고효율 로이유리 창호의 정량적 단열성능 평가 (An Evaluation for the Quantitative Thermal Performance of High Energy Efficiency Low-e Window)

  • 최경석;최현중;강재식;양관섭;이숭언
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.970-975
    • /
    • 2006
  • In the high oil prices age, intensification of energy efficiency promotion in the building sector is required. Windows are dominating large percentage whole building loads, and are regarding as the primary target of energy efficiency. The purpose of this study is to draw up a technical counterplan for the intensification of windows energy efficiency and spread promotion by quantitative thermal performance with KS test method for a comparison between the general Pair glass windows and the Low-e pair glass windows.

  • PDF

국가등록문화재 공주제일교회 스테인드글라스 구조재의 재질특성과 물성 평가 (Evaluation of Physical Properties and Material Characterization for Structural Frame at the Stained Glass Windows to Gongju Jeil Church of the Registered Cultural Heritage in Korea)

  • 박보영;양혜리;이찬희
    • 자원환경지질
    • /
    • 제56권1호
    • /
    • pp.103-114
    • /
    • 2023
  • 공주제일교회 기독교박물관은 1931년에 초축되었으며 한국전쟁으로 상당 부분 파손되었으나 벽체와 굴뚝 등이 보존되었다. 이 건물은 1956년 예배당을 재건하며 신축이 아닌 파손된 부분의 보수를 통해 원형을 유지하고 있다는 점에서 건축학적으로 높은 가치가 있다. 스테인드글라스는 1979년에 설치하였으며, 덩어리유리를 사용하는 달드베르(Dalle de Verre) 방식으로 큰 의미가 있다. 그러나 일부 스테인드글라스에서는 다양한 균열과 쪼개짐이 나타나고 색유리를 지지하는 줄눈에는 수직 및 수평균열이 확인되는 등 부분적인 손상을 입었다. 스테인드글라스의 구조재로는 철제 틀과 이를 충전한 시멘트 모르타르가 사용되었으며, 부분적으로 풍화작용에 따라 철제의 부식과 모르타르의 균열 및 입상분해가 나타난다. 줄눈재에서는 Ca과 S의 함량이 높아 석고를 혼화재로 사용하였음을 지시하며, 석고는 능형으로 성장하며 다발모양을 이루고 있는 것으로 보아 재결정작용을 거친 것으로 판단된다. 줄눈재의 초음파속도 모델링 결과, 입구 좌우창의 속도는 800~1,600㎧ 범위로 상대적으로 취약하며, 제단의 좌창 우측 하단과 중앙창 좌측 상단도 1,000~1,800㎧로 나타나 상대적으로 낮은 물성을 보였다. 또한 줄눈재와 표면오염물에서는 석회 모르타르의 중성화에서 생성되는 석고화합물이 검출되었다. 이와 같은 염류는 동결 및 융해작용에 따라 줄눈재의 손상을 일으킬 수 있어 적절한 예방보존이 필요하다. 스테인드글라스와 줄눈재에는 다양한 손상유형이 복합적으로 나타나고 있어 임상실험을 통해 맞춤형 보존처리를 검토해야 할 것이다.

전산유체 해석을 통한 슬림형 이중외피 창호의 태양열 취득량 분석 - 높은 태양고도 및 하절기 냉방조건에서의 자연환기구 적용 및 창문 조절 방식별 비교 - (Numerical analysis of solar heat gain on slim-type double-skin window systems - Heat transfer phenomena with opening of windows and vent slot in summer condition -)

