• Title/Summary/Keyword: Wind distributions

Search Result 346, Processing Time 0.024 seconds

Numerical analysis of wind field induced by moving train on HSR bridge subjected to crosswind

  • Wang, Yujing;Xia, He;Guo, Weiwei;Zhang, Nan;Wang, Shaoqin
    • Wind and Structures
    • /
    • v.27 no.1
    • /
    • pp.29-40
    • /
    • 2018
  • To investigate the characteristics of the combined wind field produced by the natural wind field and the train-induced wind field on the bridge, the aerodynamic models of train and bridge are established and the overset mesh technology is applied to simulate the movement of high-speed train. Based on ten study cases with various crosswind velocities of 0~20 m/s and train speeds of 200~350 km/h, the distributions of combined wind velocities at monitoring points around the train and the pressure on the car-body surface are analyzed. Meanwhile, the difference between the train-induced wind fields calculated by static train model and moving train model is compared. The results show that under non-crosswind condition, the train-induced wind velocity increases with the train speed while decreases with the distance to the train. Under the crosswind, the combined wind velocity is mainly controlled by the crosswind, and slightly increases with the train speed. In the combined wind field, the peak pressure zone on the headstock surface moves from the nose area to the windward side with the increase of wind velocity. The moving train model ismore applicable in analyzing the train induced wind field.

Wind loads on fixed-roof cylindrical tanks with very low aspect ratio

  • Lin, Yin;Zhao, Yang
    • Wind and Structures
    • /
    • v.18 no.6
    • /
    • pp.651-668
    • /
    • 2014
  • Wind tunnel tests are conducted to investigate the wind loads on vertical fixed-roof cylindrical tanks with a very low aspect ratio of 0.275, which is a typical ratio for practical tanks with a volume of $100,000m^3$. Both the flat-roof tank and the dome-roof tank are investigated in present study. The first four moments of the measured wind pressure, including the mean and normalized deviation pressure, kurtosis and skewness of the pressure signal, are obtained to study the feature of the wind loads. It is shown that the wind loads are closely related to the behavior of flow around the structure. For either tank, the mean wind pressures on the cylinder are positive on the windward area and negative on the sides and the wake area, and the mean wind pressures on the whole roof are negative. The roof configurations have no considerable influence on the mean pressure distributions of cylindrical wall in general. Highly non-Gaussian feature is found in either tank. Conditional sampling technique, envelope method, and the proper orthogonal decomposition (POD) analysis are employed to investigate the characteristics of wind loads on the cylinder in more detail. It is shown that the patterns of wind pressure obtained from conditional sampling are similar to the mean pressure patterns.An instantaneous pressure coefficient can present a wide range from the maximum value to the minimum value. The quasi-steady assumption is not valid for structures considered in this paper according to the POD analysis.

An Analysis of Wind Force Coefficient Distributions for Optimum Design of Multi-Span Arched Greenhouses (아치형 연동온실의 최적설계를 위한 풍력계수분포도의 분석)

  • 이현우;이석진
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.38 no.2
    • /
    • pp.145-151
    • /
    • 1996
  • Wind force coefficients of multi-span arched greenhouses with respect to wind direction of $0^{\circ}$ and $30^{\circ}$ were estimated to give more reasonable coefficient. The conventional and subdivided division types of wind force coefficient distribution diagrams were constructed by using the wind tunnel experimental data. Bending moments on the greenhouses were determined through structural analysis using obtained wind force coefficients, and were analyzed. Because actual wind pressure values on a face of greenhouse varied with locations, the more divisions of wind force coefficient distribution were subdivided, the better distribution type was coincided with actual state. In order to calculate the more accurate section force occurred on the arched greenhouse by the wind loads, it was recommendable that the wind force coefficient distribution should take more subdivision type. The maximum bending moment at the multi-span greenhouse frame at wind direction of $30^{\circ}$ was greater than that at O。, therefore the wind force coefficient at inclined wind direction to the wall was needed to be considered for the multi-span greenhouse structural design.

