• 제목/요약/키워드: Winding direction

검색결과 90건 처리시간 0.03초

Current limiting characteristics of transformer type SFCL with coupled secondary windings according to its winding direction

  • Han, Tae Hee;Lim, Sung Hun
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제19권2호
    • /
    • pp.44-47
    • /
    • 2017
  • In this paper, the current limiting characteristics of the transformer type superconducting fault current limiter (SFCL) with the two coupled secondary windings due to its winding direction were analyzed. To analyze the dependence of transient fault current limiting characteristics on the winding direction of the additional secondary winding, the fault current limiting tests of the SFCL with an additional secondary winding, wound as subtractive polarity winding and additive polarity winding, were carried out. The time interval of quench occurrence between two superconducting elements comprising the transformer type SFCL with the additional secondary winding was confirmed to be affected by the winding direction of the additional secondary winding. In case of the subtractive polarity winding of the additional secondary winding, the time interval of the quench occurrence in two superconducting elements was shorter than the case of the additive polarity winding.

Transient Fault Current Limiting Characteristics of a Transformer Type SFCL Using an Additional Magnetically Coupled Circuit

  • Lim, Seung-Taek;Lim, Sung-Hun
    • Transactions on Electrical and Electronic Materials
    • /
    • 제18권1호
    • /
    • pp.42-45
    • /
    • 2017
  • In this paper, a transformer type SFCL (superconducting fault current limiter) using an additional magnetically coupled circuit was suggested. Its transient fault current limiting characteristics, due to the winding direction of additional coupled circuit, were analyzed through fault current limiting tests. The suggested transformer type SFCL was composed of the primary winding, and one secondary winding wound on the same iron core together with an additional magnetically coupled circuit. That circuit consists of the other secondary winding together with the other SC (superconducting) element connected in parallel with its other secondary winding. As one of the effective design parameters to affect the transient fault current of the SFCL, the fault current limiting tests of the suggested SFCL were carried out considering the winding direction of its additional coupled circuit. It was confirmed that, through the analysis on the fault current tests of the SFCL, the quench sequence of two SC elements comprising the suggested SFCL could be adjusted by the winding direction of the additional coupled circuit.

결선방향에 따른 자속구속형 전류제한기의 퀜치 회복 의존도 해석 (Analysis on Quench Recovery Dependence of A Flux-Lock Type SFCL According to the Winding Directions)

  • 정수복;조용선;최명호;최효상
    • 조명전기설비학회논문지
    • /
    • 제22권1호
    • /
    • pp.113-117
    • /
    • 2008
  • 본 논문에서는 결선방향에 따른 자속구속형 전류제한기의 전류제한 및 회 특성에 대해 분석하였다. 자속구속형 초전도 한류기는 초전도 소자와 직렬로 연결된 2차 권선과 병렬로 연결된 1 2차 권선으로 구성되어 있다. 1 2차 권선의 결선방향에 따른 가극 결선과 가극 결선을 갖는 자속구속형 전류제한기를 저항형 전류제한기와 비교하여 분석하였다. 전류제한 및 회복특성은 1 2차 권선의 결선방향에 의존한다. 가극 결선을 갖는 자속구속형 전류제한기의 퀜치시간은 감극 결선이나 저항형 전류제한기보다 더 빠르다는 것을 확인하였다. 초전도 소자에서 소비되는 에너지는 $W= VIt=I^2Rt$으로 표현할 수 있다. 결선 방향에 따라 초전도 소자에서 소비되는 에너지의 차이는 초전도 소자에서 부담하는 전압의 차이 때문이라는 것을 확인할 수 있었다.

Convex형 권선배치방식을 취한 권철심변압기의 충격파절연설계에 관한 연구 (Study on Insulation Design of Surge Voltages for Convex Winding type Ribbon Core Transformer)

  • 황영문;조철제;김중한
    • 전기의세계
    • /
    • 제22권3호
    • /
    • pp.13-24
    • /
    • 1973
  • In this report, as a method to solve the problems on impulse insulation coordination in ribbon core transformer owing to it's BIL stepping up, new design to alter winding distribution of multiple-layer concentric winding to Convex type winding is proposed. The main focus of this method is to settle the weakness of axial direction insulation strength and as a result of theoretical analysis through experiment of model transformers, the following conclusions are obtained; (a) As the electric loadings in a design which increases by strengthenning axial direction insulation endurance in presently avarilable transformers owing to it's BIL stepping up can be restricted in Convex type winding, reasonable design will be suited to the transformer with higher BIL. (b) Convex type winding is a very improved insulation design in respect of insulation coordination because it has shield plate effect to even impulse oscillation. (c) There is a disadvantage to cause leakage flux to increase in Convex type winding, however, the constancy of electric loadings in a design in spite of BIL stepping up restricts the increase of leakage flux to some extent.

