• Title/Summary/Keyword: Wind turbine system

Search Result 994, Processing Time 0.04 seconds

국내 풍력발전시스템 인증제도 개선방안에 관한 연구 (A Study on the Improvement of Domestic Wind Turbine Certification System)

  • 장호진;박정하;박영현;박진철
    • 한국태양에너지학회 논문집
    • /
    • 제31권6호
    • /
    • pp.125-131
    • /
    • 2011
  • Recently, the application of renewable energy to building is steadily increasing in domestic due to the energy saving efforts around the world. Among the all, wind energy is one of the rising energy source because of its high technological maturity. Domestic wind power market has rapidly increased in recent years but the certification system for wind turbine has not been activated since it was introduced in 2009. Thus, this study aims to propose the improvement of certification system for wind turbine by comparing domestic certification system with international certification system. The result of this study are as follows. First, domestic certification system needs to be subdivided and established by systematic standards. Second, it is considered that education about rating standards is required to wind turbine makers to activate domestic certification system. Third, domestic certification agenciesand test agencies need to be unified and reduced.

Flicker Suppression Scheme for Variable-Speed Wind Turbine Systems

  • Van, Tan Luong;Nguyen, Thanh Hai;Lee, Dong-Choon
    • Journal of Power Electronics
    • /
    • 제12권2호
    • /
    • pp.333-343
    • /
    • 2012
  • This paper proposes a strategy of flicker mitigation for doubly-fed induction generator (DFIG) wind turbine systems. In the weak grid system where the grid impedance ratio is low, the reactive power compensation only cannot suppress the flicker sufficiently due to the limited power capacity of the converters or the DFIG. For the full suppression of flickers, the active power smoothening using the energy storage system (ESS) needs to be utilized together with the reactive power compensation. The effectiveness of the proposed method is verified by PSCAD/EMTDC simulation results for a 2[MW] DFIG wind turbine system and by experimental results for a 3[kW] wind turbine simulator.

3MW 풍력발전시스템 출력성능평가에 관한 연구 (The Power Performance Testing for 3MW Wind turbine System)

  • 고석환;장문석;박종포;이윤섭
    • 한국태양에너지학회 논문집
    • /
    • 제31권4호
    • /
    • pp.19-26
    • /
    • 2011
  • We are carried out power performance testing for 3MW wind turbine system at Je-ju wind turbine testing Site and analyzed measured data which was stored through monitoring system. In this paper, we described the power performance testing results and analyzed an uncertainty of measured data sets. The power curve with measured power data is closely coincide with designed power curve except for the low wind speed sections(4m/s~7m/s) and the annual energy production which is given Ray leigh distribution was included with 1.5~5.9% of uncertainty in the wind speed region as 4~11m/s. Although the deviation of curve between measured power and designed power is high, the difference of annual energy production is low in the low wind speed region.

PSCAD/EMTDC를 이용한 고정속 풍력발전시스템 모델링 및 과도상태 안정화기법 (Fixed speed wind power generation system modeling and transient state stabilization method using PSCAD/EMTDC)

  • 김영주;박대진;;박민원;유인근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.1178-1179
    • /
    • 2008
  • This paper describes a modeling of fixed speed wind power generation system which comprise of wind turbine, generator and grid. The wind turbine is based on MOD-2, which is IEEE standard wind turbine, and includes a component using wind turbine characteristic equation. Fixed speed induction generator is directly connected to grid, so the variation of wind speed has effects on the electrical torque and electrical output power. Therefore the power control mode pitch control system is necessary for aerodynamic control of the blades. But the power control mode does not operate at the fault condition. So it is required some methods to control the rotor speed at transient state for stabilization of wind power system. In this paper, simulation model of a fixed speed wind power generation system based on the PSCAD/EMTDC is presented and implemented under the real weather conditions. Also, a new pitch control system is proposed to stabilize the wind power system at the fault condition. The validity of the stabilization method is demonstrated with the results produced through sets of simulation.