  • PDF

Validation study of the NCAR reanalysis data for a offshore wind energy prediction (해상풍력자원 예측을 위한 NCAR데이터 적용 타당성 연구)

  • Kim, Byeong-Min;Woo, Jae-Kyoon;Kim, Hyeon-Gi;Paek, In-Su;Yoo, Neung-Soo
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.1
    • /
    • pp.1-7
    • /
    • 2012
  • Predictions of wind speed for six different near-shore sites were made using the NCAR (National Center for Atmospheric Research) wind data. The distances between the NCAR sites and prediction sites were varied between 40km and 150km. A well-known wind energy prediction program, WindPRO, was used. The prediction results were compared with the measured data from the AWS(Automated Weather Stations). Although the NCAR wind data were located far away from the AWS sites, the prediction errors were within 9% for all the cases. In terms of sector-wise wind energy distributions, the predictions were fairly close to the measurements, and the error in predicting main wind direction was less than $30^{\circ}$. This proves that the NCAR wind data are very useful in roughly estimating wind energy in offshore or near-shore sites where offshore wind farm might be constructed in Korea.

Estimation of Surface Wind Speed on the Strong Wind Damage by Typhoon (태풍으로 인한 강풍 피해 추정을 위한 지상풍 산정 연구(Ⅰ))

  • Park, Jong-Kil;Jung, Woo-Sik;Choi, Hyo-Jin
    • 한국방재학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.85-88
    • /
    • 2008
  • Damage from typhoon disaster can be mitigated by grasping and dealing with the damage promptly for the regions in typhoon track. What is this work, a technique to analyzed dangerousness of typhoon should be presupposed. This study estimated 10m level wind speed using 700hPa wind by typhoon, referring to GPS dropwindsonde study of Franklin(2003). For 700hPa wind, 30km resolution data of Regional Data Assimilation Prediction System(RDAPS) were used. For roughness length in estimating wind of 10m level, landuse data of USGS are employed. For 10m level wind speed of Typhoon Rusa in 2002, we sampled AWS point of $7.4\sim30km$ distant from typhoon center and compare them with observational data. The results show that the 10m level wind speed is the estimation of maximum wind speed which can appear in surface by typhoon and it cannot be compared with general hourly observational data. Wind load on domestic buildings relies on probability distributions of extreme wind speed. Hence, calculated 10m level wind speed is useful for estimating the damage structure from typhoon.

  • PDF

An Estimation of Extreme Wind Speed of Typhoon Affecting the Damage of Public and Industrial Facilities (공공 및 산업시설 피해에 영향을 미치는 태풍의 최대풍속 도출)

  • Jung, Woo-Sik
    • Journal of Environmental Science International
    • /
    • v.24 no.9
    • /
    • pp.1199-1210
    • /
    • 2015
  • There were 35 typhoons affecting Korean Peninsula from 1999 to 2009(The average annual number of typhoon is 3.18). Among these typhoons, the number of typhoon passing through the Yellow sea, the Southern sea and the East sea were 14, 6 and 15 respectively. Wind speed on the height of 10 m can be finally estimated using the surface roughness after we calculate wind speed on the height of 300 m from the data on the surface of 700 hPa. From the wind speeds on the height of 10 m, we can understand the regional distributions of strong wind speed are very different according to the typhoon tracks. Wind speed range showing the highest frequency is 10~20 m/s(45.69%), below 10 m/s(30.72%) and 20~30 m/s(17.31%) in high order. From the analysis of the wind speed on the hight of 80 m, we can know the number of occurrence of wind speed between 50 and 60 m/s that can affect wind power generation are 104(0.57%) and those of between 60 and 70 m/s that can be considered as extreme wind speed are even 8(0.04%).