  • 박지호;오은주;조동우;조경주;유정연
    • KIEAE Journal
    • /
    • 제17권1호
    • /
    • pp.69-75
    • /
    • 2017
  • Purpose: Heat transfer analysis of recently developed 'slim type double-skin system window' were presented. This window system is designed for curtain wall type façade that main energy loss factor of recent elegant buildings. And the double skin system is the dual window system integrated with inner shading component, enclosed gap space made by two windows when both windows were closed and shading component effectively reflect and terminate solar radiation from outdoor. Usually double-skin system requires much more space than normal window systems but this development has limited by 270mm, facilitated for curtain wall façade buildings. In this study, we estimated thermophysical phenomena of our double-skin curtain wall system window with solar load conditions at the summer season. Method: A fully 3-Dimentional analysis adopted for flow and convective and radiative heat transfer. The commercial CFD package were used to model the surface to surface radiation for opaque solid region of windows' frame, transparent glass, fluid region at inside of double-skin and indoor/outdoor environments. Result: Steep angle of solar incident occur at solar summer conditions. And this steep solar ray cause direct heat absorption from outside of frame surface rather than transmitted through the glass. Moreover, reflection effect of shading unit inside at the double-skin window system was nearly disappeared because of solar incident angle. With this circumstances, double-skin window system effectively cuts the heat transfer from outdoor to indoor due to separation of air space between outdoor and indoor with inner space of double-skin window system.

이온강화법을 이용한 소다라임 글라스 강화에 관한 연구 (A study on the strengthening of Sodalime glass using ion exchange method)

  • 안해원;오재호;권수근;최성대
    • 한국기계가공학회지
    • /
    • 제13권6호
    • /
    • pp.145-151
    • /
    • 2014
  • The glass used for mobile display windows is required to have high strength. Chemical strengthening by means of ion exchange is widely used glass. The depth of the layer and the compressed stress are affected by tempering temperature and time. The purpose of this study is to investigate the range of DOL and CS, which to less breakage during reliability tests such as the ball drop test, hole drop test, 3-point bending test, drop test, and tumble test with Soda-lime Glass.

차량 윈도우 리프트 음질 고급감 향상을 위한 음질 지수 제작 및 개선에의 응용 (The Development and Application of Sound Quality Index for the Improving Luxury Sound Quality of Road Vehicle Power Window System)

  • 김성현;박동철;조현호;성원찬;강연준
    • 한국소음진동공학회논문집
    • /
    • 제24권2호
    • /
    • pp.108-116
    • /
    • 2014
  • With the increasing the importance of emotional quality of vehicle, the sound quality of systems with electric motor components has become increasingly important. Electric motors are used for windows, seats, sun roof, mirrors, steering columns, windshield wiper and climate control blowers, etc. In this paper, a study was conducted to identify sound quality factors that contribute to customer's satisfaction and preference of the window lift system. Jury test for subjective evaluation was carried out and sound quality index was developed. Averaged sound pressure level and sharpness were significant factors when glass moves down. Also, maximum loudness at stop section and averaged loudness were significant factor when glass moves up. Next, noise source identification was carried out using beam forming method during glass transferred section and impulsive noise at stop section. Several improvement methods were applied using the source identification result. And finally, the degree of sound quality improvement was judged using sound quality index.

나노 기공성 단열 실리카 모노리스 제조 및 특성 연구 (Preparation and characterization of nanoporous monolith with high thermal insulation performance)

  • 최현묵;김성우
    • 한국응용과학기술학회지
    • /
    • 제31권1호
    • /
    • pp.83-91
    • /
    • 2014
  • 본 연구에서는 졸-겔, 용매치환, 표면개질, 상압건조 공정과 계면활성제에 의한 템플레이팅(templating) 공법 및 소결 공정을 이용하여 실리카 에어로겔 모노리스와 메조포러스 실리카 모노리스를 각각 합성하였다. 제조된 두 종류의 실리카 모노리스는 균열이 없이 비교적 투명하였으며, 매우 높은 기공율(92-94%) 및 비표면적($800-840m^2/g$)과 수 십 nm 수준의 기공 크기를 갖는 것으로 확인되었다. 표면개질을 적용한 실리카 에어로겔 샘플이 스피링백 효과로 인하여 메조포러스 실리카 모노리스에 비해 더욱 미세하고 균질한 나노 기공 구조를 보였을 뿐만 아니라, 그 단열 성능도 더욱 우수한 것으로 나타났다. 본 연구를 통해 합성된 두 종류의 실리카 모노리스를 중간층으로 적용한 복층 창유리의 단열 성능을 측정된 모노리스의 열전도도와 이론식을 근거로 조사한 결과, 기존의 상업적으로 응용되는 공기층 삽입 복층 창유리에 비해 우수한 단열 성능을 보이는 것으로 나타났다.

