• Title/Summary/Keyword: Wind ratio

Search Result 984, Processing Time 0.025 seconds

On the drifting characteristics of a distressed ship (조난선박의 표류거동에 관한 연구)

  • 김창제;채양범;김길수;정태권;강성진
    • Journal of the Korean Institute of Navigation
    • /
    • v.20 no.4
    • /
    • pp.1-6
    • /
    • 1996
  • A vessel in distress might be well identified when both the variables affecting the drifting of the vessel and the extent to which the variables affect the drifted vessel are known. And also the disembarking place inside the ship might be easily located if the drifting poised is forecasted. The forecasting method of the drifting poise is resolved by combining the vectors of the current and the wind. It is, however, very hard to forecast the effect of the wind, which should be mainly determined by field survey. This study aims at identifying the drifting characteristics of medium/large ships, considering only the effect of the wind. The experiment revealed the following results. $\circled1$ The drifting poise is determined by the aspect ratio of the ship and the shape of the superstructure of the ship. $\circled2$ Drifting direction is quite stable when wind speed goes over a certain level. $\circled3$ Drifting speed is 3-7% of the wind speed in case of T/S Hannara.

  • PDF

Effect of a vertical guide plate on the wind loading of an inclined flat plate

  • Chung, Kung-Ming;Chou, Chin-Cheng;Chang, Keh-Chin;Chen, Yi-Jun
    • Wind and Structures
    • /
    • v.17 no.5
    • /
    • pp.537-552
    • /
    • 2013
  • Wind tunnel experiments were performed to study the wind loads on an inclined flat plate with and without a guide plate. Highly turbulent flow, which corresponded to free-stream turbulence intensity on the flat roof of low-rise buildings, was produced by a turbulence generation grid at the inlet of the test section. The test model could represent a typical solar collector panel of a solar water heater. There are up-stream movements of the separation bubble and side-edge vortices, more intense fluctuating pressure and a higher bending moment in the turbulent flow. A guide plate would result in higher lift coefficient, particularly with an increased projected area ratio of a guide plate to an inclined flat plate. The value of lift coefficient is considerably lower with increased free-stream turbulent intensity.

Model test and numerical simulation of OC3 spar type floating offshore wind turbine

  • Ahn, Hyeon-Jeong;Shin, Hyunkyoung
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.11 no.1
    • /
    • pp.1-10
    • /
    • 2019
  • Nowadays, the study on Floating Offshore Wind Turbines (FOWTs) is being performed globally. Dozens of numerical simulation tools have been developed for designing FOWTs and simulating their performances in combined wave and wind environments. On the other hand, model tests are still required to verify the results obtained from numerical simulation tools. To predict seakeeping performance of the OC3-Hywind platform, a OC3 spar model moored by a 3-leg catenary spread mooring system with a delta connection was built with a 1/128 scale ratio. The model tests were carried out for various sea states, including rotating rotor effect with wind in the Ocean Engineering Wide Tank, University Of Ulsan (UOU). The model test results are compared with the numerical simulations by UOU in-house code and FAST.

Application of Wind Tunnel Testing on the Dynamic Stability Derivatives of a Rocket Model (로켓 모델의 동안정미계수에 대한 풍동시험의 적용)

  • Cho, Hwan-Kee;Sung, Hong-Gye;Kim, Jin-Kon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.40 no.10
    • /
    • pp.888-893
    • /
    • 2012
  • This paper described the wind tunnel testing apparatus and technique to acquire the dynamic stability derivatives of large slenderness ratio air vehicle such as the guided missiles or rockets. There have been few difficulties in conducting wind tunnel testing for slender long rocket due to the size limitation of the test section size and the installation of oscillation equipments. In this study, the dynamic stability balance was used as the wind tunnel technique for obtaining the dynamic stability derivatives. Through the wind tunnel testing, the experimental apparatus for slender air vehicle's oscillation is established. The measured data showed that it is possible to acquire the dynamic stability derivatives of large slenderness ratio rocket, properly.

