• Title/Summary/Keyword: Wind energy penetration

Search Result 69, Processing Time 0.03 seconds

Evaluation of renewable generation cost for designing the purchasing tariff system about renewable energy power (신.재생에너지전원의 발전차액지원제도 적용을 위한 발전원가 적용범위 산정)

  • Jo, I.S.;Rhee, C.H.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.840-842
    • /
    • 2005
  • Since 2001, Korea government has been purchasing the generation from renewable generation facilities with the higher incentive prices than market price in order to increase the penetration of renewable energies. Generally, the incentive purchase tariff is calculated on the base of the generation cost of renewable power facilities. This paper constructs the input data for economic analysis and evaluates the generation cost of PV, wind power, LFG and small hydro power using LCCA model.

  • PDF

Wind Power Smoothing Control Technique using Energy Storage System (에너지저장장치를 이용한 풍력발전의 출력 평준화 제어 기법 연구)

  • Lee, Jinho;Lee, Moonhwan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.178.1-178.1
    • /
    • 2010
  • 기후변화 대응을 위해 세계적으로 신 재생에너지의 분담율(penetration rate)은 갈수록 증가하고 있고, 정부에서는 2015년까지 신 재생에너지의 개발에 총 40조원을 투자한다는 적극적인 계획을 세우고 있다. 하지만 신 재생에너지 중 전력 생산에 가장 큰 비중을 차지하는 풍력발전은 비급전성과 간헐성 등의 제약으로 인해 안정적인 전력을 공급하기 힘들뿐만 아니라 전력계통의 신뢰성을 악화시킬 수도 있는 리스크를 잠재하고 있는 에너지원이다. 이에 풍력발전 등 신 재생에너지원의 출력을 안정화시키기 위한 Smart Renewable 프로젝트가 현재 제주도에서 실증 단계에 있다. 이 논문에서는 한국전력 컨소시엄의 Smart Renewable 프로젝트 대상인 660kW급 풍력터빈과 200kWh급 리튬-이온 배터리 에너지저장장치를 이용하여, 풍력터빈의 출력을 평활화시키는 평활화 제어(Smoothing Control)와 일정시간동안 균일한 출력을 낼 수 있게 하는 정출력 제어(Constant Power Control)의 두 가지 기법을 시뮬레이션 하였다. t 시점의 에너지저장장치 잔존용량을 피드백 받아 t+1 시점의 풍력터빈과 에너지저장장치 합성출력의 목표치를 설정하는 잔존용량 피드백 방법을 이용하여 에너지저장장치의 운전모드, 초기 용량, 평활화 시정수(time constant) 등의 조건 변화가 평활화 제어와 정출력 제어에 미치는 영향을 각각 확인하고, 주어진 기기 조건 하에서 최적의 시정수 값과 운전모드를 도출하였다.

  • PDF

The literature study on classification of cause and the effect of Acupuncture and Moxibustion treatment for Youk Jeol Poung (역절풍(歷節風)의 병인병기(病因病機)와 침구치료(鍼灸治療)에 관(關)한 문헌적(文獻的) 고찰(考察))

  • Yuh, Bok-Jong;Kim, Gi-Hyun
    • Journal of Haehwa Medicine
    • /
    • v.9 no.1
    • /
    • pp.443-459
    • /
    • 2000
  • The Literatural Study on the classification of cause and the effect of Acupuncture and Moxibustion treatment for Youk Jeol Poung was studied from the viewpoint of therapeutic acupuncture and moxibustion effect. And the results were as follows: 1. Youk Jeol Poung is similar to Tong Bi, Ju Bi, Haeng Bi, Tong Poung. 2. The symptoms of Youk Jeol Poung are pain and weakness, difficulty of flexion, swelling and pain, severe pain etc., at night pain is more severe. 3. The cause, mechanism of Youk Jeol Poung is as follow, due to penetration of the wind, cold, moisture, uder situation of whole body is pain. 4. The main treatment is invigorate vital energy and blood, expel wind - evil, promote diuresis, eliminating phlegm, promote blood circulation, cold, heat - clearing. 5. The basal meridian of acupuncture and moxibustion treatment were the channels of Su Jok Sam Yang.

