• 제목/요약/키워드: Wind Pressure Test

Search Result 316, Processing Time 0.023 seconds

A study on design and performance test of fire door with high endurance performance in submarine tunnel (고내구성능을 갖는 해저터널 방화문 설계방안 및 성능시험 연구)

  • Park, Sang-Heon;Hwang, Ju-Hwan;Choi, Young-Hwan;An, Sung-Joo;Yoo, Yong-Ho
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.2
    • /
    • pp.331-346
    • /
    • 2018
  • In the tunnel of domestic high - speed railway, the main fire - fighting facility, fire - extinguishing passageway, is installed. However, due to the high pressure of the high - speed train, frequent breakage and maintenance are caused by strong shock and long - term vibration. In order to solve these problems, it is necessary to improve the fire door, but in Korea, it is installed by submitting a certificate by simple KS F 2296 performance test. At present, it is developed as a simple test certification by producing a real scale fireproof door without the theoretical examination in advance, so that a high cost for improvement is occurring in Korea. Therefore, through this study, structural analysis study which can preliminary structure review was carried out in order to design the refuge connection passage fire door and to improve the performance improvement. In order to secure the reliability of the result value, the official authentication test (KS F 2296) were compared.

Removal Efficiency of PM10 & $CO_2$ in Subway Mock-up Cabin (지하철 목업차량내 객실 공기정화장치의 미세먼지(PM10) 및 $CO_2$ 저감성능평가)

  • Kwon, Soon-Bark;Park, Duck-Shin;Cho, Young-Min;Kim, Jong-Bum;Cho, Goan-Hyun;Nam, Goong-Seok;Lee, Joo-Yeol;Kim, Tae-Sung
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.613-618
    • /
    • 2011
  • More than 7 million persons use Seoul Metropolitan Subways (SMS) everyday and the number has been in increasing trend. With the increasing trend of concerns on indoor air quality(IAQ), the management of IAQ has become an important issue, especially in case of subway operators, because most of subway lines are placed underground with poor ventilation condition. The ultimate object of study develop independent cleaning device that reduce efficient fine particle and $CO_2$. Urban subway has characteristics about proper clean air flow, must be installed in narrow space and maintenance cycle has enough time. Two layered electrically pre-charged filters were used for removing particulate matters and gas absorbers are packed between two layer filters for removing gases pollutants such $CO_2$, VOCs and HCHO. Urban subway has characteristics about proper clean air flow, must be installed in narrow space and maintenance cycle has enough time. SCAP prototype is producted as all in one method which decrease fine dust, $CO_2$ and noxious gas. and basic test carry out with quantity of wind, a gap of pressure, sampling efficiency.

  • PDF

THE AERO-ACOUSTIC ANALYSIS FOR EACH PART OF DOUBLE ARM PANTOGRAPH OF HIGH SPEED TRAIN (전산해석을 통한 고속철도 더블암 팬터그래프의 부재별 공력소음특성 연구)

  • Lee, S.A.;Kang, H.M.;Lee, Y.B.;Kim, C.W.;Kim, K.H.
    • Journal of computational fluids engineering
    • /
    • v.20 no.2
    • /
    • pp.61-66
    • /
    • 2015
  • In this study, an aero-acoustic analysis around pantograph of a high speed train is performed. Computational technique and grid system is validated with wind tunnel test result and unsteady acoustic pressure data are used for analyzing noise level of each part of pantograph. FLUENT is used for flow analysis and LES(Large Eddy Simulation) is applied for analyzing turbulent flow. For acoustic analysis, Ffowcs Williams-Hawkings(FW-H) acoustics model is used and it bring the aero-acoustic characteristic of pantograph. As the result, contact strip, knee, substructure of pantograph is confirmed as a main source of aero-acoustic noise and it is dealt in various frequencies. The result is expected to help building improved grid system.

