• Title/Summary/Keyword: Winding temperature

검색결과 259건 처리시간 0.03초

더블팬케이크 권선형 10kVA 고온초전도 변압기 (10kVA high $T_c$ Superconducting Power Transformer with Double Pancake Windings)

  • 이희준;차귀수;이지광;한송엽;류경우;최경당
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제50권2호
    • /
    • pp.65-72
    • /
    • 2001
  • This paper presents the design and test results of a 10kVA single phase HTS transformer which is operating at 77K. Double pancake windings with BSCCO -2223 HTS tape and GFRP cryostat with room temperature bore are used in the transformer. Four double pan cake windings were used in pancake windings are connected in parallel to conduct the secondary current of 45.4A. the rated voltages of each winding are 440/220V. Numerical calculation using Finite Element Method was used to evaluated the performance of each arrangement. Considering the magnetizing reactance, leakage reactance, electrical insulation and the circulating current in low voltage winding which had two windings in parallel, HLLH arrangement was finally chosen. Estimation of the AC loss, magnetizing loss and self field loss, in the design stage, where effects of perpendicular field and parallel field are considered. Room temperature bore type cryostat has been constructed and its heat loss was measured.

  • PDF

식물성 절연유 변압기의 냉각특성 변화에 따른 최고점온도 특성 해석 (Characteristic Analysis of Hot Spot Temperature according to Cooling Performance Variation of Natural Ester Transformer)

  • 김지호;이향범
    • 전기학회논문지P
    • /
    • 제64권4호
    • /
    • pp.236-240
    • /
    • 2015
  • Natural ester has a higher biodegradability, flash and fire points, and a greater permittivity compared to conventional mineral oils. However, natural ester also has a higher pour point, viscosity, and water content. These characteristics hamper circulation and the electrical properties of oil-filled transformer. Thus, this paper applied electromagnetic-thermal-flow coupled analysis method to predict temperature distribution inside 154kV single phase power transformer using natural ester. It modeled in the actual appearance for the tank and winding of the power transformer to improve the accuracy of analysis and applied heat flow analysis that considered hydromechanics and heat transfer at the same time. It calculated the power loss, the main cause of temperature rise, from winding and core with electromagnetic analysis then used for the heat source for the heat flow analysis. It then compared the reasonability of result of measurement analysis based on the result acquired from temperature rise test using FBG sensor on the power transformer.

18kV 배전용 피뢰기의 구조에 따른 온도특성 (Temperature Characteristics with Structure of 18kV Lightning Arresters for Distribution System)

  • 조한구;윤한수;이운용;김석수;최인혁
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.2
    • /
    • pp.1125-1128
    • /
    • 2004
  • This paper presents the temperature characteristics with structure of 18 kV lightning arresters for distribution. Three types of polymer arresters were fabricated and ceramic type arrester was also ready to investigate. Below $100^{\circ}C$, three types of polymer arresters exhibited almost the same leakage current value, but above $100^{\circ}C$, polymer arrester that arrester module was injected into polymer housing with grease exhibited the highest leakage current and the arrester with the lowest leakage current was the arrester that silicon rubber was directly injected to arrester module. The rising of leakage current of polymer arrester with grease was because of existing grease between FRP winding and silicon housing, and reducing the insulation characteristics of the grease. All polymer arresters exhibited the same temperature characteristics but ceramic typr arrester was slower than polymer arrester in heat emission despite lowest leakage current. It was thought that the air layer between ZnO varistor blocks and ceramic housing prevented the heat emission. However, in spite of the difference of the structure, the variation of the surface temperature of all arresters exhibited the same result.

  • PDF

100kVA 주상용 몰드 변압기의 온도분포 해석 (The Temperature Distribution Analysis of Mold transformer)

  • 조한구;이운용
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 춘계학술대회 논문집 방전 플라즈마 유기절연재료 초전도 자성체연구회
    • /
    • pp.125-129
    • /
    • 2004
  • The mold transformers have been widely used in underground substations in large building and have some advantages in comparison to oil-transformer, that is low fire risk, excellent environmental compatibility, compact size and high reliability. In addition, the application of mold transformer for outdoor is possible due to development of epoxy resin. The mold transformer generally has cooling duct between low voltage coil and high voltage coil. A mold transformer made by one body molding method has been developed for small size and low loss, but it needs some cooling method because heat radiation between each winding is difficult. The life of transformer is significantly dependent on the thermal behavior in windings. Many transformer designers have calculated temperature distribution and hot spot point by FEM(finite element method) to analyze winding temperature rise. In this paper, the temperature distribution and thermal stress analysis of 100kVA pole cast resin transformer for power distribution are investigated by FEM program.