  • PDF

A Bibliographical Study of Oriental Medical Records on Alopecia (탈발(脫髮)에 관한 한의학(韓醫學) 문헌적(文獻的) 고찰(考察))

  • Lee, Yeong-Jong
    • The Journal of Korean Medicine
    • /
    • v.16 no.1 s.29
    • /
    • pp.141-159
    • /
    • 1995
  • The causes and treatment of alopecia are concluded based on the records found successive oriental medicine in order to persuade new treatments for alopecia as following : 1. In the context of modern medical science male-dominated alopecia was referred as dok-rak(禿落), cho-dok(早禿), chon-dok(全禿), pal-ju-tal-bal, chu-bal-sun and pal-sun(髮癬) alternatively, while alopecia areata was refereed as yu-pung(油風), pan-dok(斑禿), kwi-ji-du and kwi-che-du(鬼剃頭). 2. The causes of alopecia is related with condition of Gi(vital energy) and Hyul(blood) in the twelve channels, such as weakening of vital energy in the conduits, condition of internal organs as heat in the lung, weak kidney or liver vitality, and eating habits such as severe ingestion of bitter taste or sweet taste food. Other distinct reasons are penetration of wind and dryness into a head due to weakening Gi and Hyul inside human body, flaring up of the asthenic fire due to excessive eatings, hard labour or psychological sufferings deficiency of blood, deficiency of vital essence of kidney, phlegm caused by dampness and heat, and stagnated blood. 3. According to demonstration of alopecia, the causes of alopecia areata are listed as internal wind due to heat of blood, deficiency of liver and kidney, blookage of channels and collaterals by stagnated blood, and causes of male-dominated alopecia are listed as wind dryness caused by heat of blood, dampness and heat, and heat, wind and dryness due to deficiency of blood.

  • PDF

Optimal Clustering of Energy Storage System for Frequency Regulation Service Considering Life Degradation (수명감소를 고려한 주파수 조정용 에너지저장장치의 최적 클러스터링)

  • Kim, Wook-Won;Kim, Jin-O
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.4
    • /
    • pp.555-560
    • /
    • 2016
  • Recently, many countries have placed great attention on energy security and climate changes. Governments are promoting the construction of renewable energy projects with regulatory support in Korea. Despite an increasing penetration of renewable resources, however, the photovoltaic and wind power are underutilized due to the endemic problems such as difficulties of output control and intermittent output. The Energy Storage System (ESS) is proposed as a good solution for solving the problems and has been studied in both the private business and the government. However, because of inefficient aspects, the research has been carried out for improving high costs and a small capacity. In addition, the ESS is currently installed for using only one purpose which is frequency regulation or transmission congestion relief such that has an economic limitation. Therefore, methods which are becoming economically justifiable to increase the penetration of the ESS is required. Thus, this paper presents in terms of operation efficiency to improve economic feasibility of the ESS currently used. mainly, there are two aspects for the operation efficiency. Firstly, it is intended to improve the utilization rate through a process that can utilize the ESS for various purposes. It is necessary to be able to use for other purposes by classifying and clustering for increasing the efficiency of availability. The clustering method is proposed to conduct the grouping the ESS. Especially, it is proposed to utilize ESS for frequency regulation service which is the one of ancillary services in the power system. Through case studies, it is confirmed to secure the necessary resources by clustering small size ESS.

Confinement Effect Analysis Of Suction Pile In Ground Soil On The Basis Of Natural Frequency Measurement (고유진동수 기반 석션기초의 지반구속효과 분석)

  • Ryu, Moo Sung;Lee, Jun Shin;Lee, Jong Hwa;Seo, Yun Ho
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.8 no.1
    • /
    • pp.31-36
    • /
    • 2022
  • This paper presents the measuring process of dynamic properties of offshore wind power foundation and provides consideration of each step. This Guideline enables to maintain consistent measuring procedure and therefore increase the reliability of test results. Small scaled suction bucket foundation was fabricated to represent the commercial support structure installation mechanism and two cases(free-free, free-fixed) of dynamic tests were performed at workshop. From the tests, the importance of dynamic properties of connection part between suction bucket and tower was figured out. More over, types and configuration of measuring devices are recommended which can help find the natural frequency of wind turbine foundation correctly. In field test, it was found that the natural frequency of suction bucket foundation was increased linearly with the penetration depth due to the confining effect of ambient soil. Meanwhile, it was not easy to get an enough excitation force with normal impact hammer because the N.F of suction bucket model was in the lower range of 0 Hz ~ 5 Hz. Therefore, new excitation method which has enough force and can excite lower frequency range was devised. This study will help develop safety check procedure of suction bucket foundation in field at each installation stage using the N.F measurement.