  • PDF

소형 풍력의 과풍속 보호 장치에 관한 연구 (A study of overspeed-protection furling mechanism of Small Wind Turbine)

  • 김형길;김철호;서영택;오철수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.959-960
    • /
    • 2007
  • The wind power has been used steadily since long ago, but the importance of it has been faded because of the abundant and convenient fossil energy. Now, due to the energy crisis, experiencing the environmental problems etc, the necessity of using it growing bigger. Because the small wind turbines under a few kW grade has the merits of setting up with low costs by individuals, and get the energy saving effects that, it has the secured, separate markets from the range systems, and the developing of it is continuously proceeding. The small wind turbine system must have the output power regulating system for the over wind speed, to run steadily in the various wind speed environment. In case of the small wind turbine system, to prevent the breaking and for safety, at the over wind speed, additional system is required, and in most cases, output power is restricted by mechanical means. In this paper, the furling system makes the tail and the head move to make the blades to the wind in slanted angle, restrict the output power at the over wind speed. In thesis, small prototype wind turbine is made, and analyzing the output power characteristics at the over wind speed, and to verify, through the logical study and tests.

  • PDF

100 kW급 풍력발전기의 하중 측정 (Load Measurements of 100 kW Wind Turbine)

  • 배재성;김성완;경남호
    • 한국태양에너지학회 논문집
    • /
    • 제24권4호
    • /
    • pp.27-33
    • /
    • 2004
  • Mechanical load measurements on blade and tower of Vestas 100 kW wind turbine has been reformed in Wollyong test site, Jeju island. The experimental procedure for the measurement of wind turbine loads, such as edgewise(lead-lag) bending moment, flapwise bending moment, and tower base bending moment, has been established. The test facilities consisting of strain-gauges, telemetry and T-Mon system are installed in the wind turbine. Strain gauges are on-site calibrated against load cell prior to monitoring the wind turbine loads. Using the test setup, the loads on the components are being measured and analysed for various external conditions of the wind turbine. A set of results for near rated wind speed has been presented in this paper.

Simultaneous out-of-plane and in-plane vibration mitigations of offshore monopile wind turbines by tuned mass dampers

  • Zuo, Haoran;Bi, Kaiming;Hao, Hong
    • Smart Structures and Systems
    • /
    • 제26권4호
    • /
    • pp.435-449
    • /
    • 2020
  • To effectively extract the vast wind resource, offshore wind turbines are designed with large rotor and slender tower, which makes them vulnerable to external vibration sources such as wind and wave loads. Substantial research efforts have been devoted to mitigate the unwanted vibrations of offshore wind turbines to ensure their serviceability and safety in the normal working condition. However, most previous studies investigated the vibration control of wind turbines in one direction only, i.e., either the out-of-plane or in-plane direction. In reality, wind turbines inevitably vibrate in both directions when they are subjected to the external excitations. The studies on both the in-plane and out-of-plane vibration control of wind turbines are, however, scarce. In the present study, the NREL 5 MW wind turbine is taken as an example, a detailed three-dimensional (3D) Finite Element (FE) model of the wind turbine is developed in ABAQUS. To simultaneously control the in-plane and out-of-plane vibrations induced by the combined wind and wave loads, another carefully designed (i.e., tuned) spring and dashpot are added to the perpendicular direction of each Tuned Mass Damper (TMD) system that is used to control the vibrations of the tower and blades in one particular direction. With this simple modification, a bi-directional TMD system is formed and the vibrations in both the out-of-plane and in-plane directions are simultaneously suppressed. To examine the control effectiveness, the responses of the wind turbine without control, with separate TMD system and the proposed bi-directional TMD system are calculated and compared. Numerical results show that the bi-directional TMD system can simultaneously control the out-of-plane and in-plane vibrations of the wind turbine without changing too much of the conventional design of the control system. The bi-directional control system therefore could be a cost-effective solution to mitigate the bi-directional vibrations of offshore wind turbines.