  • PDF

자속구속형 고온초전도 사고전류 제한기의 사고제거 후 회복특성 (Recovery Characteristics of a Flux-lock Type HTSC Fault Current Limiter after Fault Removal)

  • 임성훈
    • 한국전기전자재료학회논문지
    • /
    • 제20권9호
    • /
    • pp.812-815
    • /
    • 2007
  • To apply the superconducting fault current limiter(SFCL) into a power system, the analysis for its recovery characteristics as well as the consideration for its cooperation with other protecting machine such as a circuit breaker is required. The recovery characteristics of the flux-lock type SFCL like its current limiting characteristics are dependent on the winding direction of two coils. In this paper, the experiments of the current limiting and the recovery characteristics of the flux-lock type SFCL with YBCO thin film were performed. From the analysis on the experimental results due to the winding direction of two coils, the limited fault current in case of the additive polarity winding was observed to be lower than that for the case of the subtractive polarity winding. In addition, the recovery time was found to be faster in case of the additive polarity winding compared to the subtractive polarity winding.

삼상 분리형 자속커플링 전류제한기의 2차 권선의 턴 수 및 결선 방향에 따른 전류제한 특성 (Current Limiting Characteristics of Separated Three-phase Flux-coupling Type SFCL according to Winding Number of Coil 2 and Winding Direction)

  • 김용진;두호익;두승규;김민주;이동혁;한병성
    • 한국전기전자재료학회논문지
    • /
    • 제22권8호
    • /
    • pp.694-697
    • /
    • 2009
  • The separated three-phase flux-coupling type superconducting fault current limiter(SFCL) is composed of a series transformer and superconducting unit of the YBCO coated conductor. The primary and secondary coils in the transformer were wound in series each other through an iron core and the YBCO coated conductor was connected with secondary coil in parallel. In this paper, we investigated the current limiting characteristics through winding number of coil 2 and winding direction in the flux-coupling type SFCL. Through the analysis, it was shown that additive polarity condition and lower winding number of coil 2 have advantaged from the point of view of fault current limiting and burned of YBCO coated conductor.

연방향 영향을 고려한 2층 고온초전도 전력케이블 코어 설계 (Design of a 2-Layer HTS Power Transmission Cable Core According to the effect of Winding Direction)

  • 주진홍;김석환;조전욱;배준한;김해종;김해준;성기철;홍정표
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 학술대회 논문집
    • /
    • pp.58-61
    • /
    • 2003
  • A typical HTS power transmission cable has multi-layer conductor structure to increase the current capacity. The current distribution among the conductor tapes is controlled mainly by pitches and winding directions of the layers, because the inductance of the layer is determined by the pitch and the winding direction. However, usually the current is not evenly distributed among the layers. This paper describes a method to make the current distribution more uniform and hence reduce the AC loss. If we choose a good combination we can find the optimal pitches and make an even current distribution. We studied the effect of the winding direction on a 2-layer cable by a statistical way. Calculation results and discussions will be presented.

  • PDF

병렬연결된 두 코일의 자기결합을 이용한 초전도 전류제한기의 전류제한 및 전압강하 보상 특성 분석 (Analysis on Current Limiting and Voltage Sag Compensating Characteristics of a SFCL using Magnetic Coupling of Parallel Connected Two Coils)

  • 임성훈
    • 한국전기전자재료학회논문지
    • /
    • 제23권2호
    • /
    • pp.159-163
    • /
    • 2010
  • The superconducting fault current limiter (SFCL) plays a role in compensating the voltage sag of the sound feeder adjacent to the fault feeder as well as the fault current limiting operation of the fault feeder. Especially, the SFCL using magnetic coupling of two coils with parallel connection has different voltage sag compensating and current limiting characteristics due to the winding direction and the inductance ratio of two coils. In this paper, the current limiting and the voltage sag compensating characteristics of a SFCL using magnetic coupling of parallel connected two coils were analyzed. Through the analysis on the experimental results considering the winding direction of two coils, the SFCL designed with the additive polarity winding was shown to have the higher limited fault current than the SFCL designed with the subtractive polarity winding. In addition, it could be confirmed that the higher fault current limitation of the SFCL could be contributed to the higher load voltage sag compensation.

변압기 권선을 이용한 자속구속형 초전도 전류제한기의 전류제한 및 전압강하 보상 특성 (Current Limiting and Voltage Sag Compensation Characteristics of Flux-Lock Type SFCL Using a Transformer Winding)

  • 고석철
    • 한국전기전자재료학회논문지
    • /
    • 제25권12호
    • /
    • pp.1000-1003
    • /
    • 2012
  • The superconducting fault current limiter (SFCL) can quickly limit the fault current shortly after the short circuit occurs and recover the superconducting state after the fault removes and plays a role in compensating the voltage sag of the sound feeder adjacent to the fault feeder as well as the fault current limiting operation of the fault feeder. Especially, the flux-lock type SFCL with an isolated transformer, which consists of two parallel connected coils on an iron core and the isolated transformer connected in series with one of two coils, has different voltage sag compensating and current limiting characteristics due to the winding direction and the inductance ratio of two coils. The current limiting and the voltage sag compensating characteristics of a SFCL using a transformer winding were analyzed. Through the analysis on the short-circuit tests results considering the winding direction of two coils, the SFCL designed with the additive polarity winding has shown the higher limited fault current than the SFCL designed with the subtractive polarity winding. It could be confirmed that the higher fault current limitation of the SFCL could be contributed to the higher load voltage sag compensation.