• Title/Summary/Keyword: Wind energy

Search Result 3,011, Processing Time 0.033 seconds

Evaluation of Adhesion Property with Pot Life and Curing Humidity of GFRC and Epoxy Adhesive (유리섬유강화 복합재료와 에폭시 접착제의 가사시간과 경화습도에 따른 접착 강도 평가)

  • Yoo, Ji-Hoon;Shin, Pyeong-Su;Kim, Jong-Hyun;Lee, Sang-Il;Park, Joung-Man
    • Journal of Adhesion and Interface
    • /
    • v.21 no.2
    • /
    • pp.65-70
    • /
    • 2020
  • Epoxy adhesive was mainly used to combine different composite materials. Epoxy adhesive was a typical thermosetting resin that can be bonded by changing from a linear structure to a three-dimensional network structure by curing reaction of epoxy and hardener. The curing conditions of epoxy adhesive were different with different types of hardener such as mixing ratio, curing time, and temperature. These curing conditions affected to the adhesive property of epoxy adhesive. In industry, it was difficult to proceed the applying epoxy adhesive and combining two parts immediately. The adhesive property decreased by humidity and pre-curing of epoxy adhesive in waiting time between two processes. In this paper, the glass fiber reinforced composite (GFRC) was combined with epoxy adhesive and adhesion property between epoxy adhesive and GFRCs was evaluated using single lap shear test. The different waiting times and humidity conditions were applied to epoxy adhesive in room temperature and adhesive property decreased as the waiting time increased. In small amount of humidity, the adhesive property increased because a small amount of moisture in the surroundings accelerated the curing reaction. In certain amount of humidity, however, the adhesion property decreased.

Dynamic Peak Load Calculation for Friendly Environment Energy Supply and Demand Plan at the Newport Area in Busan (부산 신항만지역 환경친화적 에너지 수급을 위한 동적 열부하계산)

  • Yee, Jurng-Jae;Lee, Sun-Ae;Cho, Yong-Soo;Doe, Geun-Young
    • Journal of Navigation and Port Research
    • /
    • v.28 no.3
    • /
    • pp.269-276
    • /
    • 2004
  • The reclaimed land has peculiar characteristic of nature environment unlike midtown or inland and also, in comparison with inland, has bad weather condition, such as low temperature, strong wind, excessive sunshine, and moisture involved in a salt. Therefore the case of developing water front needs understanding characteristic of weather environment mused by reclamation in detail and proper development and organized maintenance. If development which doesn't investigate topographic and climate characteristic sufficiently is drove ahead, a rise of expense for energy and maintenance is going to be mused by deteriorating weather environmental, occurring a flaw of facility and calculating inaccurate capacity of facility. We looked into the weather state and drew up the standard weather data of the newport area in Busan which is reclaiming and developing now. In this research at the base qf the standard weather data, we calculate the dynamic peak loads for commerce, business and residence and then we utilize the results of the load calculation as basic information to determine facility capacity in the rear city of the newport area.

An Assessment of Areal Evaportranspiration Using Landsat TM Data (Landsat TM 자료를 이용한 광역 증발산량 추정)

  • Chae, Hyo-Seok;Song, Yeong-Su;Park, Jae-Yeong
    • Journal of Korea Water Resources Association
    • /
    • v.33 no.4
    • /
    • pp.471-482
    • /
    • 2000
  • Surface energy balance components were evaluated by Landsat TM data and GIS with meteorological data. Calibration and validation for the applicability of this methodology were made through the estimating of the large-scale evapotranspiration (ET). In addition, sensitivity and error analysis was conducted to see the effects of the surface energy balance components on ET and the accuracy of each components. Bochong-chon located on the upper part of Guem River basin was selected as the case study area. Spatial distribution map of ET were produced for five dates: Jan. 1, Apr. 3, May. 10, and Nov. 27, 1995. The study results showed tat ET was greatly varied with the aspect and theland use type on the surface. In the case of having northeast and southeast in the aspect, ET was linearly increased depending on growing net radiation. While surface temperature has a high value, NDVI(Normalized Difference Vegetation Index) has a low value in the vegetated area. Therefore, ground heat flux was increased but ET was relatively decreased. The results of sensitivity and error analysis showed that net radiation is most sensitive and effective, ranging from 12.5% to 23.6% of sensitivity. Furthermore, the surface temperature, air temperature, and wind speed have the significant effects on ET estimation using remotely sensed data.