Numerical Investigation of Jet Interaction for Missile with Continuous Type Side Jet Thruster

  • Kang, Kyoung Tai;Lee, Eunseok;Lee, Soogab
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.16 no.2
    • /
    • pp.148-156
    • /
    • 2015
  • A continuous type side jet controller which has four nozzles with thrust control devices was considered. It is deployed to a missile for high maneuverability and fast controllability in the terminal guidance phase. However, it causes more complex aerodynamic jet interactions between the side jet and the supersonic free stream than does the conventional impulse type side jet with a small single thruster. In this paper, a numerical investigation of the jet interference effects for the missile equipped with a continuous type side jet thruster is presented. A three-dimensional flow field was simulated by using a commercial unstructured-based CFD solver. The numerical simulation method was validated through comparison with wind tunnel test results for the single jet. The method of defining jet direction for this type of side jet control to minimize simulation cases was also introduced. Flow fields investigation and jet interaction effects for various flow conditions, jet pressure ratios and defined jet direction conditions were performed. From the numerical simulation for the continuous type side jet, extensive aerodynamic interference data were obtained to construct an aerodynamic coefficients database for precise missile control.

Seismic Noise Reduction Using Micro-Site Array Stacking (미소-위치 배열 중합을 이용한 지진파의 잡음제거)

  • Choi, Hun;Sohn, Sang-Wook;Bae, Hyeon-Deok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.3
    • /
    • pp.395-403
    • /
    • 2014
  • This paper presents a new approach to improve the signal to noise ratio (SNR) for local seismic disaster preventing system in densely populated area. The seismic data measured in the local site includes various sensing noises (offset or measurement noise) and man-made/natural noises (road and rail traffic noise, rotating or hammering machinery noise, human activity noise such as walking and running, wind/atmospheric pressure-generated noise, etc.). These additive noises are different in time and frequency characters. The proposed method uses 3-stages processing to reduce these different additive noises. In the first stage, misalignment offset noise are diminished by time average processing, and then the second and third stages, coherent/incoherent noises such as man-made/natural noises are suppressed by array stacking. In addition, we derived the theoretical equation of the SNR gain improved by the proposed method. To evaluate the performance of the proposed method, computer simulations were performed with real seismic data and test equipment generated data as the input.

Development of Hold on Swing a Jumper Support String for Overhead Transmission Line (송전선로 점퍼선 횡진방지용 지지애자장치 개발)

  • Baik, Seung-Do;Min, Byeong-Wook;Wi, Hwa-Bog;Park, Kee-Yong;Keum, Eui-Yeon;Jeong, Heon-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.521-523
    • /
    • 2005
  • A Jumper wire is currently used to connect each fixed power line on both sides of dead end tower for overhead transmission line, but in case of a jumper wire swing under circumstances of typhoon, etc. and the air clearance is deficient then a flashover fault may Happen. Now the angle tower has the jumper support string to prevent a swing of jumper wire and to secure the air clearance between jumper wire and tower main body, but the flashover fault by swing of jumper wire was happened yl times across all over the country, because of the typhoon 'Rusa' in year 2002 and 'Maemi' in year 2003. This paper presents the design and development of 'Counter Weight' which enables to keep the swing angle of jumper wire under 40 degree in design condition to prevent a flashover fault by swing of jumper wire by a high wind pressure load in case of typhoon and have completed a mechanical and electrical characteristic test.

  • PDF

Experiments on the Effective Engine Room Ventilation in a Power Car (동력 철도차량 기관실의 효과적인 환기에 관한 실험적 연구)

  • Han, S.Y.;Lee, J.H.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.2 no.3
    • /
    • pp.166-176
    • /
    • 1990
  • Experimental study was made to find the effective ways for cooling of engine room in a power car through natural ventilation, forced ventilation and wind tunnel test of 1:10 model. Through the measurements of inner temperature of engine room and pressure distribution of model surface for the various opening combinations and the fan locations, the following results are obtained. For natural ventilation, side and top opening combination is more effective than the side openings only and optimal opening combination is all side openings with top center opening. For forced ventilation with fan on the roof, the combination of all sides and top opening is more effective than the combination of side and top opening, and the optimal location of fan is top center. When the model is located in the air stream, the combination of side and top opening is more effective than the side openings only, and the optimal location of top opening is the front opening. With both air stream and forced ventilation, the optimal location of fan is the side region, and the direction of side grill installation is found to have negligible effect on the room ventilation.