아르곤가스 주입 단열 복층유리 내구성 평가 (Evaluation for Argon gas-filled Insulating glass units)

  • 김경남;정진영;배기선
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 추계 학술논문 발표대회
    • /
    • pp.128-131
    • /
    • 2013
  • Energy losses through windows and doors are big problems in the construction industry. For glass only, it has takes the largest portion of mass from window assembly and it responsible for 24 ~ 45% of energy loss from total building energy loss. Insulating glass unit should maintain their basic functions during their working life in order to contribute positively for global warming issue. There have been many research works for improving insulating glass unit durability. But it is not easy job to fulfill the requirements because insulating glass units composed of many components. So, overall it is required to have right qualify control procedures starting from material selection to fabrication, shipping and installation to the customer site. In this report, we have reviewed the durability of insulating glass unit made from different grades of sealing materials based on globally accepted industry codes such as EN1279. ASTM E 2190 and Locally available code. KS L 2003. The result showed that there is a relationship between the mechanical properties of insulating glass 2nd sealant and the durability of the units.

  • PDF

완강기의 설치 실태 분석 및 개선에 관한 연구 (A Study on Analysis of Installation on the Actual State and Improvement about a Descending Life Line)

  • 최용혁;박성진;김태구;김광일
    • 한국화재소방학회논문지
    • /
    • 제22권1호
    • /
    • pp.105-114
    • /
    • 2008
  • 본 연구에서는 2006년 개정소방법의 시행에 따라 다중이용업소 및 고층건물에 피난설비 중 피난기구로 설치가 의무화 되고 있는 '완강기'의 현재 나타난 설치상의 문제점을 조사해보고, 제시된 문제점들을 각 항목별로 나누어 원인 분석 및 개선사항을 제시하였다. 설문조사를 통하여 총 367건의 문제점이 지적되었으며, 다음과 같이 설치실태의 문제점이 나타났다. 완강기를 이용한 탈출이 부적합한 창문(34%), 관련문구 미부착(23.7%), 부적합한 설치장소(20%) 및 완강기의 파손(20%) 등으로 조사되었다. 특히 완강기 설치상 문제점으로 완강기를 이용한 탈출에 부적합한 창문이라는 사항이 가장 많이 제시되었기에 탈출 시 필요한 유리의 파괴에 관한 응력해석을 수행한 결과 완강기가 설치된 곳의 유리두께는 3,6 mm로 규정되어야 할 것으로 나타났다. 또한 기존의 소방법에 따른 형식적인 설치가 아닌 화재발생 시 인명을 보호하는 피난도구로써의 완강기 설치 및 사용이 가능할 수 있는 실질적인 완강기 설치상의 개선대책을 제시했다.

강풍에 대비한 창호보호장치의 보강성능 평가 (Evaluation of Reinforcing Performance of Window Protection Device Against Strong Wind)

  • 박원빈;김홍진
    • 한국풍공학회지
    • /
    • 제22권4호
    • /
    • pp.155-161
    • /
    • 2018
  • 현대 사회에서 도시화와 온난화로 인한 태풍 등 강풍에 의한 피해는 증가될 것으로 예상된다. 본 연구에서는 기 개발된 창호보호장치의 보강성능을 시험하기 위해 비 보강된 판유리와 보강된 판유리의 2점 가력실험과 등분포하중 실험을 수행하였다. 창호보호장치의 보강성능은 휨 성능평가를 토대로 평가하였다. 창호보호장치의 이론적 성능 산정은 탄성하중법과 처짐 곡선의 미분방정식을 이용한 수식해석과 Midas-Gen을 이용한 전산해석을 통해 수행하였다. 실험값과 이론 산정 값의 최대하중 가력시의 판유리 중앙부 최대 처짐 비교를 통해 산정방법의 유효성을 검토하였다. 창호보호장치 부착 시 실험조건하에서 40%까지의 응력감소효과와 동일 하중하에서 71.4%까지의 처짐 감소 효과가 있었다. 판유리를 보요소로 해석한 결과보다 판유리를 판 요소로 해석한 결과가 오차가 적으므로 성능 판단 시 가능하면 판 요소로 해석을 수행하는 것이 유리하다.