Characteristics of Wind Pressure Distributions Acting on Solar Collector Plate (태양열 집열판에 작용하는 풍압계수 분포 특성)

  • You, Ki-Pyo;Kim, Young-Moon;You, Jang-Youl
    • Journal of Korean Association for Spatial Structures
    • /
    • v.13 no.2
    • /
    • pp.67-73
    • /
    • 2013
  • This paper attempted to bridge this gap by identifying the number of flat-plate solar collectors. The characteristics of wind pressure coefficients acting on flat-plate solar collectors which are most widely used were investigated for various wind direction. Findings from this study found that the location where the maximum wind pressure coefficient occurred in the solar collector was the edge of the collector. Regarding the characteristics according to the number of collectors, the paper found that downward wind pressure coefficient of the lower edge of the collector was higher than the upward wind pressure coefficient of the upper edge of the collector in the basic module (1 piece). However, as the number of collectors increases, the upward wind pressure coefficient of the upper edge become higher than the downward wind pressure coefficient of the lower edge. Finally yet important, it was found that the location of the maximum wind pressure coefficient was changed according to the number of solar collectors.

Wind loads and wind-resistant behaviour of large cylindrical tanks in square-arrangement group. Part 2: CFD simulation and finite element analysis

  • Liu, Qing;Zhao, Yang;Cai, Shuqi;Dong, Shilin
    • Wind and Structures
    • /
    • v.31 no.6
    • /
    • pp.495-508
    • /
    • 2020
  • To investigate the structural behaviour of grouped tanks under wind loads, 2 problems need to be figured out, wind pressures on tank shells and critical loads of the shell under these pressure distribution patterns. Following the wind tunnel tests described in the companion paper, this paper firstly seeks to obtain wind loads on the external wall in a squarely-arranged cylindrical tank group by numerical simulation, considering various layouts. The outcomes demonstrate that the numerical method can provide similar results on wind pressures and better insights on grouping effects through extracted streamlines. Then, geometrically nonlinear analyses are performed using several selected potentially unfavourable wind pressure distributions. It is found that the critical load is controlled by limit point buckling when the tank is empty while excessive deformations when the tank is full. In particular, significant reductions of wind resistance are found on grouped full tanks compared to the isolated tank, considering both serviceability and ultimate limit state, which should receive special attention if the tank is expected to resist severe wind loads with the increase of liquid level.

Experimental and Computational Investigation of Wind Flow Field on a Span Roof Structure

  • K B Rajasekarababu;G Vinayagamurthy;Ajay Kumar T M;Selvirajan S
    • International Journal of High-Rise Buildings
    • /
    • v.11 no.4
    • /
    • pp.287-300
    • /
    • 2022
  • Unconventional structures are getting more popular in recent days. Large-span roofs are used for many structures, such as airports, stadiums, and conventional halls. Identifying the pressure distribution and wind load acting on those structures is essential. This paper offers a collaborative study of computational fluid dynamics (CFD) simulations and wind tunnel tests for assessing wind pressure distribution for a building with a combined slender curved roof. The hybrid turbulence model, Improved Delayed Detached Eddy Simulation (IDDES), simulates the open terrain turbulent flow field. The wind-induced local pressure coefficients on complex roof structures and the turbulent flow field around the structure were thus calculated based upon open terrain wind flow simulated with the FLUENT software. Local pressure measurements were investigated in a boundary layer wind tunnel simultaneous to the simulation to determine the pressure coefficient distributions. The results predicted by CFD were found to be consistent with the wind tunnel test results. The comparative study validated that the recommended IDDES model and the vortex method associated with CFD simulation are suitable tools for structural engineers to evaluate wind effects on long-span complex roofs and plan irregular buildings during the design stage.

A correlation-based analysis on wind-induced interference effects between two tall buildings

  • Xie, Z.N.;Gu, M.
    • Wind and Structures
    • /
    • v.8 no.3
    • /
    • pp.163-178
    • /
    • 2005
  • Wind-induced mean and dynamic interference effects of tall buildings are studied in detail by a series of wind tunnel tests in this paper. Interference excitations of several types of upwind structures of different sizes in different upwind terrains are considered. Comprehensive interference characteristics are investigated by artificial neural networks and correlation analysis. Mechanism of the wakes vortex-induced resonance is discussed, too. Measured results show significant correlations exist in the distributions of the interference factors of different configurations and upwind terrains and, therefore, a series of relevant regression equations are proposed to simplify the complexity of the multi-parameter wind induced interference effects between two tall buildings.