횡류형 터빈을 적용한 수직축 풍력발전시스템의 성능평가를 위한 실험 연구 (An Experimental Study for the Performance Analysis of a Vertical-type Wind Power Generation System with a Cross-flow Wind Turbine)

  • 조현성;정광섭;김철호
    • 한국산학기술학회논문지
    • /
    • 제15권3호
    • /
    • pp.1272-1278
    • /
    • 2014
  • 본 최근 성장하고 있는 해상 풍력의 실험연구에서 풍동시험이 수직형 횡류 풍력발전시스템의 성능을 조사하기 위해 실시되었다. 풍동의 시험 부분은 제한된 크기로 인해 실제 풍력 발전의 입구 안내 베인을 약 1/5로 축소시켰고, 터빈 임펠러의 지름을 모형 임펠러의 1/2로 감소시켰다. 임펠러 블레이드 갯수는 풍력 발전 시스템의 출력에 대한 또 다른 중요한 변수이기 때문에 8개와 16개로 변경하여 시험하였다. 실험 분석 결과, 모형 풍력 터빈의 출력 제동력은 정격 풍속 12m/s에서 블레이드 갯수가 8개 보다 16개일 때 82% 출력이 증가된 278와트로 측정되었고, 정격 제동력은 정격 작동 조건에서 3.9kW로 계산되었다.

Monitoring system for the wind-induced dynamic motion of 1/100-scale spar-type floating offshore wind turbine

  • Kim, C.M.;Cho, J.R.;Kim, S.R.;Lee, Y.S.
    • Wind and Structures
    • /
    • 제24권4호
    • /
    • pp.333-350
    • /
    • 2017
  • Differing from the fixed-type, the dynamic motion of floating-type offshore wind turbines is very sensitive to wind and wave excitations. Thus, the sensing and monitoring of its motion is important to evaluate the dynamic responses to the external excitation. In this context, a monitoring system for sensing and processing the wind-induced dynamic motion of spar-type floating offshore wind turbine is developed in this study. It is developed by integrating a 1/00 scale model of 2.5MW spar-type floating offshore wind turbine, water basin equipped with the wind generator, sensing and data acquisition systems, real-time CompactRIO controller and monitoring program. The scale model with the upper rotatable blades is installed within the basin by means of three mooring lines, and its translational and rotational motions are detected by 3-axis inclinometer and accelerometers and gyroscope. The detected motion signals are processed using a real-time controller CompactRIO to calculate the acceleration and tilting angle of nacelle and the attitude of floating platform. The developed monitoring system is demonstrated and validated by measuring and evaluating the time histories and trajectories of nacelle and platform motions for three different wind velocities and for eight different fairlead positions.

그린에너지 활용을 위한 대학건물 옥상설치형 소형풍력발전 (Small Wind Turbine Installed at the University Building Rooftop for Green Energy Utillization)

  • 이유석;김재용
    • 신재생에너지
    • /
    • 제10권3호
    • /
    • pp.14-21
    • /
    • 2014
  • As the world supply of fossil fuel sources decreases, the need for efficient energy consevation and develping green energy technologies becomes critical. Because of the high cost of the foundation for large turbines and optional high wind speed (over 12 m/s), it is very difficult to be located at inland city. For the solution above mentioned problem, we have been experimented about that not only using the adaption of wind power system on buildings for improving turbine efficiency, but also applying a wound rotor type induction generator for a small wind turbine.In this research, we try to find out the wind direction and wind speed those were measured every 1 min., during operation period, using the anemometers which consist of horizontally spinning cups on a vertical post. Performance testing for small wind turbine generating system was carried out by using the induction motor and invertor. Finally, we measured the power of 1 kW wind turbine system with the clamp meter and a voltmeter.