• Title/Summary/Keyword: Window glass

Search Result 223, Processing Time 0.023 seconds

The Experimental Study of Radiant Cooling Test System under Different Covers (복사냉각 시스템에서 커버의 영향)

  • Byun, Ki-Hong;Smith, Theodore F.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.11
    • /
    • pp.797-802
    • /
    • 2007
  • The effects of window cover on the performance of the plate type radiant cooling test system are studied. The cover materials tested are 2mm, 1mm, 0.7mm glass, Cokin 007 filter, and PVC film. The measurements are performed during the September nights of 2005 at the rooftop of the building in Seoul. The equivalent height of the building is about a building with twelve floors. The radiant cooling performance of the black painted and aluminum film coated plate are compared under no cover condition. Also the results are compared when the system has cover over the plate. In general, the covers reduce the radiant cooling temperature differences during the nighttime. Among these covers, the PVC film cover shows the best performance. In some cases, the plate with PVC film cover shows lower temperatures than the system without cover.

A Study on Safety Assessment of Semi-Submersible Catamaran's Bottom Glass (반잠수형 쌍동선의 수중관람창 안전성 평가)

  • Lee, Kyoung-Hoon;Kim, Yoo-Il
    • Journal of Korea Ship Safrty Technology Authority
    • /
    • s.36
    • /
    • pp.2-14
    • /
    • 2014
  • 수중관람창의 판 두께산정식의 유효성을 판단하기 위하여 ISO기준과 일본기준을 비교하고 쌍동선에 설치되는 관람창의 안전성을 평가하기 위해 상용 유한요소해석 프로그램인 ABAQUS를 이용하여 Plexiglass의 두께를 산정하였다. 그 결과를 KS V ISO 12216:2005에 제시된 응력과 처짐에 의한 두께 산정 기준에 따라 관람창의 압력시험을 실시하여 유한요소해석의 적합성을 판단하였다. 또한, 선박과 관람창 연결부(Framing부)는 ISO 11336-1:2012(E)에서 제시된 6가지의 Type중 볼트가 체결된 4가지 경우에 대한 구조해석을 실시하여 연결부의 타입을 결정하였다.

  • PDF

Characteristics of noise in HVAC duct for vehicle (차량용 공조덕트의 소음특성에 관한 연구)

  • Kim, Jae-Won;Kim, Jin-Min;Park, Jeong-Young
    • 유체기계공업학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.529-534
    • /
    • 2003
  • Comprehensive study on the system, including blower and ducts, of HVAC device of a vehicle has been carried out for improvements of noise characteristics. The parameters of design improvements are concerned with geometric informations such as the shape of ducts and presence of a windshield window. Test results show that noise level increasing the following order: HV (HD) < V (D) < BH ${\sim}$ BHV (BHD) < B (B, H, V, D denote for blower, heater unit, vent duct, defrost duct, respectively). The effects of windshield glass on the noise level in the case of defrost mode are pronounced and the effects of the geometry of ducts on the overall HVAC noise prove to be not small.

  • PDF

A Experimental Study on Artificial Illumination Control System Illuminated by Daylighting (자연채광을 이용한 인공조명의 제어방법에 관한 실험적 연구)

  • 차광석;김회서
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.8 no.1
    • /
    • pp.21-28
    • /
    • 1994
  • It is very important and necessary to predict luminous enviroment in an interior space. This paper has described about energy saving and evaluated interior visual environment in a office building having on/off turning control lighting system utilizing daylight. In order to predict the interior varior illumination distribution, the scale model was made and examined under various conditions, such ad difference of window glass, and color pattern of wall, floor, and also ceiling lighting system type. This paper suggests that basic fundamental data of lighting design performance in the concept and schematic stages of design.

