• 제목/요약/키워드: Window performance

검색결과 1,373건 처리시간 0.029초

차폐계수와 창면적비에 따른 공동주택의 건물에너지효율등급 평가 (The Building Energy Efficiency Rating Evaluation of Apartment depending on SC and Window area ratio)

  • 장철용;한혜심;이진숙
    • 한국태양에너지학회 논문집
    • /
    • 제30권5호
    • /
    • pp.38-43
    • /
    • 2010
  • Enhancement of exterior's insulation performance like wall or window etc. is general way for building's energy efficient and thermal performance. But exterior's opening plan is important for minimizing the energy consumption and heat loss. In this paper, energy saving rate will be analyzed and compared considering the window area's rate and window's SC(Shading Coefficient) in a apartment with Building Energy Efficiency Rating System's evaluation tool. In the process of evaluation, energy saving rate is measured at each stage of the window area's rate from 20% to 60% every 10% term and the shading coefficient value from 1.0 to 0.6. As a result of this research, energy saving evaluation could not be measured exactly with existing evaluation tool. Accord this research, Building Energy Rating System's evaluation range is needed to be broaden for exact evaluation of energy saving rate.

주거용 건물의 창호에너지평가시스템에 관한 연구 (A Study on the Window Energy Rating Systems in Residential Buildings)

  • 김동윤;임희원;신우철
    • KIEAE Journal
    • /
    • 제16권2호
    • /
    • pp.33-41
    • /
    • 2016
  • Purpose: The window energy rating system was developed in early 1990's and various kind of rating system has been implemented in advanced country such as Europe, Australia, Canada and the US since 2000. In Korea, the Energy Consumption Efficiency Rating Indication System has been implemented to promote supply of high efficiency window since July 2012. Normally, the window energy rating system based on heat balance which considers both thermal losses and solar heat gain is used and applied only to residential buildings. However, the system used nationally only considers thermal losses and is applied to every building regardless of its usage. Therefore, in this study, we indicated problems of domestic window energy rating system and looked for improvements. Method: We analyzed thermal performance of various windows through dynamic simulation applied to detached house and compared results with those of domestic and foreign rating system. Result : Thermal performance of south windows is more affected by SHGC than U-value, and that of north windows is also affected by SHGC a lot. The difference between the results of our study and current system is statistically significant. As a result, appropriate evaluation criteria which considers solar heat gain is required.

건축물의 창틀과 벽체 사이 열교 차단을 위한 단열공법 개발 (Development on Thermal Bridge Barrier Between Window Frame and Wall)

  • 박철용;김웅회;이상희
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 추계 학술논문 발표대회
    • /
    • pp.10-11
    • /
    • 2018
  • Internal Insulation system is applied to the most apartment building in Korea. However due to the importance of building energy enhanced the interest of the exernal insulation system. The extermal insulation system has better thermal performance because the thermal bridge through the structure are rarely formed. But the thermal bridge around the window decrease the thermal performance of the envelope system. Therefore the technology for reducing the thermal bridge around window improves energy efficiency of the building. In order to this it is necessary to minimize the thermal bridge around window of building. In this study it is aimed to minimize the thermal bridge around the window of building. It was confirmed that the use of thermal bridge barrier imporved the heat transfer rate by 64% or more and the condensation reduction phenomenon by 42% or more compared with the exist technology. These thermal bridge barrier will be used as the main technology to improve the energy efficiency of building.

  • PDF

공동주택의 판상형과 타워형 에너지 성능 비교 분석 (Energy Performance Analysis the Common House Pansang Type and Tower)

  • 윤성민;이경희;안영철
    • 동력기계공학회지
    • /
    • 제17권3호
    • /
    • pp.57-64
    • /
    • 2013
  • This study focus on the analysis of the energy performance in accordance with apartment houses arrangement type by using Ecotect Analysis. Korea, energy-poor country, the rate of dependence on imports amount to 94%, have to reduce energy consumption part of building except in industry and transport which affect the economic. Apartment houses are built in various forms in order to reduce energy, are modelled in each window area ratio, shape, orientation, climate through simulation. Through this study, we can analyze energy performance by form, window area ratio, orientation, climate change and know the optimal elements by the form. In particular, although there have been studied research on the window area ratio and research related to the arrangement form, determined that the information on the regional climate characteristics and the direction of placement is less than existing research. To supplement those problem, adding to seven direction(West, S-60-W, S-30-W, South, S-30-E, S-60-E, East) and climatic element(southern region) is characteristic of this study. The form of apartment houses was modelled for apartment houses built in the 10 years since. And each modeling were analyzed by Ecotect Analysis.

Dual Band Optical Window (DBW) for Use on an EO/IR Airborne Camera

  • Park, Kwang-Woo;Park, Sang-Yeong;Kim, Young-Soo;Kim, Ki-Ho;Choi, Young-Soo
    • Journal of the Optical Society of Korea
    • /
    • 제16권1호
    • /
    • pp.63-69
    • /
    • 2012
  • This paper presents a method to derive the theoretical requirements for the development of a 400 mm optical window that transmits dual-band wavelengths and had a stable structure. We also present design and fabrication results. Among the required specifications, the surface figure error was defined by the transmitted wavefront deformation (TWD), ${\lambda}$/15 rms at 632.8 nm. This value was derived by estimating the predicted performances with respect to five independent items that could cause system performance degradation and then calculating the required wavefront error (WFE) to satisfy the performance goals. We measured the image resolution at each performance level to trace and verify the requirements. The article also describes a design optimization process that could minimize the weight and volume of the optical window attached to the payload securing the FOV of the camera. In addition, we accurately measured the deformation that occurred in the series of fabrication steps including processing, coating, assembly, bonding and bolting, and investigated the effects by comparing them to the results of a simulation performed in advance to derive the predicted performance.