A PRELIMINARY STUDY OF EFFECT OF THE GREEN FEATURE - WING WALLS ON NATURAL VENTILATION IN BUILDINGS

  • Cheuk Ming Mak;Jian Lei Niu;Kai Fat Chan
    • International conference on construction engineering and project management
    • /
    • 2005.10a
    • /
    • pp.814-819
    • /
    • 2005
  • There is growing consciousness of the environmental performance of buildings in Hong Kong. The Buildings Department, the Lands Department and the Planning Department of the Hong Kong Government issued the first of a series of joint practice notes [1] to promote the construction of green and innovative buildings. Green features are architectural features used to mitigate migration of noise and various air-borne pollutants and to moderate the transport of heat, air and transmission of daylight from outside to indoor environment in an advantageous way. This joint practice note sets out the incentives to encourage the industry in Hong Kong to incorporate the use of green features in building development. The use of green features in building design not only improves the environmental quality, but also reduces the consumption of non-renewable energy used in active control of indoor environment. Larger window openings in the walls of a building may provide better natural ventilation. However, it also increases the penetration of direct solar radiation into indoor environment. The use of wing wall, one of the green features, is an alternative to create effective natural ventilation. This paper therefore presents a preliminary numerical study of its ventilation performance using Computational Fluid Dynamics (CFD). The numerical results will be compared with the results of the wind tunnel experiments of Givoni.

  • PDF

Performance Analysis of Hydrogen Based Hybrid System Using HOMER - a Case Study in South Korea (수소기반 신재생에너지 복합발전 시스템의 지역별 운영성과 분석 - HOMER를 활용한 사례 연구)

  • LEE, MYOUNG-WON;SON, MINHEE;KIM, KYUNG NAM
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.29 no.6
    • /
    • pp.606-619
    • /
    • 2018
  • This study focuses on the performance of hydrogen energy based hybrid system in terms of system reliability of electricity generation. With this aim to evaluate the off-grid system of photovoltaic (PV), wind turbine, electrolyzer, fuelcell, $H_2$ tank and storage batteries, 14 different sites in South Korea are simulated using HOMER. Performance analysis includes simulation on the different sites, verification of operational behaviors on regional and seasonal basis, and comparison among a control group. The result shows that the generation performance of hydrogen powered fuelcell is greatly affected by geographical change rather than seasonal effect. In addition, as the latitude of the hybrid systems location decrease, renewable power output and penetration ratio (%) increase under constant electrical load. Therefore, the hydrogen based hybrid system creates the stability of electricity generation, which best suits in the southern part of South Korea.

Rotor Speed-based Droop of a Wind Generator in a Wind Power Plant for the Virtual Inertial Control

  • Lee, Jinsik;Kim, Jinho;Kim, Yeon-Hee;Chun, Yeong-Han;Lee, Sang Ho;Seok, Jul-Ki;Kang, Yong Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.5
    • /
    • pp.1021-1028
    • /
    • 2013
  • The frequency of a power system should be kept within limits to produce high-quality electricity. For a power system with a high penetration of wind generators (WGs), difficulties might arise in maintaining the frequency, because modern variable speed WGs operate based on the maximum power point tracking control scheme. On the other hand, the wind speed that arrives at a downstream WG is decreased after having passed one WG due to the wake effect. The rotor speed of each WG may be different from others. This paper proposes an algorithm for assigning the droop of each WG in a wind power plant (WPP) based on the rotor speed for the virtual inertial control considering the wake effect. It assumes that each WG in the WPP has two auxiliary loops for the virtual inertial control, i.e. the frequency deviation loop and the rate of change of frequency (ROCOF) loop. To release more kinetic energy, the proposed algorithm assigns the droop of each WG, which is the gain of the frequency deviation loop, depending on the rotor speed of each WG, while the gains for the ROCOF loop of all WGs are set to be equal. The performance of the algorithm is investigated for a model system with five synchronous generators and a WPP, which consists of 15 doubly-fed induction generators, by varying the wind direction as well as the wind speed. The results clearly indicate that the algorithm successfully reduces the frequency nadir as a WG with high wind speed releases more kinetic energy for the virtual inertial control. The algorithm might help maximize the contribution of the WPP to the frequency support.

Design and Verification of Advanced Distribution Management System using Information and Communication Convergence Technology (ICT융복합 기술을 이용한 차세대 배전계통 운영 시스템 설계 및 검증)

  • Kim, Dongwook;Park, Youngbae;Chu, Cheolmin;Jo, Sungho;Seo, Inyong
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.15 no.4
    • /
    • pp.19-29
    • /
    • 2019
  • Recently, with the rise of environmental issues and the change of government policy (Renewable Energy 3020 Implementation Plan), a large amount of renewable energy such as solar and wind power is connected to the power system, and most of the renewable energy is concentrated in the power distribution network. This causes many problems with the voltage management and the protection coordination of the grid due to the its intermittent power generation. In order to effectively operate the distribution network, it is necessary to deploy more intelligent terminal devices in the field to measure the status of the distribution network and develop various operation functions such as visualization and big data analysis to support the power distribution system operators. In addition, the failover technology must be supported for the non-stop operation of the power distribution system. This paper proposes the system architecture of new power distribution management system to cope with high penetration of renewable energy. To verify the proposed system architecture, the functional unit test and performance measurement were performed.