• 제목/요약/키워드: Window Frame

검색결과 229건 처리시간 0.027초

건축물 창호 프레임의 연소특성에 따른 방화성능 검증에 관한 실험적 연구 (An Experimental Study on the Verification of Fire Extinguishing Performance According to the Combustion Characteristics of Building Window Frame)

  • 이병흔;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 가을 학술논문 발표대회
    • /
    • pp.54-55
    • /
    • 2021
  • This study compared the fire safety standards for windows of Korea, the U.S. and Japan to prevent fire expansion through exterior wall openings, and conducted experiments using PVC and aluminum window frames, which are widely used in Korea.The experiment is KS F 2845 which combines frames of the same thickness and area with single-window form and 1 hour fire resistance glass with 8T thickness. Experiments showed that the PVC window was about 9 minutes and the aluminum window was about 26 minutes. However, in Korea, there are no test standards for windows installed at the opening of the exterior wall. In addition, fire safety standards for windows shall be established along with the designation of fire prevention zones.

  • PDF

CAM shift와 8방향 탐색 윈도우를 이용한 객체 추적 (Object Tracking Using CAM shift with 8-way Search Window)

  • 김남곤;이금분;조범준
    • 한국정보통신학회논문지
    • /
    • 제19권3호
    • /
    • pp.636-644
    • /
    • 2015
  • 이 논문에서는 CAM shift알고리즘과 8방향 탐색 위도우를 결합하여 객체의 추적 성능을 향상하는 방법과 추적에 이용되는 프레임의 수를 줄여 연산을 줄이는 방법을 제안한다. CAM shift는 대표적인 색상을 이용한 추적 방법이나 빠른 속도로 이동하는 물체를 추적하기 어려운 단점이 있다. 이를 해결하기 위해 추적 대상을 놓쳐버린 시점에서 마지막으로 추적에 성공한 시점의 정보를 이용하여 8방향 탐색을 실시하여 객체를 찾아 낸 후 CAM shift의 탐색 윈도우를 이동시켜 기존의 CAM shift로는 추적이 불가능한 고속 이동 물체에 대해서도 보다 정확한 추적이 가능하게 되었다. 또한 하드웨어의 발달로 초당 생산되어지는 프레임의 수가 증가하여 불필요한 연산이 증가하게 되었고, 이를 줄이기 위해 추적에 이용되는 프레임의 수를 줄여 연산을 줄여 이 전보다 효율을 높일 수 있었다.

차량용 경량화 침입 탐지 시스템을 위한 데이터 전처리 기법 (Data Preprocessing Method for Lightweight Automotive Intrusion Detection System)

  • 박상민;임형철;이성수
    • 전기전자학회논문지
    • /
    • 제27권4호
    • /
    • pp.531-536
    • /
    • 2023
  • 본 논문에서는 차량 내 네트워크에서 즉각적인 공격 탐지를 위해 프레임 피처 삽입이 적용된 슬라이딩 윈도우 기법을 제안한다. 이 방법은 현재 프레임의 공격 여부에 따라 라벨링을 진행하기 때문에 공격 탐지의 실시간성을 보장할 수 있다. 또한 이 방법이 CNN 연산에서 현재 프레임에 대한 가중치를 주어 성능을 향상시킬 수 있음을 실험을 통해 확인하였다. 제안하는 모델은 경량화된 LeNet-5 구조 기반으로 설계되었으며 DoS 공격 탐지 성능에서 100%를 달성하였다. 또한 기존 연구의 모델들과 복잡성을 비교했을 때 제안하는 모델이 ECU와 같이 리소스가 제한된 장치에 더 적합함을 확인하였다.

수정된 Sinc 보간법을 이용한 새로운 Rayleigh 페이딩 보상 알고리즘 (An Improved Rayleigh Fading Compensation Algorithm with Modified Sinc Interpolation)

  • 이창재
    • 한국통신학회논문지
    • /
    • 제25권10A호
    • /
    • pp.1492-1498
    • /
    • 2000
  • Sine 보간법을 이용한 PSAM은 Cavers의 최적 Wiener 필터를 사용한 알고리즘보다 구현은 간단하면서 채널추정 성능은 거의 동일하다. 그러나 이 알고리즘은 window 함수와 같이 사용해야만 우수한 채널추정 성능을 갖는다. 본 논문에서는 이러한 기존의 sine 보간법 (conventional sine interpolation : CSI) 의 단점을 보완한 수정된 sine 보간법 (modified sine interpolation : MSI) 을 제안한다. MSI 알고리즘의 성능평가를 위해 다중반송파 QAM 시스템과 주파수 선택성 페이딩을 고려한 최적 프레엄구조를 사용하였다. 성능평가에서 window 함수를 사용하지 않은 MSI 알고리즘은 더 적은 수의 파일럿 심볼을 사용하면서도, window 함수를 사용한 CSI 알고리즘과 거의 동일한 BER 성능을 보였다. 아울러, window 함수를 사용한 MSI 알고리즘의 성능은 PSAM을 적용한 이론적인 16QAM의 성능과 거의 일치하였다.