LVRT Control Strategy of Grid-connected Wind Power System (계통 연계형 풍력 발전 시스템의 LVRT 제어 전략)

  • Shin, Ho-Joon;Sul, Seung-Ki
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.2
    • /
    • pp.182-190
    • /
    • 2011
  • This paper proposes a LVRT (Low Voltage Ride Through) control strategy which should be satisfied by grid-connected wind power system when grid faults occur. The LVRT regulation indicates rules or actions which have to be executed according to the voltage dip ratio and the fault duration. Especially the wind power system has to support the grid with specified reactive current to secure the grid stability when voltage reduction ratio is over 10%. The LVRT regulation in this paper is based on the German Grid Code and full-scale variable speed wind power conversion system is considered for LVRT control strategy. The proposed LVRT control strategy satisfies not only LVRT regulation but also makes power balance between wind turbine and power system through additional DC link voltage regulation algorithms. Because it is impossible to control grid side power when the 3-phase to ground fault occurs, the DC link voltage is controlled by a generator side inverter using the DC link voltage control strategy. Through the simulation and experiment result, the proposed LVRT control strategy is evaluated and its effectiveness is verified.

Effects of Trees on Flow and Scalar Dispersion in an Urban Street Canyon (도시 협곡에서 수목이 흐름과 스칼라 물질 확산에 미치는 영향)

  • Kang, Geon;Kim, Jae-Jin
    • Atmosphere
    • /
    • v.25 no.4
    • /
    • pp.685-692
    • /
    • 2015
  • In this study, the effects of trees on flow and scalar dispersion in an urban street canyon were investigated using a computational fluid dynamics (CFD) model. For this, we implemented the drag terms of trees to the CFD model, and compared the CFD-simulated results to the wind-tunnel results. For comparison, we considered the same building configuration as the wind-tunnel experiment. The trees were located at the center of street canyon with the aspect ratio (defined as the ratio of the street width to the building height) of 1. First, the flow characteristics were analyzed in the tree-free and high-density tree cases and the results showed that the CFD model reproduced well the flow pattern of the wind-tunnel experiment and reflected the drag effect of trees in the street canyon. Then, the dispersion characteristics of scalar pollutants were investigated for the tree-free, low-density tree and medium-density tree cases. In the tree-free case, the nondimensionalized concentration distribution simulated by the CFD model was quite similar to that in the wind-tunnel experiment in magnitude and pattern. The correlation coefficients between the measured and simulated concentrations are more than 0.9 in all the cases. As the tree density increased, nondimensionalized concentration increased (decreased) near the wall of the upwind (downwind) building, which resulted from the decrease in wind speed case by the drag effect of trees. However, the CFD model underestimated (overestimated) the concentration near the wall of upwind (downwind) building.

Effect of aerodynamic modifications on the surface pressure patterns of buildings using proper orthogonal decomposition

  • Tse, K.T.;Chen, Zeng-Shun;Lee, Dong-Eun;Kim, Bubryur
    • Wind and Structures
    • /
    • v.32 no.3
    • /
    • pp.227-238
    • /
    • 2021
  • This study analyzed the pressure patterns and local pressure of tall buildings with corner modifications (recessed and chamfered corner) using wind tunnel tests and proper orthogonal decomposition (POD). POD can distinguish pressure patterns by POD mode and more dominant pressure patterns can be found according to the order of POD modes. Results show that both recessed and chamfered corners effectively reduced wind-induced responses. Additionally, unique effects were observed depending on the ratio of corner modification. Tall building models with recessed corners showed fluctuations in the approaching wind flow in the first POD mode and vortex shedding effects in the second POD mode. With large corner modification, energy distribution became small in the first POD mode, which shows that the effect of the first POD mode reduced. Among building models with chamfered corners, vortex shedding effects appeared in the first POD mode, except for the model with the highest ratio of corner modifications. The POD confirmed that both recessed and chamfered corners play a role in reducing vortex shedding effects, and the normalized power spectral density peak value of modes showing vortex shedding was smaller than that of the building model with a square section. Vortex shedding effects were observed on the front corner surfaces resulting from corner modification, as with the side surface. For buildings with recessed corners, the local pressure on corner surfaces was larger than that of side surfaces. Moreover, the average wind pressure was effectively reduced to 88.42% and 92.40% in RE1 on the windward surface and CH1 on the side surface, respectively.