단열셔터를 적용한 구동창호의 에너지 절감 및 야간 난방성능 분석 (Analyses of Energy Savings and Night Heating Performance of a Movable Thermal Insulation Shuttered Window)

  • 이장만;조수;임상훈;송규동
    • 설비공학논문집
    • /
    • 제25권3호
    • /
    • pp.150-155
    • /
    • 2013
  • Usually, a window tends to have a lower thermal performance, than that of an ordinary wall. This study analyzes the enhancement of thermal performance of a window, when a Thermal Insulation Shutter is installed. The analyses were conducted at the laboratory, and with a full-scale mockup house, and the U-factor and heating load were examined. The laboratory results show that the U-factor increased by approximately 28%, when a Thermal Insulation Shutter was installed. The temperature difference was about $5^{\circ}C$, and this shows that the Thermal Insulation Shutter enhances the thermal performance of the window, when installed. The mockup house was used to calculate the heating load; the heating load was reduced by more than 41%, and shows that the installation of a Thermal Insulation Shutter is an effective way to reduce heating energy consumption.

3GPP 규격 오류 정정 부호 기법의 성능 평가 (Performance Analysis of Error Correction Codes for 3GPP Standard)

  • 신나나;이창우
    • 한국전자파학회논문지
    • /
    • 제15권1호
    • /
    • pp.81-88
    • /
    • 2004
  • 3GPP 표준의 오류 정정 부호 기법 중의 하나로 채택된 turbo 부호는 그 성능이 Shannon이 제시하는 이론적 한계 값에 근사하기 때문에 많은 관심을 받고 있다. 그러나 계산상의 복잡함과 많은 메모리를 요구한다는 단점이 있고 이를 보완할 수 있는 Log-MAP, Max-Log-MAP, SOVA, sliding window 알고리즘 등이 제안되었다. 본 논문에서는 turbo복호 알고리즘을 부동 소수점 연산과 고정 소수점 연산을 이용하여 구현하였을 때 성능을 해석하였다. 그리고 Log-MAP 알고리즘의 성능에 근사하는 효율적인 고정 소수점 구현 방법을 제안하였다. 이 방법을 Log-MAP과 sliding window 알고리즘에 적용하여 성능을 분석하였다.

Effects of collimator on imaging performance of Yttrium-90 Bremsstrahlung photons: Monte Carlo simulation

  • Kim, Minho;Bae, Jae Keon;Hong, Bong Hwan;Kim, Kyeong Min;Lee, Wonho
    • Nuclear Engineering and Technology
    • /
    • 제51권2호
    • /
    • pp.539-545
    • /
    • 2019
  • Yttrium-90 is a useful therapeutic radioisotope for tumor treatment because of its high-energy-emitting beta rays. However, it has been difficult to select appropriate collimators and main energy windows for Y-90 Bremsstrahlung imaging using gamma cameras because of the broad energy spectra of Y-90. We used a Monte Carlo simulation to investigate the effects of collimator selection and energy windows on Y-90 Bremsstrahlung imaging. We considered both MELP and HE collimators. Various phantoms were employed in the simulation to determine the main energy window using primary-to-scatter ratios (PSRs). Imaging performance was evaluated using spatial resolution indices, imaging counts, scatter fractions, and contrast-to-noise ratios. Collimator choice slightly affected energy spectrum shapes and improved PSRs. The HE collimator performed better than the MELP collimator on all imaging performance indices (except for imaging count). We observed minor differences in SR and SF values for the HE collimator among the five simulated energy windows. The combination of an HE collimator and improved-PSR energy window produced the best CNR value. In conclusion, appropriate collimator selection is an important component of Bremsstrahlung Y-90 photon imaging and main energy window determination. We found HE collimators to be more appropriate for improving the imaging performance of Bremsstrahlung Y-90 photons.

미래교육 환경변화에 따른 학교시설의 실내 바닥재 및 창호재에 관한 연구 (A Study on the Inner Window & Floor Materials of Educational Facilities According to the Environmental Variation of Future Education)

  • 유택동;조진일;이호진
    • 교육녹색환경연구
    • /
    • 제3권1호
    • /
    • pp.46-59
    • /
    • 2003
  • In this study, analyzing class method, curriculum and demand performance of materials and user according to the 7th educational curriculum which, it is surveyed that materials design performance standards of floor and window suitable to future educational environment. Based on this study, It is needed for development of special materials suitable educational facilities, making standards fitting demand, study of variable and special field for educational facilities, study for security of objective data of materials, study of performance evaluation method subdivided, and desirable positive use of intimate environmental materials.

  • PDF

고효율에너지기자재 고기밀성 단열창호의 단열성능 평가 연구 (A Evaluation Analysis on Thermal Performance of High Airtight and Insulated Window of High Efficiency Energy Equipment)

  • 장철용;방주영
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.227-230
    • /
    • 2009
  • Currently the country's foreign energy dependence reaches approximately 97% and the total energy consumption percentage of buildings(commercial and domestic parts) reaches approximately 24%. Building energy saving by enhanced insulation will be very important issue. Therefore, the solution is required to reduce energy loss and increasing displeasure caused by excessive influx of solar energy through windows, to solve the problems like decoloration on indoor furniture an clothes by harmful ultraviolet rays, air conditioning and increased cost. This research used for commercialization and ills semination by basic information through a evaluation on insulation performance of the window of high efficiency energy equipment which can improve the insulation performance.

  • PDF