  • PDF

터보 복호를 위한 슬라이딩 윈도우 방식을 적용한 MAP 구조에 관한 연구 (A Study of MAP Architecture Adopting the Sliding Window Method for Turbo Decoding)

  • 최광석
    • 한국통신학회논문지
    • /
    • 제32권5A호
    • /
    • pp.426-432
    • /
    • 2007
  • 터보 복호를 위한 MAP(Maximum A Posteriori) 알고리즘을 슬라이딩 윈도우 방식으로 설계하고 구현하였다. 먼저, 구현하는데 필요한 논쟁점들 즉, 슬라이딩 윈도우의 길이 및 상태 메트릭의 정규화 방식 등이 논의되고 그들의 최적 값을 모의실험을 통하여 얻었다. 또, 가지 메트릭 계산기를 포함한 복호기의 모든 구성요소의 회로가 제출되었다. 제안된 MAP구조는 버퍼 제어를 간단히 하여 슬라이딩 윈도우 크기 즉, 부-프레임 길이의 변경에 따라 쉽게 재설계 될 수 있다.

창호 구성 요소에 따른 난방에너지 절감율 예측에 관한 연구-공동주택을 중심으로 (Prediction of Heating Energy Saving Rate on the Window Type-Focus on the Apartment House)

  • 김경아;문현준;유기형
    • 한국태양에너지학회 논문집
    • /
    • 제33권6호
    • /
    • pp.54-61
    • /
    • 2013
  • This is study on the glazing performance of the apartment house to predict energy saving rate when the early design stage by calculating heating load. there are various factors of the window type in apartment building to save energy such as window's U-value, SC or SHGC, window wall ration, frame factor, sunshade coefficient and so on. In this study, we analyzed the heating load focused on the U-value, SC and window wall ration using variable heating degree days method for a small and middle size units $59m^2$, $84m^2$, respectively. Each cases were calculated heating load of the real models compared to standard model to predict energy saving rate. From those cases it was drew the conclusion that were window's U-value, SC and window wall ration for the small and middle size units to expect 10% energy saving rate at least.

자연환기장치가 적용된 공동주택의 기밀 및 공기유동 성능 실측 연구 (A Study of Measurement on Airtightness and Air-Flow Performance of Apartment Housing Adopting Window Frame-Type Natural Ventilation)

  • 전주영;김길태;김선동
    • 토지주택연구
    • /
    • 제5권4호
    • /
    • pp.325-332
    • /
    • 2014
  • 본 연구에서는 창문형 자연환기장치가 설치된 7개 세대의 소형공동주택($33m^2{\sim}51m^2$)을 대상으로 Blower Door를 이용한 현장 기밀성능 및 공기유동 성능을 측정하였다. 창문형 자연환기장치는 외기에 면하는 모든 창호 및 거실분합문에 설치되어 있으며, 수동 개폐형 장치가 설치되어있다. 본 연구에서는 자연환기장치와 창호의 개폐여부에 따라서 6개의 CASE를 설정하여 실측하였다. 측정결과, 자연환기장치와 모든 개구부를 밀폐한 상태의 기밀성능 값(CASE1)은 1.77~3.12ACH로 평균 2.27ACH로 나타났으며, 문헌조사 결과 자연환기장치가 설치되지 않은 일반 공동주택(1.65~4.28ACH)과 유사하게 나타났다. 내외측의 자연환기장치를 모두 열었을 때의 공기유동성능 값(CASE6)은 평균 5.87ACH로 나타나 밀폐조건과 비교하여 평균 3.6ACH가 증가하는 것으로 나타났다. 외측 환기장치와 창호를 밀폐한 조건에서 내측 환기장치만 개방시와 내측창을 개방시의 공기유동성능값의 차이는 평균 0.29ACH로 내측창호 개방시의 기밀성능 값이 높게 나타났다. 반대로 내측 환기장치와 창호를 밀폐한 조건에서 외측 환기장치만 개방시와 외측창 개방시의 차이는 평균 0.30ACH로 외측창호 개방시가 높게 나타났다. 내측창호만의 공기유동성능과 외측창호만의 공기유동성능 측정값의 차이는 0.77ACH로 내측창호가 더 우수하게 나타났다. 향후에는 자연환기장치와 창호 및 새시의 종류에 따른 기밀성능의 추가 측정을 통해 정량적 상관관계 조사가 필요할 것으로 판단된다.