  • PDF

Benchmarking of Single Image Reflection Removal Algorithms (단일 영상의 반사된 이미지 제거에 대한 벤치마킹 실험)

  • Lee, Yong-Hwan;Kim, Youngseop
    • Journal of the Semiconductor & Display Technology
    • /
    • v.18 no.4
    • /
    • pp.154-159
    • /
    • 2019
  • Undesirable negative image is occurred in photographs taken across partial reflections such as glass window and electronic display. Efficient removing reflections given a single image are in the spotlight in recent researches. This paper discusses and evaluates two published image reflection removal algorithms, and compares the performance of time and quality of those methods with a common dataset. As benchmarking test cases are presented, we propose to modify one of the methods to reduce the run-time with small effects on the similar image quality.

Implementation of Reflection Removal Algorithm on Mobile Device (모바일 장치에서 반사 잔상 제거 알고리즘 구현)

  • Lee, YuKyong;Lee, Yong-Hwan
    • Journal of the Semiconductor & Display Technology
    • /
    • v.20 no.1
    • /
    • pp.108-112
    • /
    • 2021
  • Undesired reflection removal from an image captured through glass window is widely needed with the prevalence of camera. In this paper, we present and implement a reflection removal algorithm, which is specially designed for smart devices. Our implementation requires smart phone application to take two input pictures of the same target, one with flash light on and another with flash light off. Then, we find a flash spot in the picture, match the features to align the input pictures, transform the color space, and finally combine the pictures. As the result, we get a resulting image with removed reflection, achieving the visually pleasant.

Development of detachable air-cap module for improving the performance of windows (창호 성능 개선을 위한 에어캡 탈부착형 모듈 개발)

  • Seo, Beomdong;Lee, Heangwoo;Seo, Janghoo;Kim, Yongseong
    • KIEAE Journal
    • /
    • v.17 no.1
    • /
    • pp.63-68
    • /
    • 2017
  • Purpose: Various studies to solve the problem of increased energy consumption in the buildings are being carried out recently. Especially, the economic feasibility and insulation performance of the air-cap have been verified so that various studies regarding the reduction of building energy consumption have been carried out. However, previous studies regarding the air-cap were only carried out based on the verification of its insulation performance according to the size and attachment position of the air-cap. Therefore, the purpose of this study is to suggest a detachable air-cap module for improving the performance of the windows, evaluate the performance based on cooling, heating and light environments and verify its effectiveness through a real-scale testbed. Method: In this study, the energy saving performance in the circumstance where there is no attachment of an air-cap (Case 1), the circumstance where there is the attachment of air-cap on the glass surface of window (Case 2) and the circumstance where there is the attachment of an air-cap on the window frame (Case 3) were compared in order to verify the performance of the detachable air-cap module (Case 4), and the electricity consumption of cooling, heating and lighting equipment to maintain the appropriate indoor temperature and Illuminance for each case was calculated and utilized as indicators for the performance evaluation. Result: The result of this study is as follows. 1) In this study, the detachable air-cap module which was easily detachable through the principle of the magnet was suggested. 2) When Case 4 is applied, the electricity consumption of cooling and heating equipment can be reduced by 27.5%, 13.2% and 3.4% in comparison with Case 1, Case 2 and Case 3 respectively. 3) When the air-cap is applied to the window, the lighting energy consumption increases by 4 % in comparison to the non application of the air-cap, and this factor or aspect should be considered when applying the air-cap. 4) According to the performance evaluation result in consideration of cooling, heating and light environments, Case 4 demonstrates an energy saving ratio of 22.6%, 10.6% and 2.7% in comparison to Case 1, Case 2 and Case 3 respectively, indicating that it is effective for improving the performance of windows.

Fabrication of 3-Step Light Transmittance-variable Smart Windows based on λ/2 Retardation Film (λ/2 Retardation Film을 이용한 3단계 투과율 가변 스마트윈도우 제작)