  • PDF

Measurements of Storm Waves Generated by Typhoons Passed through Eastside of Korea Strait from 2004 to 2006 (2004~2006년 대한해협 동쪽을 통과한 태풍들에 의한 폭풍파 관측)

  • Jeong, Weon Mu;Kim, Sang Ik;Baek, Won Dae;Oh, Sang-Ho
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.26 no.2
    • /
    • pp.65-71
    • /
    • 2014
  • In recent years, strong typhoons have passed South Korea almost every year and severe damages were incurred directly and indirectly. However, instances where wave and wind data were procured from the offshore approach path of the typhoon are very rare and thus researchers are experiencing difficulties in obtaining calibration and verification data of typhoon-generated wave modeling. This paper provides a synthesis of records of observations by the Korea Meteorological Administration and Korea Institute of Ocean Science and Technology on storm waves generated by the typhoons SONGDA, NABI, and SHANSHAN that passed from 2004 to 2006 in order to help researchers interested in typhoon-generated wave numerical modeling. Although the trajectories of typhoon NABI and SHANSHAN were east of the Korea Strait, a significant wave height of 8.3 m was measured at Namhyeongjedo located east of Geojedo. Moreover, an unprecedented significant wave height of 12.2 m was measured for both typhoons at a station 1.4 km away from Yeongil Bay breakwater. Meanwhile, a comparative analysis of data obtained with a ocean data buoy at Geojedo and a Directional Waverider at Namhyeongjedo showed maximum wave heights that were similar but considerably different significant wave heights.

A Study on Electromagnetic Compatibility Performance Evaluation of Power Conditioning System for Residential Fuel Cell (가정용 연료전지 전력변환장치 전자파적합성 성능 평가 연구)

  • Choi, Young-Joo;Nam, Tae-Ho;Lee, Eun-Kyung;Lee, Duk-Gwon;Lee, Jung-Woon;Lee, Seung-Kuk;Moon, Jong-Sam
    • Journal of the Korean Institute of Gas
    • /
    • v.21 no.6
    • /
    • pp.23-29
    • /
    • 2017
  • Solar and wind energy among the renewable energy produce irregular power because resource is difficult to control. When connected to grid have unstable. However, when the fuel cell system is connected to grid more stable because regular frequency and output power based on controllable hydrogen energy. To using fuel cell system in the household, it is important that the safety performance of power conditioning system(PCS) and it is important that evaluation method of electromagnetic compatibility(EMC). In this study, we consider that introduce power-frequency magnetic field immunity test before analyzed that compare with the EMC of the international standards and KGS AB 934 PC53. Also, we conduct that actual assessment and study on available the quantitative analysis as using complementary indicator.

Evaluation of Wave Characteristics and JONSWAP Spectrum Model in the Northeastern Jeju Island on Fall and Winter (제주도 북동부 연안에서 추동계 파랑특성과 JONSWAP 스펙트럼의 적용성 평가)

  • Kang, Dong-Hyub;Lee, Byung-Gul
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.17 no.2
    • /
    • pp.63-69
    • /
    • 2014
  • Analysis frequency spectrum through observed wave data in northeastern shore, jeju island, during winter and fall, and review wave characteristics. In order to compute maximum wave height, we calculate the ratio of significant wave height to maximum wave height using the linear regression equation. In addition, for calculating JONSWAP spectrum, we assumed ${\gamma}$ value using significant wave height and peak frequency in the observation area. Consequently, the highest frequency is below 1 m in the case of significant wave height and during the first observation, the mean of height was estimated at 0.523 m and during the scend observation, it was 0.423 m. Furthermore, in peak frequency, the highest frequency was 0.12 Hz~0.15 Hz (period is nearly 6.67s~8.33s), the results of ${\gamma}$ from using significant wave height and peak frequency is 2.72 and the significant wave height calculated by straight linear regression equation was $1.635H_s$.

A Study on the Application of CIGS Solar Cells to Improve the Aesthetics of Public Facilities (공공시설물 심미성 향상을 위한 CIGS 태양전지 적용 방안 연구)

  • Lee, Saem;Seo, Ji-Young;Park, Su-Jy;Nam, Won-Suk;Jang, Jung-Sik
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.12
    • /
    • pp.235-243
    • /
    • 2021
  • As environmental problems accompanied by industrialization have emerged worldwide, solar and wind energy have entered the stage of commercialization, especially in Korea. In addition, research on improving aesthetics using solar cells is being actively conducted. Examples include developing a transmissive solar cell and developing a solar cell with flexibility and color. Therefore, in line with the upward trend of solar cell development and solar cell-based public facility installation, we will present guidelines for designing public facilities using solar cells to improve aesthetics. First of all, components were derived to increase the suitability of solar cell application through literature surveys on solar cells and case studies on public facilities using solar cells. Next, through prior research on public facility guidelines, we established evaluation principles and drafted design guidelines. Based on this, a Delphi survey was conducted on a group of experts to verify its validity. Design guidelines for solar cells application measures to improve the final public design aesthetics were derived. The goal is to improve the public facilities using solar cells, through Accessibility and cognition, Usability, Shape and aesthetics, Sustainability and energy efficiency, Continuity with the urban landscape. And it is expected that this data will be used to improve the aesthetics of public design using solar cells in the future.