한지창호의 실내 온.습도 조절효과에 관한 실험적 연구 (An Experimental Study on the Effect of Hanji Windows on Indoor Air Temperature and Humidity Control)

  • 장길수;박사근;송민정;신훈
    • 한국주거학회논문집
    • /
    • 제17권2호
    • /
    • pp.125-134
    • /
    • 2006
  • The tightness of windows have devoted to the improvement of thermal insulation and energy saving in buildings. But it is known that this tightness causes some side effects such as low ventilation, low capacity to humidity and temperature control and these are not profitable for inhabitants. To act on these side effects, Korean traditional windows which are composed of Han-Ji(Koreand traditional paper) and Chang-Sal(Korean traditional wooden frame) have been studied to get a reasonable solutions for these problems. In this study, to compare the thermal and humidity control performance of current window(12 mm pair) and Korean traditional windows, frames which are made of existing window and Korean traditional windows are adapted to scale model house and then humidity and temperature of in and out of scale model house are measured and analysed. The results of this study are followings ; 1) When Korean traditional window charges 20cm(1/8 of total window area) from total window area, Han-Ji window has higher thermal insulation than that of existing window in daytime. There is the most big thermal difference when double faced with double-ply Han-Ji window is placed to mock-up house. In night-time, the temperature difference is very small so this means that Korean traditional window is good to cover direct sunlight in daytime and reduce the temperature of balcony. One faced with one-ply han-Ji window has the best humidity penetration performance among three type of Korean traditional windows. 2) When Korean window area enlarged to 40cm(1/4 of total window area), the function of 40cm width Han-Ji window is higher than that of 20cm's. This means that enlargement of Han-Ji window cover direct sunlight more and is more efficient in humidity penetration.

창호의 성능인증 규격 기준과 면적 변화에 따른 에너지성능 비교분석 (A Comparative Analysys of Window Energy Performance According to the Difference Between Actual size and Standard size)

  • 김성범;이수열;김동윤;최원기
    • 한국태양에너지학회 논문집
    • /
    • 제40권1호
    • /
    • pp.49-60
    • /
    • 2020
  • This study reviewed selected specific windows and reviewed the window performance certification criteria including KS F 2278 and KS L 9107 and analyzed the change in performance based on the change of area. This study also compared the heating and cooling loads of an apartment house applied with window performance reviewed in consideration of insulation and SHGC performance and actual size based on KS F 2278. The analyzed window was a double window composed of aluminum and PVC and the building was the apartment house model of 141 ㎡. The analysis results were as follows. First, as the window glass's thermal performance is superior to frame, the performance degraded in reduced area. In case of selected window, the 1 m × 1m window's thermal performance and SHGC decreased by 35% and 37% respectively compared to 2 m × 2 m window. Secondly, in the comparison of performance for increasing area with 2 m × 2 m and 3 m × 3 m windows, the 3 m × 3 m window's thermal performance and SHCG increased about 14%. Third, in the comparison of heating and cooling loads of the analyzed model considering the apartment house model applied with window performance derived from KS F 2278 and actual figures, the model's total heating and cooling loads increased by 33% with cooling decreasing by 36% and heating increasing by 77%. Above analysis results show that evaluation of window performance based on criteria such as KS F 2278 and KS L 9107 may lead to distortion of performances different from actual products. Thus, it is necessary to suggest new evaluation criteria.

전통건축 대청 배면 개구부형식의 변천에 관한 연구 (A study on the transition of the type of openings constructed at backside of DAECHUNG in Korean traditional architectures)

  • 정명섭
    • 한국주거학회논문집
    • /
    • 제5권2호
    • /
    • pp.29-40
    • /
    • 1994
  • The purpose of this study is to survey the transition of the type of openings in korean traditional archiectures. To do this, various types of openings at the backside of Daechung of 23 Hyang-Gyo Myung-Ryun-Dangs were investigated. After the classification in some groups according to their types and their periods of constuction, the tasnsition of the type of openings was analysed. Results are as follows. (1) The openings constructed form 16th to 17th century, the earliest form, is a ledged and battened panel window(or framed and ledged panel window) whose mullion is built on the frame of window. It is presumed that these types were widely used before 17th century. (2) The next type is ledged and battened panel window(door) (or framed and ledged panel window) which lacks a mullion. These types were thought to be customed after 18th century. (3) The lastest type, which is appeared from 19th to 20th century, is an characteristic backside opening(ledged and battened panel window or framed and ledged panel window) that among 3 column spacings the central one is enlarged in comparison with the right and left ones. Through this transition pattern of the openings, can be menifested that the trend of 20th century is to enlarge convenience of usage by constuctiong door and eliminating some windows.

  • PDF