• Title/Summary/Keyword: Wilcoxon detector

Search Result 8, Processing Time 0.024 seconds

Development of Statistical Edge Detector in Noisy Images and Implementation on the Web

  • Lim, Dong-Hoon
    • 한국데이터정보과학회:학술대회논문집
    • /
    • 2004.04a
    • /
    • pp.197-201
    • /
    • 2004
  • We describe a new edge detector based on the robust rank-order (RRO) test which is a useful alternative to Wilcoxon test, using $r{\times}r$ window for detecting edges of all possible orientations in noisy images. Some experiments of statistical edge detectors based on the Wilcoxon test and T test with our RRO detector are carried out on synthetic and real images corrupted by both Gaussian and impulse noise. We also implement these edge detectors using Java on the Web.

  • PDF

Development and Implementation of Statistical Edge Detectors on the Web (웹 상에서 통계적 에지검출기 개발 및 구현)

  • Lim, Dong-Hoon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.10 no.4 s.36
    • /
    • pp.133-141
    • /
    • 2005
  • An edge is where the intensity of an image moves from a low value to high value or vice versa. The edges tell where objects are. their shape and size. and something about their texture. Many traditional edge operators are derivative based and perform reasonably well for simple noise-free images. In recent, statistical edge detectors for complex images with noises have been described. This paper compares and analysis the performance of statistical edge detectors based on the T test and Wilcoxon test, and mathematical edge detectors based on Sobel operator, and the well-known Canny detector and Wavelet transformation detector, and provides the implementation of these edge detectors using Java on the web.

  • PDF

Efficient Edge Detection in Noisy Images using Robust Rank-Order Test (잡음영상에서 로버스트 순위-순서 검정을 이용한 효과적인 에지검출)

  • Lim, Dong-Hoon
    • The Korean Journal of Applied Statistics
    • /
    • v.20 no.1
    • /
    • pp.147-157
    • /
    • 2007
  • Edge detection has been widely used in computer vision and image processing. We describe a new edge detector based on the robust rank-order test which is a useful alternative to Wilcoxon test. Our method is based on detecting pixel intensity changes between two neighborhoods with a $r{\times}r$ window using an edge-height model to perform effectively on noisy images. Some experiments of our robust rank-order detector with several existing edge detectors are carried out on both synthetic images and real images with and without noise.

Development of a Fruit Sorting System using Statistical Image Processing (통계적 영상처리를 이용한 과일 선별시스템 개발)

  • 임동훈
    • The Korean Journal of Applied Statistics
    • /
    • v.16 no.1
    • /
    • pp.129-140
    • /
    • 2003
  • This study was to develop a fruit sorting system using statistical image processing. Histogram was used to compare fruit colors to standard fruit color and edge detector using Wilcoxon test was used to calculate an accurate geometrical characteristics of fruit including perimeter, area, major axis and minor axis length and roundness. The experimental result obtained from using our system for sorting apples was presented.

Performance Comparisons of some nonparametric detectors (몇가지 비모수 검파기의 성능 비교)

  • 김홍길;송익호;장태주;배진수
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 1996.06a
    • /
    • pp.9-15
    • /
    • 1996
  • In this paper, we propose a new detector based on the median-shift sign. We call it the median-shift sign (MSS) detector, which is an extension of the classical sign detector. We first analyze the problem of detecting a dc signal in noise of known probability density function (pdf). The MSS detector with the optimum median-shift value, the optimum MSS detector, performs better than the sign detector in Gaussian noise: it has the best performance among the detectors compared in Laplacian and Cauchy noise. It is shown that the MSS detectors with constant median-shift values are nearly equal to the optimum MSS detector. We also analyze the problem of detecting a dc signal when only partial information is available on the noise. The MSS detectors with constant median-shift values are almost equal to the sign detector in Gaussian noise: they perform better than the sign and Wilcoxon detectors for most signal ranges in Laplacian and Cauchy noise.

  • PDF

Two-sample Tests for Edge Detection in Noisy Images (잡음영상에서 에지검출을 위한 이표본 검정법)

  • 임동훈;박은희
    • The Korean Journal of Applied Statistics
    • /
    • v.14 no.1
    • /
    • pp.149-160
    • /
    • 2001
  • In this paper we employ two-sample location tests such as Wilcoxon test and T test for detecting edges in noisy images. For this, we compute a test statistic on pixel gray levels obtained using an edge-height parameter and compare it with a threshold determined by a significance level. Experimental results applied to sample images are given and performances of these tests in terms of the objective measure are compared.

  • PDF

Study on the Absorption and Excretion of Capsaicin in Rabbits (가토에 있어서 Capsaicin의 흡수 및 배설에 관한 연구)

  • 김낙두;박찬용
    • YAKHAK HOEJI
    • /
    • v.25 no.3
    • /
    • pp.101-108
    • /
    • 1981
  • Quantitative determination of capsaicin in biological fluid was investigated. The pharmacokinetic study of capsaicin in rabbits was performed by high-pressure liquid chromatography, equipped with a microparticulate reversed-phase column and a fixed wavelength detector. Elution was carried out using methanolwater(70:30). It allows the quantitative determination at 8-400 ng level. When single dose of capsaicin(4mg/kg) was given to rabbits intravenously, the elimination phase was extremely short with average half-life to 17.35 minute. Urine excretion of capsaicin itself during first 2 hours after intravenous administration (4mg/kg) was 0.004-0.04% of the administered amount. The maximum plasma concentration of capsaicin after oral administration (300mg/kg) was $4{\times}10^{-7}$g/ml at 40 minutes. The $LD_{50}$ of capsaicin in mouse was 0.40mg/kg (i.v.) and 47.2 mg/kg (p.o.) which was determined by Litchfield and Wilcoxon's method, suggesting that the gastrointestinal absorption of capsaicin is poor.

  • PDF

Radiation Dose using Chest CT for Patients with Pneumoconiosis Complication - Comparison with International Guidelines - (진폐요양환자의 흉부 CT촬영에 사용된 선량 - 국내외 진단 참고 준위와 비교 -)

  • Lee, Won-Jeong
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.4
    • /
    • pp.206-212
    • /
    • 2014
  • We report here on the results of evaluating the radiation doses using chest computed tomography (CT) for patients with pneumoconiosis complication. For the first time, we visited the 17 MIPs to evaluate the dose-length product (DLP, $mGy{\cdot}cm$), CT unit, and protocols of scanning and image reconstruction those is routinely used for treating patients with pneumoconiosis who have complication. All statistical analysis was performed using the Statistical Program for Social Sciences (SPSS ver. 19.0, Chicago, IL, USA). Mean of total DLP was $727.7mGy{\cdot}cm$, ranging from 272.0 to $1228.7mGy{\cdot}cm$. DLP from obtaining parenchymal lung images was significantly reduced than that from obtaining total lung images (555.9 vs. 707.2, p<0.001). Third quartile of total and pre-scanning DLP was 1036.1 and $504.1mGy{\cdot}cm$, respectively. Chest CT radiation doses for patients with pneumoconiosis complication are similar with korean diagnostic reference level as well as international guidelines.