A Study on the Development of Long-term Self Powered Underground Pipeline Remote Monitoring System (자가 발전형 장기 지하매설배관 원격감시 장치 개발에 관한 연구)

  • Kim, Youngsear;Chae, Hyun-Byung;Seo, Jae-Soon;Chae, Soo-Kwon
    • Journal of the Korean Society for Environmental Technology
    • /
    • v.19 no.6
    • /
    • pp.576-585
    • /
    • 2018
  • Systematic management during the whole life cycle from construction to operation and maintenance is very important for the seven underground pipelines (waterworks, sewerage, electricity, telecommunications, gas, heating, oil including waterworks and sewerage). Especially, it is the construction process that affects the whole life cycle of underground buried pipeline. In order to construct a new city or to maintain different underground pipes, it is always necessary to dig the ground and carry out construction and related work. There is a possibility that secondary and tertiary breaks frequently occur in the pipeline construction process after the piping constructed first in this process. To solve this problem, a system is needed which can monitor damage in real time. However, the supply of electric power for continuous operation of the system is limited according to the environment of underground buried pipelines, so it is necessary to develop a stable electric power supply system using natural energy rather than existing electric power. In this study, we developed a system that can operate the pipeline monitoring system for long time (24 hours and 15 days) using natural energy using wind and solar light.

On Building the Solar Dataset Form using the Kaggle Platform: The applicability of Machine Learning (캐글 플랫폼 활용한 태양광 데이터셋 형태 구축: 머신 러닝의 적용 가능성)

  • Ko, Ju-won;Park, Jung-jin;Park, Jin-woo;Oh, Do-hee;Kim, Mincheol
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.05a
    • /
    • pp.255-258
    • /
    • 2022
  • As environmental pollution continues, attention on renewable energy is on the constant rise in recent days. Although various kinds of renewable energy such as solar, wind power and biomass energy have been generated in Jeju, opening and analyzing cases on related data seem insufficient. Therefore, this study is being conducted to deduce the variables which have high relation with solar panel&s output and to understand machine learning methods that can be applied to solar power generation data by utilizing Kaggle platform, which is actively used by a number of scientists. Then, it is planned to propose a form of solar power generation dataset by researching machine learning methods that could be applied to the data. To be specific, analyzing solar power generation data with the Kaggle platform, this study will provide complements on gathering solar power data in Jeju. This study is anticipated to be utilized on data analysis for developing the solar power industry in Jeju. That is, this study is expected to reveal the room for improvement inherent in existing open datasets in Jeju, so that they could be constructed in a suitable form for machine learning for AI analytics. Through this process, a method to increase efficiency of solar power generation is anticipated to be prepared.

  • PDF

Analysis of the Effect of Heat Island on the Administrative District Unit in Seoul Using LANDSAT Image (LANDSAT영상을 이용한 서울시 행정구역 단위의 열섬효과 분석)

  • Lee, Kyung Il;Ryu, Jieun;Jeon, Seong Woo;Jung, Hui Cheul;Kang, Jin Young
    • Korean Journal of Remote Sensing
    • /
    • v.33 no.5_3
    • /
    • pp.821-834
    • /
    • 2017
  • The increase in the rate of industrialization due to urbanization has caused the Urban Heat Island phenomenon where the temperature of the city is higher than the surrounding area, and its intensity is increasing with climate change. Among the cities where heat island phenomenon occurs, Seoul city has different degree of urbanization, green area ratio, energy consumption, and population density in each administrative district, and as a result, the strength of heat island is also different. So It is necessary to analyze the difference of Urban Heat Island Intensity by administrative district and the cause. In this study, the UHI intensity of the administrative gu and the administrative dong were extracted from the Seoul metropolitan area and the differences among the administrative districts were examined. and linear regression analysis were conducted with The variables included in the three categories(weather condition, anthropogenic heat generation, and land use characteristics) to investigate the cause of the difference in heat UHI intensity in each administrative district. As a result of analysis, UHI Intensity was found to be different according to the characteristics of administrative gu, administrative dong, and surrounding environment. The difference in administrative dong was larger than gu unit, and the UHI Intensity of gu and the UHI Intensity distribution of dongs belonging to the gu were also different. Linear regression analysis showed that there was a difference in heat island development intensity according to the average wind speed, development degree, Soil Adjusted Vegetation Index (SAVI), Normalized Difference Built-up Index (NDBI) value. Among them, the SAVI and NDBI showed a difference in value up to the dong unit and The creation of a wind route environment for the mitigation of the heat island phenomenon is necessary for the administrative dong unit level. Therefore, it is considered that projects for mitigating heat island phenomenon such as land cover improvement plan, wind route improvement plan, and green wall surface plan for development area need to consider administrative dongs belonging to the gu rather than just considering the difference of administrative gu units. The results of this study are expected to provide the directions for urban thermal environment design and policy development in the future by deriving the necessity of analysis unit and the factors to be considered for the administrative city unit to mitigate the urban heat island phenomenon.