High-Fidelity Ship Airwake CFD Simulation Method Using Actual Large Ship Measurement and Wind Tunnel Test Results (대형 비행갑판을 갖는 함정과 풍동시험 결과를 활용한 고신뢰도 함정 Airwake 예측)

  • Jindeog Chung;Taehwan Cho;Sunghoon Lee;Jaehoon Choi;Hakmin Lee
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.60 no.2
    • /
    • pp.135-145
    • /
    • 2023
  • Developing high-fidelity Computational Fluid Dynamics (CFD) simulation methods used to evaluate the airwake characteristics along a flight deck of a large ship, the various kind of data such as actual ship measurement and wind tunnel results are required to verify the accuracy of CFD simulation. Inflow velocity profile at the bow, local unsteady flow field data around the flight deck, and highly reliable wind tunnel data which were measured after reviewing Atmospheric Boundary Layer (ABL) simulation and Reynolds Number effects were also used to determine the key parameters such as turbulence model, time resolution and accuracy, grid resolution and type, inflow condition, domain size, simulation length, and so on in STAR CCM+. Velocity ratio and turbulent intensity difference between Full-scale CFD and actual ship measurement at the measurement points show less than 2% and 1.7% respectively. And differences in velocity ratio and turbulence intensity between wind tunnel test and small-scale CFD are both less than 2.2%. Based upon this fact, the selected parameters in CFD simulation are highly reliable for a specific wind condition.

Design for a circular arc shaped multi-blade windmill (원호형상의 멀티 블레이드를 가진 풍력터빈 설계)

  • Choo, Kwon Chul;Kim, Dong Keon;Yoon, Soon Hyun
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.390-395
    • /
    • 2004
  • The characteristics of the circular arc shaped multi-blade windmil are investigatedl. The prototypical windmill was tested in the laboratory at wind tunnel speeds of 5.5, 9.4m/s. and the model windmill was also tested in the laboratory, The power and torque coefficients were studied as functions of the blade section, the aspect ratio for blade diameter and windmill radius(M = 0.3, 0.5, 0.7), the number of blades and finally the tip-speed ratio. The analysis of the experimental results for the model windmill showed that there is the highest revolutions per minute(R.P.M) at the circular arc shaped multi-blade windmill having the blade number 10, aspect ratio(M = 0.7). and the results for the prototypical windmill showed that the power coefficient increased to a maximum value and then decreased again with an increase in the tip speed ratio, while the torque coefficient decreased directly with an increase in the tip speed ratio Finally, the experimental results were compared with the Savonius blade. the maximum power coefficient for the arc shaped blade was greater than for the Savonius blade and occured at a lower tip speed ratio.

  • PDF

Risk Assessment of Strong Wind over Industrial Facilities in Shipyards (조선소 시설물의 강풍 위험 평가)

  • Lee, Sung-Su;Kim, Hak-Sun;Lee, Young-Kyu;Shim, Kyu-Cheoul
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.9 no.4
    • /
    • pp.21-28
    • /
    • 2009
  • Most of domestic shipyards are located at coastal regions which are affected by typhoons nearly every year. For effectiveness of shipbuilding, shipyards contain many facilities which are light-weighted and affected dominantly by wind. In the present paper, we analyze various wind fields over a shipyard including surrounding topology and structures to evaluate the structural safety of the facilities posed in the strong wind. Extreme wind speed for a study region was estimated by typhoon Monte Carlo simulation and then used for inlet wind speed for CFD analysis for wind load on the facilities. Considering geometrical wind effects, we assess the surface pressure of the elements as the pressure factor, the ratio of surface pressure to dynamic pressure. The results show that the simulated wind speed is greater than the design wind speed for the some facilities because of the shipyard's geometry. It also shows that surrounding topography in coastal area is needed to be considered and adjustment for design wind speed at wind load standard application is necessary for mooring ship and industry facilities.