• 제목/요약/키워드: Window glass

검색결과 223건 처리시간 0.02초

회의실 유리창 진동음의 음성 명료도 분석 (Speech Intelligibility Analysis on the Vibration Sound of the Glass Window of a Conference Room)

  • 김희동;김윤호;김석현
    • 한국소음진동공학회논문집
    • /
    • 제17권4호
    • /
    • pp.363-369
    • /
    • 2007
  • The purpose of the study is to obtain acoustical information to prevent eavesdropping of the glass window. Speech intelligibility was investigated on the vibration sound detected from the glass window of a conference room. Objective test using speech transmission index(STI) was performed to estimate quantitatively the speech intelligibility. STI was determined based on tile modulation transfer function(MTF) of the room-glass window system. Using Maximum Length Sequency(MLS) signal as a sound source, impulse responses of the glass window and MTF were determined by signals from accelerometers and laser doppler vibrometer. Finally, speech intelligibility of the interior sound and window vibration were compared under different sound pressure levels and amplifier gains to confirm the effect of measurement condition on the speech intelligibility.

회의실 유리창 진동음의 명료도 분석 (Speech Intelligibility Analysis on the Vibration Sound of the Window Glass of a Conference Room)

  • 김윤호;김희동;김석현
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 추계학술대회논문집
    • /
    • pp.150-155
    • /
    • 2006
  • Speech intelligibility is investigated on a conference room-window glass coupled system. Using MLS(Maximum Length Sequency) signal as a sound source, acceleration and velocity responses of the window glass are measured by accelerometer and laser doppler vibrometer. MTF(Modulation Transfer Function) is used to identify the speech transmission characteristics of the room and window system. STI(Speech Transmission Index) is calculated by using MTF and speech intelligibility of the room and the window glass is estimated. Speech intelligibilities by the acceleration signal and the velocity signal are compared and the possibility of the wiretapping is investigated. Finally, intelligibility of the conversation sound is examined by the subjective test.

  • PDF

레이저센서를 이용한 유리창 도청 및 도청방지기의 성능 평가 (Eavesdropping of the Glass Window Using a Laser Sensor and Performance Estimation of a Window Shaker)

  • 김석현;허욱;김희동
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.551-556
    • /
    • 2008
  • Possibility of the remote eavesdropping through window glass is investigated using a laser sensor. Various thicknesses and types of glass windows are excited by maximum length sequency (MLS) signal and the vibration sound is detected by a laser doppler vibrometer. Intelligibility of the detected sound is evaluated using the speech transmission index (STI), which is based on the modulation transfer function (MTF). In order to identify the disturbing effect, different level of disturbing wave is generated by an outside speaker and a window shaker attached on the glass window. On the different thickness of glass windows, decrease effect of the speech intelligibility is analysed.

  • PDF

회의실내 유리창 진동의 도청에 대한 연구 (A Study on the Eavesdropping of the Glass Window Vibration in a Conference Room)

  • 김석현;김윤호;허욱
    • 산업기술연구
    • /
    • 제27권A호
    • /
    • pp.55-60
    • /
    • 2007
  • Possibility of the eavesdropping is investigated on a conference room-glass window coupled system. Speech intelligibility analysis is performed on the eavesdropping sound of the glass window. Using MLS(Maximum Length Sequency) signal as a sound source, acceleration and velocity responses of the glass window are measured by accelerometer and laser doppler vibrometer. MTF(Modulation Transfer Function) is used to identify the speech transmission characteristics of the room and window system. STI(Speech Transmission Index) is calculated by using MTF and speech intelligibility of the vibration sound is estimated. Speech intelligibilities by the acceleration signal and the velocity signal are compared.

  • PDF

창호일체형 태양열 집열기 (Window Integrated Solar Collectors)

  • 박성배;임성환;박만귀
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 춘계학술발표대회 논문집
    • /
    • pp.61-65
    • /
    • 2009
  • Window integrated solar collector is to simply install inside of the existing double glass window frame. Double glass window frame is consist of inner glass of Low-E coating and Silver coating, and outer glass of low iron reinforced glass. In order to secure natural lighting in a room, only 50% of window frame is covered with solar collectors. Solar absorption or transmission rate varies seasonally depending on sun angles. Part of inner glass where right behind of the solar plate is covered with silver coating to increase absorption rate of solar plate. The collector is made of a copper serpentine where aluminum fins are soldering. To improve the effect of insulation of inside of the window frame is recommend vacuum. As a result, we are making the 3th sample and will archieve below $F_RU_L=7.5W/m^2^{\circ}C$ that is the account of heat lossed, and above $F_R({\tau}{\alpha})=0.45$.