  • PDF

권선장력을 고려한 초전도 계자코일의 퀀치특성 및 AE 신호특성에 관한 연구 (A study on Quench Characteristics considering Winding Tension in Superconducting Coil using Acoustic Emission Technique)

  • 이준현;이민래;손명환;권영길
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제1권2호
    • /
    • pp.8-14
    • /
    • 1999
  • In this study, acoustic emission(AE) technique has been applied to detecting quench which is one of the serious peoblems to assure the integrity of superconducting coil at cryogenic temperature. The characteristics of AE parameters have been analyzed by correlating with the number of quenches, whinding tension of superconducting coil and charge rate of transport current. The quench localization was also performed using AE signals and there was also good correlation between quench current and AE parameters such as AE energy and AE events. In this study, it was confirmed that AE signals were mainly due to the conductor motion which caused by premature quenching. It was also found that optimized winding tension at superconducting coil was needed to prevent quench caused by conductor motion.

  • PDF

Manufacture and Test of Small-scale Superconducting Fault Current Limiter by Using the Bifilar Winding of Coated Conductor

  • Yang, Seong-Eun;Ahn, Min-Cheol;Park, Dong-Keun;Jang, Dae-Hee;Ko, Tae-Kuk
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제7권4호
    • /
    • pp.20-23
    • /
    • 2005
  • The Resistive Type High Temperature Superconducting Fault Current Limiter (SFCL) has been developed in many countries. Until now, materials of the resistive SFCL were Bi2212 bulk and YBCO thin film. Although YBCO coated conductor (CC) has many advantages such as high n-value and critical current for applying resistive SFCL, the resistive SFCL using CC doesn't have developed yet. The bifilar winding type SFCL was manufactured and tested rated on 30V/80A. In normal state, the SFCL using pancake type bifilar winding had very low impedance. When a fault occurred, the SFCL limited the fault current efficiently. Through these results of experiment, large-scale SFCL using CC should be developed in the future.

회전 기기의 수명 예측 평가에 관한 연구 (A Study on the Expected Life Evaluation of Rotating Machine)

  • 김기준;김상진;오용철;성낙진
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 제2회 학술대회 논문집 일렉트렛트 및 응용기술전문연구회
    • /
    • pp.73-76
    • /
    • 2000
  • Traction motors that is one of the rotating machines for urban transit EMU have been subjected to increased demand for higher operating temperature, more demanding duty cycles, higher starting current, frequent voltage transients and severe environmental exposure. With the advent of PWM drives using power IGBTs in addition to the thermal considerations, it is important to take into account the impact of the dielectric stress upon the winding insulation system life. In analyzing the life of the stator winding, which is the heart of the motor, the majority of all winding failures are usually caused by a combination of various stresses acting on the insulation materials and system. In this paper, to evaluate the expected life of traction motor for urban transit E.M.U. it is proposed a new test method of complex accelerating degradation.

  • PDF

$SF_6$ EHV VT 권선 절연지의 절연특성 (Insulation Characteristics of PET Films for $SF_6$ EHV VT Winding)

  • 김정달;박재윤;정장근;김종석;하현진;이용길
    • 한국전기전자재료학회논문지
    • /
    • 제14권5호
    • /
    • pp.391-396
    • /
    • 2001
  • The purpose of this study is to investigate the effect of hole or crack on the Insulation characteristics of a PET films for EHV(Extra High Voltage) VT winding. The hole or the crack in the PET films was made and the insulation characteristics of them were measured. Ad an experimental result, it was shown hat he PDIV(Partial Discharge Inception Voltage) and the BDV(Breakdown Voltage) of the PET films with hole or crack were lower than those without them, and were markedly dependent on their position and temperature. Therefore, the hole and the crack affected to insulation characteristics of PET films for SF$_{6}$EHV(Extra High Voltage) VT Winding.g.

  • PDF

변압기 권선진동의 모형화 연구 (A study on the modelling of power transformer winding vibration)

  • 이성호;강창구;김재철;정찬수;곽희로;주병수;윤진열;정상진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 A
    • /
    • pp.216-218
    • /
    • 1994
  • This paper established on vibration model of transformer winding caused, mainly, by load current. We considered the rotations between loads and vibration amplitudes by changing load current in constant temperature and voltage, to get the modeling of transformer winding vibration. Equation between loads and vibration signal's amplitudes using LS approximation mode it possible to predict a vibration signal's amplitude at any load. With this equation, we arc willing to establish the basis data for power transformer diagnosis.

  • PDF

진동신호 분석을 이용한 변압기 고장판별법 연구 (Fault determination of power transformer by using analysis of vibration signal)

  • 박수문;정찬수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 B
    • /
    • pp.1152-1154
    • /
    • 1996
  • In power transformers, vibration occurs at winding, core and case due to current, voltage, temperature changing and winding reformation. Winding deformation and change of vibration signals are occurred due to electromagnetic force induced by fault current. In this paper, in normal and fault states, the trends of fundamental waves and higher harmonics are considered. To inspect the factors that affect the fundamental waves and higher harmonics, the trends are considered with varying voltage and load. Determination functions are generated and applied to signals so that normal and fault state are determined by determination functions.

  • PDF