the C7 spine. Although cadaveric studies have described the anatomy of the pedicles, laminae, and lateral masses at C7, 3-dimensional computed tomography (CT) imaging is the modality of choice for pre-surgical planning. In this study, the goal was to determine the anatomical parameter and optimal screw trajectory for ILS placement at C7, and to compare this information to PS and LMS placement in the C7 spine as determined by CT evaluation. Methods : A total of 120 patients (60 men and 60 women) with an average age of $51.7{\pm}13.6$ years were selected by retrospective review of a trauma registry database over a 2-year period. Patients were included in the study if they were older than 15 years of age, had standardized axial bone-window CT imaging at C7, and had no evidence of spinal trauma. For each lamina and pedicle, width (outer cortical and inner cancellous), maximal screw length, and optimal screw trajectory were measured, and the maximal screw length of the lateral mass were measured using m-view 5.4 software. Statistical analysis was performed using Student's t-test. Results : At C7, the maximal PS length was significantly greater than the ILS and LMS length (PS, $33.9{\pm}3.1$ mm; ILS, $30.8{\pm}3.1$ mm; LMS, $10.6{\pm}1.3$; p<0.01). When the outer cortical and inner cancellous width was compared between the pedicle and lamina, the mean pedicle outer cortical width at C7 was wider than the lamina by an average of 0.6 mm (pedicle, $6.8{\pm}1.2$ mm; lamina, $6.2{\pm}1.2$ mm; p<0.01). At C7, 95.8% of the laminae measured accepted a 4.0-mm screw with a 1.0 mm of clearance, compared with 99.2% of pedicle. Of the laminae measured, 99.2% accepted a 3.5-mm screw with a 1.0 mm clearance, compared with 100% of the pedicle. When the outer cortical and inner cancellous height was compared between pedicle and lamina, the mean lamina outer cortical height at C7 was wider than the pedicle by an average of 9.9 mm (lamina, $18.6{\pm}2.0$ mm; pedicle, $8.7{\pm}1.3$ mm; p<0.01). The ideal screw trajectory at C7 was also measured ($47.8{\pm}4.8^{\circ}$ for ILS and $35.1{\pm}8.1^{\circ}$ for PS). Conclusion : Although pedicle screw fixation is the most ideal instrumentation method for C7 fixation with respect to length and cortical diameter, anatomical aspect of C7 lamina is affordable to place screw. Therefore, the C7 intralaminar screw could be an alternative fixation technique with few anatomic limitations in the cases when C7 pedicle screw fixation is not favorable. However, anatomical variations in the length and width must be considered when placing an intralaminar or pedicle screw at C7.