  • PDF

EXPERIMENTAL REPRODUCTION AND NUMERICAL ANALYSIS OF THE SIDE FORCE ON AN OGIVE FOREBODY AT A HIGH ANGLE OF ATTACK (고받음각 동체에 발생하는 측력의 실험적 재현 및 수치적 분석)

  • Lee, E.S.;Lee, J.I.;Lee, K.S.
    • Journal of computational fluids engineering
    • /
    • v.18 no.1
    • /
    • pp.28-35
    • /
    • 2013
  • Behavior of the side force generated at high angles of attack by two ogive-cylinder bodies of revolution with nose fineness ratio of 2.3 (B1) and 3.5 (B2) and the effect of a strip placed close the nose tip of each body (B1S and B2S) are analyzed through the wind tunnel test at ReD=200,000 and a=42~60 deg. The side force generated by B1 is increased by placing a strip. The side force generated by B2 is in the starboard direction and its magnitude is higher than that of the B1S. The effect of the strips with various dimensions placed on B2 is investigated. It is found that the 4-layer strip placed on the starboard reversed the direction of the side force into port direction. It is confirmed by numerical simulations that the strip promotes the flow separation and increases the average pressure on the side where it is placed and consequently produces the side force in the corresponding direction.

Heat/Mass Transfer Measurements on a Film Cooled Blade with Naphthalene Saturated Coolant (나프탈렌 포화공기가 분사되는 막냉각 홀을 가진 터빈 블레이드 표면의 열/물질전달 계수 측정)

  • Lee, Dong-Hyun;Rhee, Dong-Ho;Kim, Kyung-Min;Cho, Hyung-Hee;Kim, Beom-Su
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.05a
    • /
    • pp.433-436
    • /
    • 2010
  • In this paper, heat/mass transfer characteristics on a film cooled stationary rotor blade are investigated using the naphthalene sublimation method. A row-speed annular wind tunnel with a single annular turbine stage is used. Three rows of film cooling holes are machined on the leading edge of the test blade. Detailed heat/mass transfer distributions are measured with changing the blowing rate from 1.0 to 2.0. As the blowing ratio increases, overall heat/mass transfer increases and the lower peak formed on the pressure side were disappeared.

  • PDF

The effects of meteorological factors on the sales volume of apparel products - Focused on the Fall/Winter season - (기상요인이 의류제품 판매량에 미치는 영향 - F/W 판매데이터(9월~익년 2월)를 근거로 -)

  • Kim, Eun Hie;Hwangbo, Hyunwoo;Chae, Jin Mie
    • The Research Journal of the Costume Culture
    • /
    • v.25 no.2
    • /
    • pp.117-129
    • /
    • 2017
  • The purpose of this study was to investigate meteorological factors' effects on clothing sales based on empirical data from a leading apparel company. The daily sales data were aggregated from "A" company's store records for the Fall/Winter season from 2012 to 2015. Daily weather data corresponding to sales volume data were collected from the Korea Meteorological Administration. The weekend effect and meteorological factors including temperature, wind, humidity, rainfall, fine dust, sea level pressure, and sunshine hours were selected as independent variables to calculate their effects on A company's apparel sales volume. The analysis used a SAS program including correlation analysis, t-test, and multiple-regression analysis. The study results were: First, the weekend effect was the most influential factor affecting sales volume, followed by fine dust and temperature. Second, there were significant differences in the independent variables'effects on sales volume according to the garments' classification. Third, temperature significantly affected outer garments'sales volume, while top garments' sales volume was not influenced significantly. Fourth, humidity, sea level pressure and sunshine affected sales volume partly according to the garments' item. This study can provide proof of significant relationships between meteorological factors and the sales volume of garments, which will serve well to establish better inventory strategies.