  • Il-Gu Kim;Ho-Chang Yang;Young-Min Park;Yo-Han Suh;Young Kyu Hong;Seung Hyun Lee
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.30 no.3
    • /
    • pp.78-82
    • /
    • 2023
  • A fabrication of smart windows with controllable visible light transmittance in three steps by using λ/2 retardation films based on a reactive mesogen (RM) material and polarizing films is demonstrated. The phase retardation films with a Δn·d value of λ/2 (λ: wavelength) convert the direction of a traveling light to the optical axis of the film symmetrically. In this work, the retardation characteristics according to the RM thickness were evaluated and henceλ/2 phase retardation film can be fabricated. The phase retardation film with Δn·d of 276.1 nm, which is close to λ/2 (=275 nm @550 nm), was fabricated. The light transmittance of a smart window with the structure of (polarizing film)/(glass)/(alignment layer)/(λ/2 retardation film) was measured in the transmission mode, half mode and blocking mode. The evaluation results show that the transmittance of the smart window can be controlled in three steps with 35.8%, 27.8%, and 18.2% at each mode, respectively. In addition, by fabricating a smart window with a size of 15×200 mm2, the feasibility of use in various fields such as buildings and automobiles was verified.

A Rapid Method for the Measurement of $^{222}Rn$ in Groundwater and Hot Spring Water using Ultra Low-Level Liquid Scintillation Counter and Pulse Shape Analysis (극저준위 액체섬광계수기와 파형분석법을 이용한 지하수 및 온천수중 $^{222}Rn$의 신속측정법)

  • Kim, Chang-Kyu;Kim, Cheol-Su
    • Journal of Radiation Protection and Research
    • /
    • v.20 no.2
    • /
    • pp.103-115
    • /
    • 1995
  • For the determination of $^{222}Rn$ in water by a very simple and time saving liquid scintillation counting method that does not require any chemical separation, an optimum analytical condition has been investigated. The optimum pulse shape analysis(PSA) level for the measurement of $^{222}Rn$ using LKB 1220 Quantulus liquid scintillation counter was 110 for Optiphase HiSafe3 cocktail and 90 for toluene-based cocktail. The counting efficiencies of $^{222}Rn$ in the window covering u spectra using Optiphase HiSafe3 cocktail were 282.2% for glass vial and 271.6% for Teflon vial, whereas the counting efficiencies in toluene-based cocktail were 262.3% and 247.5% for glass and Teflon vials, respectively. The minimum detectable activity(MDA) in the u window for a 60-min measurement with a Teflon vial using Optiphase HiSafe3 cocktail was $0.30Bq/{\iota}$. The analytical method studied from this work was also applied to the determination of $^{222}Rn$ in some groundwater and hot spring water samples.

  • PDF

Opto-Electrochemical Sensing Device Based on Long-Period Grating Coated with Boron-Doped Diamond Thin Film

  • Bogdanowicz, Robert;Sobaszek, Michał;Ficek, Mateusz;Gnyba, Marcin;Ryl, Jacek;Siuzdak, Katarzyna;Bock, Wojtek J.;Smietana, Mateusz
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.6
    • /
    • pp.705-710
    • /
    • 2015
  • The fabrication process of thin boron-doped nanocrystalline diamond (B-NCD) microelectrodes on fused silica single mode optical fiber cladding has been investigated. The B-NCD films were deposited on the fibers using Microwave Plasma Assisted Chemical Vapor Deposition (MW PA CVD) at glass substrate temperature of 475 ℃. We have obtained homogenous, continuous and polycrystalline surface morphology with high sp3 content in B-NCD films and mean grain size in the range of 100-250 nm. The films deposited on the glass reference samples exhibit high refractive index (n=2.05 at λ=550 nm) and low extinction coefficient. Furthermore, cyclic voltammograms (CV) were recorded to determine the electrochemical window and reaction reversibility at the B-NCD fiber-based electrode. CV measurements in aqueous media consisting of 5 mM K3[Fe(CN)6] in 0.5 M Na2SO4 demonstrated a width of the electrochemical window up to 1.03 V and relatively fast kinetics expressed by a redox peak splitting below 500 mV. Moreover, thanks to high-n B-NCD overlay, the coated fibers can be also used for enhancing the sensitivity of long-period gratings (LPGs) induced in the fiber. The LPG is capable of measuring variations in refractive index of the surrounding liquid by tracing the shift in resonance appearing in the transmitted spectrum. Possible combined CV and LPG-based measurements are discussed in this work.