  • PDF

공동주택 세대내 발코니 유형별 창호의 냉난방 에너지 성능분석 연구 (A Study on the Energy Performance Evaluation of Window System with the Balcony Types of Apartments)

  • 윤종호;안영섭;김병수;황상근
    • 한국태양에너지학회 논문집
    • /
    • 제27권1호
    • /
    • pp.83-90
    • /
    • 2007
  • Apartment balcony has been indiscreetly remodeled since the government permitted remodeling on January 2006. But remodeled balcony has a few problems such as increase of heating energy, surface condensation and cold draft. The reason of thermal problem is mainly caused by the window system in a extended balcony. The purpose of this study is to analyze heating and cooling energy and propose the efficient window types for the extended balcony area of a apartment building. 4 types of window system which have fairly high U value in Korea are investigated as follows ; double clear glass, double low-e glass, triple clear glass and triple low-e glass. Comparing double clear 91ass with double low-e glass, triple clear glass and triple low-e glass, simulation results show that 10%, 7% and 15% saving of total primary energy can be expected.

투과시스템의 광학특성을 고려한 복합적 외벽채광부의 성능평가에 관한 연구 (Design and Performance Evaluation of Hybrid Window Walls With Variable Transmittal Materials)

  • 도진석;김곤;김정태
    • KIEAE Journal
    • /
    • 제4권2호
    • /
    • pp.11-18
    • /
    • 2004
  • Growing use of entire glass facades with metal frames are popularly witnessed in modern building practices and design competition as well. In spite of architectural aesthetics and view to outdoors, environmental issues still exist in that kind of buildings. One of the solutions for the problems might be the use of functional glasses such as a heat-resistant glass or various tinted glasses for the glass walls. This paper aims to provide performance data related to the impact of various transmittal materials of window systems on the light distribution. A series of computer simulation deals with the basic geometrical and optical design elements of a commonly used all-glass facades. Additionally an experimental configuration of the vertical window is proposed for better result of daylighting. A window system equipped with an inner-light shelf can improve the uniformity of natural light in a space by reducing the level of illumination near the window and redirecting light deeply into the space.

구획 화재시 창유리 파괴 현상에 관한 실험적 연구 (A Experimental Study on Window Glass Breakage in Compartment Fires)

  • 이수경;김종훈;최종운;이정훈
    • 한국화재소방학회논문지
    • /
    • 제12권3호
    • /
    • pp.21-30
    • /
    • 1998
  • 본 연구는 실제 화재실험을 통하여 구획 화재 시 일어날 수 있는 창유리의 파괴 형태 및 시간 그리고 개구 조건과의 관계 등을 고찰하고자 했다. 화재 시 창유리의 파괴현상은 창호 유리 중간 부분과 프레입 안에 있는 유리부분의 현저한 온도차이로 인한 열웅력으로 일어남을 확인했다. 실험 1-3은 프레엄 내부와 유리면의 온도차가 233.4$^{\circ}C$ 였으며, 실험 2-1은 138$^{\circ}C$, 실험 2-2는 83.6$^{\circ}C$의 차이를 보였다. 파괴 발생 시 실내의 온도는 실험 2-1의 경우 434.4$^{\circ}C$, 실험 2-2는 83.6$^{\circ}C$의 차이 를 보였다. 파괴 발생 시 실내의 온도는 실험 2-1의 경우 434.4$^{\circ}C$, 실험 2-2는 440.6$^{\circ}C$ 실험 2-3 은 400.9$^{\circ}C$를 기록하여 화염이 직접 닿지 않는 경우의 균열은 400-50$0^{\circ}C$의 온도에서 발생한다. 화재로 인한 창유리(한글라스 플로탱 유리)는 1541.14kW의 화재에 노출되었을 시 열웅력에 의한 파괴가 일어나기는 하나 유리면이 파괴에 의해 개구부가 되지 않는다.

  • PDF

창의 경사도에 따른 열관류율 변화에 관한 연구 (A Study on the Change of Heat Transmission Coefficient According to the Degree of Windows Slope)

  • 황하진;이경희
    • 한국주거학회논문집
    • /
    • 제12권3호
    • /
    • pp.133-140
    • /
    • 2001
  • This study investigated the heat transmission coefficient through the experiment that the skylight, slope window of 60 degree and 30 degree consisted of pair glass and the double window of external window and internal window paper were suitable for heat insulation. As the result of experiment, the heat transmission coefficient of slope window was 1.06 times in the 60 degree, 1.18 times in the 30 degree and 1.31 times in the skylight as a standard lateral window. The heat transmission coefficient in the double window of external window and internal window paper was 3.017$\textrm{㎉}$/$\textrm{m}^2$.hr.$^{\cire}C$. The slope window was not suitable for the prescription by the increase of the heat transmission coefficient, so the user must pay attention to the treatment. This study investigated only the slope window of 12mm and 16mm pair glass and the double window of external window and internal window paper, study on the various pattern of window must be achived in a future.

  • PDF

유리창 도청방지 장치의 성능평가 (Performance Estimation of a Window Shaker)

  • 김석현;김희동;허욱
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.649-654
    • /
    • 2007
  • Eavesdropping prevention performance is evaluated on a commercial window shaker, which is used to prevent a glass window from eavesdropping. Speech transmission index (STI) is introduced in order to estimate quantitatively the speech intelligibility of the sound detected on the glass window. Objective test by IEC standard using modulation transfer function (MTF) is performed to determine STI. Using Maximum Length Sequency (MLS) signal as a sound source, MTF is measured by accelerometers and laser doppler vibrometer. STI under different level of disturbing wave are compared to confirm the disturbing effect on the speech intelligibility.

  • PDF